• Title/Summary/Keyword: BPM6

Search Result 120, Processing Time 0.172 seconds

Comparison of rhythmic and non-rhythmic aerobic exercises on depression and balance in the elderly

  • Kwon, Il-Ho;Song, Jun-Young;Kim, Do-Ye;Son, Je-Yeong;Shim, Yu-Jin;Shin, Won-Seob
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.3
    • /
    • pp.146-151
    • /
    • 2017
  • Objective: The purpose of this study was to investigate the effects rhythmic and non-rhythmic aerobic exercises on depression and balance of healthy elderly people. Design: Randomized controled trial. Methods: Nineteen older subjects were randomly divided into 2 groups for rhythmic and non-rhythmic aerobic exercises. Both aerobic exercises consisted of functional movements such as turning in opposite directions, and running in place, the exercise consisted of movements that could activate balance. The rhythmic training group initially used music with 8 beats, and then later progressed to 16 beats. Additionally, we adjusted the pace of the music using songs from 125 beats per minute (bpm) to 160 bpm. Both groups were exercised for 50 minutes a day, twice a week, for a total of 8 weeks. We measured the condition of the patients before the intervention, and after 8 weeks of intervention. The Beck depression inventory (BDI) was used to measure the degree of depression. The Berg balance scale (BBS) was used to measure static and dynamic balance ability. We measured the subject's subjective balance confidence using the fall efficacy scale (FES). Results: Both groups showed significant improvement in BDI, BBS, and FES (p<0.05). The rhythmic aerobic exercise group showed a significant improvement only in the BBS change values compared to the non-rhythmic group (p<0.05). Conclusions: According to this study, both rhythmic and non-rhythmic aerobic exercises resulted in significant improvement in the degree of depression and balance ability of the elderly. The rhythmic aerobic exercise was more effective for dynamic balance ability.

Engineering Education by Elliptical Trainers(ET) - Cardiorespiratory Responses by the Mean Free Path (Elliptical Trainers(ET)를 이용한 공학교육 - 평균자유거리에 의한 심폐기능의 반응)

  • Hwang, Un Hak
    • The Journal of Korean Institute for Practical Engineering Education
    • /
    • v.3 no.2
    • /
    • pp.53-62
    • /
    • 2011
  • The elliptical trainers(ET) can be a good tool for educating engineers by analyzing physical responses in terms of Respiratory Exchange Ratio (RER, epm) and Heart Rate (HR, bpm). For the various energy expenditure, exercise speed, and weight loss both RER and HR are studied in order to study the blood circulations based on the health training cardiorespiratory. As the results, (1) RER increases gradually as the energy expenditure, however, HR increases gradually up to a critical value and then increases rapidly. The critical value of the energy expenditure in our studies was 275 Cal. (2) RER increases gradually as the ET speed increases, however, HR increases gradually up to a critical value and then increases rapidly. The critical value of the ET speed in our studies was about 6.7km/h. (3) RER increases gradually as the weight loss increases (or, the metabolic cost increases), however, HR is almost nothing to do with the increase of the weight loss.

  • PDF

The Effects of Beta-blocker and Aerobic Exercise on Heart Rate Recovery and Exercise Capacity after Maximal Exercise in Acute Coronary Syndrome Patients

  • Cha, Kyung-Hwa;Oh, Jae-Keun;Kim, Young-Joo
    • Biomedical Science Letters
    • /
    • v.19 no.1
    • /
    • pp.70-78
    • /
    • 2013
  • This study was conducted to identify the effects of intake of beta-blocker and aerobic exercise on heart rate recovery (HRR) and exercise capacity after maximal exercise in acute coronary syndrome patients (ACS). Subjects were divided into 4 groups; Beta-blocker-Exercise group (n=10), Beta-blocker group (n=10), Exercise group (n=10), Control group (n=10). Symptom-limited grade exercise test were conducted on subjects pre- and post- 6 week study, to measure maximal heart rate, heart rate at 1 minute and 2 minutes at the recovery stage, maximal oxygen uptake and maximal exercise time. Study resulted in significant improvements in heart rate recovery for BB-Ex group ($17.40{\pm}5.58$ bpm to $26.10{\pm}6.66$ bpm), maximal oxygen uptake for BB-Ex group ($30.46{\pm}8.63$ to $36.33{\pm}8.10$) and Ex group ($29.04{\pm}4.93$ to $34.31{\pm}5.19$), and total exercise time for BB-Ex group ($906.30{\pm}158.57$ to $1018.50{\pm}151.21$), BB group ($805.70{\pm}182.94$ to $897.50{\pm}160.16$) and Ex group ($870.00{\pm}145.63$ to $961.90{\pm}107.29$). Therefore it showed the biggest improvement for heart rate recovery and exercise capacity in acute coronary syndrome patients when both Beta-blocker and aerobic exercise were in effect.

