• 제목/요약/키워드: Ballast Water Management

검색결과 66건 처리시간 0.025초

선박 평형수 처리장치 선정을 위한 경제성 분석 (Economy Analysis to Retrofit Ballast Water Treatment System for an Existing Vessel)

  • 지재훈;박상균;오철
    • 수산해양교육연구
    • /
    • 제28권5호
    • /
    • pp.1319-1328
    • /
    • 2016
  • Since Ballast Water Management Convention has been effected, BWTS, applied to new-building vessels and existing vessels, have been developed from many countries with various treatment methods. However, BWTS is mainly typed Electrolysis, Ozone and UV type. Approximately 70 products have been type approved by the Flag Administrations. For the new-building vessels, the vessels' design and construction have been considered for arrangements and installations for BWTS. However, existing vessels which already construction had finished have problem with selection of BWTS type for installation and arrangement. The selection of the most economized BWTS system is important though, CAPEX has not been made any significant differences. However, OPEX is more important factor. Consequently, detail analysis of OPEX is the key to the selection of the most economized BWTS system and also it can be the purpose of this study. The feasibility study on the main three type of BWTS (Electrolysis, Ozone and UV type) for 175K Bulk Carrier and 57K Cargo ship has been conducted for this study. Because, these three type of BWTS have been the most frequently installed and used and the two type of object vessels are consist of the 40% of the world merchant ship market. For this study, interest rate, project duration (operation time after installation), maintenance cost and fuel oil price are considered as major factor of feasibility study. In addition, expecting Interest rates to sensitivity analysis conducted for more accurate feasibility study. For 175K Bulk carrier, ozone treatment system is more economical than other types. For 57K cargo ship, UV type is considered more economical than other types. However, it is concluded that electrolysis type is more suitable compare to installation space, total weight and electrical power consumption.

이염화이소시아뉼산나트륨(NaDCC) 주입 선박평형수 처리기술의 해양생태위해성평가에 대한 연구 (A Study on Marine Ecological Risk Assessment of Ballast Water Management Technology Using the Sodium Dichloroisocyanurate (NaDCC) Injection Method)

  • 김태원;문창호;박미옥;전미해;손민호
    • 해양환경안전학회지
    • /
    • 제24권2호
    • /
    • pp.203-214
    • /
    • 2018
  • 이염화이소시아뉼산나트륨(NaDCC) 주입 선박평형수처리설비(BWMS, ballast water treatment system)에 의해 처리된 배출수 내에는 브롬 및 염소계열의 활성물질과 소독부산물질(DBPs, disinfection by-products)들이 포함되어 있다. 본 연구에서는 NaDCC로 처리된 선박평형수가 해양환경에 미치는 생태위해성을 파악하기 위하여 생태독성시험(WET test, whole effluent toxicity test)과 생태위해성평가(ERA, ecological risk assessment)를 수행하였다. 배출수독성 시험종은 규조류(Skeletonema costatum, Navicula pelliculosa), 녹조류(Dunaliella tertiolecta, Pseudokirchneriella subcapitata), 로티퍼(Brachionus plicatilis, Brachionus calyciflorus) 및 어류(Cyprinodon variegatus, Pimephales promelas)로 8개의 해양 및 담수종을 이용하였다. 생태독성시험결과, 규조류 및 녹조류를 이용한 성장저해시험에서만 명확한 독성영향이 나타났으며 해수의 시험 조건에서 무영향농도(NOEC, no observed effect concentration), 최저영향농도(LOEC, lowest observable effect concentration) 및 반수영향농도(EC50, effect concentration of 50 %)는 각각 25.0 %, 50.0 % 및 > 100.0 %로 가장 민감한 영향을 나타냈다. 하지만 로티퍼 및 어류를 이용한 독성시험의 경우 모든 염분 구간에서 독성영향이 나타나지 않았다. 한편, 배출수에 대한 화학물질분석결과, bromate, isocyanuric acid, formaldehyde, chloropicrin과 trihalomethanes (THMs), halogenated acetonitriles (HANs), halogenated acetic acid (HAAs) 등 총 25개의 소독부산물질들이 검출되었다. ERA결과, 25개의 소독부산물질들 중, 지속성(P), 생물축척성(B) 및 생물독성(T)의 특성을 모두 보이는 물질은 없었다. 예측환경농도(PEC, predicted environmental concentration) / 예측무영향농도(PNEC, predicted no effect concentration) 비율은 일반적인 항구 환경에서는 모든 물질이 1.0을 초과하지 않았지만 선박 최 인접지역의 경우 Isocyanuric acid, Tribromomethane, Chloropicrin 및 Monochloroacetic acid가 1.0을 초과하여 위해성이 있을 것으로 나타났다. 하지만 실제 배출수를 이용한 생태독성시험결과의 NOEC (25.0 %)를 적용한 결과 NaDCC로 처리된 선박평형수가 해양에 배출되었을 때 선박 최 인접지역을 포함한 일반적인 항구 환경에 수용 불가한 생태위해성을 가지지 않는 것으로 판단된다.

