• Title/Summary/Keyword: Back-Gauge

Search Result 55, Processing Time 0.022 seconds

A Study on Effective Management Method of the Flood Forecast System using PDA (PDA를 활용한 홍수예보시스템의 효율적 관리방안에 대한 연구)

  • Jung, Seung-Back;Yang, Seung-In
    • The KIPS Transactions:PartA
    • /
    • v.17A no.4
    • /
    • pp.197-202
    • /
    • 2010
  • The recorder at observatory can save the measured data from water gauge and rain gauge at an interval of five minutes. And then, the RTU (Remote Terminal Unit) in observatory sends the measured data in the recorder to the TM (Telemetering) in FCO (Flood Control Office) at an interval of ten minutes using VHF or satellite communication. But the transmitted data is not the stored data at the recorder, it is just data that is measured at an interval of ten minutes. In the FCO, the transmitted data is analyzed in order to forecast the flood. And also one of the most important things is the maintenance of an observatory. In this paper, an effective management system for the flood forecast is proposed. It uses the CDMA and the Blutooth technology on PDA. The proposed system is very portable, and also easily able to send the data stored at the recorder in observatory to TM in FCO without RTU. And it allows us to view remotely the data of other observatories by downloading from the FCO. Hence the system can do efficiently the maintenance of observatory without wasting manpower and time.

The clinical effects of Low Back Pain and Sciatica with Traction treatment (견인요법(牽引療法)을 병용한 요통(腰痛) 및 요각통(腰脚痛) 환자 40례(例)의 임상적 고찰)

  • Lee, Dong-hyun;Park, Eun-ju;Shin, Jung-chul;Na, Gun-ho;Wei, Tung-shuen;Lee, Sam-ro;Lyu, Chung-yeol;Cho, Myung-rae;Chae, Wu-suk;Yoon, Yeo-choong
    • Journal of Acupuncture Research
    • /
    • v.21 no.5
    • /
    • pp.163-177
    • /
    • 2004
  • Objectives : The purpose of this report is to use more Traction treatment clinically by comparing th Improvement of Low Back Pain and Sciatica between Common treatment Group and Common treatment with Traction treatment. Methods : This study was carried out on 40 patients with Low Back Pain and Sciatica who were hospitalized in Dongshin Univ. Oriental Hospital from January, 2003 to May, 2004. Group A of 20 patients were taken both common treatment and Traction treatment. And Group B of 20 patients were only taken common treatment. And at discharge day, we checked and compared VAS(Visual Analogue Scale) and ODI(Oswestry disability index) out of these two groups. SPSS(Statistical Program for Social Science) for Window was used for a statistical analysis and the independent T-test was performed to gauge the improvement of VAS(Visual Analogue Scale) and ODI(Oswestry disability index) out of these two groups, in which case, value of P below 0.05 is considered as useful. Results : The result of the VAS(Visual Analogue Scale) and ODI(Oswestry disability index) of comparison analysis between two groups at discharge day, shows that the improvement of Low Back Pain and Sciatica in cmmon treatment with Traction treatment Group is more effective than that in Common treatment.

  • PDF

Comparision of the Improvement of Back pain and Sciatica between Common Acupuncture treatment Group and Common Acupuncture with Shin Jong Gyuk of Ohaeng Acupuncture treatment Group (요통(腰痛) 및 요각통(腰脚痛) 환자(患者)의 체침요법(體鍼療法)과 오행침법(五行鍼法)의 현정격병용(賢正格倂用)에 의한 증상호전 비교)

  • Kim, Jae-Hong;Park, Eun-Ju;Park, Chun-Ha;Cho, Myung-Rae;Ryu, Chung-Ryul;Chae, Woo-Suk
    • Journal of Acupuncture Research
    • /
    • v.19 no.1
    • /
    • pp.84-91
    • /
    • 2002
  • Objective : The purpose of this report is to use more Shin Jong Gyuk of Ohaeng Acupuncture acupunture treatment clinically by comparing the Improvement of Back pain and Sciatica between Common Acupuncture treatment Group and Common Acupuncture with Shin Jong Gyuk of Ohaeng Acupuncture treatment Group. Methods : This study was carried out on 40 patients with Back pain and Sciatica who were hospitalized in Dongshin Univ. Oriental Hospital from 1st, April, 2001 to Tenth, November, 2001. Group A of 20 patients were taken both common acupunture treatment and Shin Jong Gyuk of Ohaeng Acupuncture treatment. And Group B of 20 patients were only taken common acupunture treatment. And after 10 days of admission, we checked and compared VAS(Visual Analogue Scale) and improvement index out of these two groups. SPSS(Statistical Program for Sdcial Science) for Window was used for a statistical analysis and the independent T-test was performed to gauge the improvement of VAS(Visual Analogue Scale) and improvement index out of these two groups, in which case, value of P below 0.05 is considered as useful. Results : The result of the VAS(Visual Analogue Scale) and improvement index of comparision analysis between two groups after 10 days, shows that the improvement of Back pain and Sciatica in Common Acupuncture treatment with Shin Tong Gyuk of Ohaeng Acupuncture treatment Group is more effective than that in Common Acupuncture treatment Group. (independent T-test improvement index P=0.21, VAS P=0.00)