A Study on the Fabrication of Integrated Optical Electric-Field Sensor and Performance utilizing Asymmetric $Ti:LiNbO_3$ Mach-Zehnder Interferometer (비대칭 $Ti:LiNbO_3$ Mach-Zehnder 간섭기를 이용한 집적광학 전계센서 제작 및 성능에 관한 연구)

  • Ha, Jeongho;Jung, Hongsik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.10
    • /
    • pp.128-134
    • /
    • 2012
  • The performance evaluation and fabrication of integrated-optic electric-field sensor utilizing $Ti:LiNbO_3$ asymmetric Mach-Zehnder intensity modulator with a push-pull lumped electrode and a plate-type probe antenna to measure an electric field strength is described. The modulator has a small device size of $46{\times}7{\times}1\;mm$ and operates at a wavelength $1.3{\mu}m$. The devices are simulated based on the BPM software and fabricated utilizing Ti-diffused $LiNbO_3$ channel optical waveguides. The minimum detectable electric field is 1.02 V/m and 6.91 V/m, corresponding to a dynamic range of ~35 dB and ~10 dB at the frequencies of 500 KHz and 5 MHz, respectively.

Design and Analysis of Mach-Zehnder-Interferometer-Based Silica Planar Lightwave Circuit Triplexer (마하젠더 간섭계로 구성된 실리카 평판 광 도파회로 트라이플렉서의 설계 및 분석)

  • Lee, Tae-Hyung;Lee, Dong-Hyun;Chung, Young-Chul
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.6
    • /
    • pp.447-451
    • /
    • 2007
  • A triplexer based on a silica planar lightwave circuit Mach-Zehnder nterferometer(MZI) is proposed and its characteristics are analyzed through simulations. To separate 1310 nm band and $1480{\sim}1560nm$ band properly, the path length difference of an MZI is set to be the multiple and half of the wavelength 1310 nm and the balance of the directional coupler is optimized in the $1480{\sim}1560nm$ band. The same MZI is additionally cascaded to provide good crosstalk characteristics. The 1490 nm band and 1550 nm band are further separated using additional two stage MZI's. A three-dimensional BPM and transfer matrix method analysis predicts the low crosstalk characteristics and the fabrication-error-tolerance of the proposed triplexer.

A Study on the Integrated-Optical Electric-Field Sensor utilizing Ti:LiNbO3 Y-fed Balanced-Bridge Mach-Zehnder Interferometric Modulators (Ti:LiNbO3 Y-fed Balanced-Bridge 마하젠더 간섭 광변조기를 이용한 집적광학 전계센서에 관한 연구)

  • Jung, Hongsik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.1
    • /
    • pp.29-35
    • /
    • 2016
  • We have demonstrated a $Ti:LiNbO_3$ electro-optic electric-field sensors utilizing a $1{\times}2$ Y-fed balanced-bridge Mach-Zehnder interferometric (YBB-MZI) modulator which uses a 3-dB directional coupler at the output and dipole patch antenna. The operation and design were proved by the BPM simulation. A dc switching voltage of ~16.6 V and an extinction ratio of ~14.7 dB are observed at a wavelength of $1.3{\mu}m$. For a 20 dBm rf power, the minimum detectable electric-fields are ~1.12 V/m and ~3.3 V/m corresponding to a dynamic range of about ~22 dB and ~18 dB at frequencies 10 MHz and 50 MHz, respectively. The sensors exhibit almost linear response for the applied electric-field intensity from 0.29 V/m to 29.8 V/m.

