• 제목/요약/키워드: Axial-Flow Fans

검색결과 67건 처리시간 0.024초

공기호흡형 고분자연료전지의 운전특성에 대한 연구 (The Operating Characteristics of Air-Breathing Type PEFCs)

  • 손영준;임성대;박구곤;김경연;김민진;이원용
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.44-46
    • /
    • 2008
  • Air-breathing polymer electrolyte membrane fuel cells (PEMFC) are highly promising particularly for small-power applications up to tens watts class. A distinctive feature of the air-breathing PEMFC is its simple system configuration in which axial fans operate for dual purposes, supplying both oxidant and coolant in a single manner. In the present study, a nominal 80W air-breathing PEMFC system is developed and investigated to determine the optimal operating strategy through parametric studies (i.e., reactant humidity, and fanblowing flow rate). The cell voltage distributions are examined as a function of time to evaluate the system performance under various operating conditions.

  • PDF

석탄 화력발전소 송풍기 맥동감시장치 운전을 위한 제어로직 개발 (Development of Control Logic for Operation of Fan Stall Warning Equipment Used in Coal-Thermal Power Plant)

  • 노용기;조현섭;장성환
    • 한국산학기술학회논문지
    • /
    • 제7권5호
    • /
    • pp.837-846
    • /
    • 2006
  • 본 논문에서는 석탄 화력발전소(500[MW]) 보일러의 통풍계통에 적용되는 축류형 송풍기가 정상 운정 중 맥동과 같은 특수한 현상이 발생하게 되어 비정상적으로 운전함으로써 날개를 파손시키게 된다. 이러한 비정상 운전을 방지하기 위해 기존의 맥동 감시 장치에 본 연구에서 제안하는 제어 로직을 적용한 시스템에 대해 현장 실험을 통한 신뢰성 평가를 하였다.

  • PDF

대단면 석회석 광산 갱도 내 국부선풍기 승압력 및 통기효과 비교 연구 (A Comparative Study on the Auxiliary Fan Pressure and the Ventilation Efficiency in Large-opening Limestone Mine Airways)

  • 박동준;강현호;이창우
    • 터널과지하공간
    • /
    • 제27권1호
    • /
    • pp.1-11
    • /
    • 2017
  • 국내 지하 석회석 광산은 대부분 대단면 갱도로 개발되고 있으며 갱내통기는 주요 선풍기에 의한 통기방식보다는 자연통기 및 국부통기에 의존하고 있다. 국부통기는 국부선풍기와 풍관을 이용한 급배기 통기방식을 적용하고 있으나 대단면 갱도 특성과 갱내 굴진 운반장비의 디젤화에 따라 소요통기량이 대폭 증대하여 통기의 효율 및 경제성 확보가 주요과제로 대두되고 있다. 본 연구에서는 대단면 갱내 작업장 국부통기를 위한 선풍기 용량 최적화를 위하여 축류식 및 프로펠러 선풍기를 개발하여 갱내 승압력 및 통기효과를 비교 분석함을 목적으로 한다.

CFD를 이용한 선풍기 날개의 스태킹 라인 최적 설계 (Design optimization of the staking line for an electric fan blade using CFD)

  • 박승환;류민형;조이상;조진수
    • 한국항공우주학회지
    • /
    • 제42권11호
    • /
    • pp.903-910
    • /
    • 2014
  • 선풍기는 유도 전동기에 의해 구동되는 축류형 날개를 가진 기계이다. 본 연구에서는 기본 설계된 선풍기의 날개를 바탕으로 스태킹 라인의 최적 설계를 통해 선풍기의 성능 향상을 목표로 하였다. 전산 해석을 위해 상용 툴인 Ansys 사(社)의 CFX 14.5를 이용하였고, 난류 모델은 k-${\omega}$ SST 를 사용하였다. 설계 변수는 스윕 각과 기울기 각으로 설정하였고, 유량과 토크를 목적함수로 설정하여 스태킹 라인의 최적화를 수행하였다. 최적화 결과 풍량이 증가하였고, 토크가 감소함을 확인 하였다. 최적화된 모델과 기본 모델은 KS C 9301을 이용하여 측정되었으며, 전산 해석 결과를 검증하였다.

