• Title/Summary/Keyword: Ball-on-3-ball test

검색결과 331건 처리시간 0.026초

반구상의 나선형 볼바측정을 통한 공작기계 오차해석의 역기구학적 접근 (A Reverse Kinematic Approach for Error Analysis of a Machine tool Using Hemispherical Helix Ball bar test)

  • 양승한;김기훈
    • 한국정밀공학회지
    • /
    • 제18권3호
    • /
    • pp.143-151
    • /
    • 2001
  • Machine tool errors have to be characterized and predicted to improve machine tool accuracy. A real-time error compensation system has been developed based on volumetric error synthesis model which is composed of machine tool errors. This paper deals with new algorithm about verification of machine tool errors. This new algorithm uses a simplified volumetric error synthesis model. This simplified model is constructed with only main components among the error components of the machine. The main error components are analyzed by ball bar test of hemispherical helix. The novel measurement method using ball bar system has many advantages which are more efficient, easier to use than conventional measurement system.

  • PDF

풍쇄전로슬래그의 연직배수재 활용성에 관한 실험적 연구 (An Experimental Study on the Applicability of Precious Slag Ball as Vertical Drains)

  • 권정근;임종철;김우경
    • 한국지반환경공학회 논문집
    • /
    • 제12권3호
    • /
    • pp.37-46
    • /
    • 2011
  • 연직배수재로의 대체재로 풍쇄전로슬래그의 적용가능성을 판단하기 위해서는 현장시공을 통해 배수효과를 확인하는 것이 필요하다. 그러나 성공적인 설계를 위해서는 현장시공 전에 발생가능한 문제점들을 미리 예측하는 것이 중요하다. 따라서, 본 연구에서는 현장시공 전 다양한 조건에서 발생가능한 문제점들을 분석하기 위해 실내모형실험을 실시하였다. 실내모형실험은 연직배수재로 풍쇄전로슬래, 모래+풍쇄전로슬래그, 팩슬래그, 모래 총 4경우에 대해 실험을 수행하였으며, 실내모형실험결과를 바탕으로 현장시험시공을 실시하여 분석하였다. 실내모형실험과 현장시험시공을 통해 연직배수재용 모래대용으로 풍쇄전로슬래그가 사용가능한 것으로 판단되었다.

Evaluation of Tensile Properties of Cast Stainless Steel Using Ball Indentation Test

  • Kim Jin Weon
    • Nuclear Engineering and Technology
    • /
    • 제36권3호
    • /
    • pp.237-247
    • /
    • 2004
  • To investigate the applicability of automated ball indentation (ABI) tests in the evaluation of the tensile properties of cast stainless steel (CSS), ABI tests were performed on four types of unaged CSS and on 316 stainless steel, all of which had a different microstructure and strength. The reliability of ABI test data was analyzed by evaluating the data scattering of the ABI test and by comparing tensile properties obtained from the ABI test and the tensile test. The results show that the degree of scattering of the ABI test data is reasonably acceptable in comparison with that of standard tensile data, when two points data that exhibit out-of-trend are excluded from five to seven points data tested on a specimen. In addition, the scattering decreases slightly as the content of ${\delta}-ferrite$ in CSS increases. Moreover, the ABI test can directly measure the flow parameters of CSS with error bounds of about ${\pm}10\%$ for the ultimate tensile stress and the strength coefficient, and about ${\pm}15\%$ for the yield stress and the strain hardening exponent. The accuracy of the ABI test data is independent of the amount of ${\delta}-ferrite$ in the CSS.

Effects of Elastic Band Exercise Combined with Swiss Ball Exercise on Lower Extremity Muscle Strength, Balance, and Pain in Middle-Aged Women with Osteoarthritis

  • Yohan Yoo;Jongeun Yim
    • Physical Therapy Rehabilitation Science
    • /
    • 제12권3호
    • /
    • pp.355-364
    • /
    • 2023
  • Objective: The aim of this study is to test the effects of elastic band exercise accompanied by Swiss ball exercise on lower limb muscle strength, balance and pain in middle-aged women with osteoarthritis. Design: A randomized controlled trial. Methods: Thirty-five participants were randomly assigned to the experimental group (n=18), which performed elastic band exercise combined with Swiss ball exercise, and the control group (n=17), which performed elastic band exercise only. Both groups did a 30-minute session of exercise three times a week for eight weeks and were assessed for lower extremity muscle strength, static and dynamic balance, and pain levels before the first therapy session. All participating patients underwent outcome assessment after eight weeks of therapy without any additional treatment. Results: The experimental group made a significant increase in muscle strength of the lower extremities, static and dynamic balance ability, and pain level (p<0.05). The control group made a significant improvement in lower limb muscle strength, dynamic balance ability and pain level (p<0.05) with no such improvement in static balance ability. The exercise group made a significant increase in static and dynamic balance ability and pain level compared to the control group (p<0.05). Conclusions: These results demonstrated that both Swiss ball exercise and elastic band exercise were effective for middle-aged women with osteoarthritis and found that elastic band exercise combined with Swiss ball exercise produced more significant effects on their balance and pain.

