• 제목/요약/키워드: BIPV- building integrated photovoltaic

검색결과 128건 처리시간 0.023초

울산지역의 태양광에너지의 활용방안 (Application Strategies of Photovoltaic Energy in Ulsan)

  • 이관호;심광열
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.320-323
    • /
    • 2009
  • Weather data is an important variable for the estimation value of the program for evaluating energy performance. The difference in data value of major weather elements used in weather data (temperature, insolation amount) were compared and analyzed. It was found that temperature showed similar values but insolation amount took different values. Especially in Ulsan, since the Meteorological Association does not measure insolation amount. To optimize the incident solar radiation, the solar azimuth angles are needed for solar photovoltaic systems. Test results shows that the $60^{\circ}$installation angel higher efficient than the $30^{\circ}$ installation angel in winter.

  • PDF

실증 목업의 구축 및 데이터의 통계적 분석을 통한 건물일체형 태양광 발전시스템의 전력발전 향상 설계 (BIPV System Design to Enhance Electric Power Generation by Building up a Demonstration Mock-up and Analyzing Statistical Data)

  • 이승준;이재천
    • 한국산학기술학회논문지
    • /
    • 제19권6호
    • /
    • pp.587-599
    • /
    • 2018
  • 건물일체형 태양광 발전(BIPV) 시스템은 태양광 모듈을 건축부자재와 결합하여 설치함으로써 주거, 보관, 경제성 요소 등의 건축물 기능을 만족시키면서도 태양광 발전기능을 동시에 수행하기 위한 통합시스템이다. 시스템 통합으로 인해 얻게 되는 장점이 있지만, 태양광 발전기능을 극대화할 수 있는 설계가 필요하다. 선행연구로서 컴퓨터 시뮬레이션과 실증으로 여러 가지 설계요소들이 발전성능에 미치는 영향분석 결과들이 발표되었지만, 발전성능 분석의 부정확성, 설계요소 간의 관계분석의 미흡, 제한된 실증 범위 등이 문제점으로 남아 있다. 이 문제를 해결하기 위해 본 논문에서는 먼저 발전성능을 실증으로 평가할 수 있도록 목업 시험동을 설계 및 구축하고, 실증시스템 운영에서 획득한 데이터의 통계분석을 수행한 결과를 바탕으로 설계 방안을 연구한다. 구체적으로 주요 설계요소로서 모듈의 종류(c-Si, a-Si), 설치각도($90^{\circ}$, $75^{\circ}$, $30^{\circ}$, $15^{\circ}$, $3^{\circ}$), 설치방향(서향, 남서향, 남향, 남동향, 동향) 등을 선택하였다. 선택된 설계요소들의 발전성능에 대한 영향을 분석하기 위해, 1년간의 운영 데이터를 획득하여 통계적인 기법으로 데이터의 유효성을 검증하였으며, 또한 다양한 설계요소들 사이의 관계분석을 통하여 발전성능이 최적화되는 설계안을 제시하였다. 이 연구결과는 향후 BIPV 시스템의 적용성 여부에 대해 판단할 때, 그리고 BIPV 시스템을 설계할 때 설계요소들의 최적 선택에 대한 자료가 될 수 있다.

건물일체형 투명 PV복층창의 설치조건에 따른 단위출력당 발전특성 분석연구 (A Study on the Power Performance Measurement of Transparent Thin-film PV Windows of BIPV Depending on the Inclined Angle)

  • 안영섭;송종화;김석기;이성진;윤종호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.55-60
    • /
    • 2008
  • This study is on the analysis of power output of transparent thin-film PV windows which are integrated into the building envelope instead of traditional windows. 3 installation angles of vertical, horizontal and $30^{\circ}C$ inclination are investigated. To measure power output of PV windows, full scale mock-up house was designed and constructed. The power performance of PV window system was analyzed for horizontal angle, declination angle and vertical angle according to incline angle. Monitoring data are gathered from November 2006 to August 2007 and statistical analysis is performed to analysis a characteristics of power performance of transparent PV windows. Results show that annual power output of PV window with horizontal angle is 844.4kWh/kWp/year, declination angle 1,060kWh/kWp/year and vertical angle 431.6 kWh/kWp/year.

