• Title/Summary/Keyword: Back Flush

Search Result 15, Processing Time 0.022 seconds

Warping and Buckling Prediction Model of Wooden Hollow Core Flush Door due to Moisture Content Change (I) : Comparison of Prediction Model with Experimental Results (목제(木製) 프러쉬 문의 함수율 변동에 따른 틀어짐과 좌굴 예측모델 (I) : 예측모델과 실측치 비교)

  • Kang, Wook;Jung, Hee-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.99-116
    • /
    • 1999
  • Wooden hollow core flush door is one of the main products of furniture manufacturing and woodworking industries. Warping and buckling of the door is serious problems in service. It has been reported that warping is caused by differences of physical and mechanical properties of face and back of skin panel for the door. This study focused on the prediction of warping and buckling phenomena of the flush door using numerical models. Predictions from the models were also compared with the experimental results obtained from the doors with plywood and hardboard skin panels under various environmental conditions. Three elastic constitutive models, so called elastic beam model, plate model and plate-buckling model, were employed to predict warping and buckling of the doors. It was observed that warping was more pronounced in low humidity condition than in high humidity condition. The plate model considering Poisson's effect was reliable to predict warping more closely than elastic beam model in low humidity condition. The plate-buckling model, however, was the best in the fitting of predictions with the experimental results under high humidity condition because buckling was developed in face and back of skin panel at that condition.

  • PDF

A Study on Economic benefits for Water Control Device Installed with a Flush Valve on a Toilet (세척밸브 급수제어장치 설치에 따른 경제적 효과 분석)

  • Park, Kang-Hyun;Kim, Su-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.10
    • /
    • pp.656-661
    • /
    • 2011
  • The amount of water resources that can be used tend to be decreased gradually. In contrast, the rapidly increasing water consumption is a problem that need to be addressed. Renovation and equipment replacement to improve energy efficiency and to reduce expenditure for building usage is required. But the excessive initial investment cost and the prolonged of pay back period may be uneconomical choice. Water usage for cleaning the toilet bowl accounts for 27%of the total water usage. Water-saving valve that can select the amount of water for cleaning toilet bowl can be reduced expenditure. After installing water-saving valve, analysed the economic effects. Water-saving valves compared with flush valves, and researched the amount of water usage. Then analyzed for the economic effects. Water-saving valve was used 5.6 ${\ell}$/time for cleaning toilet bowl. In contrast, flush valve was consumed 8.4 ${\ell}$/time. Water-saving valve's water-saving rate was 33.3%. The initial payback period for Water-saving valve was 459.5 days. By a small investment in water saving valve, the economic benefits can be obtained.

On-line Trace Enrichment for the Determination of Insulin in Biological Samples Using Reversed-Phase High Performance Liquid Chromatography with Column Switching

  • Lee, Jung-Sook;Lee, Heeyong;Lee, Hye-Suk;Lee, Kang-Choon
    • Archives of Pharmacal Research
    • /
    • v.17 no.5
    • /
    • pp.360-363
    • /
    • 1994
  • Column--swtiching technique with a reversed-phase high performance liquid chromatographic method has been developed for the routine analysis of radioiodinated insulin and its degadation products in biological fluids. The diluted biological samples were loaded onto a precolumn packed with LiChrosorb RP-8 $(25-40{\;}{\mu}m)$ using 0.1% trifuoroacetic acid (TFA) in water as a washing solvent. After valve switching, the concentrated insulins were eluted in the back-flush mode and separated by a W-Porex $C_{18}$ column with a gradient of 0.1% TFA in water and 0.1% TFA in acetonitrile as the mobile phase. The method showed good precision, accuracy and speed with the detection limit of 20 pg/ml. Total analysis time per sample was about 40 min and the coefficients of variation were less than 8, 2%.

  • PDF

Determination of Omeprazole in Rat Plasma by HPLC with Column Switching

  • Shim, Sang-Ho;Bok, Soo-Jin;Kwon, Kwang-Il
    • Archives of Pharmacal Research
    • /
    • v.17 no.6
    • /
    • pp.458-461
    • /
    • 1994
  • A new high-performance liquid chromatographic method with column switching has been onto a Bondapak phenyl/corsil $(37-50{\;}{\mu}m)$ precolumn and polar plasma components were washed with 0.06 M borate burffer. After valve switching, the concentrated drug were eluted in the back-flush mode and separated on a ${\mu}-Bondapak$ C18 column with acetonitrilke-phosphate buffer as the mobile phae. The method showed excellent precision, accuracy and speed with detection limit of $0.01{\;}{\mug}/ml^{-1}$. Total analysis time per smaple was less than 20 min and the coefficients of variation for intra and inter-assay were less than 5.635. This method has been successfully applied to plasma smaples from eats after oral administration of omeprazole.