A study of relevant model of information management system based on business process for embodying BPM on construction company (건설기업 BPM 구현을 위한 업무 프로세스 기반의 업무지원 시스템 연계모델에 관한 연구 -공정관리 업무 프로세스를 중심으로-)

  • Lee, Jung-Woo;Song, Young-Woong;Choi, Yoon-Ki
    • Korean Journal of Construction Engineering and Management
    • /
    • v.10 no.6
    • /
    • pp.13-27
    • /
    • 2009
  • Construction companies are trying to apply process management to their business to improve efficiency in business circumstance of high competition and globalization. Since 1990s, construction firms adopted process management to improve internal and external business structure based on process. It however has a few improvement functions. In addition, business support systems for business process efficiency improvement were developed, but separation between business process and IT system occurred because it focused on function-based individual construction and data input/output. To solve this problem, this study proposed business process and IT integration model for supporting user to use business information and system based on visualized business process and improving use of previous business support system. Business efficiency is expected to be improved with this model which based on integration required business condition(stakeholder, business data, functions of business supporting system). This study developved process model, architecture, and BPA of whole construction management business. According to BPA, it analyzed business process stakeholder, detail activities, and input-output data. And also it examined 12 main business supporting system of Korean construction firms. Based on analyzed data, this study developed business process supporting integration model based on business process through PDCA and CRUD analysis.

Study on Vertical Position Reading Noise from Beam Position Monitor in Pohang Light Source Storage Ring Vacuum Chamber (포항광가속기 저장링 진공용기의 빔위치측정기의 위치 측정 오류에 대한 연구)

  • Joo, Young-Do;Kim, Chang-Bum;Hwang, Il-Moon;Park, Chong-Do
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • A sudden step change is observed in the vertical position readings from beam position monitors (BPMs) mounted at the several sector vacuum chambers of Pohang Light Source. To study the source of this sudden step change, we measured the RF transmission scattering matrix (S21) through the pickup electrodes of BPMs mounted at the both ends of the sector vacuum chamber. The measured $S_{21}$ graph of the sector vacuum chambers suffering sudden step change has a peak in the BPM operation frequency bandwidth. Otherwise that of the other sector vacuum chambers doesn't have a peak. It is shown by the numerical simulation that the peak found in the BPM operation frequency bandwidth corresponds to the longitudinal harmonic of transverse electric resonance mode.

Bradycardia after Dobutamine Administration in a Dog (Dobutamine 투여 후 발생한 개의 서맥 1례)

  • Jang, Min;Son, Won-Gyun;Hwang, Hyeshin;Jo, Sang-Min;Yi, Kang-Jae;Yoon, Junghee;Lee, Inhyung
    • Journal of Veterinary Clinics
    • /
    • v.31 no.4
    • /
    • pp.350-353
    • /
    • 2014
  • A 13-year-old, castrated male, Shih Tzu dog with a history of acute ataxia was referred to veterinary medical teaching hospital and anesthetized for diagnostic magnetic resonance imaging of cervical intervertebral disk disease. After preanesthetic evaluation including physical examination, blood chemistry, radiography and ultrasound, the patient was premedicated with intravenous butorphanol (0.2 mg/kg). Anesthesia was induced by intravenous propofol (6 mg/kg) and maintained with isoflurane at 1.2 minimal alveolar concentrations. Because the mean arterial pressure (MAP) decreased from 70 to 58 mmHg at 70 minutes after induction, dobutamine was administered by constant rate infusion ($5{\mu}g/kg/min$) to treat hypotension. However MAP did not increase, and heart rate rapidly decreased from 100 to 55 beats per minute (bpm). To treat bradycardia, intravenous glycopyrrolate ($5{\mu}g/kg$) was administered, and heart rate increased to 165 bpm. After extubation of endotracheal tube, the patient showed normal recovery without any problems related to cardiovascular system. Unexpected dobutamine-induced bradycardia was considered as Bezold-Jarisch reflex. It is recommended that clinicians know and prepare the possibility of bradycardia during dobutamine therapy under general anesthesia.

GAM: A Criticality Prediction Model for Large Telecommunication Systems (GAM: 대형 통신 시스템을 위한 위험도 예측 모델)

  • Hong, Euy-Seok
    • The Journal of Korean Association of Computer Education
    • /
    • v.6 no.2
    • /
    • pp.33-40
    • /
    • 2003
  • Criticality prediction models that determine whether a design entity is fault-prone or non fault-prone play an important role in reducing system development costs because the problems in early phases largely affect the quality of the late products. Real-time systems such as telecommunication systems are so large that criticality prediction is mere important in real-time system design. The current models are based on the technique such as discriminant analysis, neural net and classification trees. These models have some problems with analyzing causes of the prediction results and low extendability. This paper builds a new prediction model, GAM, based on Genetic Algorithm. GAM is different from other models because it produces a criticality function. So GAM can be used for comparison between entities by criticality. GAM is implemented and compared with a well-known prediction model, BackPropagation neural network Model(BPM), considering Internal characteristics and accuracy of prediction.

  • PDF