• Title/Summary/Keyword: Back-Gauge

Search Result 55, Processing Time 0.028 seconds

A Study on the Hydraulic Automatic Gauge Control System of Adaptive Mass Flow Method (Adaptive mass flow method 유압압하식 자동 두께제어 장치에 관한 연구)

  • 윤순현;김문경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.4
    • /
    • pp.101-107
    • /
    • 1996
  • This test was performed on the hydraulic automatic gauge control(AGC) system of adaptive mass flow method. Fundamental purpose of this study are performance evaluation of this AGC system under the actual rolling condition. It was concluded that the response of AGC system depends on the dynamic characteristics of a reel motor or roll position. The test results are as follows : 1) The control method of reel motor current is better than than of the roll position as AGC system. 2) The more steel strip thickness of delivery side is thick, the larger the gauge deviation is large, and the more it is thin, the larger the gauge deviation rate is large. 3) Because the gauge deviation is large at acceleration and deceleration speed than steady speed, so AGC system is better to adopt over 50m/min. By applying this AGC system, not only the accurary in strip thickness were improved but also productivity was improved dramatically.

  • PDF

Exit strip gauge control for a cold rolling process (냉간압연 공정에서의 출측 판두께제어)

  • 류석환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.525-530
    • /
    • 1992
  • This paper deals with an exit strip gauge controller design for a cold rolling mill process with one input and two outputs. In order to attenuate the exit strip gauge variation caused by the Back-up roll eccentricity and the entry guage variation, an H$_{\infty}$ controller design methodology is used to keep the frequency weighted mixed sensitivity function small. Effectiveness of the proposed controller is demonstrated by a computer simulation..

  • PDF

Reliability Evaluation of STD-11 Cutting Surface on the Machined Condition using the Back-Propagation Neural Network (역전파 신경회로망을 이용한 가공조건에 따른 STD-11 절단면의 신뢰성 평가)

  • Kim Sun-Jin;Sung Back-Sub;Cho Gyu-Jae;Kim Ha-Sik;Ban Jae-Sam
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.5
    • /
    • pp.7-15
    • /
    • 2004
  • The purpose of this study was to present the method to choose the optimum machining condition for the wire EDM. This was completed by examining the ever-changing quality of the material and by improving the function of the wire electric discharge machine. Precision metal mold products and the unmanned wire electric discharge machining system were used and then applied in industrial fields. This experiment uses the wire electric discharge machine with brass wire electrode of 0.25mm. To measure the precision of the machining surface, average values are obtained from 3 samples of measures of center-line average roughness by using a third dimension gauge and a stylus surface roughness gauge.

Field Measurements with the Construction of Cut and Cover Tunnel (복개 터널구조물의 현장 시공에 따른 계측 분석 사례)

  • 박시현;이석원;이규필;배규진;전오성;이종성
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.149-156
    • /
    • 2002
  • Field measurements were carried out in this study to investigate the behavior of cut and cover tunnel such as the distribution and the magnitude of the earth pressure during back fill process of the ground material. Three kinds of measuring instruments, such as the earth pressure load cell, the concrete strain gauge and the reinforcing bar meter of embedded type in concrete structure were installed and measured. Earth pressure load cells, installed after construction of the tunnel lining, measure the outside forces acting on the tunnel lining with radial directions. Three load cells were installed at the crown, the right and the left shoulder of the tunnel, respectively. Three sets of reinforcing bar meter were installed in the double reinforcements of the tunnel lining and their locations were the same with the position of the earth pressure load cells. Concrete strain gauge was installed only one site of the upper compressive part at the tunnel crown. Based on the measuring results in the field, the deformation and the earth pressure acting on the tunnel lining were investigated with the back fill process of the ground material. Considerations on the validity of the measuring results were paid. For the analysis of measurements, after dividing back fill process into three steps, various factors which affect on the behavior of tunnel lining were investigated at each step.

  • PDF

A Study on Adapting Patterns to Stable Knit Fabrics in Relation to Drapability

  • Song, Mi-Ryong;Yang, Soo-Yung
    • The International Journal of Costume Culture
    • /
    • v.2 no.2
    • /
    • pp.80-96
    • /
    • 1999
  • This research focused on pattern adjustments of the stable knit garment for women. Fourteen different types of the knitted fabrics by 12 gauge, computerized flat bed machines were cut in as one half of the torso front, one half of the torso back, and one side of the sleeves for each of them. Guidelines such as the center front, the center back, the armhole, the bust-line, the waistline, the hip-line the hemline were basted on the torso patterns in the knitted fabrics. Also the grain-line, the elbow-line, and the hemline were basted on the one side of the sleeves in the same as above knitted fabrics. The torso patterns in the knitted fabrics were exhibited on the dress-forms on top of the torso patterns in Muslin, which also have the same guidelines drawn on. The distances between the guidelines on Muslin and those on the knitted fabrics for each set of the sample fabrics were measured every three days for two weeks. The fabric properties of the fourteen knitted fabrics such as fiber contents, stitch density both in the wale and course directions, weight, thickness, stretch & recovery, residual shrinkage, relaxation and drapability were laboratory tested for how these were related to finished appearance of 12 gauge, computerized flat knit garments and also in order to prove the fourteen knitted fabrics fall to a category of such as the stable knit. The results from the investigation revealed that six fabric properties such as stitch density, thickness, stretch recovery, residual shrinkage and relaxation were not so much significant factors as weight and drapability. In conclusion, fabric weight, and drapability of the fabric resulting from fiber contents were the cause of final appearance distortion of garment. When adapting patterns for stabilized, 12 gauge, computerized flat knitted fabrics, the fiber contents of the fabrics should be taken into consideration to reduce the production cost and produce better-fit garments.

