• Title/Summary/Keyword: BX And

Search Result 319, Processing Time 0.026 seconds

Flexural Properties of Heat-Treatment Samama (Anthocephalus macrophyllus) Wood Impregnated by Boron and Methyl Metacrylate

  • CAHYONO, Tekat Dwi;DARMAWAN, Wayan;PRIADI, Trisna;ISWANTO, Apri Heri
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.1
    • /
    • pp.76-85
    • /
    • 2020
  • This study was conducted to analyze the application of boron compounds, methyl methacrylate (MMA), and heat treatment (HT) on changes in the density, moisture content, and flexural properties of samama (Anthocephalus macrophyllus) wood. Samama wood was impregnated with borax (BX) and boric acid (BA) using a pressure method at 5 atm for 4 h. Afterwards, the wood was impregnated with MMA at the same pressure and duration. Finally, the samama wood was given HT at 90 ℃ and 180 ℃. The results indicate that there was a weight gain of 93.4% in the wood impregnated using BA and MMA monomer and HT at 90 ℃. Consequently, the wood's density increased by 82.3%. Increased MOE and MOR percentages of 32.2% and 29.4%, respectively, were also found. HT at 180 ℃ degraded the wood components and MMA, and consequently, the density, MOE, and MOR also decreased. The wood impregnated by BX, BA, and MMA, and subjected to HT also had decreased moisture content (MC). This research recommends that the application of boron (BX, BA) should be combined with an MMA monomer and HT at 90 ℃ as an alternative method to improve samama wood quality. If darker color is preferable, HT should be conducted at 180 ℃.

The Solar-Type Contact Binary BX Pegasi Revisited

  • Lee, Jae-Woo;Kim, Seung-Lee;Lee, Chung-Uk;Youn, Jae-Hyuck
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.24.2-24.2
    • /
    • 2009
  • We present the results of new CCD photometry for the contact binary BX Peg, made during three successive months beginning on September 2008. As do historical light curves, our observations display an O'Connell effect and the November data by themselves indicate clear evidence for very short-time brightness disturbance. For these variations, model spots are applied separately to the two data set of Group I (Sep.--Oct.) and Group II (Nov.). The former is described by a single cool spot on the secondary photosphere and the latter by a two-spot model with a cool spot on the cool star and a hot one on either star. These are generalized manifestations of the magnetic activity of the binary system. Twenty light-curve timings calculated from Wilson-Devinney code were used for a period study, together with all other minimum epochs. The complex period changes of BX Peg can be sorted into a secular period decrease caused dominantly by angular momentum loss due to magnetic stellar wind braking, a light-travel-time (LTT) effect due to the gravitational effect of a low-mass third companion, and a previously unknown short-term oscillation. This last period modulation could be produced either by a second LTT orbit with a period of about 16 yr due to the existence of a fourth body or by the effect of magnetic activity with a cycle length of about 12 yr.

  • PDF

Investigation on the Excitonic Luminescence Properties of ZnO Bulk Crystal (ZnO 기판의 불순물 속박 엑시톤 발광을 이용한 물성 분석)

  • Choi, Jun Seck;Ko, Dong Wan;Jeong, Min Ji;Lee, Sang Tae;Chang, Ji Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.3
    • /
    • pp.196-200
    • /
    • 2019
  • In this study, photoluminescence (PL) analysis was performed to evaluate the optical properties of commercial ZnO substrates. Particular attention was paid to the bound exciton (BX) luminescence, which is usually the strongest emission intensity of commercial substrates. At 15 K, PL analysis revealed that the BX peak due to donor-type impurities (donor-bound-exciton; DX) dominated, while two-electron satellite (TES) emission, donor-accepter pair (DAP) emission, and LO-phonon replica emission were also observed. The impurity concentration of the ZnO substrate was determined to be $10^{15}$ to $10^{16}/cm^3$ by examination of the temperature variation of DAP, while the half width and intensity change of the luminescence revealed that the temperature change of BX can be interpreted almost the same as the analysis of free-exciton emission.

Quality Characteristics of Takju by Yeast Strain Type (효모의 종류에 따른 탁주의 품질특성 변화)

