• Title/Summary/Keyword: BOD reduction

Search Result 189, Processing Time 0.024 seconds

Assessment of Non-Point Source Pollutant Loads and Priority Management Areas using an HSPF Model in Sejong City, South Korea

  • Lim, Dohun;Lee, Yoonjin
    • Journal of Environmental Science International
    • /
    • v.26 no.8
    • /
    • pp.881-891
    • /
    • 2017
  • In this study, the discharge loads of non-point pollution sources were analyzed using a Hydrologic Simulation Program-Fortran (HSPF) model for 46 sub-watersheds in order to guide the management plan for water and streams passing through the city. The results using HSPF showed good applicability in comparison to point measurements, which were based on BOD, TP, and TN. The mean value of the BOD loads was $4.08kg/km^2$ per day, and the highest level of BOD was $17.75kg/km^2$ per day at Namri. Three potential areas of high priority for the installment of constructed wetlands were selected in order to reduce non-point pollution sources based on BOD loads and on environmental and economic conditions. The results for these scenarios indicated a maximum rate of reduction in BOD of 39.12% within the proposed constructed wetlands.

Removal of Toxicity from Kraft Pulp Mill Effluents by Activated Sludge Process (활성슬러지 공정에 의한 Kraft 펄프 폐수의 독성 제거)

  • Kim, Yeong-Kwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.8 no.3
    • /
    • pp.9-18
    • /
    • 1994
  • Activated sludge pilot plant testing was conducted to determine the ability of a well-designed activated sludge treatment system to remove chromic toxicity from the bleached kraft pulp mill effluent. Removals of conventional(BOD and SS) and nonconventional(resin and fatty acids, color, AOX) pollutants were estimated. The pilot plant was operated at steady state for about 10 weeks at an F/M of 0.28 and a sludge age of 8.4 days. The average MLSS concentration was 4,309mg/l, of which volatile fraction was 57%. During the operation period, the BOD removal reaction rate(k) was determined to be 8.2/day at $30^{\circ}C$. The BOD removal was 84 percent, which was 3 to 6 percent lower than expected for full-scale treatment. The chronic toxicity of the activated sludge effluent was tested by employing both Dinnel and the BML protocols. It was found that the pilot plant could achieve in excess of 90 percent reduction in chronic echinoderm toxicity. The data show slight reduction of color and AOX across the activated sludge system. The pilot system, however, demonstrated on excellent removal of resin and fatty acids.

  • PDF

Estimation of Livestock Pollutant Sources Reduction Effect on Water Quality in Hapcheon Dam Watershed Using HSPF Model (HSPF 모형을 이용한 축산계 비점오염 저감에 따른 합천댐 유역 수질 영향 분석)

  • Cho, Hyun Kyung;Kim, Sang Min
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.2
    • /
    • pp.98-108
    • /
    • 2020
  • The purpose of this study was to evaluate water quality in Hapcheon dam via using the Hydrological Simulation Program-Fortran (HSPF) model and applied livestock reduction scenarios. Hapcheon dam watershed input data for the HSPF model were established using the stream, land use, digital elevation map and meteorological data and others. The HSPF model was calibrated and validated using the observed water quality data from 2000 to 2016. For water quality simulation, we calculated the generated and discharge loads of the population, livestock, industry and land use following the guideline provided by the Ministry of Environment. The pollutant data were obtained from National Institute of Environmental Research (NIER). The monthly discharge load were estimated by applying the delivery rate. The calibration and validation results showed that the annual mean BOD had a difference of 0.22 mg/L and an error of ±13 %, T-N had a difference of 0.66 mg/L and an error of ±16 % and T-P had a difference of 0.027 mg/L and an error of ±13 %. In order to evaluate the nonpoint pollutants management effects, we applied livestock reduction scenarios because livestock consists of the largest portion of pollutants. As a result of the 20 % of livestock reduction, BOD, T-N and T-P decreased by 3 %, 1 % and 3 %, respectively. When 40 % of livestock reduction was applied, BOD, T-N and T-P decreased by 5 %, 3 % and 4 %, respectively. Based on the results of this study, effective pollutant management methods can be applied to improve the water quality and achieve the target water quality of Hapcheon dam watershed.

