• Title/Summary/Keyword: BUS

Search Result 3,847, Processing Time 0.049 seconds

A design of P1394 serial bus IC (P1394 시리얼 버스 IC의 설계)

  • 이강윤;정덕균
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.1
    • /
    • pp.34-41
    • /
    • 1998
  • In this paper, I designed a P1394 serial bus chip as new bus interface architecture which can transmit the multimedia data at the rate of 400 Mbps and guarantee necessary bandwidth. because multimedia data become meaningless data after appropriate time, it is necessary to transfer multimedia data in real time, P1394 serial bus chip designed in this paper support isochronous transfer mode to solve this problem. Also, designed P1394 serial bus chip can transfer high quality video data or high quality audio data because it support the speed of 400 Mbps. While user must set device ID manually in previous interface such as SCSI, device ID is automatically determined if user connect each node with designed P1394 serial bus cable and power on. To design this chip, I verified the behavioral of the entrire system and synthesized layout. Also, I did layout the analog blocks and blocks which must be optimized in full custom.

  • PDF

On Installation of Bus Trunk System for Wind Tower (풍력타워용 부스닥트 포설시스템 개발)

  • Lee, Joon-Keun;Kim, Bong-Seok;Park, Seong-Hee;Ahn, Hyung-Joon;Lee, Hee-Nam
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.330-335
    • /
    • 2012
  • A Bus Trunk System for Wind Tower is introduced. A marine cable has been widely used in wind tower or other offshore structure. However, as the electric load capacity is getting increased, the large number of cable lines should be used to cover such a huge amount of electric capacities, which makes the installation make quite difficult due to the heavy weight and volume of the present cables. On the other hand, by using a single bus trunk system line, the power capacity amount of 16 number of cable can be delivered with significant compactness. However, unlike flexible cable, the bus trunk is relatively stiff which could arise resonance phenomenon in the operating condition of wind tower, therefore, the vibration characteristics of bus trunk should be investigated and verify its long-term reliability during the life time of the wind tower.

  • PDF

Analysis of the stresses induced by magnetic field and cooling in the CICC type superconducting bus-line (CICC 형태의 초전도 버스 선에서 냉각 및 자기장에 의한 응력 해석)

  • Lee, Ho-Jin;Nam, Hyeon-Il;Kim, Gi-Baek;Hong, Gye-Won
    • Progress in Superconductivity and Cryogenics
    • /
    • v.2 no.2
    • /
    • pp.20-25
    • /
    • 2000
  • A CICC type superconducting bus-line electrically connecting a superconducting magnet to a power supply is cooled down to low temperature under the external magnetic field during operation. The thermal contraction during the cooling may be constrained by the supports which are installed to protect the bus-line from Lorenz magnetic forces. This constrained contraction causes thermal stresses in the bus-line to release thermal contraction. The minimum stress conditions in the bus-line may be optimized by controlling the supporting arrangement considering the thermal contraction and the external field. The analytical method to find optimal supports arrangement was suggested by using the beam theory, and numerical calculation using commercial code was performed to verify the suggested analytical optimization method.

  • PDF

An Improved Adaptive Control Technique for the Voltage Bus Conditioner with the Reduced Capacitive Storage (축소된 캐패시터 스토리지를 갖는 Voltage Bus Conditioner의 향상된 적응제어)

  • La, Jae-Du;Lee, Yong-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.1
    • /
    • pp.13-18
    • /
    • 2011
  • More and all-electric aircraft (AEA) carry many loads with varied functions. In particular, there may be large pulsed loads with short duty ratios which can affect the normal operation of other loads. In this paper, a converter with spilt capacitors and an improved adaptive controller is used as the Voltage Bus Conditioner (VBC) with the reduced capacitive storage to mitigate the voltage transients on the bus. The proposed converter allows the smaller capacitive storage. Also, the proposed controller has the advantage of requiring only one sensor and performing both the functions of mitigating the voltage bus transients and maintaining the level of energy stored. Experimental results are presented which verify the control principles and demonstrate the practicality of the approach.

Current Sensorless Control of the Voltage Bus Conditioner for a DC Power System with Parallel Pulsed Power Loads (병렬 펄스 부하를 갖는 직류 전력시스템을 위한 Voltage Bus Conditioner의 전류 센서 없는 제어)

  • Lee, Byung-Hun;Chang, Han-Sol;La, Jae-Du;Kim, Young-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1617-1624
    • /
    • 2012
  • A DC power system has many loads with varied functions. Also, there may be large pulsed loads with short duty ratios which can affect the normal operation of other loads. In this paper, Voltage Bus Conditioner(VBC) without any current sensors is proposed to damp the bus voltage transients by parallel pulsed loads. The proposed control approach requires only one voltage sensor and carries out both the functions of damping the bus voltage transients and maintaining the level of energy stored. The proposed control technique has been implemented on a TMS320F2812 Digital Signal Processor(DSP). Simulated results by a Matlab Simulink and experimental results are presented which verify the control principles and demonstrate the practicalty of the approach.

