• 제목/요약/키워드: Background counts

검색결과 210건 처리시간 0.019초

Monotonic and Parallelizable Algorithm for Simultaneous Reconstruction of Activity/Attenuation using Emission data in PET

  • Kim, Seung-Gu
    • Communications for Statistical Applications and Methods
    • /
    • 제8권1호
    • /
    • pp.299-309
    • /
    • 2001
  • In PET(Positron Emission Tomography), it is necessary to use transmission scan data in order to estimate the attenuation map. Recently, there are several empirical studies in which one might be able to estimate attenuation map and activity distribution simultaneously with emissive sinogram alone without transmission scan. However, their algorithms are based on the model in which does not include the background counts term, and so is unrealistic. If the background counts component has been included in the model, their algorithm would introduce non-monotonic reconstruction algorithm which results in vain in practice. in this paper, we develop a monotonic and parallelizable algorithm for simultaneous reconstruction of both characteristics and present the validity through some simulations.

  • PDF

Quantitative Analysis of Distribution of the Gastrointestinal Tract Eosinophils in Childhood Functional Abdominal Pain Disorders

  • Lee, Eun Hye;Yang, Hye Ran;Lee, Hye Seung
    • Journal of Neurogastroenterology and Motility
    • /
    • 제24권4호
    • /
    • pp.614-627
    • /
    • 2018
  • Background/Aims Although functional abdominal pain disorders (FAPDs) are common in children, the accurate pathogenesis of FAPDs is not known yet. Micro-inflammation, particularly tissue eosinophilia of gastrointestinal (GI) tract, has been suggested as the pathophysiology observed in several GI disorders. We aimed to evaluate eosinophilic infiltration throughout the entire GI tract in children with FAPDs, compared to those with inflammatory bowel diseases (IBD) and to normal reference values. Methods We included 56 children with FAPDs, 52 children with Crohn's disease, and 23 children with ulcerative colitis. All subjects underwent esophagogastroduodenoscopic and colonoscopic examination with biopsies. Tissue eosinophil counts were assessed in 10 regions throughout the GI tract. Results Eosinophil counts of the gastric antrum, duodenum, terminal ileum, cecum, and ascending colon were significantly higher in children with FAPDs compared to normal reference values. Eosinophil counts of the stomach and the entire colon were observed to be significantly higher in children with IBD than in those with FAPDs. Even after selecting macroscopically uninvolved GI segments on endoscopy in children with IBD, eosinophil counts of the gastric body, cecum, descending colon, sigmoid colon, and the rectum were also significantly higher in children with IBD than those with FAPDs. Conclusions Significantly high eosinophil counts of the stomach and colon were observed in the order of IBD, followed by FAPDs, and normal controls, regardless of endoscopically detected macroscopic IBD lesions in children. This suggests some contribution of GI tract eosinophils in the intrinsic pathogenesis of FAPDs in children.

백그라운드 제거후 신호의 세기에 대하여 (ON THE BACKGROUND-SUBTRACTED INTENSITY)

  • 선광일
    • 천문학논총
    • /
    • 제20권1호
    • /
    • pp.109-116
    • /
    • 2005
  • When we measure a source signal in the presence of a background rate that has been independently measured, the usual approach is to obtain an estimate of the background rate by observing an empty part of the sky, and an estimate of the source signal plus background rate by observing the region where a source signal is expected. The source signal rate is then estimated by subtracting the background rate from the source signal plus background rate. However, when the rates or their observation times are small, this procedure can lead to negative estimates of the source signal rate, even when it should produce a positive value. By applying the Bayesian approach, we solve the problem and prove that the most probable value of source signal rate is zero when the observed total count is smaller than the expected background counts. It is also shown that the results from the conventional method is consistent with the most probable value obtained from the Bayesian approach when the source signal is large or the observation time is long enough.

