• 제목/요약/키워드: Balance recovery

검색결과 249건 처리시간 0.026초

Effects of treadmill training with real optic flow scene on balance and balance self-efficacy in individuals following stroke: a pilot randomized controlled trial

  • Kang, Hyungkyu;Chung, Yijung
    • Physical Therapy Rehabilitation Science
    • /
    • 제1권1호
    • /
    • pp.33-39
    • /
    • 2012
  • Objective: The objective of this study is to investigate the effect of treadmill training with real optic flow scene on functional recovery of balance and balance self-efficacy in stroke patients. Design: Single blind, Randomized controlled trial. Methods: Nine patients following stroke were divided randomly into the treadmill with optic flow group (n=3), treadmill with virtual reality group (n=3), and control group (n=3). Subjects in the treadmill with optic flow group wore a head-mounted display in order to receive a speed modulated real optic flow scene during treadmill training for 30 minutes, while those in the treadmill with virtual reality group and control group received treadmill training with virtual reality and regular therapy for the same amount of time, five times per week for a period of three weeks. Timed up and go test (TUG) and activities-specific balance confidence scale (ABC scale) were evaluated before and after the intervention. Results: TUG in the treadmill training with optic flow group showed significantly greater improvement, compared with the treadmill training with virtual reality group and control group (p<0.05). Significantly greater improvement in the ABC scale was observed in the treadmill training with optic flow group and the tread mill training with virtual reality group, compared with the control group (p<0.05). Conclusions: Findings of this study demonstrate that treadmill training with real optic flow scene can be helpful in improving balance and balance self-efficacy of patients with chronic stroke and may be used as a practical adjunct to routine rehabilitation therapy.

  • PDF

Effects of Plastic AFO and Shoes on Static Standing Balance in Hemiplegic Patients (플라스틱 단하지 보조기와 신발 착용이 편마비 환자의 정적 선자세 균형에 미치는 영향)

  • Kim, Joong-Hwi;Kim, Chung-Sun
    • The Journal of Korean Physical Therapy
    • /
    • 제13권2호
    • /
    • pp.381-397
    • /
    • 2001
  • In the patients with hemiplegia caused by stroke and TBI. postural sway is increased and open displaced laterally over the non-affected leg, reflecting asymmetry in weight bearing on lower extremities during standing balance. Recovery of symmetric weight bearing and postural stability is an important aim in physical therapy. Plastic AFO has been used for hemiplegic patients in order to help their abnormal walking patterns. Past studies have mainly focused on the AFO influences on hemiplegic walking patterns without balance function approaches. The purpose of this study was to identify the immediate effects of plastic AFO and shoes on the static balance in hemiplegic patients. The scale for static balance were weight bearing on affected leg(%), sway area(mm2), sway path(mm), maximal sway velocity(mm/s), anteroposterior sway angle($^{\circ}$ ), and lateral angle($^{\circ}$ ). Seventeen hemiplegic patients participated in this study: 13 men and 4 women, with an average age of 50.18 years. Static balance was measured using BPM(balance performance monitor; dataprint software version 5.3) under four standing condition namely bare-foot standing. standing in shoes, standing with AFO, and standing in shoes with AFO. In order to assure the statistical significance of the results, an one-way ANOVA, the independent t-test. and a pearson's correlation were applied at the .05 level of significant. The results of this study were as follows: 1) There were statistically significant differences in weight bearing(%) on the static balance between affected leg and non-affected leg(p<.01). 2) There were statistically significant differences in sway reverse frequence(Hz) in standing with AFO between affected leg and non-affected leg(p<.05). 3) Sway area(mm2) on standing in shoes with AFO was lower than bare-foot standing(p<.05), Lateral sway angle($^{\circ}$ ) on standing in shoes with AFO was lower than bare-foot standing and standing in shoes(p<.05). 4) Weight bearing in affected leg was not significantly correlated with postural sway.

