• Title/Summary/Keyword: BIOMECHANICAL

Search Result 959, Processing Time 0.026 seconds

A Three-dimensional Biomechanical Model for Numerical Simulation of Dynamic Pressure Functional Performances of Graduated Compression Stocking (GCS)

  • Liu, Rong;Kwok, Yi-Lin;Li, Yi;Lao, Terence-T;Zhang, Xin;Dai, Xiao-Qun
    • Fibers and Polymers
    • /
    • v.7 no.4
    • /
    • pp.389-397
    • /
    • 2006
  • The beneficial effects of graduated compression stockings (GCS) in prophylaxis and treatment of venous disorders of human lower extremity have been recognized. However, their pressure functional performances are variable and unstable in practical applications, and the exact mechanisms of action remain controversial. Direct surface pressure measurements and indirect material properties testing are not enough for fully understanding the interaction between stocking and leg. A three dimensional (3D) biomechanical mathematical model for numerically simulating the interaction between leg and GCS in dynamic wear was developed based on the actual geometry of the female leg obtained from 3D reconstruction of MR images and the real size and mechanical properties of the compression stocking prototype. The biomechanical solid leg model consists of bones and soft tissues, and an orthotropic shell model is built for the stocking hose. The dynamic putting-on process is simulated by defining the contact of finite relative sliding between the two objects. The surface pressure magnitude and distribution along the different height levels of the leg and stress profiles of stockings were simulated. As well, their dynamic alterations with time processing were quantitatively analyzed. Through validation, the simulated results showed a reasonable agreement with the experimental measurements, and the simulated pressure gradient distribution from the ankle to the thigh (100:67:30) accorded with the advised criterion by the European committee for standardization. The developed model can be used to predict and visualize the dynamic pressure and stress performances exerted by compression stocking in wear, and to optimize the material mechanical properties in stocking design, thus, helping us understand mechanisms of compression action and improving medical functions of GCS.

Effects of Changes in Illumination Level and Slope on Fall-Related Biomechanical Risk Factors While Walking for Elderly Women (조도와 주로 변화가 노인 여성 보행 시 낙상 관련 운동역학적 위험요인에 미치는 영향)

  • Jeon, Hyun-Min;Park, Sang-Kyoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.4
    • /
    • pp.413-421
    • /
    • 2015
  • Objective : The purpose of this study was to investigate biomechanical changes of the lower limb including dynamic stability with changes in illumination (300Lx, 150Lx, and 5Lx) and slope (level and $15^{\circ}$ downhill) as risk factors for elderly falls. Method : Fifteen elderly females were selected for this study. Seven infrared cameras (Proreflex MCU 240: Qualisys, Sweden) and an instrumented treadmill (Bertec, USA) surrounded by illumination regulators and lights to change the levels of illumination were used to collect the data. A One-Way ANOVA with repeated measures using SPSS 12.0 was used to analyze statistical differences by the changes in illumination and slope. Statistical significance was set at ${\alpha}=.05$. Results : No differences in the joint movement of the lower limbs were found with changes in illumination (p>.05). The maximum plantar flexion movement of the ankle joints appeared to be greater at 5Lx compared to 300Lx during slope gait (p<.05). Additionally, maximum extension movement of the hip joints appeared to be greater at 5Lx and 150Lx compared to 300Lx during slope gait (p<.05). The maximum COM-COP angular velocity (direction to medial side of the body) of dynamic stability appeared to be smaller at 150Lx and 300Lx compared to 5Lx during level gait (p<.05). The minimum COM-COP angular velocity (direction to lateral side to the body) of dynamic stability appeared smaller at 150Lx compared to 5Lx during level gait (p<.05). Conclusion : In conclusion, elderly people use a stabilization strategy that reduces walk speed and dynamic stability as darkness increases. Therefore, the changes in illumination during gait induce the changes in gait mechanics which may increase the levels of biomechanical risk in elderly falls.

