• Title/Summary/Keyword: B-field

Search Result 5,105, Processing Time 0.032 seconds

Analysis of Current Density Distribution and In Vitro Exposur System fot ELF Exposed Cell Experiments (ELF 전자파 피폭 세포실험을 위한 배양기의 전류밀도 분포 해석 및 In Vitro 노출장치 설계)

  • 김대근;정재승;안재목
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.1
    • /
    • pp.84-91
    • /
    • 2001
  • In in vitro cell experiments for the biological assessment of electromagnetic (EM) field, exposure system (ES) must be analyzed in terms of current density (J) and induced electric field intensity (E). Although in uniform B field, E and J in the sample medium are not distributed uniformly because of conductivity in sample dish. Thus, the precise estimation for E and J induced by uniform ELF within sample media is very important keys for successful in in vitro experiments. In this paper, we designed in vitro ELF ES with electromagnetic analysis using MATLAB simulator. Then we calculated from the measured B field to verify induced E & J distribution for random locations of cells within media in two cases of samples existence or not. ES with B field ranging from 0 to 20G consists of Helmholz coil and current generator based on the microprocessor. Also, we developed ELFES for each B field generation as uniform and non-uniform modes.

  • PDF

Biological Control and Plant-Growth Promotion by Bacillus Strains from Milk

  • Nautiyal Chandra Shekhar;Mehta Sangeeta;Singh Harikesh Bahadur
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.2
    • /
    • pp.184-192
    • /
    • 2006
  • Six-hundred bacterial strains from human milk and milk from Sahiwal cows, Holstein Friesian cows, and buffaloes were screened for their ability to suppress phytopathogenic fungi under in vitro conditions. A consortium of 3 strains, viz., Bacillus lentimorbus B-30486 (B-30486), B. subtilis B-30487 (B-30487), and B. lentimorbus B-30488 (B-30488), isolated from Sahiwal cow milk resulted in better biological control and plant-growth promotion than single-strain treatments. For commercial-scale production of a bioinoculant, the solid-state fermentation of sugarcane agro-industrial residues, i.e., molasses, press mud, and spent wash, using the consortium of B-30486, B-30487, and B-30488, resulted in a value-added product, useful for enhancing plant growth. The application of the consortium to sugarcane fields infested with Fusarium moniliforme and Colletotrichum falcatum resulted in a reduction of mortality and significantly higher (P=0.05) plant height, number of tillers, and cane girth when compared with the control. Furthermore, under field conditions, the treatment of sugarcane with the consortium resulted in significantly (P=0.05) greater plant growth compared with nonbacterized plants. Accordingly, this is the first report on the effective use of bacteria isolated from milk for biological control and enhancing plant growth under field conditions. Furthormore, a solid-state fermentation technology was developed that facilitates the economic utilization of agro-industrial residues for environmental conservation and improving plant and soil health.

The Effect of Magnetic Field on Enhancing the Anisotropy of Melt-spun Nd-Fe-Co(-Zr)-B Alloy (급속응고중 외부자장에 의한 Nd-Fe-Co(-Zr)-B계 합금의 자기이방성 향상)

  • Lee, U-Yeong;Choe, Seung-Deok;Yang, Chung-Jin
    • Journal of the Korean Magnetics Society
    • /
    • v.2 no.3
    • /
    • pp.233-238
    • /
    • 1992
  • Melt-spun $Nd_{14}Fe_{76}Co_4B_6$ and $Nd_{10.5}Fe_{79}Co_2Zr_{1.5}B_7$ ribbons were prepared under an externally applied magnetic field. Magnetic properties in terms of anisotropy were evaluated by discussing the effect of textured structure of the ribbon samples as well as its powders. About 32 % increase in $(B{\cdot}H)_{max}$ and 18.8 % increase in $B_r$ were observed along the perpendicular direction of the ribbon plane which is more prominent for the Nd-Fe-Co-Zr-B than for the Nd-Fe-Co-B alloy. The enhancement of magnetic anisotropy was monitored by measuring the anisotropy constant of each alloy as a function of quenching rate of the ribbon. It was found that for the melt-spun ribbon quenched at slow rate(less than 7 m/s) the magnetic field effect was overwhelmed by the heat gradient effect through the ribbon thickness while the field effect was prominent at intermediate quenching rate (more than 7~11 m/s). The reproducible maximum energy product, $(B{\cdot}H)_{max}$=16.4 MGOe can be obtained from the Nd-Fe-Co-Zr-B alloy.

