• Title/Summary/Keyword: B-H loop

Search Result 215, Processing Time 0.045 seconds

Core Loss Analysis of Non-oriented Electrical Steel Under Magnetic Induction Including Higher Harmonics

  • Cho, Chuhyun;Son, Derac;Cho, Youk
    • Journal of Magnetics
    • /
    • v.6 no.2
    • /
    • pp.66-69
    • /
    • 2001
  • The actual magnetic induction waveform of cores in electrical machines is not sinusoidal i.e. higher harmonics are always included. Thus the core loss in actual electrical machines is different from the core loss which is measured by the standard method, because the waveform of magnetic induction should be sinusoidal in the standard testing method. Core loss analysis under higher harmonic induction is always important in electric machine design. In this works we measured the core loss when a hysteresis loop has only one period of an ac minor loop of higher harmonic frequency, depending on the position of the ac minor loop of relative to the fundamental harmonic frequency. From this experiment, the core loss P(B/sub 0/f/sub 0/, B/sub h/, nf/sub 0/)) under a higher harmonic magnetic induction B/sub h/ could be expressed by the linear combination the core loss at fundamental harmonic frequency P/sub c/(B/sub 0/, f/sub 0/), the core loss of ac minor loop at zero induction region of the major hysteresis loop P/sub cL/ (B/sub h/, nf/sub 0/), and the core loss of an ac minor loop in the high induction region of the major hysteresis loop P/sub cH/ (B/sub h/, nf/sub 0/) i.e., P/sub c/, (B/sub 0/, f/sub 0/, B/sub h/, nf/sub 0/)=P/sub c/ (B/sub 0/, f/sub 0/,)+(n-1)[k₁(B/sub 0/) P/sub cL/ (B/sub h/, nf/sub 0/)+(1-k₁(B/sub 0/)) P/sub cH/ (B/sub h/, nf/sub 0/)]. This will be useful formula for electrical machine designers and one of effective methods to predict core loss including higher harmonic induction.

  • PDF

Major B-H Loop Measurement of Toroidal Shape Magnetic Powder Core (토로이드형 분말코어의 Major B-H Loop 측정)

  • Son, Derac
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.3
    • /
    • pp.76-80
    • /
    • 2014
  • Toroidal cores made of metallic powder requires large magnetic field strength up to few decade kA/m to obtain major hysteresis loop. To overcome thermal heat generation problem from large exciting current during measurement, we have employed a real time hysteresis loop tracer which can digitize and calculate B-H signals in personal computer as real time. For example, when we magnetize specimen at 10 Hz frequency, we could display hysteresis loops 10 times per second. Using the real time hysteresis loop tracer, we could measure major hysteresis loop of toroidal shape metallic powder core at maximum flux density or maximum magnetic field strength to be measured within 5 second not to significant increasement of specimen temperature due to the heat dissipation from coil windings. For the constructed hysteresis loop tracer, we could measure hysteresis loop at magnetic field strength higher than 50 kA/m for the toroidal shape specimen.

B-H Loop Measurement of a High Tensile Steel Plate (사각판재형 강재의 자기특성측정)

  • Kim, Young-Hak;Kim, Ki-Chan;Shin, Kwang-Ho;Kim, Hwi-Seok;Yoon, Kwan-Seob;Yang, Chang-Seob
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.3
    • /
    • pp.94-99
    • /
    • 2010
  • Minor B-H loop measurement for a rectangular high tensile steel was obtained by using Labview. A ferrite cores of high permeance with primary and secondary windings on the steel plate were used to form a closed loop of magnetic flux. To compensate errors due to an extremely small gap between a pair of ferrite core, and between the ferrite core and the rectangular high tensile steel, quadratic function of least square method was used. Also a 3D FEM magnetic analysis tool was used to measure H and B of the steel. B-H loop of the high tensile steel plate can be measured up to 520 A/m of a magnetic field and 0.15 T of a magnetic flux density.

The study on effects of porosity, strain and grain size on B-H Hysteresis Ioop (기공율, 응력 및 입자 크기가 B-H Hysteresis loop 특성에 미치는 영향 연구)

  • 김성재;정명득;백종규
    • Journal of the Korean Magnetics Society
    • /
    • v.4 no.2
    • /
    • pp.89-93
    • /
    • 1994
  • Effects of density, inner-stress, and grain size on B-H hysteresis loop properties of Mg-ferrite were investigated. As the sintered bulk density increase, coercive force($H_c$) decreasand squareness ratio increase. Coercive force was very dependent on inner-stress in sintered body, so coercive force increase from 1.95[Oe] to 4.35[Oe] when inner stress present in bulk, however, the squareness ratio was almost not changed Coercive force and squareness ratio were independent on grain size of sintered body which is between 6-11[$\mu\textrm{m}$]

  • PDF

Stress Analysis of IPS Lower bracket

  • Lee, J.M.;Park, K.N.;Chi, D.Y.;Park, S.K.;Sim, B.S.;Lee, H.H.;Ahn, S.H.;Lee, C.Y.;Kim, H.R.
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2005.10a
    • /
    • pp.703-704
    • /
    • 2005
  • PDF

Prediction of Core Loss Including Higher Harmonic Inductions Using Two Symmetrical AC Minor Loops

