• Title/Summary/Keyword: B Coefficient

Search Result 2,873, Processing Time 0.032 seconds

COEFFICIENT ESTIMATES FOR A SUBCLASS OF ANALYTIC BI-UNIVALENT FUNCTIONS

  • Adegani, Ebrahim Analouei;Bulut, Serap;Zireh, Ahmad
    • Bulletin of the Korean Mathematical Society
    • /
    • v.55 no.2
    • /
    • pp.405-413
    • /
    • 2018
  • In this work, we use the Faber polynomial expansions to find upper bounds for the coefficients of analytic bi-univalent functions in subclass $\Sigma({\tau},{\gamma},{\varphi})$ which is defined by subordination conditions in the open unit disk ${\mathbb{U}}$. In certain cases, our estimates improve some of those existing coefficient bounds.

A Study on the Prediction of Chloride Diffusion Coefficient in Concrete for mediocre apply (범용적 적용을 위한 콘크리트의 염화물 확산계수 예측에 관한 연구)

  • Kim, Dong-Seok;Yoo, Jae-Kang;Kim, Young-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.189-192
    • /
    • 2006
  • This study was performed to suggest the mediocre prediction equation of chloride diffusion coefficient which is used to estimate the service life of marine concrete, in order to provide the useful data for concrete mix design of marine concrete. As a result, the mediocre prediction equation of chloride diffusion coefficient which set W/B and mineral admixture replacement ratio as parameters was presented by performing the multivariate non linear regression analysis.

  • PDF

Calculation of Cronbach's Alpha Coefficient, Generalizability Index (GI), and Dependability Index (DI) in the Model Types of Survey Design (서베이 설계 모형별 Cronbach's Alpha 계수와 GI, DI 산출방안)

  • Choi, Sung-Woon
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.04a
    • /
    • pp.701-705
    • /
    • 2011
  • The paper reviews Cronbaha's coefficient to measure a single source of error. On the contrary to classical measurement theory, the generalizability study can be used in the social survey design to calculate Generalizability Index (GI) and Dependability Index (DI) for measuring multiple sources of errors of behavior evaluation. The study proposes application guidelines to implement R:($A{\times}B$) mixed models that are composed of random factor and fixed factor.

  • PDF

A Study on the Noise Correction Factor in Apartment Complex (공동주택에서의 소음보정계수에 관한 연구)

  • Lee, Nae Hyun;Sunwoo, Young;Park, Young Min;Park, Sun Hwan;Cho, Il-Hyoung
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.5
    • /
    • pp.247-254
    • /
    • 2005
  • Road traffic noise has increasing broader effects on urban areas as well as rural areas because of rapidly increasing traffic volume and newly-constructed roads. 10 sites in building development areas were selected and the noise level were measured by the apartment floors and by the various block plans of apartment complex. Analysis result, about correction factor, in the case of right angle arrangement, apply - 2.5dB(A). In the case of apartment house correlation of each floor apply 1st floors 0dB(A), 2st floors 1.2dB(A), 3st floors 2.1dB(A), 4st floors 2.6dB(A), 5st floors 2.7dB(A), 6st floors 2.7dB(A), 7st floors 2.4dB(A), 8st floors 2.0dB(A), 9st floors 1.6dB(A), 10st floors 1.1dB(A), 13st floors 0.2dB(A), 15st floors 0.5dB(A). The level of road traffic noise in the arrangement construction of right angle was about 3.0dB(A) at N-4 point and 2.1dB(A) at N-6 point lower than that of a plan figure, respectively. The results suggested that application of correction coefficient obtained by the apartment floor and by the arrangement construction can be improved in road traffic noise. The results suggested that application of correction coefficient obtained by the apartment floor and by the arrangement construction can be improved in road traffic noise.

Measuring Apparatus for Convective Heat Transfer Coefficient of Nanofluids Using a Thermistor Temperature Sensor (더미스터 온도센서를 이용한 나노유체의 대류열전달계수 측정 장치)

  • Lee, Shin Pyo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.2
    • /
    • pp.103-110
    • /
    • 2016
  • Fine wires made from platinum have been used as sensors to evaluate the convection performance of nanofluids. However, the wire sensor is difficult to handle due to its fragility. Additionally, an unrealistic convective heat transfer coefficient (h) is obtained if a rigorous calibration process combined with precision equipment is not used for measurement. This paper proposes a new evaluation apparatus for h of nanofluids that uses a thermistor sensor instead of the platinum wire. The working principles are also explained in detail. Validation experiments for pure engine oil comparing h from the two sensors confirmed numerous practical benefits of the thermistor. The proposed system can be used as a useful tool to justify the adoption of developed nanofluids.

