• Title/Summary/Keyword: B-field

Search Result 5,105, Processing Time 0.033 seconds

Lorentz Force Density Distribution of a Current Carrying Superconducting Tape in a Perpendicular Magnetic Field

  • Yoo, J.;Kwak, K.;Rhee, J.;Park, C.;Youm, D.;Park, B.J.;Han, Y.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.4
    • /
    • pp.13-16
    • /
    • 2010
  • The Lorentz force distribution of a high $T_c$ superconducting tape with increasing transport currents in magnetic field ($H_a$) was visualized. The external magnetic field was applied normally to the coated conductor tape surface after zero-field cooling, and the transport current ($I_a$) was increased stepwise from 0 to 90 % of the values of the critical current ($I_c$ ($H_a$)) at applied filed, Ha. The field distribution (H(x)) near the sample surface across the tape width (2w) was measured using the scanning Hall probe method. Applying an inversion to the measured field distribution, we obtained the underlying current distribution (J(x)), from which the magnetic induction, B(x) was calculated with Biot-Savart law. Then Lorentz force per unit length was calculated using F(x)=J(x)${\times}$B(x), which appears to be very inhomogeneous along the tape width due to the complicated distributions of J(x) and B(x).

A Study of Magnetic Properties in $Fe_{73.9}Cu_{1.0}Nb_{3.5}Si_{14.0}B_{7.6}$ by Magnetic Annelaing

  • Kim, Eng-Chan;Kim, Jin-Eui;Nam, Hyo-Duk
    • Transactions on Electrical and Electronic Materials
    • /
    • v.1 no.3
    • /
    • pp.29-33
    • /
    • 2000
  • The crystallographic and high frequency characteristics of $Fe_{73.9}Cu_{1.0}Nb_{3.5}Si_{14.0}B_{7.6}$ soft magnetic alloys were investigated under magnetic field annealing, The crystallization fraction of annealed samples with longitudinal magnetic fields is higher than that of samples without magnetic field. When the transverse magnetic field is applied, the crystallization fraction does not increases but decreases until $500^{circ}C$. It is found that for samples, the saturation induction are all same with 1.3 T. The coercive field of as-cast samples is 1.03 A/cm, but in annealed samples it decrease from 0.56 to 0.1A/cm with increasing annealing temperature from 400 to $550^{circ}C$. The squareness of annealed samples under transverse magnetic field has a small value than that of both without field and with longitudinal field annealing. It is noted that the magnetic field annealing with transverse direction to amorphous $Fe_{73.9}Cu_{1.0}Nb_{3.5}Si_{14.0}B_{7.6}$ profoundly influenced on the Mossbauer spectra in contrast to that with longitudinal direction and without magnetic field.

  • PDF

ZORA DFT Calculation of $^{11}$B Electric Field Gradient Tensor for Lithium Borates

  • Woo, Ae-Ja;Wasylishen, Roderick E.
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.8 no.2
    • /
    • pp.70-76
    • /
    • 2004
  • ZORA-DFT calculations of $^{11}$B EFG (electric field gradient) tensors for lithium borates, LiB$_3O_5$ (LBO) and Li$_2B_4O_7$ (LTB), were performed. The calculated values of 11B quadrupole coupling constant and asymmetry parameter are in good agreement with the experimental values. The sign of the quadrupole coupling constant for the tetrahedral boron site was deduced from the distortion from the ideal tetrahedral symmetry.

  • PDF

Effect of Endurance Training on the Plasma Honocysteine and B Vitamin Levels in Male Adolescent Field Hockey Players (지구력 훈련이 혈중 호모시스테인과 비타민 B 수준에 미치는 영향 -남자 고등학생 필드하키선수를 대상으로-)

