• Title/Summary/Keyword: B/R mode

Search Result 240, Processing Time 0.022 seconds

Ductile Fracture Behaviour of SA 533B Pressure Vessel Steel Under Mixed Mode (I/II) Loading (혼합 모드(I/II) 하중에 의한 SA533B 압력용기강의 연성파괴 특성에 관한 연구)

  • O, Dong-Jun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.11
    • /
    • pp.1829-1834
    • /
    • 2001
  • The aim of this study is to investigate the ductile fracture behavior under mixed mode (I/II) loading using SA533B pressure vessel steel. Anti-symmetric 4-point (AS4P) bonding tests were performed to obtain the J-R curves under two different mixed mode (I/II) loadings. In addition, the fractographic examination of fracture surfaces was carried out to compare with those of pure Mode I and Mode II. In conclusions, the J-R curves under Mixed Mode (I/II) loading were located between those of Mode I and Mode II loadings. When the mixture ratio of mixed mode (I/II) loading was high, the J-R currie of mixed mode (I/II) loading approached that of pure mode I loading after some amount of crack propagation. In contrast with the above fact, if the mixture ratio was low, the J-R curve looked after that of pure mode II loading. The fractographic evidences such as the shape of dimples under different loading conditions supported these conclusions.

Ductile Fracture Behavior of AS4P Under Mixed Mode (I/II) Loading

  • Oh, Dong-Joon
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.476-484
    • /
    • 2002
  • The aim of this study is to investigate the ductile fracture behavior under mixed mode (I/II) loading using SA533B pressure vessel steel. Anti-symmetric 4-point (AS4P) bending tests were performed to obtain the J-R curves under two different mixed mode (I/II) loadings. In addition, finite element analysis using Rousselier Ductile Damage Theory was carried out to predict the J-R curves under mixed mode (I/II) loadings. In conclusions, the J-R curves under. Mixed Mode (I/II) loading were located between those of Mode I and Mode II loading. When the mixity of mixed mode (I/II) loading was high, the J-R curve of mixed mode (I/II) loading approached that of pure mode I loading after some amount of crack propagation. In contrast with the above fact, if the mixity was low, the J-R curve took after that of pure mode II loading. Finally, it was found that the predicted J-R curves made a good agreement with the test data through the tuning procedures of $\beta$ values at the different mixed mode (I/II) loading.

High Power Cavity Type Tunable Filter Using Switch for 1.5 GHz Band (Switch를 이용한 1.5 GHz 대역 고출력 Cavity 기반 Tunable Filter)

  • Ahn, Sehoon;Lee, Minho;Park, Jongcheol;Jeong, Gyetaek
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • In this paper, the tunable filter based on high power cavity using mechanical switch for 1.5 GHz band is presented. The LPF is inserted to eliminate the spurious wave, coupler is embeded to extract the output power, and then the tunable filter system is configured using mechanical switch. The LPF obtains attenuation over 40 dB between 4 GHz and 12.75 GHz, Coupler is satisfied with coupling value 40 dB and coupling isolation over 55 dB. The tunable filter system using mechanical switch obtains insertion loss 0.88 dB at bypass mode between 1,495.9 MHz and 1,510. 9 MHz, 3.29 dB at fil mode between 1,495.9 MHz and 1,500.9 MHz. It is also satisfied with output power of 132 W at the center frequency 1,498.4 MHz, and switching time below 10 ms.

A 0.13-μm CMOS RF Tx/Rx Switch for Wideband Applications

  • Kim, Jeong-Yeon;Kim, Chang-Wan
    • Journal of electromagnetic engineering and science
    • /
    • v.8 no.3
    • /
    • pp.96-99
    • /
    • 2008
  • This paper describes a $0.13-{\mu}m$ CMOS RF switch for $3{\sim}5$ GHz UWB band(mode 1). It can improve isolation characteristics between ports by using deep n-well RF devices while their source and body terminals are separated. From the measurement results, the proposed T/R switch is comparative to the on-wafer probing measurement results of the series-shunt T/R switches. When the proposed T/R switch operates as Tx mode, measured insertion loss from Tx to output port is less than 1.5 dB and isolation between Tx and Rx is more than 27 dB for $3{\sim}5$ GHz. Return loss for the Tx port is more than -10 dB and input P1dB is +10 dBm.

