• Title/Summary/Keyword: B-Scan

Search Result 415, Processing Time 0.032 seconds

Resonution Enhancement of Ultrasonic B-Scan Images by Deconvolution (횡축 디콘벌루션에 의한 초음파 B 스캔 연상의 해상력 향상)

  • Jeong, Joon-Young;Chin, Young-Min;Woo, Kwang-Bang
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.445-449
    • /
    • 1988
  • Digital processing of measured data offers a powerful means to improve the resolution and quality of ultrasonic imaging. The present research demonstrates that filtering typical B-scan images using Wiener filter enhances lateral resolutions by more than 50 percent. The filter is operated using the measured signal amplitude across the transmitter beam and the beam with. It is optimized for low noise and high resolution By an empirical approach. This bethod for lateral filtering produces a very useful result for the line images with high interference by neighboring lines.

  • PDF

Lacrimal sac lymphoma: a case report

  • Ueathaweephol, Somtaporn;Wongwattana, Panuwat;Chanlalit, Waruttaporn;Trongwongsa, Therdkiat;Sutthinont, Sirilak
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.1
    • /
    • pp.43-47
    • /
    • 2022
  • Primary lymphoma originating from the lacrimal drainage system is a rare disease. Such lymphomas are mostly B-cell in origin and present nonspecific symptoms. The treatment of malignant lymphoma of the lacrimal drainage system is slightly different. We present the case of a 71-year-old woman with a painless mass below the medial canthus. Computed tomography (CT) scan of the orbit revealed a mass invading the right lacrimal sac. An incision biopsy was obtained, and the pathologic findings suggested a diagnosis of primary diffuse large B-cell lymphoma of the lacrimal sac. The patient was treated with chemotherapy and intrathecal methotrexate. After completing eight cycles of chemotherapy, the patient was followed up by a CT scan, which revealed nearly total resolution of an ill-defined enhancing mass. At the time of this case report writing, the patient is in complete remission at six months with no other complications.

H.264의 FMO Performance Evaluation and Comparison over Packet-Lossy Networks (패킷 손실이 발생하는 네트워크 환경에서의 H.264의 FMO 성능분석과 비교에 관한 연구)

  • Kim Won-Jung;Lim Hye-Sook;Yim Chang-Hoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.5C
    • /
    • pp.490-496
    • /
    • 2006
  • H.264 is the most recent video coding standard, containing improved error resilience tools than previous video compression schemes. This paper shows an analysis of the dependency of error concealment (EC) performance on the expected number of correctly received neighboring macroblock(MB)s for a lost MB, applying error concealment schemes to the raster scan mode that is used in the previous video coding standard and the flexible macroblock ordering (FMO) which is one of error-resilience tools in H.264. We also present simulation results and performance evaluation with various packet loss rates. Simulation results show that the FMO mode provides better EC performances of $1{\sim}9dB$ PSNR improvements compared to the raster scan mode because of larger expected number of correctly received neighboring MBs. The PSNR improvement by FMO mode becomes higher as the intra-frame period is larger and the packet loss rate is higher.

Improvement of an Identified Slot Sacn-Based Active RFID Tag Collection Algorithm (인식 슬롯 스캔 기반 능동형 RFID 태그 수집 알고리즘 개선)

  • Yoon, Won-Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.3
    • /
    • pp.199-206
    • /
    • 2013
  • This paper proposes a modified tag collection algorithm that improves the drawback of the identified slot scan-based tag collection algorithm presented in a previous paper to improve the tag collection performance in active RFID systems. The previous identified slot scan-based tag collection algorithm is optimized in situations where all the tags store the fixed size of data, so it could not result in a good performance improvement with tags having the variable size of data. The improved tag collection algorithm proposed in this paper first collects the slot size information required for the data transmission from each tag via the identified slot scan phase, and then performs the tag collection phase using the information, which resolves the problem of the previous identified slot scan-based tag collection algorithm. The simulation results for performance evaluation showed that the proposed tag collection algorithm resulted in the almost same tag collection performance as the previous algorithm when all the tags have the same size of data and led a large improvement of the tag collection performance in ISO/IEC 18000-7 unlike the previous algorithm when each tag has a random size of data.

A Clinical Study on Liver Scanning using Colloidal Radiogold and Liver Function in Cirrhosis of the Liver (간경변증(肝硬變症)에 있어서 교질형방사성금(膠質形放射性金)($^{198}Au$)을 사용(使用)한 간(肝)스켄과 간기능(肝機能)과의 관계(關係)에 관(關)한 임상연구(臨床硏究))

  • Koh, Chang-Soon;Rhee, Chong-Heon;Chang, Ko-Chang;Lee, Young;Min, Young-Eal;Hong, Changgi D.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.3 no.1
    • /
    • pp.59-67
    • /
    • 1969
  • Correlation between the blood clearance half time and findings of liver scan using the colloidal radiogold in patients of liver cirrhosis is observed through the scoring system, in which the more changes in size, shape and density in the liver scan, the more points are given (table 1). Results: 1) Within the increase in severity of hepatocellular dysfunction in liver cirrhosis, the degree and frequency of following changes in liver scan (done with colloidal radiogold) were increased in order. a) generalized hepatomegaly b) enlargement of the left lobe & reduction of the right lobe c) relatively increased radiodensity in the left lobe and 4) visualization of spleen. 2) Frequency of the normal scan in liver cirrhosis was $12{\pm}3.56%$, frequency of normal value in blood clearance half time of the radiogold was $5.0{\pm}2.34%$ and frequency of normal scan & normal blood clearance rate in liver cirrhosis was $3.6{\pm}2.06%$.