  • Kang Hae Sun;Lee Myung Chun;You Young Chae;Chang Namsoo
    • Journal of Nutrition and Health
    • /
    • v.37 no.10
    • /
    • pp.881-887
    • /
    • 2004
  • Elevated plasma homocysteine is an independent risk factor for the development of cardiovascular disease. Exercise is generally believed to reduce the plasma homocysteine levels and therefore, being beneficial for cardiovascular disease (CVD). However, there is a possibility that athletes undergoing strenuous training and competition which increase oxidative stress may suffer from increased plasma homocysteine levels. The purpose of this study was to investigate the influence of endurance training on the plasma concentrations of B vitamins and homocysteine in 23 male adolescent field hockey players. Data collection and blood sampling was performed during the training period and non-training period. Following the training period, significant changes in energy and vitamin B6 intakes were observed in these subjects. Plasma vitamin B2, pyridoxal phosphate (PLP) and homocysteine levels were significantly higher during the training period than non-training period, whereas no difference was observed in plasma folate and vitamin B12 levels. Positive correlation was observed between plasma folate and folic acid intakes. When energy, B vitamin intakes were adjusted there was a significant negative correlation between plasma homocysteine levels and plasma riboflavin, folate and vitamin B12 levels. In conclusion, it is suggested that athletes with oxidative stress by strenuous exercise may need B vitamins since riboflavin, folic acid and vitamin Bl2 were shown to be negatively correlated with plasma homocysteine in athletes during the training period.

3-Axial Isotropic Electric-Field Probe Design with Resistor-Loaded Short Dipole (저항 부하된 소형 다이폴을 이용한 3축 등방성 전기장 프로브 설계)

  • Moon, Sung-Won;Jang, Byung-Jun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.3
    • /
    • pp.246-249
    • /
    • 2017
  • In this paper, we designed the 3-axis isotropic electric-field measurement probe using resistor-loaded short dipole with lumped chip resistors. The designed probe shows good isotropic characteristics as well as wideband and low sensitivity. The isotropic characteristics of ${\pm}0.39dB$ from 100 kHz to the 3 GHz band were derived and the reception sensitivity was 0.1 V/m. The frequency response is within 3 dB of the whole section, especially ${\pm}1.3dB$ from 150 kHz to 3 GHz, which is superior to the conventional electric field probe with short dipoles.

Co-Fe-B 자왜변환기를 이용한 간섭계형 광섬유 자계센서의 동작특성

  • 이경식
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.474-479
    • /
    • 1993
  • An interferometric fiber-optic magnetic field sensor is constructed by bonding a Co-Fe-B metallic glass transducer developed here by the melt-spun method to a single mode fiber arm in the fiber Mach-Zehnder interferometer and is tested. The bias field for the peak ac-sensitivity was observed near 0.97 Oe and the minimum detectable magnetic field was 3.9${\times}10^{-5}$ Oe(rms)/${\sqrt{Hz}}$ a 3 kHz. The output of the ac field sensor becomes saturated near the input signal level of 1 Oe(rms). The Co- Fe-B transducer exhibits peak response near 500 Hz.

  • PDF

TiO2 Nano-doping Effect on Flux Pinning and Critical Current Density in an MgB2 Superconductor

  • Kang, J.H.;Park, J.S.;Lee, Y.P.;Prokhorov, V.G.
    • Journal of Magnetics
    • /
    • v.16 no.1
    • /
    • pp.15-18
    • /
    • 2011
  • We have studied the $TiO_2$ doping effects on the flux pinning behavior of an $MgB_2$ superconductor synthesized by the in-situ solid-state reaction. From the field-cooled and zero-field-cooled temperature dependences of magnetization, the reversible-irreversible transition of $TiO_2$-doped $MgB_2$ was determined in the H-T diagram (the temperature dependence of upper critical magnetic field and irreversibility line). For comparison, the similar measurements are also obtained from SiC-doped $MgB_2$. The critical current density was estimated from the width of hysteresis loops in the framework of Bean's model at different temperatures. The obtained results manifest that nano-scale $TiO_2$ inclusions served as effective pinning centers and lead to the enhanced upper critical field and critical current density. It was concluded that the grain boundary pinning mechanism was realized in a $TiO_2$-doped $MgB_2$ superconductor.

