• Title/Summary/Keyword: B2 계수

Search Result 1,427, Processing Time 0.047 seconds

On Negative Correlation Bit-to-Symbol(: B2S) Mapping for NOMA with Correlated Information Sources in 5G Systems (5G 시스템에서 상관 정보원의 비직교 다중접속을 위한 음수의 상관관계 계수 B2S 사상)

  • Chung, Kyu-Hyuk
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.5
    • /
    • pp.881-888
    • /
    • 2020
  • In this paper, in order to improve the degraded BER performance of the stronger channel user in non-orthogonal multiple access(: NOMA) with interactive mobile users, we propose the negative correlation bit-to-symbol(: B2S) mapping. First, the closed-form expression for the BER of the negative correlation B2S mapping receiver is derived, and then it is shown that the BER of the negative correlation B2S mapping receiver is improved, compared with those of the ideal perfect successive interference cancellation(: SIC) receiver and positive correlation receiver. Additionally, based on the analytical expression, signal-to-noise(: SNR) gain is calculated, and the superiority of the negative correlation B2S mapping receiver is validated.

Evaluation of the Second Order Analysis of Asymmetric Unbraced Frame by using Load Amplification Factor (하중증폭계수를 적용한 비대칭 비가새 골조 2차 해석 평가)

  • Kim, Hee-Dong
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.1
    • /
    • pp.87-97
    • /
    • 2010
  • The purpose of this study was to evaluate the validity of the second-order analysis for asymmetric unbraced frame using the load amplification factor suggested by design codes. For this purpose, the first-order analysis with the B1 and B2 factors suggested by KBC 2005 and the direct analysis with the load amplification factors suggested by KBC 2009 were performed for five story - two bay and five story - four bay asymmetric unbraced steel frames. The results of the analyses were compared with the results of the second-order inelastic analysis to evaluate the validity of the suggested methods. The main parameters of the analysis were the shape of the frame, the axial load ratio of the column, the methods of analysis and the location of column. The research results show that the asymmetric shape of the frame deteriorates the validity of the factor B2 and the suggested methods. The range of error is increased in case of irregular or inclined column.

Development of Stress Indices for Trunnion Pipe Support (원통형 배관 지지대의 응력계수 개발)

  • 김종민;박명규;엄세윤;이대희;박준수
    • Computational Structural Engineering
    • /
    • v.9 no.3
    • /
    • pp.115-123
    • /
    • 1996
  • A finite element analysis of a trunnion pipe anchor is presented. The structure is analyzed for the case of internal pressure and moment loadings. The stress results are categorized into the average (membrance) and the linearly varying(bending) stresses through the thickness. The resulting stresses are interpreted per Section III of the ASME Boiler and Pressure Vessel Code from which the Primary (B/sub 1/) and Secondary(C/sub 1/) stress indices for pressure, the Primary(B/sub 2R/, B/sub 2T/) and Secondary(C/sub 2R/, C/sub 2T/) stress indices for moment are developed. Several analyses were performed for various structural geometries in order to obtain empirical representation for the stress indices in terms of dimensionless ratios.

  • PDF

Evaluation of the Second Order Analysis of Unbraced Frame by using load amplification factor (하중증폭계수를 적용한 비가새 골조 2차 해석 평가)

  • Kim, Hee Dong;Lee, Myung Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.6
    • /
    • pp.627-636
    • /
    • 2009
  • The purpose of this study was to evaluate the validity of the second-order analysis using the load amplification factor suggested by design codes. For this purpose, the first-order analysis with the B1 and B2 factors suggested by KBC 2005 and the direct analysis with the load amplification factor suggested by KBC 2009 (draft) were performed for three-story -one-bay and five-story-three-bay unbraced steel frames. The results of the analyses were compared with the results of the second-order inelastic analysis to evaluate the validity of the suggested methods. The main parameters of the analysis were the scale of the frame, the axial load ratio of the column, and the methods of analysis. The research results showedthat the method suggested by KBC 2005 does not properly consider the second-order effect under the high axial load ratio, but the direct analysis method suggested by KBC 2009 (draft) properly estimates the second-order effect without any serious problem.

A Method to Obtain the CT Attenuation Coefficient and Image Noise of Various Convolution Kernels in the Computed Tomography (Convolution Kernel의 종류에 따른 CT 감약계수 및 노이즈 측정에 관한 연구)

  • Kweon, Dae-Cheol;Yoo, Beong-Gyu;Lee, Jong-Seok;Jang, Keun-Jo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.21-30
    • /
    • 2007
  • Our objective was to evaluate the CT attenuation coefficient and noise of spatial domain filtering as an alternative to additional image reconstruction using different kernels in abdominal CT. Derived from thin collimated source images was generated using abdomen B10 (very smooth), B20 (smooth), B30 (medium smooth), B40 (medium), B50 (medium sharp), B60 (sharp), B70 (very sharp) and B80 (ultra sharp) kernels. Quantitative CT coefficient and noise measurements provided comparable HU (hounsfield) units in this respect. CT attenuation coefficient (mean HU) values in the abdominal were 60.4$\sim$62.2 HU and noise (7.6$\sim$63.8 HU) in the liver parenchyma. In the stomach a mean (CT attenuation coefficient) of -2.2$\sim$0.8 HU and noise (10.1$\sim$82.4 HU) was measured. Image reconstructed with a convolution kernel led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image medications of image sharpness and noise eliminate the need for reconstruction using different kernels in the future. CT images increase the diagnostic accuracy may be controlled by adjusting CT various kernels, which should be adjusted to take into account the kernels of the CT undergoing the examination.

