• Title/Summary/Keyword: Balance of Plant

Search Result 432, Processing Time 0.031 seconds

Influence of Reaction Temperature on the Pyrolytic Product of Rice Straw by Fast Pyrolysis using a Fluidized Bed (볏짚의 급속 열분해 생성물에 대한 반응온도의 영향)

  • Kang, Bo-Sung;Park, Young-Kwon;Kim, Joo-Sik
    • Proceedings of the Korean Institute of Resources Recycling Conference
    • /
    • 2005.10a
    • /
    • pp.47-58
    • /
    • 2005
  • Rice straw is one of the main renewable energy sources in Korea, and bio-oil is produced from rice straw with a lab. scale plant equipped mainly with a fluidized bed and a char removal system. We investigated how the reaction temperature affected the production of bio-oil and the efficiency of a char removal system. To elucidate how the temperature depended on the production of bio-oil, experiment were conducted between $450^{\circ}C\;and\;600^{\circ}C$ with a feed rate of about 300g/h. The mass balance was established in each experiment, and the produced gas and oil were analyzed with the aid of GCs and a GC-MS system. The char removal system is composed of a cyclone and a hot filter. In the experiments, we observed that the optimum reaction temperature range for the production of bio-oil is between $450^{\circ}C\;and\;500^{\circ}C$.

  • PDF

Study on the Characteristics of Low-pressure Automotive Polymer Electrolyte Membrane Fuel Cell System Efficiency with Blower Configuration (블로워 구성 변경에 따른 상압형 자동차용 고분자전해질형 연료전지 시스템의 효율 특성 연구)

  • KIM, IL-JOONG;LEE, JUNG-JAE;KIM, HAN-SANG
    • Journal of Hydrogen and New Energy
    • /
    • v.29 no.2
    • /
    • pp.181-189
    • /
    • 2018
  • Polymer electrolyte membrane fuel cell (PEMFC) system receives great attention as a promising power device for automotive applications. For the wide commercialization, the efficiency and performance of automotive PEMFC system should be further improved in terms of total system (stack and balance of plant [BOP]). Air supply module, which is a major part of the BOP, greatly affects the efficiency of automotive PEMFC system. In this paper, a systematic study on the low-pressure automotive PEMFC system was made in an attempt to enhance the net system efficiency. This study mainly presents an investigation of the effect of blower configuration (1-blower and 2-blower) on the net system efficiency of automotive PEMFC system. For this purpose, the effect of operating pressure and cathode stoichiometry on the system efficiency was investigated with stack temperature under the fixed net system power condition. Results indicate that 1-blower system is better in system efficiency over 2-blower system under an air stoichiometry of 2. However, 2-blower system is better in system efficiency under an air stoichiometry of 3. The simulation results show that the optimum operating strategy needs to be established for various blower system configurations considering blower performance maps.

Study on the Method of Estimating the Accumulation of Co-60 in Consideration of the Operating History of a NPP (원전 운전환경을 고려한 방사성폐기물 내 Co-60 재고량 평가 방안 연구)

  • Kim Tae-man;Whang Joo-ho
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.145-150
    • /
    • 2005
  • To dispose of radwaste in a repository, the safety of disposal must be ensured. This study developed a program for estimating radionuclide accumulation of radwaste, based on the material balance method, one of the indirect methods, and performed application evaluation during the 9th preventive maintenance period of Gori Plant 4, one of the commercial power plants in Korea. First of all, to ensure the technique developed in this study is assessed accurately, this study utilized the data regarding the radionuclide removal in the purification system during the shutdown water chemistry control, and a related estimation technique called SCALP. The target nuclide was Co-60, and it turned out that the relative error was less than $1\%$. The estimation result was compared with the result of direct measurement of the radwaste during the corresponding period as presented by commercial power plants. The result showed that the quantity of Co-60 measured by the direct method was about $50\%$ less than that calculated by the technique developed in this study.

  • PDF

Modeling of PEM Fuel Cell System-Sensitivity Analysis of System Efficiency with Different Main Operating Parameters of Automotive Fuel Cell System (PEM 연료전지 시스템 모델링-자동차용 연료전지 시스템의 주요 작동 변수 변경에 따른 시스템 효율 민감도 분석)