Accurate Transmission Loss Allocation Algorithm Based on the Virtual Transaction Strategy: Comparison of Path-integral with Discrete Integral Methods

  • Min, Kyung-Il;Moon, Young-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.4
    • /
    • pp.511-521
    • /
    • 2010
  • This paper presents a new algorithm to determine accurate bus-wise transmission loss allocation utilizing path-integrals dictated by the transaction strategy. For any transaction strategy, the total sum of the allocated transmission losses of all buses is equal to the actual loss given by the AC power-flow calculation considering the distributed slack. In this paper, the bus-wise allocation of the transmission loss is calculated by integrating the differential loss along a path determined by the transaction strategy. The proposed algorithm is also compared with Galiana's method, which is the well-known transmission loss allocation algorithm based on integration. The performance of the proposed algorithm is evaluated by case studies carried out on the WSCC 9-bus, IEEE 14-bus, New England 39-bus, and IEEE 118-bus systems. The simulation results show that the proposed algorithm is fast and accurate with a large step size.

A Study on the Data Bus for the Integration of Avionics Systems (항공전자 시스템 통합을 위한 데이터 버스 연구)

  • Hong, Seung-Beom;Jie, Min-Seok;Kim, Young-In;Hong, Gyo-Young;Cheon, Gi-Jin
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.17 no.3
    • /
    • pp.70-77
    • /
    • 2009
  • We proposed the method of avionics integrated architecture using high-speed fiber optic bus. Typically, data bus of aircraft consists of electronic and optic data transmission method. Avionics systems are difficult to operate the electronic data transmission method for the high speed data processing, synchronization and interconnection between flight control system and flight management system efficiently. In this paper, it is known to look into the problem of data bus and the advanced trend in avionics systems, and propose the appropriate data bus of the advanced avionics systems.

  • PDF

Rollover Analysis and Measurement of a Large-sized Bus (대형 버스의 전복 해석과 측정법)

  • 정태은
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.6
    • /
    • pp.148-154
    • /
    • 1997
  • The safety problems of buses have been arisen due to the increasing of road traffic. Occupant injuries are always possible in the rollover accident and the frontal impact. Thus the structure of bus should have sufficient strength to protect passengers under accidental loads. ECE(Economic Commission for Europe) regulation No.66 prescribes that the superstructure of the vehicle shall be sufficient strength for passengers' surviving and the residual space shall be preserved in the passenger compartment during and after the standard rollover accident situation. Rollover test and simulation on a large-sized bus was completed according to the regulation. The coordinates of the points on the bus were measured by photogrammetry system. The rollover situation was revived by structural crashes simulation software, PAM-CRASH, and it was checked that the structure still complied with the requirements of residual space during rollover situation. The residual space was preserved during rollover, so it was proved that the structure of the investigated bus had much probability of survival in rollover accidents.

  • PDF

Configuration of Actuator and Sensor Interface Bus Network using PLC

  • Luu, Hoang-Minh;Park, Young-San
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.3
    • /
    • pp.318-322
    • /
    • 2014
  • A kind of field bus called Actuator and Sensor interface bus(AS-i) was designed in this paper. The configuration of AS-i network system used Application Specific Integrated Circuit(ASIC) SAP5S chip and PLC S7-200 station, which included CPU 224 and AS-i master module CP 243-2. We also created an example program for PLC S7-200 to control AS-i network. The fire and smoke detection system was made with AS-i network system that was designed. This system had got more advantages than other system such as number of stations, easy installation, wide working area, etc. And designed system can be used as a partner network for higher level field bus networks.

Configuration and Role for Smart Station Considering of the Special mad of Bimodal Tram (바이모달트램용 전용선로를 고려한 스마트 정거장의 구성 및 역할)

  • Lee, Kang-Won;Yoon, Hee-Taek;Mok, Jai-Kyun;Kim, Young-Min;Kim, Tae-Won
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.260-269
    • /
    • 2009
  • A station is the place for the passenger who load the baggage or for bus, taxi, train to stop regularly. For example, bus stop which is installed on many areas for bus as a public transportation provides some space to the passenger who waits for getting on the bus. The bus stop built up recently carries on many kinds of function to make the passenger convenient different from the conventional simple bus stop. Smart station for Bimodal Tram combined with ITS(Intelligent Transportation System) technology has the advantages of both new and conventional stations. This paper has investigated the function and role of newly developed smart station which is able to be adaptive to the rapid variation of road station.

  • PDF