  • PDF

Results of Intradiscal Pulsed Radiofrequency for Lumbar Discogenic Pain: Comparison with Intradiscal Electrothermal Therapy

  • Fukui, Sei;Nitta, Kazuhito;Iwashita, Narihito;Tomie, Hisashi;Nosaka, Shuichi;Rohof, Olav
    • The Korean Journal of Pain
    • /
    • v.25 no.3
    • /
    • pp.155-160
    • /
    • 2012
  • Background: We have developed an intradiscal pulsed radiofrequency (Disc PRF) technique, using Diskit $II^{(R)}$ needles (NeuroTherm, Wilmington, MA, USA), as a minimally invasive treatment option for chronic discogenic low back pain (LBP). The purpose of this study was to compare the representative outcomes of Disc PRF and Intradiscal Electrothermal Therapy (IDET) in terms of pain relief and reduction of disability. Methods: Thirty-one patients with chronic discogenic LBP who underwent either Disc PRF (n = 15) or IDET (n = 16) were enrolled in the study. A Diskit $II^{(R)}$ needle (15-cm length, 20-gauge needle with a 20-mm active tip) was placed centrally in the disc. PRF was applied for 15 min at a setting of $5{\times}50$ ms/s and 60 V. The pain intensity score on a 0-10 numeric rating scale (NRS) and the Roland-Morris Disability Questionnaire (RMDQ) were assessed pretreatment and at 1, 3, and 6 months post-treatment. Results: The mean NRS was significantly improved from $7.2{\pm}0.6$ pretreatment to$2.5{\pm}0.9$ in the Disc PRF group, and from $7.5{\pm}1.0$ to $1.7{\pm}1.5$ in the IDET group, at the 6-month follow-up. The mean RMDQ also showed significant improvement in both the Disc PRF group and the IDET group at the 6-month follow-up. There were no significant differences in the pretreatment NRS and RMDQ scores between the groups. Conclusions: Disc PRF appears to be an alternative to IDET as a safe, minimally invasive treatment option for patients with chronic discogenic LBP.

Hand Evaluation and Favorable Image of Knit Fabrics -A Focus on Intarsia and Color Jacquard- (니트 소재의 질감 평가와 호감도 -인타샤와 칼라자카드를 중심으로-)

  • Lim, Gee-Jung;Lee, Mee-Sik
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.8
    • /
    • pp.828-836
    • /
    • 2012
  • This study provided the data for the planning of knit apparel by analyzing structural effects of intarsia and jacquard knit on mechanical properties, subjective hand measurements, and preference. Intarsia and 7 types of color jacquard (floating jacquard, normal jacquard, bird's eye jacquard, tubular jacquard, ladder's back jacquard, blister jacquard, and transfer jacquard) were used. The samples (with a gauge of 14) were knitted using 100% wool 2/48's yarn by a Shima Seiki SIG computer knitting machine. Mechanical properties and hand values were measured by a KES-FB system. Subjective hand and favorable images were surveyed based on women in their 20s and 30s. The data were analyzed by a factor analysis, ANOVA and correlation analysis using SPSS 12.0. The subjective hand of intarsia and jacquard knits was categorized into 'thermofeeling', 'weight/flexibility', and 'durability'. The results of the favorable image survey for F/W outer knitwear showed that tubular jacquard was most favorable; however, the transfer jacquard was least favorable. Among the three factors that explain the subjective hand, thermofeeling had a strong influence on the favorable image of consumers. Bird's eye jacquard and tubular jacquard turned out to be most suitable for suits, intarsia and floating jacquard were suitable for cardigans and sweaters, ladder's back jacquard was suitable for hats or mufflers, and transfer jacquard was suitable for home fashion rather than garments.

A Study on Fatigue Crack Growth Characterization Of Surface Crack In Pressure Vessel Materials (압력용기 소재에서의 표면균열의 피로균열 성장특성에 관한 연구)

  • 허용학;이주진;한지원;김종집;문한규
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.96-102
    • /
    • 1990
  • Cracks found in pressure vessels have been reported to be mostly semi-elliptic surface cracks. The fatigue crack growth behaviour of the surface cracks on pressure vessel materials, SPV 50Q and API 5A-K55, was studied with the consideration of the crack opening character. To determine the crack opening loads for the surface cracks, the displacement/strain were measured at three positions; the center and the side of the surface crack, the back face of the specimen using CMOD gauge and strain gauges. The experimental results showed that the crack opening load levels measured at the side of the surface crack were generally a little higher than those measured at the back face. As for the crack growth rates at the different parts of the surface crack, the experiments also showed that, if .DELTA.K$_{eff}$ is used, the exponent n of the Paris' law obtained were the same for the rear and the side parts of the surface cracks.