Design of Structural BMPs for Low Impact Development (LID) Application and Modelling Its Effect on Reduction of Runoff and Nonpoint Source Pollution: Application of LIDMOD2 (저영향개발(LID)적용을 위한 구조적 BMPs의 유출량 및 비점오염저감 효과모의: LIDMOD2 적용)

  • Kim, Jung Jin;Kim, Tae-Dong;Choi, Donghyuk;Jeon, Ji-Hong
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.5
    • /
    • pp.580-586
    • /
    • 2011
  • Low impact development (LID) technique is recently proposed as new concept to reduce surface runoff and pollutant loading with various best management practices (BMPs). In this study, LIDMOD2, which is one of the model to evaluate LID, was applied at Mohyeon developing area to evaluate the redcution of annual runoff and pollution loading, cost-reduction efficient by LID with design of structural BMPs including bioretention, wet pond, and wetland. As a simulation results, the bioretention had the highest reduction efficiency for runoff (41.43%), and 22% for T-N and 22% for BOD. Wet pont had the highest reduction efficiency for T-P as showing 25% of reduction rate. As a results of cost-reduction efficient, wet pont represented the highest cost-effective for T-N and BOD with showing 0.43 T-P kg/million won and 17.37 BOD kg/million won, respectively, and bioretention represented the highest cost-effective for T-P with showing 2.52 T-P kg/million won. LID technology could reduce effectively surface runoff and nonpoint source pollution and construct sustainable development. LIDMOD2 could be suggested as useful tool to evaluate and design LID.

Analysis of Methane from Screened Soil of Closed Landfill and Application of Landfarming for the Reduction of the Methane (사용종료 매립지 선별토양의 메탄 발생 분석 및 토양경작기술 적용 효과 연구)

  • Kim, Kyung;Yang, Jae-Kyu;Chang, Yoon-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.15 no.5
    • /
    • pp.40-45
    • /
    • 2010
  • In this study, methane production by reuse of screened soil of landfill was estimated and the effect of application of landfarming for the reduction of methane was investigated. The study soil sampled from S closed landfill contains VS 9.8~12.8% and its BOD/COD is 0.31~0.33 which is more than three times over 0.1, the BOD/COD stabilization criteria of Ministry of Environment. The effective remediation technology for the reduction of organics of soil, landfarming was applied to the screened soil for 60 days. VS and TPH removal showed 5.2~8.3% and 67~74% respectively, and the reduction of VS until 30 day charged 70% of the total reduction. BMP test showed 27.77~30.46 mL $CH_4$/g VS and total methane production from total screened soil for remediation is expected about 260.4 $CH_4$ ton. Expected amount of methane production of the screened soil by landfarming application is 12.9 $CH_4$ ton, which shows 95% gas reduction effect and landfarming is effective for the reduction of methane production from screened soil of landfill.

Cleaner Production System in Dyeing & Finishing Its Approaching Mehods (염색가공분야에서 청정생산활동 접금방법)

  • Lee, Hae-Jung;Nam, Chang-Woo;Park, Young-Hwan
    • Clean Technology
    • /
    • v.9 no.2
    • /
    • pp.87-100
    • /
    • 2003
  • The aim of study was to suggest a methodology for applying cleaner production technology in dyeing & finishing process of textile materials. To accomplish cleaner production, we performed consulting activity in dyeing factory, which composed of following different procedures. First, we organized consulting team with specialists for dyeing, energy and chemicals, and visited dyeing companies for the purpose of doing basic investigation such as analysis of process, chemicals & effluents, condition of equipment and process flow of products. Environmental aspect of raw materials (dyestuff, chemicals) was assessed by TOC, COD, BOD, and effluent of that was assessed by TOC, COD, BOD, TDS and pH. Second, We find out the problems in dyeing&finishing process from the view point of dyeing process, energy, raw materials and process management by utilizing MB (material balance), LCA(Life Cycle Assessment), EB(Energy Balance). Third, we generated the solutions to achieve optimal process condition by brain storming method, and then implemented the solutions to each process. Finally, we determined their effectiveness after considering the results of repeating trials for the solutions. Cleaner production could be achieved by keeping optimal process conditions, equipment modification, improved production management, and on-site reuse or recycling.

  • PDF

The Appropriate Treatment and Reuse Ability Assessment of Pigment Wastewater by Physical, Chemical, and Biological Process (물리, 화학 및 생물학적 방법에 의한 안료폐수의 적정처리 및 재이용 가능성 평가)

  • 정종식;옥치상
    • Journal of Environmental Science International
    • /
    • v.7 no.1
    • /
    • pp.81-88
    • /
    • 1998
  • This study was conducted to assess the characteristics of plgment wastewater and the removal rates of appropriate treatment by physical, chemical and biological Process, and the possibility of reuse for effluent. Based on the results, the wastewater qualities of pigment were pH 5.1$\pm$3.4, temperature 43.0$\pm$ 15.$0^{\circ}C$, BOD 1,431.4$\pm$589.6mg/l, COD 2,282.8$\pm$466.5mg/l, turbidity 1,340$\pm$820NTU, color 243.0$\pm$147.0unit, Pb 36.5$\pm$9.5mg/l and $Cr^+6$ 10.3$\pm$ 1.3mg/l, respectively. The removal rates of adsorption by activated carbon and filter process were BOD 40.6% , COD 57.0% , turbidity 89.6%, color 87.2%, Pb 86.0% and $Cr^+6$ 10.6%, respectively. And the removal rates of reduction, neutralization, coagulation and aP floatation process were BOD 18.2%, COD 24.3%, turbidity 74.3%, color 56.7%, Pb 68.6% and $Cr^+6$ 97.8%, respectively. The removal rates of activated sludge process were BOD 95.9%, COD 86.0%, turbidity 27.8%, color 25. 2%. Pb 26.9% and $Cr^+6$ 50.0% , respectively. The total removal rates of treatment by physical, chemical and biological process were BOD 98.0% , COD 95.4%, turbidity 98.1%, color 95.8%, Pb 97.0% and $Cr^+6$ 99.0%, respectively. According to the test results for possibility of reuse with coagulation-adsorption by activated carbon process of effluent, COD was higher than that of raw water and others were similar to that of raw water thus, it Is considered to be reused.

