• 제목/요약/키워드: B-field

검색결과 5,105건 처리시간 0.033초

Lorentz Force Density Distribution of a Current Carrying Superconducting Tape in a Perpendicular Magnetic Field

  • Yoo, J.;Kwak, K.;Rhee, J.;Park, C.;Youm, D.;Park, B.J.;Han, Y.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권4호
    • /
    • pp.13-16
    • /
    • 2010
  • The Lorentz force distribution of a high $T_c$ superconducting tape with increasing transport currents in magnetic field ($H_a$) was visualized. The external magnetic field was applied normally to the coated conductor tape surface after zero-field cooling, and the transport current ($I_a$) was increased stepwise from 0 to 90 % of the values of the critical current ($I_c$ ($H_a$)) at applied filed, Ha. The field distribution (H(x)) near the sample surface across the tape width (2w) was measured using the scanning Hall probe method. Applying an inversion to the measured field distribution, we obtained the underlying current distribution (J(x)), from which the magnetic induction, B(x) was calculated with Biot-Savart law. Then Lorentz force per unit length was calculated using F(x)=J(x)${\times}$B(x), which appears to be very inhomogeneous along the tape width due to the complicated distributions of J(x) and B(x).

A Study of Magnetic Properties in $Fe_{73.9}Cu_{1.0}Nb_{3.5}Si_{14.0}B_{7.6}$ by Magnetic Annelaing

  • Kim, Eng-Chan;Kim, Jin-Eui;Nam, Hyo-Duk
    • Transactions on Electrical and Electronic Materials
    • /
    • 제1권3호
    • /
    • pp.29-33
    • /
    • 2000
  • The crystallographic and high frequency characteristics of $Fe_{73.9}Cu_{1.0}Nb_{3.5}Si_{14.0}B_{7.6}$ soft magnetic alloys were investigated under magnetic field annealing, The crystallization fraction of annealed samples with longitudinal magnetic fields is higher than that of samples without magnetic field. When the transverse magnetic field is applied, the crystallization fraction does not increases but decreases until $500^{circ}C$. It is found that for samples, the saturation induction are all same with 1.3 T. The coercive field of as-cast samples is 1.03 A/cm, but in annealed samples it decrease from 0.56 to 0.1A/cm with increasing annealing temperature from 400 to $550^{circ}C$. The squareness of annealed samples under transverse magnetic field has a small value than that of both without field and with longitudinal field annealing. It is noted that the magnetic field annealing with transverse direction to amorphous $Fe_{73.9}Cu_{1.0}Nb_{3.5}Si_{14.0}B_{7.6}$ profoundly influenced on the Mossbauer spectra in contrast to that with longitudinal direction and without magnetic field.

  • PDF

ZORA DFT Calculation of $^{11}$B Electric Field Gradient Tensor for Lithium Borates

  • Woo, Ae-Ja;Wasylishen, Roderick E.
    • 한국자기공명학회논문지
    • /
    • 제8권2호
    • /
    • pp.70-76
    • /
    • 2004
  • ZORA-DFT calculations of $^{11}$B EFG (electric field gradient) tensors for lithium borates, LiB$_3O_5$ (LBO) and Li$_2B_4O_7$ (LTB), were performed. The calculated values of 11B quadrupole coupling constant and asymmetry parameter are in good agreement with the experimental values. The sign of the quadrupole coupling constant for the tetrahedral boron site was deduced from the distortion from the ideal tetrahedral symmetry.

  • PDF

지구력 훈련이 혈중 호모시스테인과 비타민 B 수준에 미치는 영향 -남자 고등학생 필드하키선수를 대상으로- (Effect of Endurance Training on the Plasma Honocysteine and B Vitamin Levels in Male Adolescent Field Hockey Players)

  • 강해선;이명천;유영채;장남수
    • Journal of Nutrition and Health
    • /
    • 제37권10호
    • /
    • pp.881-887
    • /
    • 2004
  • Elevated plasma homocysteine is an independent risk factor for the development of cardiovascular disease. Exercise is generally believed to reduce the plasma homocysteine levels and therefore, being beneficial for cardiovascular disease (CVD). However, there is a possibility that athletes undergoing strenuous training and competition which increase oxidative stress may suffer from increased plasma homocysteine levels. The purpose of this study was to investigate the influence of endurance training on the plasma concentrations of B vitamins and homocysteine in 23 male adolescent field hockey players. Data collection and blood sampling was performed during the training period and non-training period. Following the training period, significant changes in energy and vitamin B6 intakes were observed in these subjects. Plasma vitamin B2, pyridoxal phosphate (PLP) and homocysteine levels were significantly higher during the training period than non-training period, whereas no difference was observed in plasma folate and vitamin B12 levels. Positive correlation was observed between plasma folate and folic acid intakes. When energy, B vitamin intakes were adjusted there was a significant negative correlation between plasma homocysteine levels and plasma riboflavin, folate and vitamin B12 levels. In conclusion, it is suggested that athletes with oxidative stress by strenuous exercise may need B vitamins since riboflavin, folic acid and vitamin Bl2 were shown to be negatively correlated with plasma homocysteine in athletes during the training period.