  • Son, Derac
    • Journal of Magnetics
    • /
    • v.8 no.2
    • /
    • pp.93-97
    • /
    • 2003
  • For the induction motor and inverter type motor design, prediction and analysis of core loss including higher harmonics have been studied. In this work, we have generated two symmetrical ac minor loop in the fundamental hysteresis loop whose positions are zero induction region and saturation induction region, and we could pre-dict core loss including higher harmonics inductions. using the following modified superposition principle; $P_c(B_0,f_0,B_h,nf_0)=P_c(B_0,f_0)+(n-1)[K_1(B_0)P_{cL}(B_h,nf_0)+(1-k_1(B_0))P_{cH}(B_h,nf_0)].$Using this equation we could also analyze core losses including higher harmonic induction under different maximum magnetic induction, different amplitude of higher harmonic induction with different harmonic frequencies.

Improvement of the Optimum pH of Aspergillus niger Xylanase towards an Alkaline pH by Site-Directed Mutagenesis

  • Li, Fei;Xie, Jingcong;Zhang, Xuesong;Zhao, Linguo
    • Journal of Microbiology and Biotechnology
    • /
    • v.25 no.1
    • /
    • pp.11-17
    • /
    • 2015
  • In an attempt to shift the optimal pH of the xylanase B (XynB) from Aspergillus niger towards alkalinity, target mutation sites were selected by alignment between Aspergillus niger xylanase B and other xylanases that have alkalophilic pH optima that highlight charged residues in the eight-residues-longer loop in the alkalophilic xylanase. Multiple engineered XynB mutants were created by site-directed mutagenesis with substitutions Q164K and Q164K+D117N. The variant XynB-117 had the highest optimum pH (at 5.5), which corresponded to a basic 0.5 pH unit shift when compared with the wild-type enzyme. However, the optimal pH of the XynB-164 mutation was not changed, similar to the wild type. These results suggest that the residues at positions 164 and 117 in the eight-residues-longer loop and the cleft's edge are important in determining the pH optima of XynB from Aspergillus niger.

Design and control of Single Loop Output Voltage Controller for 3 Phase PWM Inverter (3상 PWM 인버터의 단일제어루프 전압제어기의 설계 및 제어)

  • Gang B.H.;Gho J.S.;Cho J.S.;Choe G.H.;Kwak C.H.;Kim J.H,
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.496-500
    • /
    • 2001
  • There are two ways in the output voltage control method in PWM inverter. One is the double loop voltage control composed of inner current control loop and outer voltage control loop. Because it shows fast response and low steady state error, utilized in many application. The Other is single loop voltage control method composed of voltage control loop only. It's characteristics shows lower performance in case of high output impedance than double loop voltage control. But in low output impedance, it shows good control performance in all load range than double loop control. In this paper, single loop voltage control rule and gain was developed analytically, and these were verified through computer simulation and experiment.

  • PDF

Molecular Dissection of the Interaction between hBLT2 and the G Protein Alpha Subunits

  • Vukoti, Krishna Moorthy;Lee, Won-Kyu;Kim, Ho-Jun;Kim, Ick-Young;Yang, Eun-Gyeong;Lee, Cheol-Ju;Yu, Yeon-Gyu
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.6
    • /
    • pp.1005-1009
    • /
    • 2007
  • Leukotriene B4 (LTB4) is a potent chemoattractant for leukocytes and considered to be an inflammatory mediator. Human BLT2 (hBLT2) is a low-affinity G-protein coupled receptor for LTB4 and mediates pertussis toxin-sensitive chemotactic cell movement. Here, we dissected the interaction between hBLT2 and G-protein alpha subunits using GST fusion proteins containing intracellular regions of hBLT2 and various Gα protein including Gα i1, Gα i2, Gα i3, Gα s1, Gα o1, and Gα z. Among the tested Gα subunits, Gα i3 showed the highest binding to the third intracellular loop region of hBLT2 with a dissociation constant (KD) of 5.0 × 10?6 M. These results suggest that Gα i3 has the highest affinity to hBLT2, and the third intracellular loop region of hBLT2 is the major component for the interaction with Gα i3.

Printed Type Half-wavelength Small Loop Antenna (프린트형 반파장 소형 루프 안테나)

  • Ryu, Hong-Kyun;Woo, Jong-Myung
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.245-248
    • /
    • 2005
  • In this paper, small sized half-wavelength circular loop antenna which attached beneath a visor of helmet is designed and fabricated at the resonant frequency of 449MHz. To reduce the size of the antenna, double series-shorted stubs are inserted inside the loop for practical use of a vacant space of loop inside. Also, It is designed for the printed type to install the helmet easily. The size of antenna on helmet is reduced to 87.75%(diameter : 70mm, height :.36mm) compare with general type antenna(diameter : 200mm height 101mm). The return loss, -10dB bandwidth and gain are -13.2dB, 17.6MHz(3.9%), and -1.78dBd. And, radiation pattern is omni-directional pattern at H-plane. Therefore, it can be seen that the half-wavelength circular loop antenna using double series-shorted stubs is proper structure for the miniaturization and the installed antenna of the helmet.

  • PDF