  • PDF

The Effect of the Combined Exercise Program on the Static Balance Ability of the Lumbar Instability of Adults (허리 불안정성을 가진 성인에게 적용한 복합운동프로그램이 정적균형능력에 미치는 영향)

  • Oh, Yoon-joong;Park, Jong-hang;Kim, Yoon-hwan;Kim, Tae-won
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • 제25권2호
    • /
    • pp.21-29
    • /
    • 2019
  • Background: The purpose of this study is to investigate the effect of the combined exercise program on the static balance ability of the lumbar instability of adults. Methods: The experimental group was divided into two groups and randomly. The experimental group 1 (Exp 1) applied the combined exercise program for the lumbar stabilization exercise and strengthening exercises and the experimental group 2 (Exp 2) applied the combined exercises program for the lumbar stabilization exercises and active stretching exercises. Each experiment group performed exercise program for 4 weeks, 3 times a week, 30 minutes a day. Static balance ability was measured using GOOD BALANCE system. Results: As the comparing results of static balance ability, normal standing eye open was Ant-Post and Med-Lat showed significant differences in Exp 1 (p<.05). One leg left eye open was velocity moment showed significant differences in Exp 1 (p<.05). and one leg right eye open was Med-Lat showed significant differences in Exp 1 (p<.05). Conclusion: These results show that thoracic self mobilization is immediate effective on balance and gait ability. Thus, thoracic self mobilization will help recovery of balance and gait ability in acute stroke patients.

Affects of Pilates Exercise Program on Balance Ability and Activities of Daily Living(ADL) Performance Ability for Patient With Chronic Cerebellum Infarction (필라테스 운동 프로그램이 만성 소뇌경색 환자의 균형능력과 일상생활활동 수행능력에 미치는 영향: 단일 사례연구)

  • Ruy, Sung-Hyun;Cho, Young-Nam
    • Therapeutic Science for Rehabilitation
    • /
    • 제2권1호
    • /
    • pp.77-86
    • /
    • 2013
  • Objective : The purpose of this study is to assess affects of pilates exercise program on balance ability and ADL performance ability of patient with chronic cerebellum infarction. Methods : The object of this study K-hospital located in daegu, 62-year-old woman who have receiving inpatient treatment with cerebellum infraction. Before and after the intervention in order to compare balance ability was assessed using berg balance scale(BBS) and ADL performance ability was assessed by modified barthel index(MBI). Results : Balance ability of the object score improved from 19 to 29, the ADL performance ability score increased from 74 to 87. Conclusion : The result of this study pilates exercise program in patients with chronic cerebellum infarction balance ability and ADL performance ability to promote was found that the effect. this pilates exercise program in the occupational therapy, if appropriately utilized more on the functional recovery of patients is expected to be helpful.

Relationship between Kinesiotaping and compression wear for postural balance in healthy men: a cross-sectional study

  • Choi, Nak-Hoon;Hwang, Sujin
    • Physical Therapy Rehabilitation Science
    • /
    • 제9권4호
    • /
    • pp.275-280
    • /
    • 2020
  • Objective: Compression wear is an external aid which promotes performance and recovery, diminishes muscular microtrauma, reduces muscle fiber recruitment, improves neuromechanics, enhances coordinative activities, and reduces the perceived exertion. The purpose of this study was to investigate the relationship between athletic taping and compression wear on dynamic postural balance in healthy young men. The hypothesis was that the athletic taping and compression wear would affect dynamic postural balance, with athletic taping having a different effect on dynamic postural balance in healthy young adults. Design: Cross-sectional study. Methods: Thirty-seven healthy young men participated in this study. To examine the association between athletic taping and compression wear, 3 clinical measurement tools, including 5 times sit-to-stand (5xSTS), one-leg standing (OLS) test, and Y-balance test (YBT) in 5 different conditions, namely (1) non-supporting, and support with (2) athletic taping, (3) regular compression wear, (4) silicon compression wear, and (5) double-fiber compression wear were used. Results: The distance of the Y-balance test (YBT) on both the dominant and non-dominant sides showed a statistically difference among the 5 supporting conditions (p<0.05). The distance measured via the YBT in the non-support condition was significantly different than that in the other four supporting conditions (p<0.05). However, 5xSTS and OLS were not significantly different in these supporting conditions. Conclusions: The results of this study suggest that athletic taping, silicon compression wear, and double-fiber compression wear were more effective for dynamic balance than non-supporting and regular compression wear.

Effects of Warm-up Performance on SI Engine with Exhaust Heat Recovery System (배기열 회수장치 적용에 따른 SI 엔진의 웜업 성능에 미치는 영향)

  • Park, Kyoun-Suk;Suh, Ho-Cheol;Park, Sun-Hong;Kim, In-Tae;Jang, Sung-Wook
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • 제19권6호
    • /
    • pp.53-60
    • /
    • 2011
  • The effect of exhaust heat recovery system can be evaluated by two well known method. First method is to measure the time duration from engine start under cold coolant temperature till coolant get warmed. By this methodology coolant warming duration can be index of warm-up effect. Second method is to analyze heat balance of the engine during warm-up phase under steady engine operation so that wasted energy by losses such as cooling and exhaust can be index of warm-up effect. This study focused on evaluation of warming-up effect by both methodology above mentioned using 2L SI engine under from idle to 2000rpm steady condition. Results, idle operation showed low heat recovery efficiency but under higher engine speed condition, remarkable heat recovery efficiency improvement was observed. In 2000rpm steady condition, warm-up duration of engine is decreased by exhaust heat recovery system.