  • PDF

스팬드럴용 투광형 결정계 BIPV창호의 후면단열 조건에 따른 연간 온도 및 발전성능 분석 연구 (Annual Base Performance Evaluation on Cell Temperature and Power Generation of c-Si Transparent Spandrel BIPV Module depending on the Backside Insulation Level)

  • 윤종호;오명환;강기환;이재범
    • 한국태양에너지학회 논문집
    • /
    • 제32권4호
    • /
    • pp.24-33
    • /
    • 2012
  • Recently, finishing materials at spandrel area, a part of curtain-wall system, are gradually forced to improve thermal insulation performance in order to enhance the building energy efficiency. Also, Building Integrated Photovoltaics(BIPV) systems have been installed in the exterior side of the spandrel area, which is generally composed of windows. Those BIPVs aim to achieve high building energy efficiency and supply the electricity to building. However, if transparent BIPV module is combined with high insulated spandrel, it would reduce the PV efficiency for two major reasons. First, temperature in the air space, located between window layer and finishing layer of the spandrel area, can significantly increase by solar heat gain, because the space has a few air density relative to other spaces in building. Secondly, PV has a characteristics of decreased Voltage(Voc and Vmp) with the increased temperature on the PV cell. For these reasons, this research analyzed a direct interrelation between PV Cell temperature and electricity generation performance under different insulation conditions in the spandrel area. The different insulation conditions under consideration are 1) high insulated spandrel(HIS) 2) low insulated spandrel(LIS) 3) PV stand alone on the ground(SAG). As a result, in case of 1) HIS, PV temperature was increased and thus electricity generation efficiency was decreased more than other cases. To be specific, each cases' maximum temperature indicated that 1) HIS is $83.8^{\circ}C$, 2) LIS is $74.2^{\circ}C$, and 3) SAG is $66.3^{\circ}C$. Also, each cases yield electricity generation like that 1) HIS is 913.3kWh/kWp, 2) LIS is 942.8kWh/kWp, and 3) SAG is 981.3kWh/kWp. These result showed that it is needed for us to seek to the way how the PV Cell temperature would be decreased.

수직형 태양광발전모듈의 계절별 일사획득 및 온도변화에 따른 출력특성 변화에 관한 연구 (Study on variation of electrical characteristics of vertical PV module according to the change of irradiance and temperature)

  • 박경은;강기환;김현일;유권종;김준태
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.57-62
    • /
    • 2008
  • Building Integrated PV(BIPV) is one of the best fascinating PV application technologies. To apply PV module in building, various factors should be reflected such as installation position, shading, temperature, and so on. Especially the installation condition should be considered, for the generation performance of PV module is changed or the generation loss is appeared according to installation position, method, and etc. This study investigates variation of electrical characteristics of a PV module according to the change of irradiance and temperature. From this experimental study, we confirmed that the irradiance, the temperature variation and the generation performance of a PV module were appeared differently according seasonal variation. Actually the PV module installed in building facade showed high-generation performance in winter.

  • PDF

박막 BIPV창의 온도변화와 발전성능 상관관계에 관한 실측연구 (An Experimental Study on Relationship Between Temperature Change and Generation Performance of a-Si BIPV Window System)

  • 김빛나;윤종호;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제32권spc3호
    • /
    • pp.179-184
    • /
    • 2012
  • This research on building Integrated Photovoltaic System replacing windows and doors with amorphous silicon thin film PV windows and doors installing same exact mount on Mock-up. The windows and doors should be installed in different angle and bearing so that we can analyse the amount of electricity from them. The objective of the research is to evaluate and investigate the relationship between factors(intensity of solar radiation, PV window surface temperature, incidence angle, and sky conditions) that affects performance of PV window and performance. The range and method of this research is to establish monitoring system and analysis the data from the monitoring system to evaluate the performance of PV windows that have thin film of solar battery. We should evaluate the insolation according to the position of PV window, output, and surface temperature according to months and seasons so that we can figure out the relationship between these. And we should investigate the relationship between performance and efficiency according to incidence angle and sky condition so that we can figure out the correlation between factors and performance.

옥상녹화시스템의 기온조절효과와 태양광발전효율간의 상호연관성 규명을 위한 전산해석연구 (A Study on Computer Simulation to Investigate Correlations between Temperature Controlling Effect of Green Roof System and the Photovoltaic Power Generation Efficiency)

  • 김태한;박성은
    • 한국태양에너지학회 논문집
    • /
    • 제33권4호
    • /
    • pp.70-79
    • /
    • 2013
  • These day cities experience serious climatic changes due to environmental load caused by disturbance in the circulation systems of water resources and energy. As technological improvement to respond to various climatic changes and disasters are also requested in the field of construction, inter-disciplinary studies linked to the establishment of sustainable environmental control and energy systems is required in a consilient perspective. This study aims to infer correlations in the impact of environmental changes caused by rooftop greening system on the photovoltaic power generation efficiency through computer simulation in an integrated perspective. By doing so, it seeks to provide basic study for developing a photovoltaic system integrated with building revegetation that is sustainable in environmental and resource aspects. A simulation showed that, in the case of sunshine hours in June, the green surface indicated temperature lowering effects of $9.19^{\circ}C$ on average compared to the non-green surface and temperature was $9.81^{\circ}C$ lower. Due to such greening effects, at the highest sunlight timepoint in June, Pmpp improved 119W and heat loss rate dropped 7.8%.

