• 제목/요약/키워드: Back-Gauge

검색결과 55건 처리시간 0.025초

Adaptive mass flow method 유압압하식 자동 두께제어 장치에 관한 연구 (A Study on the Hydraulic Automatic Gauge Control System of Adaptive Mass Flow Method)

  • 윤순현;김문경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제20권4호
    • /
    • pp.101-107
    • /
    • 1996
  • This test was performed on the hydraulic automatic gauge control(AGC) system of adaptive mass flow method. Fundamental purpose of this study are performance evaluation of this AGC system under the actual rolling condition. It was concluded that the response of AGC system depends on the dynamic characteristics of a reel motor or roll position. The test results are as follows : 1) The control method of reel motor current is better than than of the roll position as AGC system. 2) The more steel strip thickness of delivery side is thick, the larger the gauge deviation is large, and the more it is thin, the larger the gauge deviation rate is large. 3) Because the gauge deviation is large at acceleration and deceleration speed than steady speed, so AGC system is better to adopt over 50m/min. By applying this AGC system, not only the accurary in strip thickness were improved but also productivity was improved dramatically.

  • PDF

냉간압연 공정에서의 출측 판두께제어 (Exit strip gauge control for a cold rolling process)

  • 류석환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.525-530
    • /
    • 1992
  • This paper deals with an exit strip gauge controller design for a cold rolling mill process with one input and two outputs. In order to attenuate the exit strip gauge variation caused by the Back-up roll eccentricity and the entry guage variation, an H$_{\infty}$ controller design methodology is used to keep the frequency weighted mixed sensitivity function small. Effectiveness of the proposed controller is demonstrated by a computer simulation..

  • PDF

역전파 신경회로망을 이용한 가공조건에 따른 STD-11 절단면의 신뢰성 평가 (Reliability Evaluation of STD-11 Cutting Surface on the Machined Condition using the Back-Propagation Neural Network)

  • 김선진;성백섭;조규재;김하식;반제삼
    • 한국공작기계학회논문집
    • /
    • 제13권5호
    • /
    • pp.7-15
    • /
    • 2004
  • The purpose of this study was to present the method to choose the optimum machining condition for the wire EDM. This was completed by examining the ever-changing quality of the material and by improving the function of the wire electric discharge machine. Precision metal mold products and the unmanned wire electric discharge machining system were used and then applied in industrial fields. This experiment uses the wire electric discharge machine with brass wire electrode of 0.25mm. To measure the precision of the machining surface, average values are obtained from 3 samples of measures of center-line average roughness by using a third dimension gauge and a stylus surface roughness gauge.

복개 터널구조물의 현장 시공에 따른 계측 분석 사례 (Field Measurements with the Construction of Cut and Cover Tunnel)

  • 박시현;이석원;이규필;배규진;전오성;이종성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.149-156
    • /
    • 2002
  • Field measurements were carried out in this study to investigate the behavior of cut and cover tunnel such as the distribution and the magnitude of the earth pressure during back fill process of the ground material. Three kinds of measuring instruments, such as the earth pressure load cell, the concrete strain gauge and the reinforcing bar meter of embedded type in concrete structure were installed and measured. Earth pressure load cells, installed after construction of the tunnel lining, measure the outside forces acting on the tunnel lining with radial directions. Three load cells were installed at the crown, the right and the left shoulder of the tunnel, respectively. Three sets of reinforcing bar meter were installed in the double reinforcements of the tunnel lining and their locations were the same with the position of the earth pressure load cells. Concrete strain gauge was installed only one site of the upper compressive part at the tunnel crown. Based on the measuring results in the field, the deformation and the earth pressure acting on the tunnel lining were investigated with the back fill process of the ground material. Considerations on the validity of the measuring results were paid. For the analysis of measurements, after dividing back fill process into three steps, various factors which affect on the behavior of tunnel lining were investigated at each step.