저항 부하된 소형 다이폴을 이용한 3축 등방성 전기장 프로브 설계 (3-Axial Isotropic Electric-Field Probe Design with Resistor-Loaded Short Dipole)

  • 문성원;장병준
    • 한국전자파학회논문지
    • /
    • 제28권3호
    • /
    • pp.246-249
    • /
    • 2017
  • 본 논문에서는 저항 부하를 갖는 소형 다이폴을 이용하여 3축 등방성 전기장 측정 프로브를 설계하였다. 특히, 상용 저항소자와 PCB를 이용함으로써 상용화에 장점이 있다. 설계된 전기장 측정 프로브는 저항 부하로 인한 광대역 특성으로 100 kHz에서 3 GHz까지의 광대역 특성을 갖는다. 제작 결과 광대역에 걸쳐 ${\pm}0.39dB$ 이내의 등방성 특성, 0.1 V/m의 수신감도 특성, 3 dB 이내의 주파수 응답 특성을 얻었다. 특히 250 kHz에서 3 GHz까지의 주파수 응답 특성은 ${\pm}1.4dB$의 우수한 특성을 보여 기존 전기장 프로브에 비해 우수한 특성 개선을 보였다.

Co-Fe-B 자왜변환기를 이용한 간섭계형 광섬유 자계센서의 동작특성

  • 이경식
    • 한국광학회지
    • /
    • 제4권4호
    • /
    • pp.474-479
    • /
    • 1993
  • Melt-spun법에 의해서 자왜특성을 갖는 Co-Fe-B ribbon을 제작한 후 광섬유 Mach-Zehnder 간섭계의 sensing-arm에 부착하여 간섭형 자계센서를 구성하였다. Co-Fe-B 자왜변환기로 구성된 자계센서의 동작실험 결과 ac 자왜 응답이 최대가 되는 dc 바이어스 자계는 출력이 0인 바이어스 지점으로부터 0.970e 정도 떨어져 있었으며, 최소 감지자장은 3kHz에서 3.9${\times}10^{-5}$ Oe(rms)/${\sqrt{Hz}}$였다. 응답이 최대가 되는 지점에 바이어스를 고정시켰을 때 ac 자계셈서의 출력이 포화되기 시작하는 입력 자계신호는 1 Oe(rms) 근처였다. Co-Fe-B 자왜변환기의 주파수 특성곡선에서 응답이 피크가 되는 주파수는 ~500Hz였다.

  • PDF

TiO2 Nano-doping Effect on Flux Pinning and Critical Current Density in an MgB2 Superconductor

  • Kang, J.H.;Park, J.S.;Lee, Y.P.;Prokhorov, V.G.
    • Journal of Magnetics
    • /
    • 제16권1호
    • /
    • pp.15-18
    • /
    • 2011
  • We have studied the $TiO_2$ doping effects on the flux pinning behavior of an $MgB_2$ superconductor synthesized by the in-situ solid-state reaction. From the field-cooled and zero-field-cooled temperature dependences of magnetization, the reversible-irreversible transition of $TiO_2$-doped $MgB_2$ was determined in the H-T diagram (the temperature dependence of upper critical magnetic field and irreversibility line). For comparison, the similar measurements are also obtained from SiC-doped $MgB_2$. The critical current density was estimated from the width of hysteresis loops in the framework of Bean's model at different temperatures. The obtained results manifest that nano-scale $TiO_2$ inclusions served as effective pinning centers and lead to the enhanced upper critical field and critical current density. It was concluded that the grain boundary pinning mechanism was realized in a $TiO_2$-doped $MgB_2$ superconductor.