  • PDF

The Magnetic Properties of Amorphous F$e_32Ni_36Cr_14P_12B_6$ (비정질 F$e_32Ni_36Cr_14P_12B_6$의 자기적 성질)

  • Kim, Jung-Gi
    • Korean Journal of Materials Research
    • /
    • v.2 no.4
    • /
    • pp.293-297
    • /
    • 1992
  • The magnetic properties of the amorphous Fe/sub 32/Ni/sub 36/Cr/sub 14/P/sub 12/B/sub 6/ has been studied by Mossbauer spectroscopy in the temperature range of 88-400K. The analysis of the spectrum of B8K, the magnetic hyperfine field and quadrupole splitting are found to be 140.5kOe and almost zero, which means that the magnetic hyperfine field is randomly oriented with respect to the principal axes of the electric field gradient, respectively. The values of quadrupole splitting in paramagnetic phase with Tc=280K are independent on the changes of temperature. Debye temperature is found to be about 288k from the analysis of recoilless fraction.

  • PDF

Enhanced Giant Magnetoelectric Effect in Laminate Composites of FeCuNbSiB/FeNi/PZT

  • Wen, Yumei;Wang, Dong;Li, Ping
    • Journal of Magnetics
    • /
    • v.16 no.4
    • /
    • pp.398-402
    • /
    • 2011
  • A novel laminate composite of FeCuNbSiB/FeNi /PZT is proposed, where FeCuNbSiB has a permeability of around 100000, which is much larger than that of FeNi. The high-permeability FeCuNbSiB was laminated with piezomagnetic FeNi rather than attached to its ends. It is expected that the effect produced by the high permeability will act on the whole of the piezomagnetic layer. While a FeNi layer was laminated with a FeCuNbSiB layer, the strong demagnetization produced by the latter was expected to be imposed on the FeNi layer as well as the applied fields. The distribution of applied fields was altered by the high-permeability material (both bias and ac field) and the field variation positively contributed to the ME effect in piezomagnetic/piezoelectric composites. Thus the ME voltage coefficient along with the field sensitivity were improved.

Preliminary Results of 7-Channel Insertional pTx Array Coil for 3T MRI

  • Ryu, Yeun Chul
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.238-243
    • /
    • 2017
  • In this research, we report the preliminary results of an insertional type parallel transmission (pTx) array that has 7-elements that are placed in the space above a patient table as a transmit (Tx) coil to give an RF transmission ($B_1{^+}$) field for the body object of a 3 Tesla (T) MRI system. In previous research, we have tried to compare the performances of different coil elements and array geometries for a pTx body image. Based on these results, we attempt to obtain a human image with the proposed pTx array. Through the simulation and experimental results, we introduce a possible structure of multi-channel Tx array and verify the utility of a multi-channel Tx body image using $B_1{^+}$ shimming. The insertional pTx array, combined with a receiver (Rx) array coil, provides an enhanced $B_1{^+}$ field homogeneity in a large ROI image as a result of $B_1{^+}$ shimming applied over the full body size object. Through this research, we hope to determine the usefulness of the proposed insertional type RF coil combination for 3 T body imaging.