침(鍼) 및 전침(電鍼)이 SHR 대뇌(大腦)에서 Doublecortin, PSA-NCAM, pCREB 양성 신경세포에 미치는 영향 (Effects of Acupuncture and Electroacupuncture on the Doublecortin, PSA-NCAM and pCREB Expression in the Brain of Spontaneously Hypertensive Rats)

  • 박정환;이재동;김창환
    • Journal of Acupuncture Research
    • /
    • 제21권3호
    • /
    • pp.61-81
    • /
    • 2004
  • Background and Objective : The aim of this study was to investigate the effects of acupuncture and electroacupuncture on the DCX, PSA-NCAM, and pCREB expression in the brain of spontaneously hypertensive rats(SHR). Materials and Methods : SHR were divided into five groups: control group, acupuncture group, 2Hz electroacupuncture(EA) group and 100Hz EA group. We evaluated the changes of the DCX, PSA-NCAM, and pCREB positive cells using immunohistochemical method. In the olfactory bulb, we investigate the optical densities of the immunoactive cells. In the dentate gyrus and the piriform cortex, we count the immunoactive cells under the $100{\times}$ visual field optical microscope. Results : 1. The optical densities of DCX-positive cells in the subependymal zone were significantly decreased in all groups, compared to the control group. 2. The counts of DCX-positive cells in the dentate gyrus were significantly increased in all groups, compared to the control group. The counts of DCX-positive cells in the piriform cortex were significantly increased in the acupuncture and 100Hz EA group, compared to the control group. 3. The optical densities of PSA-NCAM-positive cells in the subependymal zone were significantly decreased in the acupuncture and 2Hz EA group, compared to the control group. 4. The counts of PSA-NCAM-positive cells in the dentate gyrus and the piriform cortex were significantly increased in all group, compared to the control group. 5. The counts of pCREB-positive cells in the dentate gyrus were significantly increased in all groups, compared to the control group. The counts of pCREB-positive cells in the piriform cortex were significantly increased in the acupuncture and 100Hz EA group, compared to the control group. Conclusion : We conclude that acupuncture and EA may affect neuronal cell proliferation, differentiation and plasticity in the brain.

  • PDF

Brain Perfusion SPECT에서 Image Registration의 유용성 (Usefulness of Image Registration in Brain Perfusion SPECT)

  • 송호준;임정진;김진의;김현주
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.60-64
    • /
    • 2011
  • Brain의 질병을 평가하는 유용한 검사방법 중의 하나인 brain perfusion SPECT는 환자의 움직임으로 인한 검사의 실패확률이 높아 one day method를 사용하지 못하고 two days method를 사용해야 하는 경우가 많다. 본 연구에서는 image registration을 사용하여 검사의 실패확률을 줄이고 one day method로 검사를 시행할 수 있는지 image registration을 적용할 경우 검사의 신뢰성을 알아보고자 하였다. Jaszczak phantom에 준비된 방사성동위원소 $^{99m}Tc$을 insert에 111 MBq/mL가 되도록 분배하여 넣고 나머지 background에 3,145 MBq/mL가 되도록 넣어 1:8의 비율로 phantom을 제작하고 Hoffman 2-D brain phantom과 cylindrical uniform phantom에는 111 MBq/mL가 되도록 만든다. 완성된 phantom은 기본 위치에서 frame 당 5 sec씩 총 120 frame을 획득하여 영상을 얻었다. 또 Phantom과 환자의 데이터를 가지고 original 영상과 registration 영상, registration 시행한 후에 original 영상을 subtraction한 영상과 registration하지 않은 영상에서 subtraction한 영상 간의 임의의 같은 위치에 ROI를 설정하고 영상에서 counts 차이를 알아보았다. 실험 결과 약간의 counts 차이를 보였으나 이것은 실험시간이 경과함에 따른 RI의 decay와 phantom의 구조물이 없는 cylindlical phantom에서 조차 약간의 counts의 차이를 보이는 바로 미루어 봤을 때 실험 결과 나온 counts의 차이는 적다고 할 수 있을 것이다. 따라서 registration을 활용하여 brain perfusion SPECT의 단점들을 개선하고 정확한 진단에 도움을 줄 수 있을 것으로 사료된다.

  • PDF

Attenuation of Background Molecular Ions and Determination of Isotope Ratios by Inductively Coupled Plasma Mass Spectrometry at Cool Plasma Condition

  • 박창준
    • Bulletin of the Korean Chemical Society
    • /
    • 제18권7호
    • /
    • pp.706-710
    • /
    • 1997
  • Isotope ratios of K, Ca, Cr and Fe are measured at cool plasma condition generated using high carrier flow rate and relatively low RF power of 900 W. Background molecular ions are suppressed to below 100 counts which give isobaric interference to the analytes. The background ions show different attenuation characteristics at increased carrier flow rate and hence for each element different carrier flow rate should be used to measure isotope ratios without isobaric interference. Isotope ratios are measured at both scan and peak-hopping modes and compared with certified or accepted ratios. The measured isotope ratios show some mass discrimination against low mass due to low ion energy induced from a copper shield to eliminate capacitive coupling of plasma with load coil.