  • PDF

A Study on the Improvement Repeatability and Accuracy of the Analysis Method for SF6 of Trace Level (극미량 수준의 SF6 측정법에 따른 재현성 및 정확도 향상에 관한 연구)

  • Yoo, Heejung;Choe, Hongwoo;Lee, Sepyo;Kim, Jongho;Han, Sangok;Ryoo, Sangboom
    • Journal of the Korean Society of Urban Environment
    • /
    • v.18 no.4
    • /
    • pp.523-530
    • /
    • 2018
  • Kyoto Protocol, adopted in 1997, set the obligation to reduce $CO_2$, $CH_4$, $N_2O$, HFCs, PFCs, and $SF_6$ in developed countries during 1st promised period. $SF_6$ has been drawing a lot of attention since the Kyoto Protocol because once it is released into the atmosphere, it not only stays in the atmosphere for more than 3,200 years but also emits 22,800 times stronger global warming potential at the same concentrations as $CO_2$ if remains in the atmosphere for 100 years. This study introduces 12 methods for $SF_6$ of measuring trace. $SF_6$ of trace level in the atmosphere correctly, the measurement method was changed and as a result, when the back flush method was applied to the pre-concentration system that used low-temperature concentration and high-temperature desorption system, which used Carboxen-1000 adsorption trap, the effect was the best.

Review on the Jaeumkangwha-tang in Hyungsang Medicine (자음항화탕의 형상의학적 고찰)

  • Jung Heung Shik;Kang Kyung Hwa;Lee Yong Tae
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.18 no.4
    • /
    • pp.982-989
    • /
    • 2004
  • The following is the conclusion drawn from a review on the clinical cases cured by Jaeumkangwha-tang in perspective of Hyungsang medicine. Jaeumkangwha-tang originated from the modified Jibaiksamul-tang in 'Manbyunghuichun(萬病回春)' and applied to the diseases induced by flaming fire due to deficiency of Yin. In 'Donguibogam', there are two kinds of Jaeumkangwha-tang. One in the chapter of kidney is mainly prescribed to replenish the Jung of kidney and applicable to the cases with configuration and symptom of kidney along with fire. The other one in the chapter of fire is applied to the symptoms of flaming fire due to deficiency of Yin. The characteristics of the patients treated by Jaeumkangwha-tang from the viewpoint of Hyungsang medicine can be classified as follows : ① configuration: Dam type, Shin type, inverted triangular type(:天垂象), bird type, round eyes, thin lips, slender waist, thin leg, pretty face, sparkling eyes, prominent upper lip and upward eyes and nose. ② color : dark red complexion, red cheek bone, red lips and red glabella. ③ pulse : fine and fast pulse and pulsation on the Chuk(尺) in man and so forth. ④ symptoms: agility, talkativeness, pimpled face, crooked back, weakness to the heat of summer, light eating, timidity, blood-shot eyes, night sweat, cough, abundant phlegm, hemoptysis, bloody spittle, enervation, emaciation, back pain, flaccidity of lower limbs, involuntary emission, nocturnal emission, heat sensation in the chest palms and soles, anger, flush on cheek bone, red lips and dry mouth, reddish tongue, stiff excrement, scanty yellow urine, etc.

A Study on Digital Infrared Thermographic Imaging Characters of Women Suffering from Postpartum Disease (산후풍 환자의 적외선 체열 영상 특성에 대한 연구)

  • Park, Kyoung-Sun;Lee, Yoon-Jae;Hwang, Deok-Sang;Lee, Jin-Moo;Lee, Chang-Hoon;Cho, Jung-Hoon;Jang, Jun-Bock;Lee, Kyung-Sub
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.23 no.2
    • /
    • pp.116-123
    • /
    • 2010
  • Purpose: During Postpartum period many women complain multiple pain, cold hypersensitivity, hot flush, sweating and so on. We call the postpartum disease as San Hu Pung. We studied DITI Characters of women suffering from Postpartum disease. Methods: We studied 74 postpartum women visiting OOhospital from February 2006 to December 2009. The subjects were categorized in two groups, symptom group and no symptom group. We measured the temperatures of abdomen, upper and lower limb and back. We studied the difference of DITI between two groups by Student T-test using SPSS for windows(version 17.0). Results: The general characteristics were not different statistically. Temperatures of abdomen and back of two groups were not different statistically. Temperatures of both LR3 of symptom group were statistically higher than no symptom group. The difference of both PC8 and LU4, both LR3 and ST32 of symptom group were statistically higher than no symptom group. Conclusion: The results suggest that women suffering from Postpartum disease shows high temperatures on hand and foot. It seems that postpartum disease patients tend to have blood deficiency. DITI can be useful to diagnose San Hu Pung. More studies to diagnose San Hu Pung would be needed.