  • Jeon, Hyejeong;Yu, Jae Chul;Kim, Gyewon;Kong, Hong-Sik
    • The Korean Journal of Food And Nutrition
    • /
    • v.27 no.5
    • /
    • pp.971-978
    • /
    • 2014
  • Investigation of the quality characteristics of Takju brewing mashes prepared with several different yeasts was carried out during the 42-day brewing process, including examination of titratable acidity, amino acid content, sugar contents, alcohol contents, pH, reducing sugar, yeast population, lactic acid bacteria, and sensory evaluation. Fermivin yielded the highest titratable acidity, while la parisienne had the lowest. Fermivin also had the highest value of amino acid content (14.33%), while other yeasts shows period tended to increase over exclude Instaferm and Song chun. The amount of sugars in instaferm ($11.33^{\circ}Bx$) and instaferm red ($10.53^{\circ}Bx$) were higher than those in La parisienne red and Song chun ($9.57^{\circ}Bx$). The alcohol contents of instaferm was the highest value (15.20%) while the alchol content of the other yeasts tended to increase the fementation period. Fermivin had the highest pH at $12^{th}$ day among the yeasts(4.02), Instaferm red had the lowest pH among the yeasts (3.87) while safbrew wb-06 had the highest reducing sugar content(117.60 mg/mL). Instaferm obtained the highest preference in the sensory evaluation for all items.

MS-5, a Naphthalene Derivative, Induces Apoptosis in Human Pancreatic Cancer BxPC-3 Cells by Modulating Reactive Oxygen Species

  • Suman Giri;Gyu Hwan Park;Joon-Seok Choi;Eunsook Ma;Kyung-Soo Chun;Sang Hoon Joo
    • Biomolecules & Therapeutics
    • /
    • v.31 no.1
    • /
    • pp.68-72
    • /
    • 2023
  • Pancreatic cancer is one of the most fatal cancers with a poor prognosis. Standard chemotherapies have proven largely ineffective because of their toxicity and the development of resistance. Therefore, there is an urgent need to develop novel therapies. In this study, we investigated the antitumor activity of MS-5, a naphthalene derivative, on BxPC-3, a human pancreatic cancer cell line. We observed that MS-5 was cytotoxic to BxPC-3 cells, as well as inhibited the growth of cells in a concentration- and time- dependent manner. Flow cytometry analysis revealed that the percentage of annexin V-positive cells increased after MS-5 treatment. We also observed cleavage of caspases and poly (ADP-ribose) polymerase, and downregulation of Bcl-xL protein. Flow cytometry analysis of intracellular levels of reactive oxygen species (ROS) and mitochondrial superoxide suggested that MS-5 induced the generation of mitochondrial superoxide while lowering the overall intracellular ROS levels. Thus, MS-5 may be potential candidate for pancreatic cancer treatment.

Number of Different Solutions to x5+bx3+b2mx2+1=0 over GF(2n) (GF(2n)위에서 x5+bx3+b2mx2+1=0의 서로 다른 해의 개수)

  • Choi, Un-Sook;Cho, Sung-Jin
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.11
    • /
    • pp.1749-1754
    • /
    • 2013
  • Binary sequences of period $2^n-1$ are widely used in many areas of engineering and sciences. Some well-known applications include coding theory, code-division multiple-access (CDMA) communications, and stream cipher systems. In this paper we analyze different solutions to $x^5+bx^3+b^{2^m}x^2+1=0$ over $GF(2^n)$. The number of different solutions determines frequencies of cross-correlations of nonlinear binary sequences generated by $d=3{\cdot}2^m-2$, n=2m, m=4k($k{\geq}2$). Also we give an algorithm for determination of number of different solutions to the equation.

Protective effects of red ginseng treated with gold nanoparticles against H2O2-induced oxidative stress in neuronal PC-12 cells (금 나노입자를 처리한 홍삼의 산화스트레스 완화 및 PC-12 신경세포 보호)

  • Kim, Ji Won;Cho, Chi Heung;Hwang, Yun-Gu;Park, Woo Jung;Kang, Hee;Kim, Dae-Ok
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.2
    • /
    • pp.222-227
    • /
    • 2017
  • Red ginseng prepared from fresh 6-year-old ginseng treated with colloidal gold nanoparticles was extracted using hot water to evaluate its total phenolic and flavonoid contents, antioxidant capacity, and neuroprotective effects. Water extract of red ginseng treated with gold nanoparticles (WERGGN) had total phenolic and total flavonoid contents of 212.2 mg gallic acid equivalents/$^{\circ}Bx$ and 3.5 mg catechin equivalents/$^{\circ}Bx$, respectively. The antioxidant capacities of WERGGN measured using ABTS, DPPH, and ORAC assays were 272.3, 141.2, and 868.4 mg vitamin C equivalents/$^{\circ}Bx$, respectively. The WERGGN showed protective effects on the viability of neuron-like PC-12 cells against oxidative stress induced by hydrogen peroxide in a dose-dependent manner, partly because of a reduction in intracellular oxidative stress. Acetylcholinesterase and butyrylcholinesterase, which degrade the neurotransmitter acetylcholine to terminate neurotransmission, were inhibited by treatment with WERGGN. These results suggest that WERGGN is useful as a functional material to decrease oxidative stress and neuronal damage.