  • PDF

A Study on Adapting Patterns to Stable Knit Fabrics in Relation to Drapability

  • Song, Mi-Ryong;Yang, Soo-Yung
    • The International Journal of Costume Culture
    • /
    • 제2권2호
    • /
    • pp.80-96
    • /
    • 1999
  • This research focused on pattern adjustments of the stable knit garment for women. Fourteen different types of the knitted fabrics by 12 gauge, computerized flat bed machines were cut in as one half of the torso front, one half of the torso back, and one side of the sleeves for each of them. Guidelines such as the center front, the center back, the armhole, the bust-line, the waistline, the hip-line the hemline were basted on the torso patterns in the knitted fabrics. Also the grain-line, the elbow-line, and the hemline were basted on the one side of the sleeves in the same as above knitted fabrics. The torso patterns in the knitted fabrics were exhibited on the dress-forms on top of the torso patterns in Muslin, which also have the same guidelines drawn on. The distances between the guidelines on Muslin and those on the knitted fabrics for each set of the sample fabrics were measured every three days for two weeks. The fabric properties of the fourteen knitted fabrics such as fiber contents, stitch density both in the wale and course directions, weight, thickness, stretch & recovery, residual shrinkage, relaxation and drapability were laboratory tested for how these were related to finished appearance of 12 gauge, computerized flat knit garments and also in order to prove the fourteen knitted fabrics fall to a category of such as the stable knit. The results from the investigation revealed that six fabric properties such as stitch density, thickness, stretch recovery, residual shrinkage and relaxation were not so much significant factors as weight and drapability. In conclusion, fabric weight, and drapability of the fabric resulting from fiber contents were the cause of final appearance distortion of garment. When adapting patterns for stabilized, 12 gauge, computerized flat knitted fabrics, the fiber contents of the fabrics should be taken into consideration to reduce the production cost and produce better-fit garments.

  • PDF

좌석의 인간공학적 설계를 위한 인체 등부위 형상 정보 취득에 관한 연구 (On Anthropometrical Data Acquisition of Human Back Surface for Ergonomic Seat Design)

  • 이근부;오세호
    • 대한안전경영과학회지
    • /
    • 제11권4호
    • /
    • pp.69-75
    • /
    • 2009
  • The objective of this study is to develop 3D anthropometrical data acquisition method of human back surface and to recognise and extract its morphological characteristics. This technique is very useful in describing the sitter's back contour and the interaction between the sitter's back and the seat. The back surfaces of subjects in sitting posture are measured by using martine-type anthropometer and sliding gauge. These basic anthropometrical data are reconstructed into 3D image.

휴대용 감마선파이프측후도의 설계와 시작 (Design and Experiment on the Portable Gamma-Ray Pipe Thickness Gauge)

  • 김덕진;김홍식
    • 대한전자공학회논문지
    • /
    • 제4권2호
    • /
    • pp.3-15
    • /
    • 1967
  • 감마선 후방산란을 이용한 철관 두께 측정용 측후계의 설계의 있어서 1/2인치 이하의 얇은 NaI 크리스털을 사용함으로써 계측부에 있어서 1개의 파고선별회로와 Anti-coincidence Circuit를 제거할 수 있다. 이 방식은 종래의 방식에 비하여 훨씬 회로가 경제적이면서도 거의 비슷한 정밀도와 안정도를 유지할 수 있다. 본논문에서는 위와 같은 새로운 방식에 의하여 설계, 시작된 측정기로서 지금까지 타연구자에 의하여 시도되지 않았던 200℃의 고온파이프의 관순측정실험을 행하였던바 상온에서의 측정치보다 불과 5%이내의 변화밖에 가져오지 않음을 실험적으로 확인하였다.

