• Title/Summary/Keyword: B-field

Search Result 5,108, Processing Time 0.03 seconds

A Study on the Technical Regulation of Weak Electric Filed Strength Radio Equipment about 8.2Hz Frequency Band (8.2MHz 대역 미약 전계강도 무선기기의 출력기준에 관한 연구)

  • Kim, Sun-Youb;Ra, Yoo-Chan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2498-2504
    • /
    • 2009
  • This paper compared the output limit value of the Korean weak electric field strength wireless device in the 8.2MHz band with the standard values of foreign countries. Through this, the study confirmed that the Korean regulation was lower by about 10-20dB than those of the USA or Europe. In order to prove this, the study measured outputs by entrusting the 8.2MHz EAS system to two measuring companies. As a result of these measurements, electric field strengths were shown to be $70.6dB{\mu}V/m$ and $68.3dB{\mu}V/m$ respectively, and these values were confirmed to exceed the current Korean standard of $59.8dB{\mu}V/m$. Accordingly, it is deemed necessary to review the specifications of the Korean standard in the 8.2MHz band.

A Study on the Technical Regulation of Weak Electric Filed Strength Radio Equipment about 58kHz Frequency Band (58kHz 대역 미약 전계강도 무선기기 기술 기준에 관한 연구)

  • Park, Hyoung-Keun;Kim, Sun-Youb;Ra, Yoo-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2319-2325
    • /
    • 2009
  • This paper compared the output limits value of the Korean weak electric field strength wireless device in the 58kHz band with the standard values of foreign countries. Through this, the study confirmed that the Korean regulation was lower by about 50dB than those of the USA or Europe. In order to prove this, the study measured outputs by entrusting the 58kHz EAS system to two measuring companies. As a result of these measurements, electric field strengths were shown to be $112dB{\mu}V/m$ and $08dB{\mu}V/m$ respectively, and these values were confirmed to exceed the current Korean standard of $102.7dB{\mu}V/m$. Accordingly, it is deemed necessary to review the specifications of the Korean standard in the 58kHz band.

Variation of Magnetic Properties of (Nd, Dy)-Fe-B Sintered Magnets with Compaction Conditions ((Nd, Dy)-Fe-B 소결자석의 성형조건에 따른 자기특성 변화)

  • NamKung, S.;Lee, M.W.;Han, S.J.;Jang, T.S.
    • Journal of Powder Materials
    • /
    • v.19 no.1
    • /
    • pp.1-5
    • /
    • 2012
  • In order to improve the remanence of (Nd, Dy)-Fe-B sintered magnets, we investigated the influence of compaction conditions such as packing density, applied field and green density on the magnetic properties. While the remanence decreased with increasing the packing density and green density, it increased with the increase of the applied field. In addition, XRD analysis revealed that the remanence was enhanced as the degree of powder alignment was improved. The green density was more influential on the remanence than the packing density and applied field.

A Evaluation Study on Reduction Method of Floor Impact Noise through Field Test and the Effective Method for Heavy Impact Noise (현장실험을 통한 바닥충격음 저감공법의 성능평가 및 중량충격음 저감 방안)

  • Lee, Byung-Kwon;Bae, Sang-Hwan;Hong, Cheon-Hwa
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.451-456
    • /
    • 2004
  • In this study, evaluation was carried out for reduction method of floor impact noise through field test and the effective methods for heavy impact noise were proposed. As a field test, impact noise reduction materials such as EPP, EEPS, EVA, PE and so on, did not satisfied the recommandation value at the condition of 150mm thickness concrete slab. The evaluation results for those materials by 'inverse A curve' showed $53\sim55dB$ at heavy impact noise and $53\sim58dB$ at light impact noise. But, two methods proposed by authors were evaluated $47\sim50dB$ at heavy Impact noise and $54\sim58dB$ at light Impact noise on the similar concrete slab thickness.

  • PDF

Study on the shape design of field coil in HTS generator considering stress condition

  • Jo, Young-Sik;Lee, Ju-Min;Hong, Jung-Pyo;Lee, Ju;Sohn, Myung-Hwan;Kwon, Young-Kil;Ryu, Kang-Sik
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.257-261
    • /
    • 2000
  • The value of I$_c$(critical current) in HTS (High Temperature Superconductor) tape has a great influence on B${\bot}$(vertical field). Therefore, in shape design of field coil for the HTSG(High Temperature Superconducting Generator), a method to reduce the B${\bot}$ should be considered in order to maintain the stability and substantial improvement on the performance. On the basis of the magnetic field analysis, this paper deals with various field coil shape according to the iron plate to obtain small B${\bot}$ by using Biot-Savart's law, image method and 2D FEA(2 Dimensional Finite Element Analysis) considering the stress condition of HTS. Moreover, the analysis is verified by comparison with experimental results. And also this paper presents the advanced model by using 3D FEA, in which flux density at armature is calculated in 5kVA class HTSG.