AHP 기법을 이용한 10,000 TEU 이상 컨테이너선에 적용되는 선박평형수 처리장치 최적제품 선정에 관한 연구 (An Application of AHP for the Selection of Optimum Product of BWTS for over 10,000 TEU Container Ship)

  • 이상원;김동준;서원철
    • 대한조선학회논문집
    • /
    • 제52권5호
    • /
    • pp.395-406
    • /
    • 2015
  • The Ballast Water Treatment System was developed to prevent the unintended transport of unwanted organisms from one region to another as demanded by the IMO (International Maritime Organization). Although various types of BWTS in the world have been developed until now and applied to various ships, there has been no systematic basis for its selection and installation. Currently, the system selection and installation are as per ship owner’s suggestion or by easy installation point of view by the shipyard. In order to organize, systemize and solve problems related to the selection and installation of BWTS, a definitive study has been performed to come up with the best alternative to derive value and criteria which were to be met for vessels which are to be equipped with BWTS. Multiple criteria were compared alongside each other during the course of this study. Accordingly an AHP (Analytic Hierarchy Process) analysis method for A, B and C companies were done for container ships with size 10,000 TEU and above. Equipment type for “A” company is “Filter, UV & TiO2” combined type. For “B” company it is “Filter & UV” combined type. Finally for “C” company it is “Electrolysis” type. Henceforth, the results of this study aims to come up with the optimum way to select the best and the most suitable BWTS for a certain vessel.

해양환경관리 관련 각종 국제협약의 국내 수용 현황 (Domestic Status for Acceptance of Various International Conventions relating to Marine Environment Management)

  • 김광수
    • 해양환경안전학회:학술대회논문집
    • /
    • 해양환경안전학회 2006년도 추계학술발표회
    • /
    • pp.221-237
    • /
    • 2006
  • 각종 국제협약의 채결 및 개정안에 따라서, 특히 73/78 국제해양오염방지협약에 의하여 제정되고 개정되어 온 해양오염방지 협약과 같은 국내법들을 살펴보고 국제협약들의 주요 내용과 비교하였다. 그리고 현존의 국제협약 또는 새로운 국제협약의 새로운 내용 및 최근의 개정내용에 따라서 해양오염방지법과 같은 현행 국내법을 개정하거나 새로운 국내법을 제정하는 몇 가지 대안을 제시하였다. 73/78 국제해양오염방지협약의 부속서 6장을 최근에 대기환경보전법으로 수용하지 않고 해양오염방지법으로 수용하였다. 선박 밸러스트수 배출을 통한 외래유해생물종의 침입을 방지하고 국내 해양생태계와 연안환경을 보호하기 위하여 선박밸러스트수침전물관리협약을 해양오염방지법으로 수용하거나 새로운 법을 제정하여 수용하여야 한다. 선박의 유해한 방오시스템 통제를 위한 국제협약을 유해화학물질관리법으로 수용하기보다는 해양오염방지법으로 수용하여야 한다. 선상 잔유 유성혼합물의 빌지수를 함유한 해철유조선을 선진국에서 개발도상국이나 후진국으로 국가 간 이동하는 것을 방지하기 위하여 유해화학물질의 국가간 이동을 규제하고 금지하는 바젤협약올 해양오염방지법으로 수용함으로써 종국적으로는 세계의 해양환경보전에 기여하여야 한다.

  • PDF

현존선에 자외선 평형수처리장치 설치로 인한 평형수 처리시간 변화에 관한 연구 (A Study on the Difference in Ballasting Time Arising from the Installation of an Ultraviolet Ballast Water Management System on Existing Ships)