3-Port Circulator for X-Band Radar (X-Band 레이더를 위한 3-포트 서큘레이터)

  • Yoon, Sung-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.2
    • /
    • pp.355-362
    • /
    • 2015
  • In this study, we have fabricated 9.385[GHz] circulator that is composed of WR112 waveguide and Ferrite for X-band radar. For designing Ferrite, B/R mode(Below Resonance mode) was used and calculated the condition of 120 degree rotation of the electric field in Ferrite and calculated internal DC magnetic field and external DC magnetic field. Also, dielectric materials of the same shape with Ferrite was filled between two Ferrite for improving the performance of the circulator, including impedance matching, bandwidth, quality factor, insertion loss. To obtain optimum shape of the Ferrite and dielectric material, we used CST MWS. Simulation result of the circulator is that 1.02 : 1 VSWR, -40dB isolation, 0.2dB insertion loss and measurement result is that 1.03 : 1, -38dB, 1.2dB at 9.385[GHz]. We can get good agreement at isolation and VSWR, but insertion loss was 1 dB great than simulation result.

Evaluation of shade guide using digital shade analysis system (색조 선택 시스템을 이용한 shade guide의 색조 분석)

  • Lee, Seung-Taek;Lee, Jong-Hyuk;Shin, Soo-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.1-11
    • /
    • 2009
  • Statement of problem: There are two methods of color choice for the esthetic restoration. One is visual shade matching which draws a comparison between shade guide and teeth in dentist's own eye and the other is using a digital shade analysis system recently introduced. Although the visual shade matching has a lot of problems, decision of color by this visual shade matching and the ways of expression for the decided color are still applicable to clinical dentistry. Purpose: This study is designed to investigate shade guides used in the dental clinics and laboratories have the same value using ShadeEye-$NCC^{(R)}$ dental chroma meter (Shofu Inc., Kyoto, Japan) using shade guide are evaluated. Material and methods: At the first experiment, eight Vita Lumin Vacuum shade guides (Vident Inc., California, USA) were collected from the dental clinics. A1 and B1 shade tabs are chosen and the colors are analyzed five times each in both tooth and porcelain modes by digital shade analysis system, ShadeEye-$NCC^{(R)}$. In the second experiment, twelve Vita shade guides using practically in the dental clinics and laboratories were collected and also A1 and B1 shade tabs are chosen and the colors of A1 and B1 are analyzed one time each in both tooth and porcelain modes by ShadeEye-$NCC^{(R)}$. Results and conclusion: There were significant differences among eight shade guides in terms of shade (chroma), value and hue in both of A1 and B1 (P<.05). Shade guides using in present both dental clinics and laboratories did not show significant differences, except A1 in the porcelain mode, it showed significant differences (P<.05) in the shade even though the shade tab has the same name.

Ductile Fracture Behaviour of SPS Specimen Under Pure Mode II Loading (순수 모드 II하중 하에서의 SPS 시험편의 연성파괴 특성에 관한 연구)

  • O, Dong-Jun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.2
    • /
    • pp.289-295
    • /
    • 2001
  • The aim of this study is to investigate the ductile fracture behaviour under pure Mode II loading using A533B pressure vessel steel. Single punch shear(SPS) test was performed to obtain the J-R curve under pure Mode II loading which was compared with that of the Model I loading. Simulation using Rousellier Ductile Damage Theory(RDDT) was carried out with 4-node quadrilateral element(L(sub)c=0.25mm). For the crack advance, the failed element removal technique was adopted with a $\beta$ criterion. Through the $\beta$ value tuning-up procedures, $\beta$(sub)crit(sup)II was determined as 1.5 in contrast with $\beta$(sub)crit(sup)I=5.5. In conclusion, it was found that the J-R curve under Mode II loading was located at lower part than that under Mode I loading obtained from the previous study and that the $\beta$ values strongly depended on the loading type. In addition, the predicted result using RDDT showed a good agreement with the SPS experimental one under pure Mode II loading.