  • KIM, HAN-SANG;KANG, BYUNGGIL;WON, KWONSANG
    • Journal of Hydrogen and New Energy
    • /
    • v.30 no.5
    • /
    • pp.401-410
    • /
    • 2019
  • The operating conditions greatly impact the efficiency and performance of polymer electrolyte membrane (PEM) fuel cell systems and must be properly managed to ensure better performance and efficiency. In particular, small variations in operating conditions interact with each other and affect the performance and efficiency of PEM fuel cell systems. Thus, a systematic study is needed to understand how small changes in operating conditions affect the system performance and efficiency. In this paper, an automotive fuel cell system (including cell stack and balance of plant [BOP]) with a turbo-blower was modeled using MATLAB/Simulink platform and the sensitivity analyses of main operating parameters were performed using the developed system model. Effects of small variations in four main parameters (stack temperature, cathode air stoichiometry, cathode pressure, and cathode relative humidity) on the system efficiency were investigated. The results show that cathode pressure has the greatest potential impact on the sensitivity of fuel cell system efficiency. It is expected that this study can be used as a basic guidance to understand the importance of achieving accurate control of the fuel cell operating conditions for the robust operation of automotive PEM fuel cell systems.

The Study on the Comparison of the ISCST3 Model and Receptor Model by Dispersion Tracing of Particulate Matter from Large Scale Pollution Sources (대단위배출원에서 기인한 입자상오염물질의 확산ㆍ추적을 통한 ISCST3모델과 수용모델의 비교연구)

  • 전상기;이성철;박경선
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.6
    • /
    • pp.789-803
    • /
    • 2003
  • The purpose of this study is to compare the usefulness between Gaussian dispersion model and receptor model with the experimental result of the dispersion tracing of the particulate pollutants from Taean coal-fired power plants. For this purpose, the component analysis of the collected PM 10 samples was performed. In order to trace the pollution sources, factor analysis was done with the result of the component analysis. As a result of the correlativity analysis of the fifteen power plants' profiles offered by US EPA, the correlativity of No.11202 source profile showed highest rate up to 84.5%. Thus it was adopted as proper one and the contribution rate by each pollution source was calculated by Chemical Mass Balance (CMB)-8 model. The contribution rate, which was the effect rate of the power plants on each measuring point, were calculated with a range of 24∼52% and the standard error was below 0.9 $\mu\textrm{g}$/㎥. This indicates the selection of the source profile was appropriate. Also, the concentrations of each point were calculated by the ISCST3 which is suggested by US EPA as one of the regulatory Gaussian dispersion model. The calculation result showed that the predicted concentration was 50∼58 $\mu\textrm{g}$/㎥, comparing with the measured result of 9∼65 $\mu\textrm{g}$/㎥. It was found that the concentration calculated by ISCST3 was underpredicted. It was thought that the receptor model was more favorable than the Gaussian dispersion model in estimating the effect of the particulate matter on a certain receptive point.

Analysis of Performance and Energy Saving of a SOFC-Based Hybrid Desiccant Cooling System (건물용 연료전지 기반 하이브리드 제습냉방시스템 성능 및 에너지 절감 분석)

  • IN, JUNGHYUN;LEE, YULHO;KANG, SANGGYU;PARK, SUNGJIN
    • Journal of Hydrogen and New Energy
    • /
    • v.30 no.2
    • /
    • pp.136-146
    • /
    • 2019
  • A solid oxide fuel cell (SOFC) based hybrid desiccant cooling system model is developed to study the effect of fuel utilization rate of the SOFC on the reduction of energy consumption and $CO_2$ emission. The SOFC-based hybrid desiccant cooling system consists of an SOFC system and a Hybrid desiccant cooling system (HDCS). The SOFC system includes a stack and balance of plant (BOP), and HDCS. The HDCS consists of desiccant rotor, indirect evaporative cooler, electric heat pump (EHP), and heat exchangers. In this study, using energy load data of a commercial office building and SOFC-based HDCS model, the amount of ton of oil equivalent (TOE) and ton of $CO_2$ ($tCO_2$) are calculated and compared with the TOE and $tCO_2$ generation of the EHP using grid electricity.

Application of Free Water Surface Constructed Wetland for Treating the Agricultural Runoff (강우시 농업 비점오염원 처리를 위한 FWS 인공습지의 적용성 평가)

  • Kang, Chang-Guk;Lee, So-Young;Maniquiz, Marla C.;Kim, Lee-Hyung
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.1
    • /
    • pp.83-89
    • /
    • 2010
  • The areas for agricultural purposes in Korea are decreasing every year because of urbanization. However, it is still 17.6% of the total national boundary on 2008. Most of the rice paddy fields are located near the waterbodies which require lots of water during rainy season from May to September. Also lots of nitrate and phosphate chemical fertilizers are spread on the fields every year in order to supply the nutrients for vegetation. The excess nutrients is impairs the water quality of rivers and lakes when it is washed out from the fields. The Korean Ministry of Environment (MOE) adapted the new water quality improvement program, which is the Total Daily Maximum Load, to improve the water quality and to protect the aquaecosystems. The constructed wetland is one of the possible ways to treat the agricultural runoff. The constructed wetland on this study area was constructed by MOE in 2007 to evaluate the application of the constructed wetlands. Plant growth continues to increase during the summer until it reaches its highest biomass of 6,032 g/$m^2$ in August and September. More researches about sedimentation, vegetation, water balance, etc. were performed to evaluate the removal efficiency, to find the removal mechanisms and to make the guidelines for design and maintenance.