  • 서길천;이경우;노범석;조익순;이원주;;최재혁
    • 해양환경안전학회지
    • /
    • 제26권5호
    • /
    • pp.576-585
    • /
    • 2020
  • 본 연구는 기존 선박에 자외선 (UV) 평형수처리장치(BWMS)를 설치 한 경우, 수치 계산을 통해 평형수 처리시간의 증가를 정량적으로 조사하였다. 계산 결과 배수량 55,000톤 가스 운반선의 평형수 처리시간은 UV BWMS 미설치 및 유량 제어 기능 없이 2.152 시간이었다. 평형수 처리시간은 UV BWMS 설치 후 14.2 % 증가했으며, 유량 제어 기능까지 고려 시 20.4 % 증가했습니다. 실제 조건들을 고려하면 UV BWMS 설치 후 평형수 처리시간은 기존 평형수처리시간 대비 최소 30 % 정도 증가할 것으로 예상됩니다. 따라서 업계 관계자는 평형수 처리시간 증가로 인한 선박 운영 손실을 최소화하기 위하여 UV BWMS 선정시 본선의 실제 평형수펌프 용량과 UV BWMS의 유동 에너지 손실을 충분히 고려하는 것이 좋습니다. 또한 BWMS 설치 후 평형수 처리시간 증가를 최소화하기 위해서는 더 큰 용량의 BWMS, 더 큰 파이프 및 내부 코팅이 있는 파이프 등의 사용을 고려할 수 있습니다.

설계 데이터가 손실된 선박에 대한 BWMS 설치 계획 연구 (A Study on BWMS Installation for a Ship without CAD Data)

  • 전송권;최영
    • 한국CDE학회논문집
    • /
    • 제21권1호
    • /
    • pp.1-8
    • /
    • 2016
  • After 2017 years, BWMS units must be installed in the existing ship as well as the new ship by the ballast water management convention. Software tools that can help automatically searching for BWMS installation space to avoid pipes and equipment in the engine room of the existing ship will be very useful in the BWMS layout design. In this study, voxel representation of scanned data is generated first to search space efficiently. Simplified voxel models of each unit are prepared to be located in the engine room space as well. Distance between connected models is calculated through the arrangement direction and position of each model. Sums of distance between connected models are compared for the optimal configuration. It is assumed that the sum of distance between connected models depicts the pipe usage. The proposed method can save the time needed for BWMS installation design and allows optimal configuration of BWMS units.

해수용 기준전극 개발을 위한 겔 타입 내부전해질 제조 및 잔류염소 측정장치에의 적용 (Fabrication of Gel-type Electrolyte for the Development of Reference Electrode for Sea Water and Application to Measuring Equipment for Total Residual Oxidants)

  • 김유진;이해돈;김대원
    • 공업화학
    • /
    • 제28권2호
    • /
    • pp.153-157
    • /
    • 2017
  • Hydroxyethyl-cellulose (HEC) 함량별로 겔 타입 내부전해질을 제작하여 이온전도도와 내구성 측정 실험을 수행하였다. 이온전도도 측정결과 HEC 함량이 증가할수록 이온전도도가 감소하여 12% 함량의 겔 타입 내부전해질은 기준전극에 적용이 어려울 것으로 판단하였다. HEC 함량별 내구성 실험결과, HEC의 함량이 감소할수록 carrier density가 증가하여 다공성 막을 통해 유출되는 전해질(KCl)의 양이 증가하였다. 따라서 선박평형수 처리장치와 같이 장시간 사용하기 위해 겔 타입 내부전해질을 HEC 10%로 선정하였다. HEC 10%의 겔 타입 내부전해질을 이용하여 기준전극과 TRO (total residual oxidants) 센서를 제작하여 TRO 분리능 실험을 수행하였다. TRO 센서에 50 mV의 전위를 30 s 동안 동일하게 인가하여 전류변화를 비교한 결과 0.2~30 PSU 조건에서 0~15 mg/L의 TRO 농도가 분리됨을 확인하였다. 따라서 HEC를 이용한 겔 타입 내부전해질을 TRO 센서에 적용할 수 있으며, 이를 이용하여 담수뿐만 아니라 해수 조건에서 TRO를 측정할 수 있음을 확인하였다.

열산화법으로 생성된 TiO2 중간보호층이 Ti/RuO2-PdO-TiO2전극의 염소발생 효율 및 내구성에 미치는 영향 (Effect of Thermally Grown TiO2 Interlayer on Chlorine Evolution Efficiency and Durability of Ti/RuO2-PdO-TiO2 Electrodes)