역전 유동층에 의한 슬러리아이스 생성에 관한 연구 (A study on formation of slurry ice by the reversing flow)

  • 오철;문성배;최영규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권3호
    • /
    • pp.376-381
    • /
    • 2006
  • This study is experimented to observe an influence of experimental conditions on production characteristics of slurry ice by putting ball into test section to disturb ice adhesion. And at this experiment it used ethylene glycol-water solution and the concentration is 20wt%. The experimental apparatus was constructed of ethylene glycol-water solution and slurry ice storage tank. brine tank, pumps for ethylene glycol-water solution and brine circulating, a mass flow-meter data logger for fluid temperature measuring and a vertical circular tube with two copper tubes as test section. The experiments were carried out under various conditions, with mean velocity of fluid at the entry ranging from 0.07 to 0.13m/s and ball diameter is 10mm, 15mm. Also ball filling rate is 33%, 50%.

$WS_2$고체윤활제의 합성 및 구름베어링 적용 (Synthesis of $WS_2$ Solid Lubricant and Its Application to Ball Bearing)

  • 신동우;윤대현;최인혁;김경도;정진수;정용선
    • Tribology and Lubricants
    • /
    • 제15권1호
    • /
    • pp.77-82
    • /
    • 1999
  • The processing conditions fur the synthesis of platelet W $S_2$ lubricant powder through a solid-gas reaction were optimized. The mixture of tungsten and sulfur powders were sealed in a vacuum of 10$^{-6}$ torr, prior to heat-treating at 85$0^{\circ}C$ fur 8 days. The reaction product showed a well-developed platelet W $S_2$ powder with an average size of 3.8 ${\mu}{\textrm}{m}$. The TGA/DTA analysis of the synthesized W $S_2$ powder was performed up to 120$0^{\circ}C$ at a rate of 1$0^{\circ}C$/min in flowing air (100 ${\mu}{\textrm}{m}$/min) atmosphere. The weight loss was about 6% up to 120$0^{\circ}C$ compared to the original weight. A rapid weight loss of about 5% occurred in the temperature range of 44$0^{\circ}C$ to 66$0^{\circ}C$ and an exothermic peak observed due to the transition of W $S_2$ to W $O_3$. The synthesized W $S_2$powder was coated on the commercial deep grooved ball bearing (No. 6203) to examine the effect of W $S_2$, coating layer on the noise and endurance of the ball bearing. The level of noise obtained from W $S_2$, coated-ball bearing (56 ㏈) was higher. than the value (32 ㏈) occurred in the case of greece lubrication. The endurance of the ball-bearing assembled after the coating of W $S_2$ powder onto each part increased 50 times compared to the non-coated ball-bearing..

선 자세에서 짐볼 운동이 뇌졸중 환자의 근력, 균형, 보행 및 낙상 효능감에 미치는 효과 (Effects of Gym-ball Exercise in Standing Position on Muscle Strength, Balance, Gait and Fall Efficacy in Stroke Patients)

  • 임윤정;강순희
    • 대한통합의학회지
    • /
    • 제10권1호
    • /
    • pp.49-60
    • /
    • 2022
  • Purpose : The purpose of this study was to identify whether gym-ball exercise in standing position was an effective intervention for improving muscle strength, balance, gait, and fall efficacy in stroke patients. Methods : Twenty-four stroke patients were randomized into three groups: experimental group 1 (n=8), experimental group 2 (n=8), and control group (n=8). Experimental groups 1, 2 and the control group performed the gym-ball exercise in standing position, same exercise without a gym-ball, and general physical therapy for 4 weeks, five times a week in 30-minute sessions. Muscle strength, balance, gait, and fall efficacy were assessed using a handheld dynamometer, the Berg Balance Scale (BBS), the wearable BTS G-WALK® sensor, and the Korean version of the Falls Efficacy Scale (K-FES), before and after training, respectively. Comparisons within and between groups were analyzed using the Wilcoxon signed rank test, Kruskal Wallis H test, and Mann-Whitney U test. Bonferroni correction was performed when significant differences between groups were identified (p<.017, .05/3). Results : Regarding muscle strength, BBS score, cadence and FES-K were significantly improved after intervention in all three groups. The weight bearing rate, gait speed and step length in experimental group 1 and 2 were significantly improved after the intervention. The stride length in experimental group 1 were significantly improved after the intervention. Experimental group 1 had significantly improved BBS score and stride length after intervention than experimental group 2 and control group. Experimental group 1 and 2 improved muscle strength, weight bearing rate, and FES-K score more than the control group. Experimental group 1 showed significant improvement in cadence, gait speed, and step length after the intervention than control group. Conclusion : This study showed that exercise with gym-ball in standing position can be an effective intervention to improve balance and gait in stroke patients than the same exercise without gym-ball.