  • PDF

Improvement of Field Uniformity in a Reverberation Chamber with Various Numbers of a 2D CRD (2D CRD 수에 따른 전자파 잔향실 내의 필드 균일성 개선)

  • Kim, Jin-Bok;Rhee, Joong-Geun;Kim, Jung-Hoon;Rhee, Eu-Gene
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.4
    • /
    • pp.18-24
    • /
    • 2010
  • This paper presents the improvement of the field uniformity in a reverberation chamber which can be substitute an anechoic chamber for the electromagnetic interference (EMI) and immunity test. Nowadays, there are many EMI issues due to the increasing use of wireless local area network (LAN), digital multimedia broadcasting (DMB), and mobile internet. With this reason, this paper studied the field characteristics in a reverberation chamber for 2.3 GHz band. In this paper, the finite difference time domain (FDTD) method is used to analyze the field characteristics in a reverberation chamber. To improve the field uniformity in the reverberation chamber, this paper adopted a 2D cubical residue diffuser (CRD) with varying the disposition and number of CRD. For each case, the tolerance and standard deviation of the electric field strength are evaluated. In comparison with the reverberation chamber without any CRD, the reverberation chamber with two CRDs showed improved results; 1.98 dB improvement in standard deviation and 3.6 dB improvement in tolerance.

B1+ Comparison for Different RF Coils at 7 T MRI (7 T MRI에서의 다양한 RF 코일에 대한 B1+ 비교)

  • Kim, Hong-Joon;Yoo, Hyoung-Suk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.8
    • /
    • pp.1010-1013
    • /
    • 2012
  • This paper demonstrates the use of the convex optimization to localize the transverse magnetic $B_1^+$ field in regions of interest for recently proposed multi-sectioned alternating impedance coils and the traditional transmission line coil. An approach based on different axial slices to identical RF coils except upper stripline structure is investigated. Electromagnetic simulation results are compared for RF coils and discussed in detail at 7.0 T.

Effect of a Magnetic Field on the Solute Distribution of Czochralski Single Crystal Growth (초크랄스키 단결정 성장에서 자기장이 용질분포에 미치는 영향)

  • Kim, Moo Gewi;Suh, Jeong Se
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.3
    • /
    • pp.388-397
    • /
    • 1999
  • Numerical simulations are carried out for the magnetic Czochralski single crystal growth system. It Is shown that a magnetic field significantly suppresses the convective flow and as the strength of magnetic field becomes to be stronger, the heat transfer in the melt is dominated by conduction rather than convection. By imposing a cusp magnetic field, the growth interface shape becomes convex toward the melt. When the axial magnetic field is imposed, there occurs an inversion of the interface shape with increase of the magnetic field strength. The oxygen concentration near the interface decreases with increasing cusp magnetic field strength while axial field causes an increase of an oxygen concentration at the central region and decrease of that at the edge of the crystal. The results show that the cusp magnetic field has advantages over an axial magnetic field In the radial uniformity of oxygen as well as in the additional degree of control.

Hysteresis Loss in a $Sm_1Ba_2Cu_3O_{7-\delta}$ Coated Conductor under Simultaneously Applied Field and Current with Phase Differences (위상차를 갖고 변화하는 자기장과 전류가 동시에 가해진 $Sm_1Ba_2Cu_3O_{7-\delta}$ Coated Conductor의 자기이력 손실)

  • Lee, Sang-Moo;Jung, Ye-Hyun;Kwak, Ki-Sung;Rhee, Joon-Kyu;Yoo, Jae-Un;Youm, Do-Jun;Kim, Ho-Sup;Ha, Hong-Soo;Oh, Sang-Soo
    • Progress in Superconductivity
    • /
    • v.10 no.2
    • /
    • pp.92-98
    • /
    • 2009
  • The magnetic field profiles near the surface of a $Sm_1Ba_2Cu_3O_{7-\delta}$ coated conductor(CC-tape) under magnetic field and current that were applied simultaneously with phase differences ${\phi}s$ were measured using scanning Hall probe method. Measurements were carried out along the elliptic load lines with $\phi=90^{\circ}\;and\;45^{\circ}$ for some $B_{peak},\;I_{peak}$ values. From the measured field profiles, sheet current density J(x, $B_a,\;I_a$) and magnetic flux density $B_0(x,\;B_a,\;I_a)$ profiles in the CC-tape were calculated. Using these J(x, $B_a,\;I_a$) and $B_0(x,\;B_a,\;I_a)$ profiles, we estimated the hysteresis energy loss Q in the CC-tape. The estimated Qs, together with our previous results for $\phi=0^{\circ}$ from [9], were compared with theoretical values based on Brandt's calculation.

  • PDF