• Title/Summary/Keyword: Ballast

Search Result 1,045, Processing Time 0.023 seconds

Mechanization Scheme for ballast withdrawal from ballast track bed (자갈도상 자갈철거 기계화 방안)

  • Yang, Hoe-Seong;Kong, Sun-Yong;Kong, Bak-Jin
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1029-1037
    • /
    • 2008
  • As for track maintenance, Seoul Metro executes track bed improvement project from obsolete ballast track bed to concrete track bed in order to achieve maintenance free and to extend its LCC(Life Cycle Costing). When it comes to obsolete ballast track bed withdrawal task, now it is done solely relying on man power and ballast inhalation vehicle. In this paper, I suggested ballast cleaning system with lighter equipment to change manpower withdrawal tasks to mechanized ones. It is expected to improve work efficiency and economic benefits by applying track excavator having variable wheels and container etc, which is able to keep on the site.

  • PDF

The Cost-effective Eletronic ballast for Metal halide Lamp using DSP (DSP를 이용한 비용 절감형 메탈할라이드 램프용 전자식 안정기)

  • Han, Sang-Soo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.4
    • /
    • pp.108-112
    • /
    • 2017
  • High-intensity-discharge lamps are widely utilized in outdoor and indoor lighting circumstances that need high luminance. In lighting applications for MHD lamps, the size of the lamp ballast circuit is an important factor and should be as small as possible. The electronic ballast for MHD lamps is superior to the electromagnetic(EM) ballast in that it saves energy, and has smaller volume and lighter weight. In this paper, highly efficient cost-effective and small sized electronic ballast for Metal Halide Lamp with high power factor using Digital Signal Processor are proposed. The proposed electronic ballast for MHD lamps combines a boost PFC converter with a half-bridge inverter, the algorithms of the power factor correction and ballast control were implemented using the TI's TMS320LF2406 CPU. Experimental results validate the ballast is also useful and reasonably suggested.

Optimization of Ballast Depth of Ballasted Track Bridges to Improve Ride Comfort (승차감 향상을 위한 유도상교량의 도상두께 최적화)

  • Kim, Kwan-Hyung;Kwon, Soon-Jung;Kim, Yun-Tae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.6D
    • /
    • pp.867-874
    • /
    • 2011
  • The ballast abrasion occurs on the ballasted track upon bridges more than soil roadbed because the track vibration occurs a lot in the ballasted track upon bridges due to girder vibration when a train's weight is loaded onto track even though the identical ballast is used. The phenomena of mud pumping especially, which occurs when drainage is not properly secured for heavy rain, leads to the increase of maintenance work load and the decline of ride comfort. The ballast thickness range in domestic railroad construction rule is uniformly set up according to the design speed of railroad and passing tonnage of train without considering field conditions which is considered in foreign railroad companies. The purpose of this study is to verify the effect of vibration decrease by measuring the acceleration, displacement and ride comfort of ballasted track with the change of ballast thickness on the ballast tracked bridges and to suggest the optimal height of ballast on the Yocheon Bridge built for the test in Honam Line.

Development of an Ultra-Violet Lamp and a Ballast for Ship's Ballast Water Treatment (선박평형수 처리용 자외선 램프 및 안정기 개발)

  • Cheon, Sang-Gyu;Park, Dae-Won;Kil, Gyung-Suk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.675-681
    • /
    • 2011
  • In this paper, we dealt with the design and fabrication of a medium pressure ultra-violet (UV) lamp and a magnetic ballast which are main components for ballast water treatment systems (BWTS). To acquire an optimal discharge condition of UV lamp, electrical and optical characteristics depending on the argon gas volume and the amount of mercury were experimentally analyzed. Rated voltage, current and power consumption of a prototype lamp were 490 [V], 8.6 [A] and 4.0 [kW], respectively. UV intensity of the lamp was 15 [%] higher than that of an equivalent lamp which is used in a BWTS. The magnetic ballast was designed in a UI core type through theoretical analysis and simulation. The open voltage and the rated power consumption of the ballast were 920 [V] and 8.5 [kVA] respectively. The disinfection efficacy which is carried out in a BWTS equipped with the UV lamp and magnetic ballast was over 99.99 [%], and this satisfy the IMO regulations.

A study on the distribution of organic compounds, nitrogen, phosphorus and heavy metal in Ballast Water (밸러스트수내 유기물, 영양염류 및 중금속 농도 분포에 관한 연구)

  • Cheong, Kwang-Hyun;Ahn, Jong-Gil
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.05a
    • /
    • pp.71-77
    • /
    • 2006
  • There is a growing concern about the damage to aquatic ecosystem caused by immigration of non-indigenous species. It is estimated that more than 10,000 million tons of ballast water is transported by shipping activities annually, and ballast water has been recognised as a major vector for the transplant of aquatic species across bio-geographical boundaries. The problem of harmful aquatic organism in ballast water for the control and management of ships' ballast water and sediments was adopted and diplomatic conference of IMO at February 2004. At once ballast water is transported by shipping activities for organic compounds, nitrogen, phosphorus and heavy metal etc. but, It's fixing a focus only for the transported of pathogenic bacteria and non-indigenous species. Hence, this studies on the distribution of organic compounds, nitrogen, phosphorus and heavy metal in ballast water during the shipping activity with the basic data which is necessary to the systemic manage of ballast water.