환경방사능의 감마선 분광분석을 위한 백그라운드 소멸 (Background Reduction for the ${\gamma}$-Ray Spectrometry of Environmental Radioactivity)

  • 서범경;이길용;윤윤열;이대원
    • 분석과학
    • /
    • 제14권3호
    • /
    • pp.212-220
    • /
    • 2001
  • 본 연구는 감마선 분광분석법을 이용하여 환경시료에 함유되어 있는 천연방사성 핵종인 라듐($^{226}Ra$) 및 라돈($^{222}Rn$)의 직접분석법의 개발을 목표로 수행되었다. 감마선 분광분석법에 의한 라듐 및 라돈의 분석에서는 주변환경조건에 따라서 변화의 폭이 큰 대기중의 라돈 및 딸핵종에 의한 백그라운드 영향을 소멸시키거나 보정해 주어야만 한다. 본 고에서는 측정함 내부로 질소가스를 흘려주어 측정함 내부를 질소가스 분위기로 바꾸어 줌으로서 대기중의 라돈 및 딸핵종에 의한 불안정한 백그라운드를 소멸시키고자 하였다. 질소가스를 검출기 주위로 흘려주었을 때, 1 MeV 이하의 에너지 영역에 대해서는 80% 그리고 1 MeV 이상에서는 20~50% 정도까지 백그라운드를 감소시킬 수 있었다. 즉, 검출기 주위를 질소분위기로 바꾸어 줌으로서 백그라운드를 소멸, 안정화시킴으로서 검출감도를 약 10배 향상시킬 수 있었다.

  • PDF

List Mode에서 PET/CT Scanner의 직선성 평가 (Linearity Estimation of PET/CT Scanner in List Mode Acquisition)

  • 최현준;김병진;이또 미키코;이홍재;김진의;김현주;이재성;이동수
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.86-90
    • /
    • 2012
  • Rb-82를 이용한 PET 검사는 심근 관류의 임상적 평가에 중요한 역할을 한다고 알려져 있다. 그러나 PET/CT의 dead time 때문에 count value와 방사능농도 사이의 직선성이 유지되지 않는다면 데이터를 획득할 때 좌심실 입력 함수가 과대평가되어 심근관류가 과대평가될 수 있다. 본 연구에서는 리스트 모드에서 획득한 PET data에서 방사능농도에 따른 count value의 직선성을 평가하였다. Biograph 40 True Point PET/CT를 이용하여 직경 12 cm, 길이 10.5 cm의 cylindrical phantom에 F-18 333 MBq과 물 800 mL를 채우고 7반감기동안 10min frame/bed로 리스트 모드를 이용하여 획득하였다. Raw data는 OSEM (order: 4, subsets: 8)과 FBP (Gaussian filter FWHM 5 mm) 알고리즘을 이용하여 재구성하였다. Sinogram 정보에서 prompt counts, net true counts, random counts를 측정하였다. 재구성 된 phantom 영상에 ROI를 설정하여 총 계수와 background를 측정하고 background correction을 사용하여 count value를 측정하여 직선성을 평가하였다. 리스트 모드를 이용하여 sinogram에서 측정된 prompt counts는 방사능농도에 비례하여 증가하였다. 낮은 방사능농도에서 net true counts와 random counts는 방사능농도에 따라 증가하였다. 높은 방사능농도에서는 net true counts의 증가율이 점차 감소되었고, 반면에 random counts의 증가율은 증가하였다. 그리고 OSEM과 FBP 알고리즘으로 재구성된 영상에서 측정한 count value의 차이는 없었고 방사능농도에 비례하여 count value가 증가하고 직선성이 유지되었다. Biograph 40 True Point PET/CT scanner는 재구성된 영상에서 낮은 방사능농도뿐만 아니라 높은 방사능농도(~416.25 kBq/mL)에서도 측정 된 count value와 방사능농도 사이의 직선성이 유지되는 것을 보여주었다. 따라서 실험에서 사용한 PET/CT scanner는 Rb-82, N-13, O-15, F-18을 이용한 heart dynamic PET study에서데이터의 정량적 분석에 유용할 것으로 판단된다.

  • PDF