Power Allocation Method for Multiple ESS Control Considering SOC Balancing in Microgrids (마이크로그리드에서 SOC균형을 고려한 ESS의 충·방전 전력배분 방법)

  • Lee, Sang-Wook;Park, Juneho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.2
    • /
    • pp.292-299
    • /
    • 2017
  • In this paper, multiple ESS(Energy Storage System) control strategy for microgrids is presented. Installation of ESS becomes mandatory when microgrids are used to supply high quality power to the loads. The one of main functions of the ESS is to maintain power balance. However ESS has limitation of its capacity and instantaneous injecting power. Power allocation method based on SOC(State Of Charge) of each ESS is proposed. P-Q control is employed as the basic control strategy for the distributed ESSs. By using the proposed method, the coefficients in the conventional P-Q control method are modified. The ESSs with higher SOC inject more active power, while those with lower SOC inject less, leading to more balanced SOC levels among the ESSs. The proposed method is demonstrated by simulation using PSCAD/EMTDC.

Evaluation of Power Flow Control Strategy and DC-link Voltage Regulation for DC Microgrid

  • Nguyen, Thanh Van;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.416-417
    • /
    • 2019
  • In this paper, an effective power flow control strategy (PFCS) based on the centralized control approach and a DC-link (DCV) restoration algorithm for DC microgrid (DCMG) are presented. By investigating the statuses of system power units, eleven operating modes are given to ensure the system power balance under various conditions. To avoid the system power imbalance caused by the delay of grid fault detection, a reliable DCV restoration algorithm is proposed. In the proposed scheme, when an abnormal variation of the DCV is detected, the battery instantly starts a local emergency control mode to restore the DCV to the nominal value regardless of the control mode from the central controller. The simulations and experiments are carried out to prove the effectiveness of the PFCS and the proposed DCV restoration algorithm.

  • PDF

A Master and Slave Control Strategy for Parallel Operation of Three-Phase UPS Systems with Different Ratings (다른 정격용량을 가진 3상 UPS 시스템의 병렬운전을 위한 주종제어 기법)

  • 이우철;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.341-349
    • /
    • 2004
  • A parallel operation of Uninterruptible Power Supply(UPS) systems is used to increase power capacity of the system or to secure higher reliability at critical loads. In the conventional parallel operation, the load-sharing control to maintain the current balance is the most important, since the load-sharing is very sensitive to discord between components of each module, amplitude/phase difference, line impedance, output LC filter, and so on. To solve these problems various control algorithms are researching. However, these methods cannot apply to the different ratings of UPS. In the case, master and slave control algorithm for parallel operation is adequate. However, if the UPS ratings are different, the value of passive filters L, C is different, and it affects the sharing of current. This paper presents general problems of conventional parallel operation systems, and control strategy for parallel operation with different ratings. The validity of the proposed control strategy is investigated through simulation and experiment in the parallel operation system with two 3-phase UPS systems.

Constant DC Capacitor Voltage Control based Strategy for Active Load Balancer in Three-phase Four-wire Distribution Systems

  • Win, Tint Soe;Tanaka, Toshihiko;Hiraki, Eiji;Okamoto, Masayuki;Lee, Seong Ryong
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.2
    • /
    • pp.176-183
    • /
    • 2014
  • Three-phase four-wire distribution systems are used for both three-phase three-wire loads and single-phase two-wire consumer appliances in South Korea, Myanmar and other countries. Unbalanced load conditions frequently occur in these distribution systems. These unbalanced load conditions cause unbalanced voltages for three-phase and single-phase loads, and increase the loss in the distribution transformer. In this paper, we propose constant DC capacitor voltage control based strategy for the active load balancer (ALB) in the three-phase four-wire distribution systems. Constant DC capacitor voltage control is always used in active power line conditioners. The proposed control strategy does not require any computation blocks of the active and reactive currents on the distribution systems. Balanced source-side currents with a unity power factor are obtained without any calculation block of the unbalanced active and reactive components on the load side. The basic principle of the constant DC capacitor voltage control based strategy for the ALB is discussed in detail and then confirmed by both digital computer simulations using PSIM software and prototype experimental model. Simulation and experimental results demonstrate that the proposed control strategy for the ALB can balance the source currents with a unity power factor in the three-phase four-wire distribution systems.