The Improvement of Translucent Cryptography (Translucent Cryptography의 취약점 개선)

  • 김종희;이필중
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제27권12C호
    • /
    • pp.1276-1281
    • /
    • 2002
  • Bellare and Rivest proposed the translucent cryptography which was a kind of key recovery system. Translucent cryptography is a system in which the third party can recover encrypted message with the probability p(0$\leq$p$\leq$1). The key recovery agency doesn't need to store the user's private key in advance. The balance between key recovery agency and user can be controlled by the value of p. For example, if p is set to be 0.4 then the key recovery agency can recover 40 out of 100 encrypted messages. In this paper, we show that user can easily deceive the key recovery agency in the translucent cryptography. Then we propose the solution of this problem.

Thermal and Flow Analysis of Organic Rankine Cycle System Pipe Line for 250 kW Grade Waste Gas Heat Recovery (250kW급 폐열회수 시스템용 유기랭킨사이클 배관 열유동해석에 관한 연구)

  • Kim, Kyoung Su;Bang, Se Kyoung;Seo, In Ho;Lee, Sang Yun;Yi, Chung Seob
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • 제18권4호
    • /
    • pp.26-33
    • /
    • 2019
  • This study is a thermal and flow analysis of Organic Rankine Cycle (ORC) pipe line for 250 kW grade waste gas heat recovery. We attempted to obtain the boundary condition data through the process design of the ORC, which can produce an electric power of 250 kW through the recovery of waste heat. Then, we conducted a simulation by using STAR-CCM+ to verify the model for the pipe line stream of the 250 kW class waste heat recovery system. Based on the results of the thermal and flow analyses of each pipe line applied to the ORC system, we gained the following conclusion. The pressure was relatively increased at the pipe outside the refracted part due to the pipe shape. Moreover, the heat transfer amount of the refrigerant gas line is relatively higher than that of the liquid line.

Capture and Reduction Technology of Greenhouse Gas Using Membrane from Anaerobic Digester Gas (분리막을 이용한 혐기성 소화가스로부터 온실가스 회수저감 기술)

  • Hwang, Cheol-Won;Jeong, Chang-Hun
    • Journal of Environmental Science International
    • /
    • 제20권10호
    • /
    • pp.1233-1241
    • /
    • 2011
  • The main objective of this experimental investigation was $CH_4$ recovery from biogas generated in municipal and wastewater treatment plant. The polysulfone hollow fiber membrane was prepared in order to investigate the permeation properties of $CH_4$ and $CO_2$. Permeability of $CO_2$ in Polysulfone membrane was 11-fold higher than of $CH_4$ gas. A membrane pilot plant for upgrading biogas was constructed and operated at a municipal wastewater treatment plant. The raw biogas contained 66 ~ 68 Vol % $CH_4$, the balance being mainly $CO_2$. The effect of the operating pressure of feed and permeate side and feed flowrate on $CH_4$ recovery concentration and efficiency were investigated with double stage membrane pilot plant. The $CH_4$ concentration in the retentate stream was raised in these tests to 93 Vol % $CH_4$.

Optimization of Solid Phase Extraction Method for Quantitative Analysis of Perfluorooctanoic Acid in Serum using Liquid Chromatography-Tandem Mass Spectrometry

  • Lee, Hyun-Seok;Yim, Yong-Hyeon
    • Mass Spectrometry Letters
    • /
    • 제5권1호
    • /
    • pp.30-33
    • /
    • 2014
  • A solid phase extraction (SPE) method was optimized for the quantitative analysis of perfluorooctanoic acid (PFOA) in serum using hydrophilic-lipophilic balance SPE and LC-MS/MS. Fetal bovine serums spiked with $^{13}C_8$-PFOA before or after SPE were used as test samples for evaluation of the SPE efficiency. Simultaneous evaluation of matrix effects and absolute SPE recovery for $^{13}C_8$-PFOA in serum using different sample pre-treatments and SPE conditions allowed optimization of SPE process efficiency with minimal matrix effect and decent SPE recovery. Introduction of protein precipitation as a sample pre-treatment procedure for serum samples before SPE generally decreased matrix effect in LC-MS/MS analysis and provided more stable recovery of PFOA.