• Title/Summary/Keyword: B Coefficient

Search Result 2,873, Processing Time 0.036 seconds

Improvement of Physicochemical Properties and Turfgrass Growth by Root Zone Mixture of Soil Amendment 'Profile' (토양개량제 '프로파일'의 혼합에 따른 토양의 물리화학성 및 한지형 잔디의 생육 개선)

  • Kim, Young-Sun;Lim, Hye-Jung;Ham, Soun-Kyu;Lee, Geung-Joo
    • Weed & Turfgrass Science
    • /
    • v.6 no.3
    • /
    • pp.262-271
    • /
    • 2017
  • This study was conducted to evaluate incorporation ratio of soil amendment 'Profile' to improve soil physicochemical properties and turfgrass growth. The soil amendment was added 0 (sand only), 3, 5, 7, and 10% to USGA Green-spec green sand soil. As incorporated with more 'Profile' amendment, soil electrical conductivity (EC), cation exchangeable capacity (CEC), capillary porosity and total porosity of root zone were increased than those of control, while bulk density and hydraulic conductivity decreased. Turfgrass index and clipping yield of creeping bentgrass grown in sand soil incorporated with 7% 'Profile' were improved than those of control. Correlation coefficient of turf color index and incorporation ratio of the soil amendment 'Profile' was found to show significantly positive correlation. These results indicated that application of the soil amendment 'Profile' to sand soil in golf course green improved turfgrass growth and quality by increasing CEC and porosity of root zone.

Absorption of soil residual azoxystrobin to lettuce (상추 재배토양 중 잔류 Azoxystrobin의 작물흡수)

  • Kim, Min-Gi;Hwang, Kyu-Won;Hwang, Eun-Jung;Yoo, Soo-Cheol;Moon, Joon-Kwan
    • Journal of Applied Biological Chemistry
    • /
    • v.60 no.4
    • /
    • pp.343-349
    • /
    • 2017
  • This study was conducted to investigate the residual level and the amount of transfer to lettuce grown in field condition treated with the 5-methyl-1,2,4-triazolo[3,4-b][1,3]benzothiazole (Azoxystrobin). The field trials on lettuce were carried out at two different green houses located in Gwangju (Field 1) and Yongin (Field 2). Soil and lettuce samples were collected at different days after soil treatment of azoxystrobin with two different concentrations, respectively. Average recoveries for azoxystrobin ranged from 86.9 to 113.6% from soil and lettuce with the variation coefficient of 0.1-4.6%. The initial concentrations of azoxystrobin in Gwangju soil were 9.20, 11.00 mg/kg and decreased to 1.36, 2.70 mg/kg at 43 DAT (days after treatment) in field 1, while 1.06, 2.23 mg/kg decreased to 0.20 and 0.67 mg/kg at 36 DAT in field 2, respectively. The half-lives of azoxystrobin were about 19.4 and 23.3 days for the low and high concentration of azoxystrobin treated soils in field 1 and 11.5 and 17.8 days in field 2 soils, respectively. Residue levels of azoxystrobin in lettuce were not detected in filed 1 and field 2 soils, respectively.

Genetic Distance and Heterosis Degree Among the Developed Waxy Corn Lines (찰옥수수 육성계통간 유전적 거리와 잡종강세 정도)

  • Lee, Moon-Sub;Yang, Jae-Hyeon;Lim, Seung-Bin;Lee, Hee-Bong
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.60 no.4
    • /
    • pp.464-469
    • /
    • 2015
  • This study was carried out to find relationships of genetic distance and heterosis expression degree in the developed CNU waxy corn lines. The used material were developed in Corn Breeding Laboratory, Coll. of Agri. & Life Sci., CNU. Total 10 primers used for SSR maker analysis. In genetic distance, the used lines divided into four groups; A group has two lines, B group has one line, C group has ten lines and D group has eleven lines, respectively. Among used lines, CNU427 and CNU588 were very closed as a 74, while CNU451 and CNU429 were remote as a 40 inbred coefficient, respectively. While heterosis degree were very variable not only hybrids but also cross parents. Average heterosis of most cross-parent was high in plant height, ear height, flowering day and ear length. Especially, CNU H09-23 hybrid was high as 79.4% than other hybrids. Here, we gained the fact has closely relationship between genetic distance and heterosis.