Development of the Caliper System for a Geometry PIG Based on Magnetic Field Analysis

  • Kim, Dong-Kyu;Cho, Sung-Ho;Park, Seoung-Soo;Yoo, Hui-Ryong;Park, Yong-Woo;Kho, Young-Tai;Park, Gwan-Soo;Park, Sang-Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.12
    • /
    • pp.1835-1843
    • /
    • 2003
  • This paper introduces the development of the caliper system for a geometry PIG (Pipeline Inspection Gauge). The objective of the caliper system is to detect and measure dents, wrinkles, and ovalities affect the pipe structural integrity. The developed caliper system consists of a finger arm, an anisotropic permanent magnet, a back yoke, pins, pinholes and a linear hall effect sensor. The angle displacement of the finger arm is measured by the change of the magnetic field in sensing module. Therefore the sensitivity of the caliper system mainly depends on the magnitude of the magnetic field inside the sensing module. In this research, the ring shaped anisotropic permanent magnet and linear hall effect sensors were used to produce and measure the magnetic field. The structure of the permanent magnet, the back yoke and pinhole positions were optimized that the magnitude of the magnetic field range between a high of 0.1020 Tesla and a low of zero by using three dimensional nonlinear finite element methods. A simulator was fabricated to prove the effectiveness of the developed caliper system and the computational scheme using the finite element method. The experimental results show that the developed caliper system is quite efficient for the geometry PIG with good performance.

Applicability of NIOSH Lifting Equation to analysis of Workload for Patients Transferring (병원 환자 운반 업무의 작업 부하 분석에 NIOSH 들기 작업 공식의 적용 가능성)

  • Gi, Do-Hyeong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.25 no.2
    • /
    • pp.43-50
    • /
    • 2006
  • The purpose of this study was to investigate applicability of NIOSH lifting equation(NLE) to analysis of workload for patient transferring. In principle, the NLE is not applied to analyzing workload of patient transferring, because 1) the task is generally performed by two or more persons; 2) unlike ordinary objects, human body of patients is basically unstable load with their location of the center of mass significantly varying during lifting activity; and 3) the task is done in a restricted work space. This study was conducted through comparison of NIOSH lifting indexes(LIs) and L5/S1 compressive forces by 3DSSPP for patient transferring tasks performed by 2~6 persons. The results showed that LIs are linearly correlated with L5/S1 compressive forces with correlation coefficient of 0.92, which resulted in a significant simple linear regression equation for LIs and L5/S1 compressive forces. Consequently, it was concluded that the NLE is applicable to transferring patient only with slight modification. Based on the results, instead of 1.0 originally used by NIOSH, the LI of 1.5 was proposed as a gauge to estimate whether or not the task needs corrective action to reduce risk for developing lifting-related low back pain.

Measurement of Radiative Heat Flux Using Plate Thermometer (판열유속계를 이용한 복사열유속 측정 실험)

  • Park, Won-Hee;Yoon, Kyung-Beom
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.1
    • /
    • pp.95-98
    • /
    • 2013
  • Plate thermometers are used for measuring the radiative heat flux in high-temperature surroundings. The heat flux is calculated from the temperature measured at the back surface of the stainless steel surface of the meter. Heat fluxes from a Schmidt-Boelter gauge are measured as reference heat fluxes. A combined conductive coefficient is introduced to consider the heat loss to insulation, conduction through the stainless plate depth, and conduction from the non-uniform temperature of the plate of the plate thermometer. This coefficient is obtained using the repulsive particle swarm optimization.

Development of Caliper System for Geometry PIG (지오메트리 피그용 캘리퍼 시스템 개발)

  • Yoo, H.R.;Kim, D.K.;Cho, S.H.;Park, S.H.;Park, S.S.;Park, D.J.;Koo, S.J.;Rho, Y.W.;Park, G.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.228-234
    • /
    • 2001
  • NTMS(Non-contact Tilted-angle Measuring System) is developed by using the principle that the magnetic field of an anisotropic magnet's inner space is uniform and it's possible to measure the strength of the magnetic field using a linear hall effect sensor. In order to implement the caliper system of the geometry PIG(Pipeline Inspection Gauge) which has high accuracy and proper output voltage of the hall sensor without additional driving module or a signal amplifier, it is necessary to consider the size of the magnet, the inner space and back-yoke and the position of pin-hole in the magnet. So the optimal design method of the caliper system is proposed through analysis of NTMS's magnetic field adopting a FEM(Finite Element Method). The experimental results show that the developed caliper system can be used for the geometry pig with good performances.

  • PDF