• Title/Summary/Keyword: B125

Search Result 936, Processing Time 0.025 seconds

The Application of New Calibrator[I-125]Set for Equipment Quality Management (장비정도관리에 Calibrator[I-125] Set 적용)

  • Kim, Ji-Na;An, Jae-seok;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.108-111
    • /
    • 2015
  • Purpose Lately, in accordance with the increasing interest about Healthcare accreditation program and International laboratory accreditation scheme, requirements about the instrument quality management are gradually taking shape. In nuclear medicine In vitro laboratory, the most typical instruments are multi detector gamma counter and automatic dispensing system. Each laboratory continue with the quality control adequate for circumstances. The purpose of this study is to application and establish the new Calibrator[I-125]Set which is efficient at standardization of equipment quality management. Materials and Methods Deviation between detectors were measured with 12 solid samples of the Calibrator[I-125]Set. their activities differ from each other by less than 1%. Multi detector gamma counters are GAMMA-10;Shinjin medics. Inc, Goyansi, Korea(Gamma counter A), SR300;Stratec biomedical systems AG, Gewerbestr, Germany(Gamma counter B) and COBRA II; Packard Instrument Co. Inc, Meriden, USA(Gamma counter C). Evaluation of two automatic dispensing system used A, B liquid tracer of the Calibrator[I-125]Set. After dispensing and counting, calculated using the ratio of the measured value and proposed value. We used solution A for 20, 25ul and solution B for 50, 100ul. Method of data analysis and reference range was provided by kit documentation. Furthermore, we could calculate our counter efficiency indirectly. Results The CV(%) of measured values by Gamma counter A, B, C are 0.34, 0.70, 1.30. Calculated value are 1.05314, 2.10419, 4.08485. Provided reference range is less than 3. A dispensing system's calculated values are 0.986, 0.989, 1.023, 1.017 and B are 0.874, 0.725, 1.021, 0.904. Provided reference range is from 0.95 to 1.05. Also, counter's efficiency are 74.18, 72.79, 74.32% at counter A, B, C and efficiency of the one detector counter is 79.26%. Conclusion If using this Calibrator[I-125]Set after verifying whether quality assurance, is applicable to equipment quality management on behalf of the role of gold standard.

  • PDF

Differential Analgesic and Adverse Effects of 0.125% and 0.0625% Bupivacaine Coadministered Epiduraly with Morphine (경막외 Morphine과 병합 투여되는 0.125%와 0.0625% Bupivacaine의 술 후 제통효과 및 부작용의 차이)

  • Lee, Jai-Min;Choi, Jong-Ho
    • The Korean Journal of Pain
    • /
    • v.12 no.1
    • /
    • pp.48-53
    • /
    • 1999
  • Background: Despite the popularity of epidural bupivacaine-morphine infusions for postoperative pain management, the optimum concentrations and dosages of bupivacaine have not been determined. At present, due to the disadvantages conferred by intense motor block and the increased risk of toxicity, many trials focus on reducing bupivacaine concentration and thus the evaluation of concentrations less than 0.1% may be warranted. Methods: Forty patients having epiduro-general anesthesia for hysterectomy were randomly assigned to one of two study groups. As a mean of postoperative pain control, all received 2 mg of epidural morphine bolusly 1 hr before the end of surgery and continuous epidural infusion was started using a two-day Infusor containing 4 mg of morphine in 100 ml of 0.125% bupivacaine (Group 0.125B, n=20) or 100 ml of 0.0625% bupivacaine (Group 0.0625B, n=20). Study endpoints included visual analog scales (VAS) for pain during rest and movement, sensory change and motor blockade. They were assessed at 2, 4, 8, 16, 24, 32, 40 and 48 hrs postoperatively. Results: For VAS during rest, no significance could be found between two groups over the course of study. But for VAS during movement, the 0.125B group showed more satisfactory results especially during early postoperative periods. For the incidence of complications, the 0.125B group revealed greater frequency of sensory change (25.0%) and motor blockade (10.0%) compared with the 0.0625B group. Conclusion: This study suggests that 0.0625% bupivacaine with morphine via epidural route was sufficient for pain control during rest but it was not satisfactory during movement especially in early postoperative periods. We also recommend that careful attention to motor blockade should be paid when using 0.125% bupivacaine.