Changes in Physicochemical and Microbiological Properties in Low-Temperature and Long-Term Fermented Kimchi during Fermentation (묵은 김치 제조과정에서의 이화학적 및 미생물학적 특성변화)

  • Yoo, Maeng-Ja;Kim, Hyung-Ryang;Chung, Hee-Jong
    • Journal of the Korean Society of Food Culture
    • /
    • v.16 no.5
    • /
    • pp.431-441
    • /
    • 2001
  • To develop the low-temperature and long-term fermented kimchi, kimchi was prepared according to the recipe of a specific ratio of major and minor ingredients and adjusted its salinity to 3.7%. Prepared kimchi fermented at $15{\pm}1^{\circ}C$ for 24 hours and transferred and fermented in a refrigerator only used to make low-temperature and long-term fermented kimchi at $-1{\pm}1^{\circ}C$ for 30 weeks. During 30 weeks of fermentation the changes in physicochemical and microbiological properties of low-temperature and long-term fermented kimchi were studied. The initial pH of 6.47 decrease gradually and dropped to pH 4.0 after 14 weeks of fermentation, and then it maintained at same level. Acidity increased to 0.49% on 2 weeks of fermentation and kept at 0.47 $\sim$0.50% during 2 to 30 weeks fermentation. Salinity was slightly increased at early stage and started to decrease on 4 weeks of fermentation, and then it did not change. The change of reducing sugar content was closely related to the trend of pH change with a very high correlation coefficient(r =0.912). Lactic acid, citric acid, malic acid, succinic acid and acetic acid were major organic acids contained in low-temperature and long-term fermented kimchi. Vitamin C content decreased at initial stage of fermentation and then slightly increased up to the maximum of 22.3 mg% on 8weeks of fermentation. In color measurement, L value continued to increase during the fermentation and reached at the highest of 55.45 on 22 weeks of fermentation, and a and b values of 3.62 and 4.54 also increased to 31.26 and 37.32 on 30 weeks of fermentation, respectively. Total microbial count increased slowly from beginning and was the highest on 4 weeks of fermentation, and then began to decrease slowly. Count of Lactobacillus spp. was highest after 6weeks, but count of Lactobacillus spp. was highest on 2 weeks of fermentation, and then both showed a slow decrease. Yeast count wasn't increased until 4 weeks of fermentation and then increased rapidly to get the highest on 10 weeks of fermentation.

  • PDF

Properties of aggregation and spatial distribution of fish in the South Sea of Korea using hydroacoustic data (수산음향기법의 주파수에 따른 남해안의 어류의 군집 및 공간분포 특징)

  • HWANG, Kangseok;PARK, Jeong-Ho;LEE, Jeonghoon;CHA, Hyung-Kee;PARK, Junseong;KANG, Myounghee
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.52 no.4
    • /
    • pp.325-338
    • /
    • 2016
  • Properties of aggregation and spatial distribution of fish were examined based on three lines in the South Sea of Korea using three frequencies (18, 38, and 120 kHz) of a scientific echosounder. The vertical distribution of fish was displayed using acoustic biomass namely nautical area scattering coefficient (NASC). As a result, at 120 kHz high NASC showed from water surface to 20 meters in deep while at 18 and 38 kHz very high NASC presented in 70 ~ 90 meters in depth, especially at line 3. Among three lines, the line 2 had lowest NASC. The horizontal distribution of fish using three frequencies together exhibited high NASC between the eastern South Sea and center of South Sea. In especial, NASC ($801{\sim}1,920m^2/n{\cdot}mile^2$) was observed along coastal waters from Busan to Tongyeong, Geoje, and Namhae. In regard with the property of aggregation of fish schools, the volume back-scattering strength ($S_V$) of three lines presented close each other, however, the range of $S_V$ in the line 2 was shortest (-53.5 ~ -43.4 dB). The average distributional depth was deep in the order of L3 ($32.8{\pm}9.0m$), L1 ($45.2{\pm}9.5m$), L2 ($49.7{\pm}5.6m$). The average altitude was high in the order of L3 ($13.4{\pm}10.3m$), L1 ($17.0{\pm}12.6m$), L2 ($56.7{\pm}5.6m$). The average length, thickness, and area were large in the order of L1, L3, and L2. This means that small sized fish schools were distributed near water surface in the line 2 while relatively large and similar sized fish aggregations between line 1 and line 3 appeared however, fish schools at line 3 had lower distributional depth and smaller compared to those at line 1. Acoustic data were visualized for demonstrating the entire circumstances of survey area. Additionally, there was no correlation between acoustic and trawl results.