  • PDF

Stress Index Development of Trunnion Pipe Support for Pressure and Moment Loads (압력과 모멘트 하중을 받는 원통형 배관 지지대의 응력계수 개발)

  • Kim, J. M.;Lee, D. H.
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1996.04a
    • /
    • pp.27-39
    • /
    • 1996
  • A finite element analysis of a trunnion pipe anchor is presented. The structure is analyzed for the case of internal pressure and moment loadings. The stress results are categorized as average and linearly varying(through the thickness) stresses. The resulting stresses are interpreted per Section 111 of the ASME Boiler and Pressure Vessel Code from which the Primary(B$_1$) and Secondary(C$_1$) stress indices for pressure, the Primary(B$_2$) and Secondary(C$_2$) stress indices for moment are developed. Several analysis were peformed on various structural geometries in order to determine empirical relationships for the stress indices as a function of dimensionless ratios.

  • PDF

A Study on Optical Properties of Red Tide Algal Species (적조 원격탐사 기술 개발을 위한 적조생물의 광특성 연구)

  • Lee, Nu-Ri;Moon, Jeong-Eon;Ahn, Yu-Hwan;Yang, Chan-Su;Yoon, Hong-Joo
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.11a
    • /
    • pp.187-191
    • /
    • 2006
  • This research is about the optical characteristics of algae which is collected from Nam-Hae for basic research of red tide remote sensing technique development 21 kinds of red tide organisms were cultivated to investigate optical characteristics of them in the level of laboratory, and chlorophyll specific absorption coefficient $(a^*)$ and backscattering coefficient $(b_b^*)$ are estimated by using spectrophotometer. Absorption spectrums according to species appeared to range from 0.005 to 0.06 $(m^2/mg)$, and the shapes of spectrums were also different. The range of $b_b^*$ appeared to be $10^{-2}\sim10^{-4}m^2/mg$, which had about 100 times differences between species, and the shape of spectrum have significant difference between species. These results will input as an ocean color model input parameter from ocean color.

  • PDF

Inherent Optical Properties of Red Tide Algal for Ocean Color Remote Sensing Application (해색원격탐사 활용을 위한 적조생물종 고유 광특성 연구)

  • Ahn, Yu-Hwan;Moon, Jeong-Eon;Seo, Won-Chan;Yoon, Hong-Joo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.1
    • /
    • pp.47-54
    • /
    • 2009
  • This research is about the inherent optical properties(IOPs) of algae which is collected from Nam-Hae for basic research of red tide remote sensing technique development. 21 kinds of red tide organisms were cultivated to investigate IOPs of them in the level of laboratory, and specific absorption coefficient of phytoplankton($a^*$) and backscattering coefficient of phytoplankton(${b_b}^*$) are estimated by using spectrophotometer. Absorption spectrums according to species appeared to range from 0.005 to 0.06 ($m^2{\cdot}mg^{-1}$), and the shapes of spectrums were also different. The range of ${b_b}^*$ appeared to be $10^{-2}{\sim}10^{-4}\;m^2{\cdot}mg^{-1}$, which had about 100 times differences between species, and the shape of spectrum have significant difference between species. These results will input as a remote sensing reflectance model input parameter from ocean color.

  • PDF

Characteristics of 3-dB Coupler using Broadside Slot Coupled Lines (Broadside 슬롯 결합 선로를 이용한 3 dB 결합기 특성)

  • Young Kim
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.4
    • /
    • pp.417-422
    • /
    • 2023
  • This paper presents various methods for implementing 3-dB coupler using a broadside slot coupled lines and analyze its characteristics. The ideal coupler of the tandem structure is analyzed on the premise that both the reflection coefficient and the isolation coefficient of the first and second coupler connections are zero. However, since the reflection and isolation coefficients of most couplers are not zero, the S-parameter cascade calculation method was used to check how to the characteristics of the coupler change due to this. In order to confirm that these characteristics appear, a 3-dB coupler was fabricated with one stage and two and three stages of a tandem structure using a broadside slot coupled lines at a center frequency of 2 GHz, and it was confirm that the characteristics of tandem coupler change due to the non-zero reflection coefficient and isolation coefficient of the connection part of the coupler.

Design of the LSF Parameter Quantizer for the Wideband Speech Codec (광대역 음성 부호화기용 선 스펙트럼 주파수 계수 양자화기 설계)

  • 지상현;강상원;윤병식
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.29-34
    • /
    • 2001
  • In this paper, we designed an LSF coefficient quantizer of the wideband speech codec that can produce high quality speech service. For the efficient LSF coefficient quantizer, the interframe correlation was used. Also we separately quantized the LSF coefficients with high and low interframe correlation. Predictive pyramid vector quantizer (PVQ) was used for quantizing the LSF coefficients with high interframe correlation, and PVQ was used for quantizing the LSF coefficients with low interframe correlation. Experiments show that the proposed UF quantizer can quantize LSF information in 40 bits/frame, with an average spectral distortion (SD) of 1 dB and less than 3.87% frames having SD greater than 2 dB.

  • PDF