경제윤활하에서 질화규소몰의 미세구조 및 조성이 구름피로수명에 미치는 영향 (Effect of Composition and Microstructure of Si$_3$N$_4$ Ball OH Rolling fatigue Life under Boundary Lubrication)

  • 최인혁;송복한;신동우
    • Tribology and Lubricants
    • /
    • 제16권6호
    • /
    • pp.477-483
    • /
    • 2000
  • Rolling contact fatigue (RCF) tests were performed for two kinds of commercial silicon nitride balls using 4-Ball rolling contact fatigue life tester under EHL condition (Λ=8.9) and boundary lubrication condition (Λ=0.2). All the test balls were finished up to the dimensional accuracy of Grade 5 defined in KS B 2001 (Steel Balls for Ball Bearings) with a size of 8.731 mm. RCF tests were then conducted under the initial theoretical maximum contact stress 6.63 GPa and the spindle speed 10,000 rpm. All the test balls were not failed until 3.75 $\times$ 107 contact cycles and wear tracks of test balls were not conspicuous under EHL condition (Λ= 8.9). In the operations of low lambda regime (Λ= 0.2), all the test balls were surface damaged and high rolling wear resistance was achievable in fully densified using MgO 1 wt% and HIPed balls. Rolling wear of silicon nitride balls under boundary lubrication condition depend mainly on grain size and intergranular phase content of silicon nitride balls.

굴착토를 활용한 속경성 유동성 채움재의 공학적 특성 평가 (Engineering Characteristics Assessment of Rapid Set Controlled Low Strength Material for Sewer Pipe Using Excavated Soil)

  • 김영욱;이봉춘;정상화
    • 한국건설순환자원학회논문집
    • /
    • 제8권4호
    • /
    • pp.450-457
    • /
    • 2020
  • 본 연구에서는 현장 굴착토를 활용한 속경성 유동성 채움재의 배합요인별 유동성, 재료분리 저항성, 재령별 압축강도 등의 공학적 특성을 검토하여 속경성을 발현하는 배합비 및 결합재 조건을 도출하였으며, 이를 토대로 현장 모사 실험을 실시하여 현장에서 적용 가능한 후속공정 개시기 검토 방법의 유효성을 검토하고자 하였다. Kelly ball 낙하시험과 산중식 토양 경도계의 평가결과 유동성 채움재의 후속공정 개시기 확보 가능한 시간은 동일하게 약 3시간으로 나타났으며, 일축압축강도 시험의 결과와 비교하였을 때 Kelly ball 낙하 시험 및 산중식 토양경도계의 현장 적용성에 대한 유효성을 확인할 수 있었다.

3차원 요부안정화 운동이 20대 요통환자의 통증과 동적 및 정적 균형능력 향상에 미치는 효과 (The Effects of 3-Dimensional Lumbar Stabilization Exercise have an effect on the improvement of pain and static or dynamic balance ability in 20's age group with Low Back Pain)

  • 김규용;안창식;김성수
    • 대한물리의학회지
    • /
    • 제6권2호
    • /
    • pp.235-246
    • /
    • 2011
  • Purpose: The aim of this study is to compare and assess the effects of lumbar stabilization exercise on the balance ability of young college studets with low back pain after having performed spinal stabilization exercise by using 3-dimensional air-balance system and gym ball. Methods: The subjects of this study were 34 low back patients in their early twenties. They were divided into two groups: 3-dimensional lumbar stabilization exercise group(N=17) and gym ball lumbar stabilization exercise group(N=17). The period of the intervention was for five weeks. VAS(Visual Analogue Scale) for pain test, ODI(Oswestry Disability Index) for ADL limitation test, Tetrax system for static balance test, and Air-balance system 3D for dynamic balance test were used as evaluation tools for this study. Results: Pain showed significant decrease in both groups after having performed the experiment, but ADL limitation of the groups did not show any remarkable difference between before and after the experiment. Dynamic balance ability in the 8-directional angle comparison test significantly increased in all directions except for the backward, left-backward, and right-backward directions. As for dynamic balance ability in the 8-directional postural test, 3D exercise group showed statistically significant reduction in every direction while gym ball exercise group did not(p<.05). However, when it comes to static balance ability in the weight distribution and stability test, there was not significantly change between pre and post test in both groups. Conclusion: This study shows 3-dimensional lumbar stabilization exercise is more effective in the lumbar stabilization of coordinated movement than gym ball exercise, which may imply that 3D air-balance system can be used for the therapeutic treatment of body imbalance for patients with low back pain.