Heating and Cooling Performance Characteristics of a Water-to-Water Heat Pump with R452B Refrigerant (R452B 냉매 적용 물대물 지열원 히트펌프 유닛의 냉난방 운전 성능 특성)

  • Choi, Youn Sung;Kang, Hee Jeong;Kim, Eun Oh
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.13 no.4
    • /
    • pp.14-20
    • /
    • 2017
  • Refrigerant having high global warming potentials will be phased out due to environmental protection issues. R410A has been widely used in geothermal heat pump. However, it has a little high GWP by 2088 value. One of the recommended substitute for R410A refrigerant is R452B which having a GWP by 698 value. In this paper, the heating and cooling performance of the water-to-water geothermal heat pump unit with R452B was experimentally investigated. The performance of the heat pump adopting R452B was also compared with the system applying R410A. The heating and cooling capacity of R452B heat pump system showed a slightly lower values within 2% comparing with R410A system. However, the R452B system's coefficient of performance was enhanced by 5.2% and 13.7% at heating and cooling mode, respectively.

Development of OCB mode with impulsive driving scheme for improving moving picture quality

  • Kim, J.L.;Lee, C.H.;Park, S.Y.;Yoo, S.W.;Oh, J.H.;Lee, S.H.;Chai, C.C.;Park, C.W.;Ban, B.S.;Ahn, S.H.;Hong, M.P.;Chung, K.H.;Lim, S.K.;Kim, K.H.;Souk, J.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1049-1052
    • /
    • 2004
  • In general, contrary to the CRTs with impulsive emission, liquid crystal displays have motion artifacts such as blurring. ghost image, decrease of dynamic CR(contrast ratio), and stroboscopic motion due to hold type driving method. In this paper, to improve motion picture quality of LCDs. impulsive driving method of black data insertion was applied to the OCB mode which is well known for its fast LC response time and wide viewing angle properties. Subject evaluation was carried out with CRT, TN, SIPS(Super IPS). and impulsive driving OCB. Moving picture image quality near CRT was obtained in impulsive OCB driving mode

  • PDF

A Single-Chip, Multichannel Combined R2MFC/DTMF/CCT Receiver Using Digital Signal Processor (DSP 칩을 이용한 다중채널 R2MFC/DTMF/CCT 겸용 수신기)

  • 김덕환;이형호;김대영
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.10
    • /
    • pp.21-31
    • /
    • 1994
  • This paper describes the multichannel combined R2MFC/DTMF/CCT reciver which provides a signaling service functions for call processing control in digital switching system. Using the TMS320C25 DSP chip, we have implemented multi-function receriver shich processes 8 channels of R2MFC, DTMF, and CCT signals simultaneously. In order to increase the channel multiplicity of the combined receiver. R2MFC and CCT receiver were employed by discrete Fourier transform(DFT) method using Goertzel algorithm, and DTMFreceiver was employ by infinite impulse reponse(IIR) filtering method using 4KHz subsampling technique. The combined receiver has 4 function modes for each channel such as R2MFC, DTMF, CCT, and Idle modes. The function mode of each channel may be selected at any time by single-chip micro-controller(.mu.C). Hence, the number of channels assigned for each function mode can be adjusted dynamically according to the signaling traffic variations. From the experimental test results using the test-bed, it has been proved that the combined receiver statisfies all receiver satisfies all receiver specifications, and provides good channel multiplicity and performance, Therefore, it may give a great improvement than existing receiver in cost, reliability, availability, and serviceability.

  • PDF