Study on the Characteristic of Dynamic Postural Control during Horizontal Translation of Support Surface (지지면의 수평 진동에 따른 동적 자세 제어 특성에 관한 연구)

  • Oh, G.Y.;Piao, Y.J.;Kwon, T.K.;Kim, N.G.
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.6
    • /
    • pp.495-502
    • /
    • 2009
  • This paper investigated the effects of dynamic postural control for maintaining upright standing on a support surface during continuous sinusoidal horizontal translation in anterior-posterior direction. 15 healthy young subjects participated in this experiment. The analysis of body movement was analyzed using Ariel Performance Analysis System. Motion pattern was analyzed by seven markers on subject's body. Position of markers were head, chest, hip, right knee, left knee, right ankle and left ankle. Seven different frequencies of support surface were employed ; 0.1, 0.25, 0.5, 0.75, 1, 1.5 and 2Hz at 2cm of moving path of motionbase. The experiments were performed dynamic postural reponses at the condition of eye open. The results showed that median frequency of the knee, ankle were increased in all frequency bands. Following the frequency of perturbation increased, postural control strategy was changed from ankle strategy to combined strategy. The experiment results could be applied to the dynamic postural training for the elderly and the rehabilitation training for the patients to improving the ability of postural control.

The Effect of Backward Walking Training in the Walking Speed and Balance Capability of Patients with Hemiplegia (편마비 환자에 대한 후방보행 훈련이 보행 속도와 균형 능력에 미치는 영향)

  • Ki, Kyong-Il;Kim, Suhn-Yeop;Oh, Duk-Wyon;Kim, Kyung-Hwan
    • Journal of Korean Physical Therapy Science
    • /
    • v.16 no.2
    • /
    • pp.1-9
    • /
    • 2009
  • Background: The ability for backward walking is considered to be necessary for the neuromuscular control and maintenance of balance in daily ambulatory activity. This study aimed to determine the effect of backward walking training on the walking speed and balance control in patients with hemiplegia. Methods: Fourteen patients with hemiplegia were randomly allocated to an experimental and control groups of seven patients each. For the experimental group, we performed both conventional training and backward walking training, and conventional training only for the control group. The conventional training programs for the 2 groups were conducted for 30 min, twice a day, 5 times a week for 4 weeks, and backward walking training for the experimental group was conducted for 30 min, 3 times a week. The outcomes were assessed using the functional reach test (FRT), timed up-and-go (TUG) Test, and the 10 meter walk time test (10mWT). Result: A comparison of the FRT, TUG test, and 10mWT scores obtained before and after the 4-week treatment revealed statistically significant differences (p<.05) for the experimental group; however, there was no such difference in the case of the control group (p>.05). On assessment after the 4-week treatment, statistically significant differences were noted in the TUG test and 10mWT scores of the experimental group (p<.05). Conclusion: Our findings suggest that backward walking training is an effective clinical strategy for improving the walking speed and functional mobility of patients with hemiplegia.

  • PDF

A Novel Hybrid Intelligence Algorithm for Solving Combinatorial Optimization Problems

  • Deng, Wu;Chen, Han;Li, He
    • Journal of Computing Science and Engineering
    • /
    • v.8 no.4
    • /
    • pp.199-206
    • /
    • 2014
  • The ant colony optimization (ACO) algorithm is a new heuristic algorithm that offers good robustness and searching ability. With in-depth exploration, the ACO algorithm exhibits slow convergence speed, and yields local optimization solutions. Based on analysis of the ACO algorithm and the genetic algorithm, we propose a novel hybrid genetic ant colony optimization (NHGAO) algorithm that integrates multi-population strategy, collaborative strategy, genetic strategy, and ant colony strategy, to avoid the premature phenomenon, dynamically balance the global search ability and local search ability, and accelerate the convergence speed. We select the traveling salesman problem to demonstrate the validity and feasibility of the NHGAO algorithm for solving complex optimization problems. The simulation experiment results show that the proposed NHGAO algorithm can obtain the global optimal solution, achieve self-adaptive control parameters, and avoid the phenomena of stagnation and prematurity.