  • PDF

Design of S-Band Phased Array Antenna with High Isolation Using Broadside Coupled Split Ring Resonator

  • Hwang, Sungyoun;Lee, Bomson;Kim, Dong Hwan;Park, Joon Young
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.2
    • /
    • pp.108-116
    • /
    • 2018
  • In this paper, a method of designing a Vivaldi type phased array antenna (PAA) which operates at S-band (2.8-3.3 GHz) is presented. The presented antenna uses broadside coupled split ring resonators (BC-SRRs) for high isolation, wide field of view, and good active S-parameter characteristics. As an example, we design a $1{\times}8$ array antenna with various BC-SRR structures using theory and EM simulations. The antenna is fabricated and measured to verify the design. With the BC-SRR implemented between the two radiating elements, the isolation is shown to be enhanced by 6 dB, up to 23 dB. The scan angle is shown to be within ${\pm}53^{\circ}$ based on a -10 dB active reflection coefficient. The operation of the scan angle is possible within ${\pm}60^{\circ}$ with a little larger reflection coefficient (-7 dB to -8 dB). The proposed design with BC-SRRs is expected to be useful for PAA applications.

Microstructures and Mechanical Properties of Al-B4C Composites Fabricated by DED Process (DED 공정으로 제조된 Al-B4C 복합재의 미세조직 및 기계적 특성)

  • Yu-Jeong An;Ju-Yeon Han;Hyunjoo Choi;Se-Eun Shin
    • Journal of Powder Materials
    • /
    • v.30 no.3
    • /
    • pp.262-267
    • /
    • 2023
  • Boron carbide (B4C) is highly significant in the production of lightweight protective materials when added to aluminum owing to its exceptional mechanical properties. In this study, a method for fabricating Al-B4C composites using high-energy ball milling and directed energy deposition (DED) is presented. Al-4 wt.% B4C composites were fabricated under 21 different laser conditions to analyze the microstructure and mechanical properties at different values of laser power and scan speeds. The composites fabricated at a laser power of 600 W and the same scan speed exhibited the highest hardness and generated the fewest pores. In contrast, the composites fabricated at a laser power of 1000 W exhibited the lowest hardness and generated a significant number of large pores. This can be explained by the influence of the microstructure on the energy density at different values of laser power.

Print-Scan Resilient Curve Watermarking using B-Spline Curve Model and its 2D Mesh-Spectral Transform (B-스프라인 곡선 모델링 및 메시-스펙트럼 변환을 이용한 프린트-스캔에 강인한 곡선 워터마킹)

  • Kim, Ji-Young;Lee, Hae-Yeoun;Im, Dong-Hyuck;Ryu, Seung-Jin;Choi, Jung-Ho;Lee, Heung-Kyu
    • The KIPS Transactions:PartB
    • /
    • v.15B no.4
    • /
    • pp.307-314
    • /
    • 2008
  • This paper presents a new robust watermarking method for curves that uses informed-detection. To embed watermarks, the presented algorithm parameterizes a curve using the B-spline model and acquires the control points of the B-spline model. For these control points, 2D mesh are created by applying Delaunay triangulation and then the mesh spectral analysis is performed to calculate the mesh spectral coefficients where watermark messages are embedded in a spread spectrum way. The watermarked coefficients are inversely transformed to the coordinates of the control points and the watermarked curve is reconstructed by calculating B-spline model with the control points. To detect the embedded watermark, we apply curve matching algorithm using inflection points of curve. After curve registration, we calculate the difference between the original and watermarked mesh spectral coefficients with the same process for embedding. By calculating correlation coefficients between the detected and candidate watermark, we decide which watermark was embedded. The experimental results prove the proposed scheme is more robust than previous watermarking schemes against print-scan process as well as geometrical distortions.

$^{99m}Tc$-MDP Bone Scan in the Cases of Muscle Necrosis Associated with Acute Renal Failure (급성(急性) 신부전(腎不全)이 동반(同伴)된 근양사(筋壤死)에 있어서의 $^{99m}Tc$-MDP 골주사(骨走査))

  • Moon, H.B.;Han, J.S.;Kim, S.Y.;Cho, B.Y.;Lee, J.S.;Koh, C.S.;Cho, K.S.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.14 no.2
    • /
    • pp.61-66
    • /
    • 1980
  • We studied four patients with muscle necrosis associated with acute renal failure to evaluate the diagnostic value of the bone scan in this disease. The illness followed carbon monoxide poisoning in two patients, acute physical exertion in one and contaminated intramuscular injection in the other. Whole-body rectilinear bone scans using technetium 99m-methyldiphosphonate were done. In all patients, increased muscle labelling at the regions of suspected muscle injury was showed, and in one, it was after normalization of serum muscle enzyme levels. In one patient, the bone scan was rechecked 8 months later and showed no residual abnormality. Above all, the site and precise extent of muscle injury could be detected and the degree of muscle labelling seemed to correlate with the severy of muscle injury. These findings suggest that isotope scanning may be useful in the diagnosis of patients with acute muscle necrosis.

  • PDF