The Effects of Barley Tea Concentration and Atomizing Pressure on the Atomization with Two Fluid Nozzle Spray Gun (이류식(二流式) 노즐에서 보리차 추출액(抽出液)의 농도(濃度) 및 분무(噴霧) 압력(壓力)이 분무화(噴霧化)에 미치는 영향(影響))

  • Lee, Jeong-Cheol;Chun, Jae-Kun
    • Korean Journal of Food Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.342-347
    • /
    • 1983
  • The effects of barley tea concentration and atomizing air pressure on the size, homogeneity and distribution of the sprayed droplets were investigated. An equation relating mean diameter (${\overline{D}}$) with the concentration where the coefficient a and b were determined empirically. As the operating air pressure was increased, the mean diameter of the droplets decreased and finally reached the limiting mean diameter, $36{\mu}m$ at 15.7% barley tea concentration. The homogeneity of the droplets increased with the operating air pressure, increase and it was decreased steadily as the soluble solid concentration increased up to 20% and markedly over 20% at every operating air pressure. The distribution ($P_D$) of sprayed droplets related with the droplet size as the following exponential equation; $P_D$ = e 1nD + f where e and f are empirical constants.

  • PDF

The Heat Pump Application to the Food Concentration (열 펌프의 식품 농축에의 이용 연구)

  • Park, Noh-Hyun;Kim, Byeong-Sam;Kang, Tong-Sam;Shin, Dong-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.486-491
    • /
    • 1987
  • The performance and applicability to food concentration of heat pump were investigated. During heating the water of spa from $43^{\circ}C$ to $51^{\circ}C$, COP's of heat pump (R-12, 150 HP) were 4.03 at heating part and 3.5 at cooling part. And, the efficiency of compressor (${\alpha}$) was 0.477 While the city water was heated to $39^{\circ}C$ by heat pump (R-22, 10 HP), its COP's were 3.0 at heating part and 1.87 at cooling part. During concentrations sucrose solution by centrifugal evaporator (ALFA-LAVAL CO, CTIB) with heat pump, heat capacity for condensating water vapor was required greater 15% than the latent heat for concentrating and then the overall heat transfer coefficient was $1196\;Kcal/m^{2}.\;h.\;^{\circ}C$. When low temperature concentration ($30-35^{\circ}C$, 28-40 Torr) of garlic extract was carried out by the water of $60^{\circ}C$ and $15^{\circ}C$ adjusted by heat pump, the ratio of heat capacity for concentrating vs. that for condensating of water vapor was 0.961.

  • PDF

The Effect of an Oral Health Program by B School Dental Clinic in Anyang City (안양시 B초등학교 학교구강보건실 운영사업이 학생구강건강에 미치는 효과)

  • Ahn, Yong-Soon;Jang, Jong-Hwa;Lee, Yong-Soo
    • Journal of dental hygiene science
    • /
    • v.8 no.4
    • /
    • pp.375-380
    • /
    • 2008
  • This study evaluated the effect of an school-based oral health program supplied to primary school children in Anyang city. This program included oral health education, pit and fissure sealing, fluoride mouth rinsing and professional tooth brushing. The numbers of the subjects were 311 children in the program participant group and 165 children in the control group which were not in the program. Data were analyzed with t-test, one way ANOVA and pearson's correlation coefficient using SPSS WIN 12.0 program. In attitude, behavior of oral hygiene, participant group was better than the control group. In case of the perceived oral health, satisfaction of oral health, need oral treatment there was no significant difference between the two groups. These results suggest that school children can learn the good attitude and behaviors and oral health promotion can be achived from the oral health program run by shool dental clinic.