  • 박다정;최승목;이규환
    • 한국표면공학회지
    • /
    • 제51권4호
    • /
    • pp.207-213
    • /
    • 2018
  • Not only efficiency of chlorine evolution reaction (CER) but also durability namely service life is very important property in dimensional stable anode for Ballast Water Management System (BWMS) for marine ships. Many researchers have been focused on improving efficiency of CER by controlling composition, phase and surface area for a long time, but the efforts to increase durability was relatively small. In this study, we have investigated the effect of $TiO_2$ protective interlayers on efficiency and durability of DSA electrodes. $TiO_2$ protective interlayers were prepared by thermal oxidation at 500, 600 and $700^{\circ}C$ on Ti substrate. And then the DSA electrodes consisting of $Ti/RuO_2-PdO-TiO_2$ were prepared by thermal decomposition method on $TiO_2$ interlayers. The efficiencies of CER of DSA electrodes without $TiO_2$ interlayer and with $TiO_2$ interlayer grown at 500, 600 and $700^{\circ}C$ were 94.19, 94.45, 84.60 and 76.75% respectively. On the otherhand, durabilities were 30, 55, 90 and 65 hours respectively. In terms of industrial aspect, the performance of DSA is considered high efficiency and durability which can correspond to total production of chlorine. If we considered the performance index of DSA as the product of efficiency and durability, performance indices could be recalculated as 28.26, 50.85, 76.14 and 49.89 respectively. As the thermal oxidation temperature increasing, life time were increased remarkerbly, while efficiency of CER was decreased slightly. As a result, DSA electrode with $TiO_2$ interlayer grown at $600^{\circ}C$ has shown about 2.7 times performace of original DSA electrode without $TiO_2$ interlayer.

잠재적 위해종인 야광충의 항만 분포 특성과 수용능력 (Distributional Characteristics and Carrying Capacity of the Potentially Risky Species Noctiluca scintillans at International Korean Seaports)

  • 강정훈
    • Ocean and Polar Research
    • /
    • 제32권4호
    • /
    • pp.449-462
    • /
    • 2010
  • Ongoing port baseline surveys are essential for developing ballast water management procedures in order to control unwanted or potentially risky species. Seasonal distributional patterns of marine dinoflagellate Noctiluca scintillans internationally recognized as harmful species and the related environmental factors were surveyed at Incheon, Gwangyang and Ulsan seaports in Korea from 2007 to 2009. The above three seaports were chosen because of their status as the busiest in Korea and characterized by their different bioregions. Average temperature ranged from $2.08^{\circ}C$ in winter to $26.39^{\circ}C$ in summer at Incheon, $7.22^{\circ}C$ in winter to $25.77^{\circ}C$ in summer at Gwangyang, and $11.59^{\circ}C$ in winter to $21.67^{\circ}C$ in summer at Ulsan during the study period. Average salinity varied from 26.88 in winter to 31.25 in summer at Incheon, 22.83 in winter to 33.41 in summer at Gwangyang, and 30.04 in winter to 33.90 in summer at Ulsan. Noctiluca scintillans appeared consistently at all ports during the study period, indicating its eurythermal and euryhaline nature. The highest abundances (21,813 to 41,753 $inds{\cdot}m^{-3}$) of N. scintillans were observed in May 2008 and 2009 at the outer stations of Incheon port. Abundances of between 10,000 and 30,000 $inds{\cdot}m^{-3}$ were only observed at the innermost station of Ulsan in May, while abundances of between 10,000 and 40,000 $inds{\cdot}m^{-3}$ were frequently observed throughout all stations at Gwangyang during the study period, coinciding with consistently high concentration of chlorophyll-a (hereafter chl-a) ($4.32-8.24\;{\mu}g\;l^{-1}$) compared to other ports. Spatio-temporal variation of chl-a concentration was not significantly correlated with abundances of N. scintillans (p>0.01). However, relatively high chl-a concentrations were consistently recorded along with high abundances of N. scintillans throughout all stations at Gwangyang compared to other ports. Abundances of N. scintillans observed at the three surveyed ports did not significantly (p>0.01) affect the concentration of dissolved oxygen in the surface mixed layer, indicating that the species abundances were not enough to cause reduction of dissolved oxygen during the study period. Presented results indicated that the Gwangyang seaport may provide the most suitable environment for a wide range of N. scintillans blooming compared to other ports.

선박에 대하여 변화되는 환경규제와 대응책 (Environmental Regulation for ships)

  • 박상호;김인수
    • 한국항해항만학회지
    • /
    • 제28권8호
    • /
    • pp.767-773
    • /
    • 2004
  • 국제해사기구(International Maritime Organization : IMO)에서는 선박에서 발생되는 오염물질 등에 대한 규제강화를 위하여 최근 새로운 해사환경협약의 채택 및 발효를 강력히 추진하고 있다. 우리나라는 국제해사기구의 A그룹 이사국으로서의 국제적인 위상과 해양환경 보호를 위하여 현재 발효되고 추진 중에 있는 협약들에 대한 연구와 대처를 효과적으로 하여야 한다. 이 논문은 해양관련 환경규제협약인 패기오염방지협약, 선박의 유해방오도료 사용규제협약, 밸러스트수 배출규제협약, 선박으로부터 오수에 의한 오염방지를 위한 협약 등의 주요 현안을 파악하고 분석하여 이에 따른 대응책을 제시하고자 한다.