• Title/Summary/Keyword: BARS

Search Result 2,223, Processing Time 0.041 seconds

Force transfer mechanism in positive moment continuity details for prestressed concrete girder bridges

  • Hossain, Tanvir;Okeil, Ayman M.
    • Computers and Concrete
    • /
    • v.14 no.2
    • /
    • pp.109-125
    • /
    • 2014
  • The force transfer mechanism in positive moment continuity details for prestressed concrete girder bridges is investigated in this paper using a three-dimensional detailed finite element model. Positive moment reinforcement in the form of hairpin bars as recommended by the National Cooperative Highway Research Program Report No 519 is incorporated in the model. The cold construction joint that develops at the interface between girder ends and continuity diaphragms is also simulated via contact elements. The model is then subjected to the positive moment and corresponding shear forces that would develop over the service life of the bridge. The stress distribution in the continuity diaphragm and the axial force distribution in the hairpin bars are presented. It was found that due to the asymmetric configuration of the hairpin bars, asymmetric stress distribution develops at the continuity diaphragm, which can be exacerbated by other asymmetric factors such as skewed bridge configurations. It was also observed that when the joint is subjected to a positive moment, the tensile force is transferred from the girder end to the continuity diaphragm only through the hairpin bars due to the lack of contact between the both members at the construction joint. As a result, the stress distribution at girder ends was found to be concentrated around the hairpin bars influence area, rather than be resisted by the entire girder composite section. Finally, the results are used to develop an approach for estimating the cracking moment capacity at girder ends based on a proposed effective moment of inertia.

Seismic behavior of interior RC beam-column joints with additional bars under cyclic loading

  • Lu, Xilin;Urukap, Tonny H.;Li, Sen;Lin, Fangshu
    • Earthquakes and Structures
    • /
    • v.3 no.1
    • /
    • pp.37-57
    • /
    • 2012
  • The behavior of beam-column joints in moment resisting frame structures is susceptible to damage caused by seismic effects due to poor performance of the joints. A good number of researches were carried out to understand the complex mechanism of RC joints considered in current seismic design codes. The traditional construction detailing of transverse reinforcement has resulted in serious joint failures during earthquakes. This paper introduces a new design philosophy involving the use of additional diagonal bars within the joint particularly suitable for low to medium seismic effects in earthquake zones. In this study, ten full-scale interior beam-column specimens were constructed with various additional reinforcement details and configurations. The results of the experiment showed that adding additional bars is a promising approach in reinforced concrete structures where earthquakes are eminent. In terms of overall cracking observation during the test, the specimens with additional bars (diagonal and straight) compared with the ones without them showed fewer cracks in the column. Furthermore, concrete confinement is certainly an important design measure as recommended by most international codes.

Biomechanical Analysis of the Tippelt Motion on the Parallel Bars (평행봉 Tippelt 동작의 운동역학적 분석)

  • Kim, Min-Soo;Back, Jin-Ho;Back, Hun-Sig
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.1
    • /
    • pp.57-65
    • /
    • 2011
  • This research was conducted to biomechanically analyze Tippelt motion in parallel bars, and establish technical understanding. To achieve that goal, the performances of the Tippelt acts carried out by five world top-class national gymnasts in the parallel bars 3-dimensional cinematographic analysis and EMG analysis were conducted and following conclusion were obtained. The Tippelt motions of excellent national gymnasts perform tap motion through the down swing of a large circular movements, and perform kick-out motion rapidly extending shoulder joint angle and hip joint angle with the trunk in a position close to perpendicular position at the vertical downwardness of the grasping the bars. At this time, if handstand starting the movement is too delayed or rapidly down swung, it was shown that from the initial falling, unnecessary muscular power was wasted in trapezius, anterior deltoid, erector spinae, latissimus dorsi, upper rectus abdominis, lower rectus abdominis. The muscular parts in tap motion generating muscle action potential were pectoralis major, rectus femoris, upper rectus abdominis, lower rectus abdominis, and those in kick-out motion were upper rectus abdominis, lower rectus abdominis, trapezius and anterior deltoid.

Development of BARS for Evaluation of Computer Programmers (컴퓨터 프로그래머의 직무수행 평가를 위한 행동기술척도(BARS) 제작)

  • 김명소;김호동
    • Proceedings of the Korean Association for Survey Research Conference
    • /
    • 2000.06a
    • /
    • pp.89-115
    • /
    • 2000
  • The present study attempts to (1) identify the critical dimensions that affect job performance of computer programmers and (2) clarify the specific behaviors that are related to each performance dimension, and measure them fairly and accurately. In particular, this study focus on producing a Behaviorally anchored Rating Scales (BARS) with a high level of acceptability by both raters and rates. 422 computer programmers from 8 companies participated in the process of developing the scale, which consisted of typical 5 phases. The results demonstrated that 13 performance dimensions were derived and the final job performance rating scale was made by vertically arraying 5 representative behavior anchors order by their scale value for each of 13 dimensions.

  • PDF

The Influence of Frequency on Wayside Transmitter of ATP System upon Reinforcing Bars in Concrete Slab Track (콘크리트 슬래브궤도에서 ATP시스템 지상자의 주파수가 철근에 미치는 영향)

  • Kim, Min-Seok;Lee, Jong-Woo;Ko, Jun-Seog
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.691-706
    • /
    • 2008
  • ATP(Automatic Train Protection) system in railway signaling system is the important one grasping the position and velocity of a train. The wayside transmitter of ATP system is installed between rails. In concrete slab track, the signal current using wayside transmitter of ATP system is influenced by reinforcing bars. The magnetic coupling between reinforcing bars and wayside transmitter of ATP system as a filter makes an input current distorted. So, it makes an alternating current signal with a desirable size not transmit to on-board system of a train. Way to decrease the distortion of an input current signal frequency is to avoid maximum induction current frequency. And the induction phenomenon between reinforcing bars insulated and wayside transmitter of ATP system does not occur. In this paper, we represent the model about wayside transmitter of ATP system and reinforcing bars on the concrete slab tracks, and calculated the parameters demanded for the model. Also, we demonstrated it through the Maxwell program. Furthermore, we calculated impedance on wayside transmitter used in KVB system and ERTMS/ETCS system which are a kind of ATP system, frequency response of induction current, using the Matlab, and demonstrated the validity of it, using the PSpice program.