Spatial Abundance and Diversity of Bacterioplankton in a Typical Stream-Forming Ecosystem, Huangqian Reservoir, China

  • Wei, Guangshan;Li, Jing;Wang, Ningxin;Gao, Zheng
    • Journal of Microbiology and Biotechnology
    • /
    • v.24 no.10
    • /
    • pp.1308-1318
    • /
    • 2014
  • The specific freshwater environment of reservoirs formed by streams has not been well studied. In this paper, the bacterioplankton community in such a reservoir, the Huangqian Reservoir in eastern China, was described using culture-independent molecular methods. We found that the most dominant bacterioplankton were affiliated with Cyanobacteria, followed by Betaproteobacteria, Bacteroidetes, Gammaproteobacteria, and Actinobacteria. Both bacterial abundance and diversity increased along the direction of water flow, and the 16S rRNA gene copy number in the water outlet was nearly an order of magnitude higher than that in the water inlet. Pearson correlation analyses indicated that nitrate had a significantly negative correlation with the bacterial abundance (p < 0.05) and that ammonium was positively correlated with bacterial abundance (p < 0.05). Interestingly, owing to a remarkably negative correlation (p < 0.01), the ratio of nitrate and ammonium might serve as a good pre dictor of the relative abundance of bacterioplankton. According to redundancy analysis, nitrate and dissolved oxygen were the major factors influencing the bacterial communities. In addition, we attempted to determine the reasons why such a reservoir could maintain good ecological balance for a period of decades, and we found that the environmental factors and bacterial communities both played critical roles. This research will benefit our understanding of bacterial communities and their surrounding environments in freshwater ecosystems.

Multi-FNN Identification Based on HCM Clustering and Evolutionary Fuzzy Granulation

  • Park, Ho-Sung;Oh, Sung-Kwun
    • International Journal of Control, Automation, and Systems
    • /
    • v.1 no.2
    • /
    • pp.194-202
    • /
    • 2003
  • In this paper, we introduce a category of Multi-FNN (Fuzzy-Neural Networks) models, analyze the underlying architectures and propose a comprehensive identification framework. The proposed Multi-FNNs dwell on a concept of fuzzy rule-based FNNs based on HCM clustering and evolutionary fuzzy granulation, and exploit linear inference being treated as a generic inference mechanism. By this nature, this FNN model is geared toward capturing relationships between information granules known as fuzzy sets. The form of the information granules themselves (in particular their distribution and a type of membership function) becomes an important design feature of the FNN model contributing to its structural as well as parametric optimization. The identification environment uses clustering techniques (Hard C - Means, HCM) and exploits genetic optimization as a vehicle of global optimization. The global optimization is augmented by more refined gradient-based learning mechanisms such as standard back-propagation. The HCM algorithm, whose role is to carry out preprocessing of the process data for system modeling, is utilized to determine the structure of Multi-FNNs. The detailed parameters of the Multi-FNN (such as apexes of membership functions, learning rates and momentum coefficients) are adjusted using genetic algorithms. An aggregate performance index with a weighting factor is proposed in order to achieve a sound balance between approximation and generalization (predictive) abilities of the model. To evaluate the performance of the proposed model, two numeric data sets are experimented with. One is the numerical data coming from a description of a certain nonlinear function and the other is NOx emission process data from a gas turbine power plant.

The Effect of Thermal Management on the Performance of a Polymer Electrolyte Membrane Fuel Cell System (PEMFC의 열관리가 시스템의 성능에 미치는 영향)

  • Lee, Jeong-Ho;Myung, No-Sung;Kim, Tong-Seop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.6
    • /
    • pp.593-601
    • /
    • 2011
  • An analysis program to simulate the operation of a polymer electrolyte membrane fuel cell (PEMFC) system was set up, and system operation with variations in the working conditions of various components (especially the thermal management system) was simulated. The entire system included a PEMFC stack and balance-of-plant components such as an air-supply unit, a fuel-supply unit, and a heat-management unit (cooling system). Thermodynamic models of all components were made to evaluate the design performance of the entire system, and then off-design models were set up to simulate the operation of the entire system under arbitrary working conditions. A parametric study was carried out to examine the effects of varying the operating conditions (especially the ambient conditions and the operating conditions of the cooling system) on the operation and performance of the entire system.