대평판 글라스 이송용 공기 부상 이송장치의 개발 (Development of the Air Floating Conveyor System for the Large Glass Sheet)

  • 이태걸;유진식;정효재;김종형;김준현
    • 한국생산제조학회지
    • /
    • 제22권4호
    • /
    • pp.635-642
    • /
    • 2013
  • We have prepared a DEMO conveyor device for conveying a large 8G class glass sheet using ahorizontal air-cushion system. This device consists of the body frame and the driving frame that are combined to realize a frame for conveying glass without any contact.The driving frame comprises an air flotation table (bed), drive roller supported at both ends, and ASU. Part of the ASU serves to control the airflow as the chamber consists of a porous pad and fan. Fiber filters replace the porous pad and axial fans serve as an air compressor. In addition, to determine the appropriate glass levitation from the air table, this study examined the design specifications of the applied filter (discharge speed of HEPA and ULPA filters, and flow rate) as well as the height of the and the proper supporting roller height (14mm). Then, after adjusting the position of the ASU and the number of ASUs required to configure the UNIT air floating C/V, we analyzed the height and flatness of the glass and derived the appropriate layout (1140-mm distance between ASUs).

설비공학 분야의 최근 연구 동향 : 2009년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2009)

  • 한화택;이대영;김서영;최종민;백용규;권영철
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.492-507
    • /
    • 2010
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2009. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery and piping, and new and renewable energy. Various topics were covered in the field of general thermal and fluid flow such as an expander, a capillary tube, the flow of micro-channel water blocks, the friction and anti-wear characteristics of nano oils with mixtures of refrigerant oils, etc. Research issues mainly focused on the design of micro-pumps and fans, the heat resistance reliability of axial smoke exhaust fans, and hood systems in the field of fluid machinery and piping. Studies on ground water sources were executed concerning two well type geothermal heat pumps and multi-heat pumps in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included the heat transfer in thermoelectric cooling systems, refrigerants, evaporators, dryers, desiccant rotors. In the area of industrial heat exchangers, researches on high temperature ceramic heat exchangers, plate heat exchangers, frosting on fins of heat exchangers were performed. (3) In the field of refrigeration, papers were presented on alternative refrigerants, system improvements, and the utilization of various energy sources. Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and $CO_2$ were studied. Efforts to improve the performance of refrigeration systems were made applying various ideas of suction line heat exchangers, subcooling bypass lines and gas injection systems. Studies on heat pump systems using unutilized energy sources such as river water, underground water, and waste heat were also reported. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. In the area of cogeneration systems, papers on energy and economic analysis, LCC analysis and cost estimating were reported. Studies on ventilation and heat recovery systems introduced the effect on fire and smoke control, and energy reduction. Papers on district cooling and heating systems dealt with design capacity evaluation, application plan and field application. Also, the maintenance and management of building service equipments were presented for HVAC systems. (5) In the field of architectural environment, various studies were carried to improve indoor air quality and to analyze the heat load characteristics of buildings by energy simulation. These studies helped to understand the physics related to building load characteristics and to improve the quality of architectural environment where human beings reside in.

수동공기공급형 고분자 전해질 연료전지 스택에서의 냉각특성에 대한 전산해석 연구 (Numerical Study on the Cooling Characteristics of a Passive-Type PEMFC Stack)

  • 이재혁;김보성;이용택;김용찬
    • 대한기계학회논문집B
    • /
    • 제34권8호
    • /
    • pp.767-774
    • /
    • 2010
  • 수동공기공급형 고분자 전해질 연료전지는 팬을 이용하여 주변의 공기를 스택에 공급한다. 공급된 공기는 연료로 쓰이는 동시에 스택의 냉각에도 사용된다. 이러한 방식은 시스템에서 가습기, 공기 압축기, 냉각수 설비를 제거할 수 있어서 시스템을 단순화 시키고 경량화 시킬 수 있는 반면 냉각성능은 기존의 냉각수를 이용하는 방식에 비하여 떨어진다. 따라서 시스템의 신뢰성 확보를 위하여 최적의 냉각 성능을 낼 수 있도록 스택을 설계하는 것이 중요하다. 본 연구에서는 고분자 전해질 연료전지 스택의 냉각성능 향상을 위하여 다양한 채널 형상, 공기극의 유량분포, 외부 대류열전달계수의 변화가 스택의 온도분포에 미치는 영향에 대한 전산해석을 수행하였다. 그 결과, 채널의 rib이 두꺼운 경우에 냉각성능이 가장 뛰어났으며 유량을 중앙부에 집중시킨 경우에 고온집중 현상이 감소하였다.