Straight-Forward versus Bicortical Fixation Penetrating Endplate in Lumbosacral Fixation-A Biomechanical Study

  • Karakasli, Ahmet;Acar, Nihat;Uzun, Bora
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.2
    • /
    • pp.180-185
    • /
    • 2018
  • Objective : Many lumbosacral fixation techniques have been described to offer a more screw-bone purchase. The forward anatomical fixation parallel to the endplate is still the most preferred method. Literature revealed little knowledge regarding the mechanical stability of lumbosacral trans-endplate fixation compared to the traditional trans-pedicular screw fixation method. The aim of this study is to assess the pull-out strength of lumbosacral screws penetrating the end plate and comparing it to the conventional trans-pedicular screw insertion method. Methods : Eight lumbar and eight sacral vertebrae, with average age 69.4 years, Left pedicles of the 5th lumbar vertebrae were used for trans-endplate screw fixation, group 1A, right pedicles were used for anatomical trans-pedicular screw fixation, group 1B. In the sacral vertebrae, the right side S1 pedicles were used for trans-endplate fixation, group 2A, left side pedicles were used for anatomical trans-pedicular screw fixation, group 2B. The biomechanical tests were performed using the axial compression testing machine. All tests were applied using 2 mm/min traction speed. Results : The average pull-out strength values of groups 1A and 1B were $403.78{\pm}11.71N$ and $306.26{\pm}17.55N$, respectively. A statistical significance was detected with p=0.012. The average pull-out strength values of groups 2A and 2B were $388.73{\pm}17.03N$ and $299.84{\pm}17.52N$, respectively. A statistical significance was detected with p=0.012. Conclusion : The trans-endplate lumbosacral fixation method is a trustable fixation method with a stronger screw-bone purchase and offer a good alternative for surgeons specially in patients with osteoporosis.

Analysis on Biomechanical Differences in Lower Limbs Caused by Increasing Heart Rates During Drop-landing (드롭랜딩 시 심박수 증가에 따른 하지의 생체역학적 차이 분석)

  • Hong, Wan-Ki;Kim, Do-Eun
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.2
    • /
    • pp.141-147
    • /
    • 2015
  • Objective : This study aimed to understand how increased heart rates at the time of drop landing during a step test would affect biomechanical variables of the lower extremity limbs. Background : Ballet performers do more than 200 landings in a daily training. This training raises the heart rate and the fatigability of the lower extremity limbs. Ballet performance high heart rate can trigger lower extremity limb injury. Method : We instructed eight female ballet dancers with no instability in their ankle joints(mean ${\pm}$ SD: age, $20.7{\pm}0.7yr$; body mass index, $19.5{\pm}1.2kg/m^2$, career duration, $8.7{\pm}2.0yr$) to perform the drop landing under the following conditions: rest, 60% heart rate reserve (HRR) and 80% HRR. Results : First, the study confirmed that the increased heart rates of the female ballet dancers did not affect the working ranges of the knee joints during drop landing but only increased angular speeds, which was considered a negative shock-absorption strategy. Second, 80% HRR, which was increased through the step tests, led to severe fatigue among the female ballet dancers, which made them unable to perform a lower extremity limb-neutral position. Hence, their drop landing was unstable, with increased introversion and extroversion moments. Third, we observed that the increasing 80% HRR failed to help the dancers effectively control ground reaction forces but improved the muscular activities of the rectus femoris and vastus medialis oblique muscles. Fourth, the increasing heart rates were positively related to the muscular activities of the vastus medialis oblique and rectus femoris muscles, and the extroversion and introversion moments. Conclusion/Application : Our results prove that increased HRR during a step test negatively affects the biomechanical variables of the lower extremity limbs at the time of drop landing.

Analysis of Projectile Factors and Biomechanical Characteristics of Men's Hammer Throwing during Turning Phases (남자 해머던지기 시 각 회전 별 역학적 특성과 투사 요인 분석)

  • Kim, Tae-Sam;Ryu, Ji-Seon;Lee, Mi-Sook;Yoon, Suk-Hoon;Park, Jae-Myoung
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.2
    • /
    • pp.141-152
    • /
    • 2011
  • The purpose of this study was to investigate the projectile factors and biomechanical characteristics of men's hammer throwing during turning phases. Four national leveled athletes including Korea national record holder participated in this study. After full warm-up, each participant performed 6 trials of hammer throwing with their best. The best recorded trial was selected from each participant and they were analyzed for this study. Three-Dimensional motion analysis using a system of 5 video cameras at a sampling frequency 60Hz was performed for this study. As the number of turns increased, athletes revealed following characteristics. 1) The single and double support time decreased. 2) The rotation foot was closed to axis foot and it revealed greater medio-lateral displacement than that of horizontal one. 3) At the transition point from double support to single support, ball was in front of rotation foot so that not much angular velocity obtained. For the projectile factors, projectile angle did not show differences while projectile height and velocity revealed differences among the participants. It may indicated that each athlete has different fitness and skill level to resist centrifugal force which become larger as the number of turn increased.