A Synthesized Isotropic Pattern Antenna for Electromgnetic Environment Measurements (전자파환경 측정을 위한 합성 등방성 패턴 안테나)

  • 윤현보;최익권;임계재;백낙준;유희준
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.3 no.1
    • /
    • pp.20-27
    • /
    • 1992
  • A synthesized isotropic pattern antenna can be realized by arrangeing $\lambda$/ 2 dipole along each x, y, z axis. The sleeve type $\lambda$/ 2 dipole antenna is used as a basic element for a proper impedance matching at feeding point and minimum mutual coupling effect between each element at 820 MHz - 895 MHz band. The total electric field intensity radiated from the designed isotropic pattern antenna is drived from the magnetic vector potential which is produced by each sleeve $\lambda$/ 2 dipole in the far field. This total electric field intensity is inversely proportional only to distance $\gamma$from the origin of coordinates, and pattern factor variation is less than 2.1dB. The measured value of total electric field variation depending on pattern factor is less then 2.8dB, and the difference between the calculated and measured value is 0.7dB.

  • PDF

Oxygen Profiles and Precipitation Behavior in CZ Silicon Crystals Grown in A Transverse Magnetic Field (수평자장 하에서 성장된 CZ 실리콘 단결정의 산소 분포 및 석출거동)

  • Kim, Kyeong-Min;Choi, Kwang-Su;P. Smetana;T.H. Strudwick;Lee, Mun-Hui
    • Korean Journal of Materials Research
    • /
    • v.2 no.2
    • /
    • pp.119-125
    • /
    • 1992
  • Oxygen segregation in horizontal-magnetic-field-applied Czochralski (HMCZ) silicon crystals has been studied as a function of magnetic field strength (B) and crucible rotation rate (C). Along the axis of 57mm din. <100> crystals grown under B=2, 3, 4 kG and C=4-15rpm, the oxygen distribution was usually saw-tooth shaped and fluctuated unevenly. Compared to the conventional CZ method, this result seems to indicate that the horizontal magnetic field, at levels used in the present experiment, had a destabilizing influence on oxygen transport to the growth interface. On the other hand, as C increased, the oxygen fluctuation lessened, and [0] increased overall. At B=2 kG, an oxygen profile in a level of 27-36 ppma was achieved by a programmed ramp of C. Oxygen precipitation behavior of the HMCZ silicon during a simulated device manufacturing process was compared and found to be inferior to that of typical CZ silicon. The uneven oxygen profile in the as-grown state was identified as the major source of poor precipitation uniformity in the HMCZ silicon.

  • PDF

MRI Enhancement using Perovskite Material for B1 Field Control at 7T (7T MRI에서 B1 필드 조정을 위해 페로브스카이트 재료를 이용한 자기공명영상 향상)

  • Kim, Yong-Tae;Kim, Joo-Yeon;Baek, Hyeon-Man
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.565-573
    • /
    • 2021
  • The spatial distribution of electromagnetic fields in the human body can be adjusted by using high dielectric materials. This method has a complementary compared to other methods. However, it can be used as a powerful dielectric shimming tool in certain applications. It can be manufactured in a geometrically free shape and a pad manufactured according to the purpose can be applied without any change of the system. Especially in ultrahigh magnetic field (UHF) MRI, the clinical high dielectric pad used to increase the intensity of the transmit (B1+) and receive (B1-) fields, which has low sensitivity due to the high operating frequency, has great potential. In addition, there are few studies applied to UHF MRI. Therefore, in this study, a high dielectric material pad made of calcium titanate suspension was developed in the laboratory. And the signal increase of clinically useful images was confirmed in various protocols of UHF 7T MRI.

RIEMANNIAN SUBMANIFOLDS WITH CONCIRCULAR CANONICAL FIELD

  • Chen, Bang-Yen;Wei, Shihshu Walter
    • Bulletin of the Korean Mathematical Society
    • /
    • v.56 no.6
    • /
    • pp.1525-1537
    • /
    • 2019
  • Let ${\tilde{M}}$ be a Riemannian manifold equipped with a concircular vector field ${\tilde{X}}$ and M a submanifold (with its induced metric) of ${\tilde{M}}$. Denote by X the restriction of ${\tilde{X}}$ on M and by $X^T$ the tangential component of X, called the canonical field of M. In this article we study submanifolds of ${\tilde{M}}$ whose canonical field $X^T$ is also concircular. Several characterizations and classification results in this respect are obtained.