Quality Characteristics of Rice Wort and Rice Beer by Rice Processing (쌀 가공처리에 따른 쌀 맥즙 및 쌀 맥주의 품질특성)

  • Park, Jiyoung;Lee, Seuk-Ki;Choi, Induck;Choi, Hye-Sun;Kim, Namgeol;Shin, Dong Sun;Jeong, Kwang-Ho;Park, Chang-Hwan;Oh, Sea-Kwan
    • Food Engineering Progress
    • /
    • v.23 no.4
    • /
    • pp.290-296
    • /
    • 2019
  • Rice in Korea is a highly valuable food resource that serves both as staple food and ingredient in various processed edibles. This study was conducted to explore pre-treatment methods for rice that result in good saccharification upon production of rice beer. When rice was subjected to fine grinding, steeping, roasting, gelatinizing, or puffing prior to saccharification with malt, wort containing puffed rice had the highest soluble solid content (°Bx). Upon production of wort without the addition of any enzymes for liquefaction or saccharification, the addition of 30% rice resulted in the highest soluble solid content (°Bx). Production of beer containing 10, 20, or 30% of either roasted or puffed rice showed that wort containing 30% puffed rice had the highest soluble solid content (15.4 °Bx) with good saccharification. The resulting beer likewise exhibited higher alcohol content (5.0-5.4%) than the beer that had roasted rice added, without the turbidity and with less bitterness. Therefore, rice puffing was considered a beneficial processing method to enhance rice saccharification and to facilitate both the production of fine quality beers and rice beer containing puffed rice.

Image and Exposure Dose in Accordance with Radiation Quality on Plain Chest Radiography (흉부촬영(胸部撮影)에서 증감지(增感紙)-필름계의 선질변화(線質變化)에 따른 감도(感度)와 화질에 관(關)한 연구(硏究))

  • Kim, Jung-Min;Kim, Dong-Huan;Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakura, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.65-78
    • /
    • 1992
  • Routine chest radiography is generally imaged by high voltage technique but some radiological technologists use low voltage for imaging. High voltage is usually said between $120\;kV{\sim}140\;kV$. Some RTs like using heavy filtration but others seldom like using it. However which is better for use calcium tungustate film screen system or ortho system and high contrast film or wide latitude c-type film for the exculusive use of chest radiography. We could not make a decision which is ideal method for use. In my opinion any method is not always exellent for chest radiography. In my experiments that I had at Kaken hospital in Japan last year I expect to keep the balance between image quality and diagnostic range and to reduce radiation dose for patients. My experiments are as follows. 1. We have looked into system characteristics(speed and contrast) in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems(BX3+CRONEX4, SRO750+MGH, SRO750+MGL). 2. We have looked into skin dose and film dose with same D=1.8 lung field density in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems. 3. We have compared with the evaluation between correlation of physical image quality(MTF) and optical diagnostic capability. Result are follows. 1. Speed of BX3+CRONEX4 became higher in accodance with kVp and thickness of filter but speed of ortho system was not as like regular system. Thicker filter diminished the speed over 100 kV range in SRO750+MGL. In case of SRO750+MGH speed of 1/16VL filter was looked into lower than speed of 1/4VL filter. Sensitivity of ortho system depends on tube voltage and added filter. 2. Skin dose has been detected $225\;{\mu}Gy{\sim}66\;{\mu}Gy$ in BX3+CRONEX4 from 80 kV, no filter to 140 kV, 1/16VL filter. SRO750+MGH could reduce the patient dose $1/2{\sim}1/3$ level in comparison to that of BX3+CRONEX4. 3. The higher kV was the worse MTF became the thicker filter was the worse MTF became too. MTF of BX3+CRONEX4 was detected better than MTF of SRO750+MGH but SRO750+MGH's optical detectability of small lesion in lung field came out better than that of BX3+CRONEX4. Conclusion Recently routine chest radiography is generally imaged by high voltage but it seems to be there are some questions in using of film screen combination. In high voltage chest radiography the subject contrast will come down that means latitude become wider. In this case if we select the low contrast film screen system(C or L type) the film contrast will fall down extremly and detectability of small lesion will be deteriorated. Wide latitude C, L type film has a merit of high detectability on mediastinum. Furthermore high contrast film screen system has the advantage to keep the high contrast in low density region as like mediastinum and heart shadow. Therefore in low subject contrast high voltage chest radiography we would rather choose the high contrast film screen system(H type) I think. From a view point of patient dose detectability of mediastinum and lung field. The optimum technical facter was found out 120 kV, 1/16VL filter : BX3+CRONEX4, 140 kV, 1/4VL filter : SRO750+MGH, 100 kV, 1/4VL filter : SRO750+MGL.

  • PDF