  • PDF

Study on SCS CN Estimation and Flood Flow Characteristics According to the Classification Criteria of Hydrologic Soil Groups (수문학적 토양군의 분류기준에 따른 SCS CN 및 유출변화특성에 관한 연구)

  • Ahn, Seung-Seop;Park, Ro-Sam;Ko, Soo-Hyun;Song, In-Ryeol
    • Journal of Environmental Science International
    • /
    • v.15 no.8
    • /
    • pp.775-784
    • /
    • 2006
  • In this study, CN value was estimated by using detailed soil map and land cover characteristic against upper basin of Kumho watermark located on the upper basin of Kumho river and the hydrologic morphological characteristic factors were extracted from the basin by using the DEM document. Also the runoff analysis was conducted by the WMS model in order to study how the assumed CN value affects the runoff characteristic. First of all, as a result of studying the soil type in this study area, mostly D type soil was Identified by the application of the 1987 classification criteria. However, by that in 1995, B type soil and C type soil were distributed more widely in that area. When CN value was classified by the 1995 classification criteria, it was estimated lower than in 1987, as a result of comparing the estimated CNs by those standars. Also it was assumed that CN value was underestimated when the plan for Geum-ho river maintenance was drawn up. As a result of the analysis of runoff characteristic, the pattern of generation of the classification criteria of soil groups appeared to be similar, but in the case of the application of the classification criteria in 1995, the peak rate of runoff was found to be smaller on the whole than in the case of the application of the classification criteria in 1987. Also when the statistical data such as the prediction errors, the mean squared errors, the coefficient of determination and other data emerging from the analysis, was looked over in total, it seemed appropriate to apply the 1995 classification criteria when hydrological soil classification group was applied. As the result of this study, however, the difference of the result of the statistical dat was somewhat small. In future study, it is necessary to follow up evidence about soil application On many more watersheds and in heavy rain.

AERODYNAMIC EFFECT OF ROOF-FAIRING SYSTEM ON A HEAVY-DUTY TRUCK

  • KIM C. H.;YOUN C. B.
    • International Journal of Automotive Technology
    • /
    • v.6 no.3
    • /
    • pp.221-227
    • /
    • 2005
  • Aim of this study is to investigate an aerodynamic effect of a drag-reducing device on a heavy-duty truck. The vehicle experiences two different kinds of aerodynamic forces such as drag and uplifting force (or downward force) as it is traveling straight forward at constant speed. The drag force on a vehicle may cause an increase of the rate of fuel consumption and driving instability. The rolling resistance of the vehicle may be increased as result of the negative uplifting or downward force on the vehicle. A device named roof-fairing system has been applied to examine the reduction of aerodynamic drag force on a heavy-duty truck. As for a engineering design information, the drag-reducing system should be studied theoretically and experimentally for the best efficiency of the device. Four different types of roof-fairing model were considered in this study to investigate the aerodynamic effect on a model truck. The drag and downward force generated by vehicle has been obtained from numerical calculation conducted in this study. The forces produced on four fairing models considered in this study has been compared each other to evaluate the best fairing model in terms of aerodynamic performance. The result shows that the roof-fairing mounted truck has bigger negative uplifting or downward force than that of non-mounted truck in all speed ranges, and drag force on roof-fairing mounted truck has smaller than that of non-mounted truck. The drag coefficient $(C_D)$ of the roof-fairing mounted truck (Model-3) is reduced up to $41.3\%$ than that of non-mounted trucks (Model-1). A downward force generated by a roof-fairing mounted on a truck is linearly proportional to the rolling resistance force. Therefore, the negative lifting force on a heavy-duty truck is another important factor in aerodynamic design parameter and should be considered in the design of a drag-reducing device of a tractor-trailer. According to the numerical result obtained from present study, the drag force produced by the model-3 has the smallest of all in all speed ranges and has reasonable downward force. The smaller drag force on model-3 with 2/3h in height may results of smallest thickness of boundary layer generated on the topside of the container and the lowest intensity of turbulent kinetic energy occurs at the rear side of the container.