Research of the adaptive control on modulation factor for PSR fly-back PSM converter

  • Tian, Lei;Li, Qinqin;Wang, Weiheng
    • ETRI Journal
    • /
    • v.41 no.1
    • /
    • pp.124-132
    • /
    • 2019
  • The energy balance (EB) model of a primary side regulation (PSR) fly-back converter in the discontinuous conduction mode (DCM) is discussed in this paper. Based on this EB model, the stability of a PSR fly-back converter in the pulse skipping mode (PSM) is analyzed, and a self-adapting modulation factor control strategy is proposed. Theoretical analysis and simulation results show that by saving an optocoupler and correlative circuits, which are necessary in traditional PSM fly-back converters, the modulation factor tolerance controlled by this method is 1.26% on average, corresponding to the ideal value. Compared with traditional fly-back PSM controllers, the power saved in the sampler/comparator modules is 87% on average for a load range of $1{\Omega}$ to $1k{\Omega}$.

The Effects of Home Based Exercise Program on Balance Recovery in a Post-Stroke Population (뇌졸중 환자의 균형능력 회복을 위한 가정운동프로그램 효과)

  • Jang, Sang-Hun;Bang, Hyun-Soo;Jung, Byeong-Ok
    • Journal of Digital Convergence
    • /
    • v.12 no.7
    • /
    • pp.297-304
    • /
    • 2014
  • The present study was designed to investigate the effect of home based exercise program on balance recovery of stroke patients. In total, 20 participants were assigned to a control group(n=10) or exercise group(n=10) between September 2013 and December 2013. In addition to existing physiotherapy, the exercise group received home based exercise program consisting of weight transfer, training endurance, mobility, sensory retraining, lower limb exercise for 30 minutes, 2 times a week, for 8 weeks, every time for 30 minutes. Balance ability was assessed by measuring foot pressure(FP), limit of stability(LOS) and velocity sway(VS) by using Biorescue and by using the functional reaching test(FRT). To compare the improvement level of each group's balance ability, examination of independent sample T was done. Significant differences between control group and exercise group in LOS, VS of affect side and FRT were observed. This study showed that home based exercise program application was effective strategy on balance recovery in a post stroke population.

The Effects of Stair Climbing Training with Functional Electrical Stimulation on Muscle Strength, Balance, and Gait in Patients with Chronic Stroke

  • Koh, Sieun;Choi, Wonjae;Lee, Seungwon
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.1
    • /
    • pp.32-39
    • /
    • 2021
  • Objective: The weakness of muscle strength due to stroke affects the posture control and gait in the patients with stroke. Stroke This study examined the effects of the stair climbing training with functional electrical stimulation on muscle strength, dynamic balance, and gait in individuals with chronic stroke. Design: Randomized controlled trial. Methods: Total forty-eight patients were randomly assigned to the 3 groups. Participants randomly divided to stair climbing training with functional electrical stimulation group (SCT+FES group, n=16), stair climbing training group (SCT group, n=16) and control group (n=16). Subjects in the SCT+FES group and SCT group performed stair walking training with and without functional electrical stimulation for 30 minutes, 3 sessions per week for 4 weeks and all subjects received conventional physical therapy for 30 minutes with 5 sessions per week for 4 weeks. Outcome measurements were assessed using the sit-to stand Test for strength, timed up and go test and modified-timed up and go test for dynamic balance, and 10m walk test and GaitRite system for gait. Results: In the SCT+FES group, subjects have been shown the significant increase in lower extremity strength (p<0.05), significantly improve in dynamic balance (p<0.05), and significantly improve in their temporal gait parameter (p<0.05). The SCT+FES group was significantly better than other groups in all parameters (p<0.05). Conclusions: This result suggested that the SCT+FES may be effective strategy to improve muscle strength, dynamic balance, and gait for individuals with chronic stroke.