  • PDF

Development of BARS for Evaluation of Computer Programmers (컴퓨터 프로그래머의 직무수행 평가를 위한 행동기술척도(BARS) 제작)

  • Kim, Myoung-So;Kim, Ho-Dong
    • Survey Research
    • /
    • v.1 no.2
    • /
    • pp.89-115
    • /
    • 2000
  • The present study attempts to (1) identify the critical dimensions that affect job performance of computer programmers and (2) clarify the specific behaviors that are related to each performance dimension, and measure them fairly and accurately. In particular, this study focus on producing a Behaviorally Anchored Rating Scales(BARS) with a high level of acceptability by both raters and ratees. 422 computer programmers from 8 companies participated in the process of developing the scale, which consisted of typical 5 phases. The results demonstrated that 13 performance dimensions were derived and the final job performance rating scale was made by vertically arraying 5 representative behavior anchors ordered by their scale value for each of 13 dimensions.

  • PDF

A Study on the Improvement of Erection Bar Detailing in Domestic Building Construction (국내 건축물 조립용 철근 배근현황 및 개선방안에 관한 연구)

  • Jung, Hyeon-Ok;Cho, Hun-Hee;Park, U-Yeol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.2
    • /
    • pp.39-46
    • /
    • 2009
  • The erection bar is defined as the assistant bar used to fix the position of the reinforcing steel as the reinforcing steel is placed on site. As the erection bar do not bear the structural load and is not showed in the structural drawings, it is not managed importantly. But as chair bars in mat footing is used in large quantities to support the upper main bars, the detailing standards need to be suggested. and some erection bar is placed by experience of the fabricator and placer. Therefore, in this study, a survey about the erection bars was conducted to the reinforcement detailer, the fabricator and placer of domestic construction industry. 11 placing drawings is analyzed to find out the problems of detailing and the quantities of the erection bars. According to the analysis of the survey, the erection bar details in placing drawings were not standardized, and some erection bars are omitted in placing drawings. The improvement in the erection bar detailing was sought by analyzing the results of the survey.

A Study on the Weld Condition of Gas Pressure Welding in Steel Bars (철근 가스압접의 접합조건에 대한 연구)

  • 이철구;서성원;채병대;남복현
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.6
    • /
    • pp.57-62
    • /
    • 2001
  • Recently, it has increased that the importance of gas pressure weldment of steel bars in large construction bars. But there has hardly been any studies about it. Therefore we need more research. SD40 steel bar (32mm in diameter) which has been practically used at construction sites are tested about tension, bonding, fatigue, a macro structure and micro structure at foil gitudinal section and hardness to fed out the mechanical property and best welding ranges in some cases of mechanical cut and gas cut before gas pressure welded. It is that a gas-pressure welded zone of steel bar where was cleaned of impurities in way of two-upsetted method is more excellent bending and tension property than the regulation of KD D 0244. Also gas cut bars gained hardness from the heat affected zone so. In conclusion, to improve the weldability of steel bars, it is considered best to clean mechanically cut sutra- faces and then weld them by a method of 2 step upset way.

  • PDF

Behavior of Reinforced Dapped End Beams with T-headed Bar and Steel Fibers (헤디드 바와 강섬유로 보강된 Dapped End Beam의 구조 거동에 관한 실험적 연구)

  • Choi Jin Hyouk;Lee Chang Hoon;Lee Joo Ha;Yoon Young Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.49-52
    • /
    • 2004
  • In this studies, Dapped End Beams(DEB) having disturbed regions were designed by using strut tie model, and the main purpose of this paper is that whether T-headed bars and Steel fibers will be present or not. The ability of DEB with T-headed bars have a superior performance rather than others, such as improved ductility, larger energy adsorption and enhanced post-peak load carrying capability. The capacity of DEB with steel fibers also show increase of ductility, shear strength, fatigue strength and crack. Each DEB with both headed bars and steel fibers, headed bars, and steel fibers as a substitute reinforced steel in the disturbed regions and a DEB with only stirrup and tie reinforced steel were comparable. In contrast, the headed bar stirrups, the tie headed bars and the reinforced steel fibers did not lose their anchorage and hence were able to develop strain hardening and also served to delay buckling of the flexural compression steel. Excellent load-deflection predictions were obtained by increasing the tension stiffening effect to account for high load effects.

  • PDF

Effect of Composite Re-bars Embedded in Concrete on Surface Electrical Resistivity of Concrete (콘크리트내 섬유복합체 보강근이 표면저항치에 미치는 영향)

  • Moon, Do Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.6
    • /
    • pp.212-218
    • /
    • 2011
  • The effect of composite reinforcing bars on surface electrical resistivity of concrete was investigated through experimental program. The resistivity was measured by Wenner method using an equipment with 4 probe. Ordinary steel, GFRP, and CFRP reinforcing bars produced domestically were used and a specimen with no reinforcement was tested for the comparison. This investigation is motivated from the fact that measured value of resistivity of concrete is significantly affected by details of steel reinforcements, such as location, depth and direction of the internal steel reinforcement. These results could be valuable data for evaluation of corrosion degree of concrete structures reinforced or strengthened by the composite reinforcing bars.