  • PDF

Epithelial to Mesenchymal Transition in CAPD Patients (복막의 섬유화 기전으로서의 상피중간엽전이)

  • Do, Jun-Young
    • Journal of Yeungnam Medical Science
    • /
    • v.23 no.1
    • /
    • pp.10-18
    • /
    • 2006
  • Epithelial to mesenchymal transition (EMT) is an important etiologic factor for the development of peritoneal fibrosis in CAPD patients. Mesothelial cells are main source of trans-differentiated fibroblasts under stress from the bioincompatible peritoneal dialysate. In our study there was no difference in dialysate TGF-${\beta}$ and VEGF between the low and high GDP groups during an initial 12 months. However, after adjusting with D-CA125, the low GDPs group showed a significantly lower D-TGF-${\beta}$/D-CA125 and D-VEGF/CA125 during the initial 12 months. Among the adjusted peritoneal growth factors for CA125, VEGF/CA125 and TGF-b/CA125 were factors significantly associated with greater EMT in this study. Adjustment of the peritoneal growth factor for effluent CA125 (surrogate for mass of HPMCs) revealed significant association with EMT suggesting that the fibroblastoid transition from HPMCs could be affected by the amount of intraperitoneal growth factors (TGF-b, VEGF) per unit mass of HPMCs. There was significant improvement in both cell score and D-CA125 at the sixth and 12th months after switching from a high GDPs solution to a low GDPs solution. Use of icodextrin solution in patients who had average peritoneal transport showed not only better systemic effects such as decreased glucose absorption via dialysate but also preservation of the peritoneum, including less EMT and high mesothelial bulk mass. In conclusion, Therapy with low GDP solution including icodextrin may positively impact preservation of the peritoneal membrane integrity and prevention of peritoneal fibrosis with time on PD.

  • PDF

The Binding Study of $^{125}I-LSD$ to Platelet Membrane in Alcoholism (주정중독환자의 혈소판막과 $^{125}I-LSD$ 결합에 관한 연구)

  • Chung, Young Chul;Eun, Hong Bai
    • Korean Journal of Biological Psychiatry
    • /
    • v.3 no.2
    • /
    • pp.245-250
    • /
    • 1996
  • This research was performed to find out the changes of serotonin receptors in the platelet of alcoholics. Using $_{125}I-LSD$ as a radioligand. We obtained the following results. 1) In the comparison of patients vs controls, $B_{max}$ of the former was significantly higher than that of the latter(P=0.0017). But there was no significant difference in the Kd between the two groups. 2) In the comparison of type 1 vs type 2, alcoholics by cloninger's classification $B_{max}$ of the latter was significantly higher than that of the farmer(P=0.0396). But there was no significant difference in the Kd between the two groups. 3) In the comparison of alcohol abuse vs alcohol dependence, there were no significant differences in the value of $B_{max}$ and Kd between the two groups. These results support the hypothesis of serotonin-deficit in alcoholism. Furthermore, it can be inferred that the increase of platelet serotonin receptors in alcoholics might be used as a trait marker.

  • PDF

Comparison of SE Evaluation Methods for HEMP Shelters (HEMP 방호시설의 SE 평가방법의 비교)

  • Chung, Yeon-Choon;Lee, Jongkyung;Kwun, Suk-Tai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.11
    • /
    • pp.1197-1200
    • /
    • 2014
  • Two test standards to be applied for evaluating shielding effectiveness of HEMP protection facilities, MIL-STD-188-125-1 and IEEE std. 299, provide different test results in spite of the same facility. In particular, at the frequency range of 10 kHz~20 MHz, it is confirmed that the test results by the IEEE Std. 299 are about 20~30 dB lower than the evaluated results by MIL-STD-188-125-1. These results are due to the different measurement conditions specified in the two test standards. Therefore, IEEE Std. 299 can be applied for the shortening of test distance, but the required SE performance based on MIL-STD-188-125-1 must be modified.