Design of Crisscrossed Double-Layer Birdcage Coil for Improving B1+ Field Homogeneity for Small-Animal Magnetic Resonance Imaging at 300 MHz

  • Seo, Jeung-Hoon;Han, Sang-Doc;Kim, Kyoung-Nam
    • Journal of Magnetics
    • /
    • 제20권3호
    • /
    • pp.308-311
    • /
    • 2015
  • We design a crisscrossed double-layer birdcage (DLBC) coil by modifying the coil geometry of a standard single-layer BC (SLBC) coil to enhance the homogeneity of transmitting magnetic flux density ($B_1{^+}$) along the main magnetic field ($B_0$)-direction for small-animal magnetic resonance imaging (MRI) at 300 MHz. The performance assessment of the crisscrossed DLBC coil is conducted by computational analysis with the finite-difference time domain method (FDTD) and compared with SLBC coil in terms of the $B_1$ and the $B_1{^+}$ distribution. As per the computational calculation studies, the mean value in the two-dimensional $B_1{^+}$ map obtained at the mid-axial slice with the proposed DLBC coil is slightly lower than that obtained with the SLBC coil, but the $B_1{^+}$ value of the DLBC coil in the outermost plane (40 mm away from the central plane) shows improvements of 19.3% and 24.8% over the SLBC coil $B_1{^+}$ value when simulating a spherical phantom and realistic mouse body modeling. These simulation results indicate that, the $B_1{^+}$ homogeneity along the z-direction was improved by using DLBC configuration. Our approach enables $B_1{^+}$ homogeneity improvement along the zdirection, and it can also be applied to ultra-high field (UHF) MRI systems.

Stereo-PIV/LIF의 속도장과 농도장 동시측정 기법을 이용한 러쉬톤 교반기내 난류특성에 관한 연구 (A Study on the Turbulent Characteristics of Rushton Turbine Mixer by Simultaneous Measurement of Velocity and Concentration field with Stereo-PIV/PLIF Technique)

  • 민영욱;김윤기;김경천
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.365-370
    • /
    • 2004
  • Simultaneous measurement with PLIF(Planar Laser-Induced Fluorescence) and Stereo-PIV(Stereo Particle Image Velocimetry) was performed to investigate the structural characteristics of flow field in Rushton Turbine Mixer. Instantaneous 3D velocity fields are measured by two 2K${\times}$2K CCD cameras focused on an object plane with the angular displacement methods while the concentration fields are obtained through the measurement of the fluorescence intensity of Rhodamine B tracer excited by the second pulse of Nd:Yag laser light. Image distortion due to the camera view-angle is compensated by a mapping function. Finally, the spatial structures of turbulent flow around Rushton turbine were identified by the calculation of synchronized data of the velocity field and concentration field.

Whole brain radiotherapy using four-field box technique with tilting baseplate for parotid gland sparing

  • Park, Jaehyeon;Yea, Ji Woon
    • Radiation Oncology Journal
    • /
    • 제37권1호
    • /
    • pp.22-29
    • /
    • 2019
  • Purpose: The aim of this study is to evaluate the efficacy and feasibility of four-field box whole brain radiotherapy (FB-WBRT) with tilting baseplate by comparing bilateral WBRT (B-WBRT). Methods and Materials: Between March 2016 and September 2018, 20 patients with brain metastases underwent WBRT using the four-field box technique. WBRT is performed with a dose of 30 Gy in 10 fractions daily. Two computed tomography simulations per person were performed. One was in the traditional supine position for B-WBRT and the other by applying the tilting acrylic supine baseplate to elevate the head by 40° for FB-WBRT. The B-WBRT used the field-in-field technique, which is the most commonly used method in our institution. The FB-WBRT comprised anterior, posterior, and bilateral beams. A wedge was applied in anterior and posterior fields to compensate for skull convexity. Results: The average of Dmean of both parotid glands was 10.2 Gy (range, 3.8 to 17.8 Gy) in B-WBRT and 5.4 Gy (range, 2.0 to 11.7 Gy) in FB-WBRT (p < 0.05). Compared to B-WBRT, FB-WBRT reduced the mean dose of the right and left parotid glands from 10.1 Gy to 4.9 Gy and from 10.4 Gy to 5.8 Gy, respectively (p < 0.05). Further, V5, V10, V15, V20, and V25 for the parotid gland decreased significantly in FB-WBRT (p < 0.05). The Dmax and Dmean of lens decreased according to the dose-volume histogram. Conclusion: Compared to B-WBRT, FB-WBRT with a tilting baseplate is a simple and effective method that takes feature of noncoplanar beam to protect the parotid gland.