  • PDF

침 근전도로 측정한 만성 요통 환자의 어깨 굴곡시 나타나는 다열근 활성도 비교 (A Study on multifidus muscle activation by Needle EMG during shoulder flexion in Chronic Low Back Pain Patients)

  • 장원석
    • 대한물리치료과학회지
    • /
    • 제18권3호
    • /
    • pp.63-69
    • /
    • 2011
  • Purpose : The purpose of study is activation of lumbar multifidus muscle by needle EMG during shoulder flexion in chronic low back pain patients. The subject were consisted of 10 women patients with chronic low back pain and healthy asymtomatic subject 10 women. Methods : 10 women patients with chronic low back pain and healthy asymptomatic subject 10 women is voluntary participated for the research. Subjects were positioned in standing. The needle EMG were measured activation of multifidus. Needle electrode was used to 28 gauge. The shoulder flexion movement used to activate the multifidus was then measured. Results : Results of the analysis showed that asymptomatic subjects had significantly larger multifidus muscle activation compared with CLBP subjects during shoulder flexion. Conclusion : This study will be used as multifidus measurement method of patient with chronic LBP. The multifidus muscle in chronic LBP patient clinical significance. Most of chronic LBP patients have multifidus contraction pattern. Therefore chronic LBP patients necessary multifidus activation measurement with needle EMG.

  • PDF

L-헤더 시스템의 좌굴 거동에 관한 실험 연구 (Experimental Study on the Buckling Behavior of L-Shaped Header System)

  • 박완순;김갑득
    • 한국강구조학회 논문집
    • /
    • 제14권5호통권60호
    • /
    • pp.665-674
    • /
    • 2002
  • 스틸 스터드 구조물에서 사용되고 있는 기존 I형, 박스형 헤더는 시공성, 경제성 측면에서 여러 가지 문제점을 노출하고 있다. 이러한 문제점을 극복하기 위해 선진국에서는 냉간성형강을 L형으로 절곡한 L-헤더를 활발히 사용하고 있다. 그러나 국내에서는 이에 대한 연구가 부족하여 L-헤더를 사용하지 못하고 있는 실정이다. 본 연구에서는 이러한 문제점을 해결하기 위해 L-헤더에 대한 좌굴해석 및 휨 실험을 수행하였으며, 실험결과를 미국 철강협회(AISI, American Iron and Steel Institute) 설계기준과 비교하였다. 휨 실험결과 중력방향 하중이 작용하는 경우에는 국부좌굴이, 인발하중이 작용하는 경우에는 뒤틀림 좌굴이 발생되는 것으로 관찰되었다. 그리고 실험에서 측정된 좌굴 하중을 비교한 결과 AISI 설계기준에 제시된 공칭하중을 상회하는 것으로 확인되었다.

Bending 30-gauge needles using a needle guide: fatigue life evaluation

  • Jared Joseph Tuttle;Andrew Doran Davidson;Gregory Kent Tuttle
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제23권5호
    • /
    • pp.281-285
    • /
    • 2023
  • Background: Dentists bend needles prior to certain injections; however, there are concerns regarding needle fracture, lumen occlusion, and sharps handling. A previous study found that a 30-gauge needle fractures after four to nine 90° bends. This fatigue life study evaluated how many 90° bends a 30-gauge dental needle will sustain before fracture when bent using a needle guide. Methods: Two operators at Element Materials Technology, an independent testing, inspection, and certification company tested 48 30-gauge needles. After applying the needle guide, the operators bent the needle to a 90° angle and expressed the anesthetic from the tip. The needle was then bent back to a 0° angle, and the functionality was tested again. This process was repeated until the anesthetic failed to pass through the end of the needle due to fracture or obstruction. Each operator tested 24 needles (12 needles from each lot), and the number of sustained bends before the needle fracture was recorded. Results: The average number of sustained bends before needle failure was 40.33 (95% confidence interval = 37.41-43.26), with a minimum of 20, median of 40, and a maximum of 54. In each trial, the lumen remained patent until the needle fractured. The difference between the operators was statistically significant (P < 0.001). No significant differences in performance between needle lots were observed (P = 0.504). Conclusion: Our results suggest that using a needle guide increases the number of sustained bends before needle fracture (P < 0.000001) than those reported in previous studies. Future studies should further evaluate the use of needle guides with other needle types across a variety of operators. Furthermore, additional opportunities lie in exploring workplace safety considerations and clinical applications of anesthetic delivery using a bent needle.