  • PDF

Analysis of Infiltration Trench Facility for Runoff Reduction Effect (침투트렌치 시설의 유출저감 효과 분석)

  • Yeon, Jong Sang;Jang, Young Su;Shin, Hyun Suk;Kim, Eung Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5813-5819
    • /
    • 2014
  • LID planning and application has been actively developed to reduce the runoff volume at increased impervious areas due to rapid urbanization. In this study, a performance and applicability evaluation was performed in an infiltration trench using the SWMM model, based on the experimental conditions for infiltration trenches. The infiltration trench application area was applied to 5~15% of the drainage area. The SWMM results of discharge and the BOD reduction efficiency were analyzed at a peak discharge of 45.7~61.9%, total discharge of 47.2~62.3%, and BOD load of 52.3~55.3. The discharge and BOD was estimated to be 12~24% higher and 37~38% smaller than the experimental results. This study can help in the application and performance evaluation of infiltration trenches.

Sensitivity of BOD Sensor with Heavy Metal Tolerant Serratia marcescens LSY4 (Serratia marcescens LSY4 중금속 내성주를 이용한 BOD센서의 감응도)

  • Kim Mal-Nam;Lee Sun-Young
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.3
    • /
    • pp.394-399
    • /
    • 2004
  • A BOD sensor was prepared with S. marcescens LSY4 and was applied for measurement of BOD values of a solution containing the standard organic pollutants. The sensor sensitivity was nearly independent of the culture time in the range of 9-16 hours. It was also affected little by the cell mass in the range of 0.22-0.75 mg $cm^{-2}$. A cyclic change in the solution pH in the range of 4-9 was accompanied by a reversible variation in the sensor sensitivity. However, the reversibility was lost when the solution pH became more acidic or more basic. Heavy metal ions lowered the sensor sensitivity, which took place more precipitously in the presence of $Cu^{2+}$ and $Ag^+$ rather than in the presence of $Zn^{2+}$ and $Cd^{2+}$. The reduction of the sensor sensitivity was significantly attenuated by loading heavy metal ion tolerance induced strain. The $Cu^{2+}$tolerance induced strain was more efficient for the attenuation than $Zn^{2+}$ and $Cd^{2+}$ tolerance induced strain.

A Plot Scale Experiment to Analysis the NPS Reduction by Silt Fence and Vegetated Ridge for Non-Irrigated Cropland (실트펜스와 식생밭두렁 적용을 통한 밭 비점오염 저감효과 분석을 위한 포장실험 연구)

  • Kim, Sung-Jae;Park, Tae-Yang;Kim, Sung-Min;Jang, Jeong-Ryeol;Kim, Sang-Min
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.4
    • /
    • pp.19-27
    • /
    • 2012
  • The objective of this study was to test the pollutant reduction effect by the silt fence and vegetated ridge through field monitoring. The experiment plots were established with two replication and three treatments. Each plot was designed with 5 m width, 22 m length, and 3 % slope. Flumes with the floating type stage gages were installed at the outlet of each plot to monitor the runoff. For a rainfall monitoring, tipping bucket rain gage was installed within the experiment site. Cultivated crops were spring daikon and autumn chinese cabbage. Analysis of variance (ANOVA) indicated that the water quality concentration from three experiment plots were not significantly different in 5 % of significant level. The monitoring results showed that the average pollution loads reduced by silt fence compared to control were SS 75.33 %, TN 40.87 %, TP 56.58 %, BOD 52.12 %, COD 36.07 %, TOC 34.99 %; by vegetated ridge compard to control were SS 65.27 %, TN 81.80 %, TP 54.26 %, BOD 67.09 %, COD 46.55 %, TOC 43.30 %. Analysis of Spearman's rank correlation coefficient showed that BOD-SS and SS-Turbidity were highly related at the silt fence and vegetated ridge plots. In all plots, SS-Turbidity and TP-TN relations were relatively high. The monitoring results showed that the silt fence and vegetated ridge were effect method to reduce the pollutant loads from the field runoff. Long-term monitoring is required to obtain more quantitative reduction effect for diverse crops and to increase the reliability of results.