  • PDF

On Anthropometrical Data Acquisition of Human Back Surface for Ergonomic Seat Design (좌석의 인간공학적 설계를 위한 인체 등부위 형상 정보 취득에 관한 연구)

  • Lee, Keun-Boo;Oh, Se-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.4
    • /
    • pp.69-75
    • /
    • 2009
  • The objective of this study is to develop 3D anthropometrical data acquisition method of human back surface and to recognise and extract its morphological characteristics. This technique is very useful in describing the sitter's back contour and the interaction between the sitter's back and the seat. The back surfaces of subjects in sitting posture are measured by using martine-type anthropometer and sliding gauge. These basic anthropometrical data are reconstructed into 3D image.

Design and Experiment on the Portable Gamma-Ray Pipe Thickness Gauge (휴대용 감마선파이프측후도의 설계와 시작)

  • 김덕진;김홍식
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.4 no.2
    • /
    • pp.3-15
    • /
    • 1967
  • In the design of a portable Gamma-ray transistorized steel pipe thickness gauge, a pulse height discriminator and an anti-coincidence circuit could be eliminated by using a thin, less than 1/2inch, NaI(Tl) scintillation crystal in the detecting probe. This method could provide an economic design and fabrication of a gamma-ray back-scattering gauge allowing allmost the same accuracy and stability compared with the exsisting method. A gauge had been designed and fabricated with the above method and its accuracy was experimentall tested for the 200$^{\circ}C$ high temperature steel pipes. The result showed that the thermal drift was less than y percent which was acceptabel in the practical applications.

  • PDF

A Study on multifidus muscle activation by Needle EMG during shoulder flexion in Chronic Low Back Pain Patients (침 근전도로 측정한 만성 요통 환자의 어깨 굴곡시 나타나는 다열근 활성도 비교)

  • Jang, Won-Seok
    • Journal of Korean Physical Therapy Science
    • /
    • v.18 no.3
    • /
    • pp.63-69
    • /
    • 2011
  • Purpose : The purpose of study is activation of lumbar multifidus muscle by needle EMG during shoulder flexion in chronic low back pain patients. The subject were consisted of 10 women patients with chronic low back pain and healthy asymtomatic subject 10 women. Methods : 10 women patients with chronic low back pain and healthy asymptomatic subject 10 women is voluntary participated for the research. Subjects were positioned in standing. The needle EMG were measured activation of multifidus. Needle electrode was used to 28 gauge. The shoulder flexion movement used to activate the multifidus was then measured. Results : Results of the analysis showed that asymptomatic subjects had significantly larger multifidus muscle activation compared with CLBP subjects during shoulder flexion. Conclusion : This study will be used as multifidus measurement method of patient with chronic LBP. The multifidus muscle in chronic LBP patient clinical significance. Most of chronic LBP patients have multifidus contraction pattern. Therefore chronic LBP patients necessary multifidus activation measurement with needle EMG.

  • PDF

Experimental Study on the Buckling Behavior of L-Shaped Header System (L-헤더 시스템의 좌굴 거동에 관한 실험 연구)

  • Park, Wan Soon;Kim, Gap Deuk
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.5 s.60
    • /
    • pp.665-674
    • /
    • 2002
  • The back-to-back and box-shaped headers used in light gauge steel structures have some disadvantages, i.e., construction efficiency and cost competitiveness. As such, cold-formed steel L-shaped headers have been developed and are used actively in advanced nations. However, this system has not been used in Korea because of inadequate investigation and adaptation efforts and lack of application example. Thus, this research evaluated the structural performance of L-header using buckling analyses and bending tests. Test results were compared using the AISI design criteria. Test results showed that local buckling and distortional buckling governed buckling behavior in gravity loads and uplift loads, respectively. These results were consistent with the calculated nomial strengths using the AISI design criteria.

Bending 30-gauge needles using a needle guide: fatigue life evaluation

  • Jared Joseph Tuttle;Andrew Doran Davidson;Gregory Kent Tuttle
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.23 no.5
    • /
    • pp.281-285
    • /
    • 2023
  • Background: Dentists bend needles prior to certain injections; however, there are concerns regarding needle fracture, lumen occlusion, and sharps handling. A previous study found that a 30-gauge needle fractures after four to nine 90° bends. This fatigue life study evaluated how many 90° bends a 30-gauge dental needle will sustain before fracture when bent using a needle guide. Methods: Two operators at Element Materials Technology, an independent testing, inspection, and certification company tested 48 30-gauge needles. After applying the needle guide, the operators bent the needle to a 90° angle and expressed the anesthetic from the tip. The needle was then bent back to a 0° angle, and the functionality was tested again. This process was repeated until the anesthetic failed to pass through the end of the needle due to fracture or obstruction. Each operator tested 24 needles (12 needles from each lot), and the number of sustained bends before the needle fracture was recorded. Results: The average number of sustained bends before needle failure was 40.33 (95% confidence interval = 37.41-43.26), with a minimum of 20, median of 40, and a maximum of 54. In each trial, the lumen remained patent until the needle fractured. The difference between the operators was statistically significant (P < 0.001). No significant differences in performance between needle lots were observed (P = 0.504). Conclusion: Our results suggest that using a needle guide increases the number of sustained bends before needle fracture (P < 0.000001) than those reported in previous studies. Future studies should further evaluate the use of needle guides with other needle types across a variety of operators. Furthermore, additional opportunities lie in exploring workplace safety considerations and clinical applications of anesthetic delivery using a bent needle.