자연채광용 박막 투광형 BIPV 창호의 발전특성 분석 연구 (Performance characteristics of building-integrated transparent amorphous silicon PV system for a daylighting application)

  • 윤종호;김석기;송종화;이성진
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.280-283
    • /
    • 2007
  • The first grid-connected, building-integrated transparent amorphous silicon photovoltaic installation has been operated since October 2004 in Yongin, Korea. The 2.2kWp transparent PV system was applied to the facade of entrance hall in newly constructed KOLON E&C R&D building. The PV module is a nominal 0.98m ${\times}$ 0.95m, 10% transparent, laminated, amorphous(a-Si) thin-film device rated at 44 Wp per module. To demonstrate the architectural features of thin film PV technologies for daylighting application, transparent PV modules are attached to the building envelope with the form of single glazed window and special point glazing(SPG) frames. Besides power generation, the 10% transmittance of a-Si PV module provides very smooth natural daylight to the entrance hall without any special shading devices for whole year. The installation is fully instrumented and is continuously monitored in order to allow the performance assessment of amorphous silicon PV operating at the prevailing conditions. This paper presents measured power performance data from the first 12 months of operation. For the first year, annual average system specific yield was just 486.4kWh/kWp/year which is almost half of typical amorphous silicon PV output under the best angle and orientation. It should be caused by building orientation and self-shading of adjacent mass. Besides annual power output, various statistical analysis was performed to identify the characteristics of transparent thin film PV system.

  • PDF

태양광 모듈의 투과특성과 효율과의 연관성에 대한 연구 (Study on relation of transmittance characteristics and efficiency for Photovoltaic Module)

  • 정인성;정은석;김정근;이범수;김종일;김철주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.453-453
    • /
    • 2009
  • Wafer 태양전지와 Back sheet 및 기타 소재를 사용하는 기존의 Photovoltaic Module은 투과성이 존재하지 않으므로 본 논문에서는 태양전지 모듈의 투과특성을 발휘할 수 있는 Glass to Glass (GtG) Type의 Photovoltaic module에 대해 그 투과 특성 및 효율과의 관계를 분석하였다. 먼저 Module용 소재 중 Poly vinyl butyral (PVB) 및 Ethylene vinyl acetate(EVA) sheet의 Transmittance와 Haze 특성을 분석하였다. GtG 타입의 Photovoltaic Module은 약 90%정도의 투과율을 갖는 강화유리 및 Haze가 없는 PVB sheet를 사용하여 1m $\times$ 1m 크기로 제작하였다. GtG 타입으로 제조한 모둘 중 Cell 16EA를 사용한 모듈은 Cell 25EA를 사용한 모듈에 비해서 36% 투과율이 증가하였으나 효율 면에서 38%감소하였다. 최종적으로 GtG 타입 Module의 효율과 투과율에 관련된 식을 각각 정립하였다.

  • PDF

TRNSYS를 이용한 지역별 고정형 태양광모듈 배치안 검토 (A Study on the Optimum Selection of Placing Photovoltaic Module In the Metropolitan City Using a TRNSYS)

  • 박성현;서장후
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.297-302
    • /
    • 2011
  • In this study, used Trnsys and will apply metropolitan city distinguishes, fixations and BIPV systems the photovoltaic module arrangement environment which receives solar radiation quantity plentifully from the case design process which and most the outcome value simulation did analyzed. The climate data uses each metropolitan city distinguishes 20 average weather data, With measured values of horizontal solar radiation. The error scope appeared with 0.1%~6.7%. Variable of module arrangement Azimuth and angle of inclination of module and comparison group Module on due south direction angle of inclination $45^{\circ}$ day time set with the yearly average solar radiation quantity which receives. The result When the case comparison group which arranges a solar storehouse module with optimum environment and comparing until the minimum 1.4% - maximum 10.9% the solar radiation quantity difference appears with the thing, metropolitan city distinguishes considers the case solar radiation quantity which will arrange a photovoltaic module and that must establish with optimum environment judges.

  • PDF