Design of Crisscrossed Double-Layer Birdcage Coil for Improving B1+ Field Homogeneity for Small-Animal Magnetic Resonance Imaging at 300 MHz

  • Seo, Jeung-Hoon;Han, Sang-Doc;Kim, Kyoung-Nam
    • Journal of Magnetics
    • /
    • v.20 no.3
    • /
    • pp.308-311
    • /
    • 2015
  • We design a crisscrossed double-layer birdcage (DLBC) coil by modifying the coil geometry of a standard single-layer BC (SLBC) coil to enhance the homogeneity of transmitting magnetic flux density ($B_1{^+}$) along the main magnetic field ($B_0$)-direction for small-animal magnetic resonance imaging (MRI) at 300 MHz. The performance assessment of the crisscrossed DLBC coil is conducted by computational analysis with the finite-difference time domain method (FDTD) and compared with SLBC coil in terms of the $B_1$ and the $B_1{^+}$ distribution. As per the computational calculation studies, the mean value in the two-dimensional $B_1{^+}$ map obtained at the mid-axial slice with the proposed DLBC coil is slightly lower than that obtained with the SLBC coil, but the $B_1{^+}$ value of the DLBC coil in the outermost plane (40 mm away from the central plane) shows improvements of 19.3% and 24.8% over the SLBC coil $B_1{^+}$ value when simulating a spherical phantom and realistic mouse body modeling. These simulation results indicate that, the $B_1{^+}$ homogeneity along the z-direction was improved by using DLBC configuration. Our approach enables $B_1{^+}$ homogeneity improvement along the zdirection, and it can also be applied to ultra-high field (UHF) MRI systems.

A Study on the Turbulent Characteristics of Rushton Turbine Mixer by Simultaneous Measurement of Velocity and Concentration field with Stereo-PIV/PLIF Technique (Stereo-PIV/LIF의 속도장과 농도장 동시측정 기법을 이용한 러쉬톤 교반기내 난류특성에 관한 연구)

  • Min, Young-Uk;Kim, Yun-Gi;Kim, Kyung-Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.3
    • /
    • pp.365-370
    • /
    • 2004
  • Simultaneous measurement with PLIF(Planar Laser-Induced Fluorescence) and Stereo-PIV(Stereo Particle Image Velocimetry) was performed to investigate the structural characteristics of flow field in Rushton Turbine Mixer. Instantaneous 3D velocity fields are measured by two 2K${\times}$2K CCD cameras focused on an object plane with the angular displacement methods while the concentration fields are obtained through the measurement of the fluorescence intensity of Rhodamine B tracer excited by the second pulse of Nd:Yag laser light. Image distortion due to the camera view-angle is compensated by a mapping function. Finally, the spatial structures of turbulent flow around Rushton turbine were identified by the calculation of synchronized data of the velocity field and concentration field.

Whole brain radiotherapy using four-field box technique with tilting baseplate for parotid gland sparing

  • Park, Jaehyeon;Yea, Ji Woon
    • Radiation Oncology Journal
    • /
    • v.37 no.1
    • /
    • pp.22-29
    • /
    • 2019
  • Purpose: The aim of this study is to evaluate the efficacy and feasibility of four-field box whole brain radiotherapy (FB-WBRT) with tilting baseplate by comparing bilateral WBRT (B-WBRT). Methods and Materials: Between March 2016 and September 2018, 20 patients with brain metastases underwent WBRT using the four-field box technique. WBRT is performed with a dose of 30 Gy in 10 fractions daily. Two computed tomography simulations per person were performed. One was in the traditional supine position for B-WBRT and the other by applying the tilting acrylic supine baseplate to elevate the head by 40° for FB-WBRT. The B-WBRT used the field-in-field technique, which is the most commonly used method in our institution. The FB-WBRT comprised anterior, posterior, and bilateral beams. A wedge was applied in anterior and posterior fields to compensate for skull convexity. Results: The average of Dmean of both parotid glands was 10.2 Gy (range, 3.8 to 17.8 Gy) in B-WBRT and 5.4 Gy (range, 2.0 to 11.7 Gy) in FB-WBRT (p < 0.05). Compared to B-WBRT, FB-WBRT reduced the mean dose of the right and left parotid glands from 10.1 Gy to 4.9 Gy and from 10.4 Gy to 5.8 Gy, respectively (p < 0.05). Further, V5, V10, V15, V20, and V25 for the parotid gland decreased significantly in FB-WBRT (p < 0.05). The Dmax and Dmean of lens decreased according to the dose-volume histogram. Conclusion: Compared to B-WBRT, FB-WBRT with a tilting baseplate is a simple and effective method that takes feature of noncoplanar beam to protect the parotid gland.