A Case Study with Gyejigabuja-tang on the Menopausal Female Patient who Complained of Excessive Sweating After Bilateral Salpingo-oophorectomy (양측난소절제술 후 발생한 한출과다(汗出過多)를 주소로 하는 갱년기증후군 환자에 대한 계지가부자탕(桂枝加附子湯) 치험 1례)

  • Kim, Jin-Woo;Park, Kang-In;Park, Kyoung-Sun;Lee, Jin-Moo
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.26 no.4
    • /
    • pp.213-222
    • /
    • 2013
  • Purpose: The purpose of this study is to evaluate the effects of Gyejigabuja-tang on a menopausal female patient complained of excessive sweating after bilateral salpingo-oophorectomy (BSO). Methods: We studied one menopausal female patient complained of excessive sweating who visited OO University Hospital from 10th July 2013 to 23th July 2013. We only treated her with Gyejigabuja-tang. The climacteric symptoms of the patient had been estimated with Numeric Rating Scale (NRS) and Menopause Rating Scale (MRS). Results: After treatment, climacteric symptoms were improved and the score of MRS was reduced from 20 to 10 during 12days. NRS score of sweating was reduced from 10 to 2. NRS scores of fatigue, hot flush, thirst, anorexia, dyspepsia, back pain and cramp of calves also reduced after treatment. Conclusions: This study suggests that Gyejigabuja-tang significantly reduced the climacteric symptoms of patient.

An analysis of the Relationship between Depression and Menopausal Syndroms in Women at Midlife (중년여성의 우울증과 폐경증후군과의 관계)

  • Chung, Eun-Soon
    • Women's Health Nursing
    • /
    • v.3 no.2
    • /
    • pp.268-281
    • /
    • 1997
  • This study was done for the purpose of analysing the relationship between menopausal syndrome and depression in the pre and post menopausal women's group. Data were collected by a questionnaire from November, 1995 to December, 1996. The subject were 244 midlife women(94 subjects were in pre-menopausal period, 150 subject were in post-menopausal period). The instruments used for this study were the menopausal syndrome scale by Neugarton and depression scale by Zung. Data were analyzed with the SPSS/PC using frequency, t-test, and Pearson correlation coefficients. The results of this study were as follows ; 1. The most serious menopausal symptom in the midlife women was 'back pain and joint pain'. 2. The item of 'Hot flush'(t=-2.78, p<0.01), 'sweating'(t=-2.31, p<0.05) and 'nervousness'(t=-2.13, p<0.05) as menopausal syndromes were statistically significant in the two groups ; Post menopausal group were higher then premenopausal group. 3. Postmenopausal group were a little higher then premenopausal group as depression level. It was none statistically significant in the two groups. 4. The relationship between menopausal syndromes and the level of depression was statistically significant in the group of post-menopausal group(r=0.2083, p<0.01).

  • PDF

A STUDY ON THE MICROBIAL CONTAMINATION OF DENTAL UNIT AND ULTRASONIC SCALER (덴탈유니트의 핸드피스 및 초음파 치석 제거기의 미생물 오염에 관한 연구)

  • Lee, Byung-Moon;Kim, Chang-Whe;Kim, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.1
    • /
    • pp.64-80
    • /
    • 1998
  • The risk of cross-contamination in dental clinic is very high. Those who are engaged in dental clinic are exposed to various microorganisms in saliva and blood of patient. Potential possibility of cross-contamination of patient to patient, patient to dentist, dentist to laboratory technician always exist, which is important in the view of public health. It is well known that microorganisms may cause cross-contamination by suck-back of microorganisms into the water supply line or air supply line of dental unit and sprayed back into the next patient's oral cavity. The majority of microorganisms coming from dental unit are water microorganisms from the main water supply which have colonized the tube within the units and multiplied in the relatively warm and stagnant conditions. The purpose of this study is to measure the extent of microbial contamination of dental unit and ultrasonic scaler, to evaluate that dental unit water supply is suitable for drinking water, and to assess the effect of flushing on reduction of microbial contamination of dental unit and ultrasonic scaler. In the first experiment, water samples(50ml) from 20 dental units and 10 ultrasonic scalers in Seoul National Univ. Hosp. were tested for the presence of coliform. The samples were filtered by membrane filtration technique.(Microfil system, Millipore Co. U. S. A.) The filter was then placed onto MacConkey agar plate and the plates with filter on it were incubated aerobically at $37^{\circ}C$ for 5 days. The colors and shapes of colonies were examined if those were coliform. To verify the presence of coliform, the colonies were inoculated into phenol red lactose broth and incubated aerobically at $37^{\circ}C$ for 2 days. The fomation of gas was observed. In the second experiment, water samples from 20 handpieces, 10 ultrasonic scalers and 30 A/W syringes after 0, 2, 4, 6 min. flushing respectively were taken. $200{\mu}l$ water samples were spreaded on Brain Heart Infusion agar plate and the plates were incubated aerobically at $37^{\circ}C$ for 5 days. The number of colony was counted. The results obtained were summarized as follows 1. The water from dental unit and ultrasonic scaler was not suitable for drinking water. 2. No coliform was founded in dental unit and ultrasonic scaler water supply. 3. The number of colony of dental unit and ultrasonic scaler was highest in the group of o min. flushing(p<0.05). 4. There was no statistically significant difference in the extent of microbial contamination among handpiece, ultrasonic scaler and A/W syringe (p>0.05). 5. The number of colony was lowest in the group of 4 min. flushing, but there was no statistically significant difference among 2, 4, 6 min. flushing groups.(p>0.05) 6. It is recommended to flush dental unit water line for 4 min. after use on each patient.

  • PDF