  • PDF

Electronic Ballast for Metal Halide Lamps Using High Frequency Modulation Method (고주파 변조방법을 이용한 메탈할라이드 램프용 전자식 안정기)

  • 오덕진;문태환;조규민;김희준
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.5
    • /
    • pp.438-445
    • /
    • 2001
  • This paper presents a high frequency modulation electronic ballast for the metal halide lamp. As the proposed ballast operates in high frequency ranges and can start up the lamp using the LC resonant circuit without external igniter, the proposed ballast is very compact and has a good efficiency in comparison with the conventional low frequency electronic ballast. The proposed ballast is controlled with the modulated frequency in the range of 20kHz to 100kHz in order to avoid the acoustic resonance phenomenon. In this paper, a new realtime acoustic resonance detection method is proposed to evaluate the characteristics of the ballast. The no load protection algorithm and power control algorithm through the detection of the DC link current are described. Finally, the experimental results on the proto-type ballast of 150w metal halide lamp with the proposed methods are discussed.

  • PDF

Electrical Characteristics and Discharge Condition of Ceramic Metal Halide Lamp with Operating Property (구동특성에 따른 세라믹 메탈 할라이드 램프의 전기적 특성 및 방전현상에 관한 연구)

  • Jang, Hyeok-Jin;Kim, Nam-Gon;Yang, Jong-Kyung;Kim, Woo-Young;Park, Hyung-Jun;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.388-389
    • /
    • 2009
  • The use of arc tubes made of ceramic material further enhanced some of the metal halide lamp's properties. These properties translate into higher efficacy with better color rendering, stable color through lamp long life. Recently, due to an increase in the application of the ceramic metal-halide lamp, the study for the property etc. according to Ballast's driving scheme and the study for arc tube material, optimization of gas and so on are being proceeded to improve the property of the lamp. Especially, to control ceramic metal-halide lamp, the vigorous study and practical use with respect to Electronic Ballast, which has been improved in the disadvantages of the conventional Magnetic Ballast are made. In this paper, Electrical characteristics and gas insulation destroy time are analyzed by comparing magnetic ballast with electronic ballast.

  • PDF

Development of an Electronic Ballast for 70W Ceramic Discharge Metal Halide Lamps with Step Down Converter (강압형 컨버터를 이용한 70W CDM 램프용 전자식 안정 기의 개발)

  • 김일권;길경석;김진모
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.7
    • /
    • pp.1055-1061
    • /
    • 2002
  • This paper deals with a design and fabrication of an electronic ballast for 70[W] ceramic discharge metal halide lamps. The proposed ballast is composed of a rectifier, an active power factor correction circuit (PFC), a half-bridge inverter, a LC resonant circuit and a microprocessor. The developed ballast also includes a specially designed time circuit which provides reignition signal of lamps. Running frequency of the ballast is .jet at 40[kHz] to avoid acoustic-resonance and flickering. From the experimental results, input power factor and efficiency of the ballast are estimated 99.8[%] and 93.1[%], respectively.

Land Based Test of Ballast Water Treatment System by Ozonation

  • Park, Sung-Jin;Yoon, Seung-Je;Kim, In-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.3
    • /
    • pp.383-390
    • /
    • 2010
  • This study is currently giving priority to developing the ship's ballast water treatment system using ozone (Ozone BWTS). The Ozone BWTS was tested in a full scale land-based mobile barge to evaluate performance according to the IMO G8 Guidelines. Test cycles using the mobile-barge were conducted in seawater and brackish water in the vicinity of the Port of Busan and Nakdong River, Republic of Korea. All tests were conducted according to the requirements of the G8 Guidelines. Test results show that the Ozone BWTS meets the Ballast Water Performance Standard contained in Regulation D-2 of the IMO Ballast Water Management Convention, as well as all of the operational, safety, and environmental testing requirements of the G8 Guidelines, as required for type approval of IMO. The study results show that the Ozone BWTS is capable of meeting the Ballast Water Performance Standard under Regulation D-2 of the International Convention for the Control and Management of Ships’ Ballast Water and Sediments, and also the more stringent standards being proposed under US legislation.

An Experimental and Analytical study on the Steel Plate Girder Railway bridge in the applying External Post-tensioning Method (강철도교에 대한 외부 후긴장 보강공법의 적용에 관한 실험 및 해석적 연구)

  • Park, Young-Hoon;Cho, Sun-Kyu;Choi, Jung-Youl;Park, Yong-Gul
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.2 s.33
    • /
    • pp.151-159
    • /
    • 2006
  • It analyzed the mechanical behaviors of non-ballasted railway bridge (steel plate girder type) with ballast reinforced on the finite element analysis, field test and laboratory test far the static and dynamic responses. The major objective of this study is to investigate the effects and application of reinforcement for steel plate girder railway bridge by the external post-tensioning method. The reinforcement of non-ballast railway bridge had obviously stable dynamic behaviors due to the additional dead force which was ballast. But in case of static behaviors, static displacements and stresses had increased nearly the allowable values. Therefore we analyzed the mechanical behaviors of non-ballasted railway bridge with ballast reinforced and external post-tensioning reinforced on the finite element analysis and laboratory test for the static and dynamic behavior. As a result, the reinforcement of ballasted railway bridge the external post-tensioning method are obviously effective for the additional dead force which is ballast. The analytical and experimental study are carried out to investigate the post-tension force decrease bending behavior and deflection in composite bridge for serviceability. The servicing railway bridge with ballast reinforced has need of the reasonable reinforcement measures which could be reducing the effect of additional dead load that degradation phenomenon of structure by an unusual. stresses and a drop durability.