A Study on the Noises of Fishes (어류가 내는 소리에 관하여)

  • CHO, AM;CHANG, Jee-won
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.8 no.1
    • /
    • pp.14-22
    • /
    • 1972
  • For the development of acoustic fishing method, the noises of fishes have been recorded and analy/'ed by many scientists. Some specimens of fishes were selected as such Cyprinus carpio, Ctenopharyngodon idellus Carassius carassius, and pagrosol1ms major in this experiment. The noises such as feeding noise, driving away noise, jumping noise and fi llip noise were recorded by the tape recorder, Sony Model 262, through the underwa te r microph I one, Oki ST 6582, and analyzed in frequencies bv octave band analyzer, Rion SA-55, and sound pressure level of source by sound level meter, Rion NA-opNN The supplied feed was placed within 5em apart from the hydrophone. The result of analyzed noises were as follow. Cyprinus carjJio; Feeding noise 250- 500 cps, 92- 99 dB Driving away noise 125-2, 000 eps, 101-112 dB Jumping noise 125-2, 000 eps, 99-116.5 dB Ctenopharyngodon idcllus; Driving away noise 125-1, 000 cps, 96-109 dB Carassius carassius; Feeding noise 250- 500 cps, 91. 5- 99.5 dB Driving away noise 125-1, 000 eps, 99-108 dB Carassius auratus Feeding noise 250 eps, 94-101 dB Driving away noise 125-1, 000 cps, 98-110 dB Pagrosomus major Feeding noise 230-500 cps, 90-101 dB Fillip noise 500 cps, 98-108 dB (1) Feeding noise was produced as like as snap noise of twig and gulping down saliva noise in human and dominant frequency range of the noise is 250-500 cps and noise level 90-101 dB. (2) It was found that feeding noise were not a monotonic but a complex tones though fish took the same food. (3) Driving away noise was produced not so keen and the wave form of the noise is rising very sharp and big amplitude in the oscillograph. Dominant frequency range of this noise was about 150-1, 000 cps and noise level 96-112 dB except thut of carp. (4) The frequency of snapper's fillip noise, when it produced by caudal fin in swimming at the surface of water, was 500 cps and noise level 93-108 dB snd that of jumping noise of carp about 150-2, 000 cps and noise level 99-116.5 dB.

  • PDF

Inhibitory Mechanism of a New Antitumor Agent DA125 on DNA Replication (새로운 항암제 DA-125의 유전자 복제 억제 기작)

  • 이상광;김도진;오유택;이상득;우은란;신차균
    • YAKHAK HOEJI
    • /
    • v.43 no.5
    • /
    • pp.623-628
    • /
    • 1999
  • DA-125, a new antitumor agent, was compared with adriamycin, a known DNA intercalator, in terms of inhibitory mechanism of DNA replication by using replicating simian virus 40 (SV40) genome in vivo. In analyzing the SV40 DNA replication intermediates present in cells treated with DA-125, it was not observed to accumulate B-dimers of SV40 DNA which are prominent in adriamycin-treated cells. However, treatment with DA-125 induced dose-dependent formation of DNA-topoisomerase complex which is characteristic of topoisomerase poisons. In addition, DA-125 showed more efficient in inhibiting SV40 DNA replication than adriamycin. Therefore, on the basis of this observation, we suggest that DA-125, a derivative of adriamycin, inhibits DNA replication by blocking topoisomerase activity as a toposomerase poison although adriamycin blocks topoisomerase activity as a DNA intercalator.

  • PDF