A Lattice-Based Monte Carlo Evaluation of Canada Deuterium Uranium-6 Safety Parameters

  • Kim, Yonghee;Hartanto, Donny;Kim, Woosong
    • Nuclear Engineering and Technology
    • /
    • v.48 no.3
    • /
    • pp.642-649
    • /
    • 2016
  • Important safety parameters such as the fuel temperature coefficient (FTC) and the power coefficient of reactivity (PCR) of the CANada Deuterium Uranium (CANDU-6) reactor have been evaluated using the Monte Carlo method. For accurate analysis of the parameters, the Doppler broadening rejection correction scheme was implemented in the MCNPX code to account for the thermal motion of the heavy uranium-238 nucleus in the neutron-U scattering reactions. In this work, a standard fuel lattice has been modeled and the fuel is depleted using MCNPX. The FTC value is evaluated for several burnup points including the mid-burnup representing a near-equilibrium core. The Doppler effect has been evaluated using several cross-section libraries such as ENDF/B-VI.8, ENDF/B-VII.0, JEFF-3.1.1, and JENDL-4.0. The PCR value is also evaluated at mid-burnup conditions to characterize the safety features of an equilibrium CANDU-6 reactor. To improve the reliability of the Monte Carlo calculations, we considered a huge number of neutron histories in this work and the standard deviation of the k-infinity values is only 0.5-1 pcm.

Simulation of Three-Dimensional Turbulent Flows around an Ahmed Body-Evaluation of Finite Differencing Schemes- (Ahmed body 주위의 3차원 난류유동 해석-유한차분도식의 평가-)

  • Myeong, Hyeon-Guk;Park, Hui-Gyeong;Jin, Eun-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.11
    • /
    • pp.3589-3597
    • /
    • 1996
  • The Reynolds-averaged Navier-Stokes equations with the equations of the k-.epsilon. turbulence model are solved numerically in a general curvilinear system for a three-dimensional turbulent flow around an Ahmed body. The simulation is especially aimed at the evaluation of three finite differencing schemes for the convection term, which include the upwind differencing scheme(UDS), the second order upwind differencing scheme(SOU scheme) and the QUICK scheme. The drag coefficient, the velocity and pressure fields are found to be changed considerably with the adopted finite differencing schemes. It is clearly demonstrated that the large difference between computation and experiment in the drag coefficient is due to relatively high predicted values of pressure drag from both front part and vertical rear end base. The results also show that the simulation with the QUICK or SOU scheme predicts fairly well the flow field and gives more accurate drag coefficient than other finite differencing scheme.

Film Cooling from Two Rows of Holes with Opposite Orientation Angles(II) -Blowing Ratio Effect- (반대방향의 방향각을 갖는 2열 분사구조의 막냉각 특성(II) -분사비의 영향-)

  • Ahn, Joon;Jung, In-Sung;Lee, Joon-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.8
    • /
    • pp.1131-1139
    • /
    • 2001
  • Experimental results are presented, which describe the effect of blowing ratio on film cooling from two rows of holes with opposite orientation angles. The inclination angle is fixed at 35°, and the orientation angles are set to be 45°for the downstream row, and -45°for the upstream row. The studied blowing ratios are 0.5, 1.0 and 2.0. The boundary layer temperature distributions are measured using thermocouple at two downstream locations. Detailed adiabatic film cooling effectiveness and heat transfer coefficient distributions are measured with TLC(Thermochromic Liquid Crystal). The adiabatic film cooling effectiveness and heat transfer coefficient distributions are discussed in connection with the injectant behaviors inferred from the boundary layer temperature distributions. Film cooling performance, represented by heat flux is evaluated from the adiabatic film cooling effectiveness and heat transfer coefficient data. The results show that the investigated geometry provides improved film cooling performance at the high blowing ratios of 1.0 and 2.0.

Evaluations of the Acoustics Characteristics of Cellulose Absorbers (셀룰로오즈 흡음재의 음향적 특성 평가)

  • Yeon, Joon-Oh;Kim, Kyoung-Woo;Yang, Kwan-Seop
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.5
    • /
    • pp.456-462
    • /
    • 2013
  • Eco-friendly material applied to building would be one of the materials which is must developed for global environmental conservation and reduction of carbon dioxide. For development of eco-friendly material, a cellulose absorber has been developed with waste paper through adjustment of various mix proportions. The developed cellulose absorber has been tested for its acoustic properties such as absorption coefficient and dynamic stiffness. The absorption coefficient was evaluated by developing six samples and using impedance tube and reverberation chamber. As a result of the evaluation, 0.64(NRC) was secured in absorption coefficient and 4.7 $MN/m^3$ was indicated in dynamic stiffness. Also, for practical use of developed absorbers as inner heartwood in drywall, comparison test of sound reduction index was performed with existing glass wool absorbers and constructed drywall of gypsum board. The results have shown 55 dB(Rw) of sound reduction index in glass-wool wall and 46 dB(Rw) in cellulose.