• Title/Summary/Keyword: Axial velocity

Search Result 751, Processing Time 0.027 seconds

Impact response of steel-concrete composite panels: Experiments and FE analyses

  • Zhao, Weiyi;Guo, Quanquan;Dou, Xuqiang;Zhou, Yao;Ye, Yinghua
    • Steel and Composite Structures
    • /
    • v.26 no.3
    • /
    • pp.255-263
    • /
    • 2018
  • A steel-concrete composite (SC) panel typically consists of two steel faceplates and a plain concrete core. This paper investigated the impact response of SC panels through drop hammer tests and numerical simulations. The influence of the drop height, faceplate thickness, and axial compressive preload was studied. Experimental results showed that the deformation of SC panels under impact consists of local indentation and overall bending. The resistance of the panel significantly decreased after the local failure occurred. A three-dimensional finite element model was established to simulate the response of SC panels under low-velocity impact, in which the axial preload could be considered reasonably. The predicted displacements and impact force were in good agreement with the experimental results. Based on the validated model, a parametric study was conducted to further discuss the effect of the axial compressive preload.

Effect of Axial Spacing between the Components on the Performance of a Counter Rotating Turbine

  • Subbarao, Rayapati;Govardhan, Mukka
    • International Journal of Fluid Machinery and Systems
    • /
    • v.6 no.4
    • /
    • pp.170-176
    • /
    • 2013
  • Counter Rotating Turbine (CRT) is an axial turbine with a nozzle followed by a rotor and another rotor that rotates in the opposite direction of the first one. Axial spacing between blade rows plays major role in its performance. Present work involves computationally studying the performance and flow field of CRT with axial spacing of 10, 30 and 70% for different mass flow rates. The turbine components are modeled for all the three spacing. Velocity, pressure, entropy and Mach number distributions across turbine stage are analyzed. Effect of spacing on losses and performance in case of stage, Rotor1 and Rotor2 are elaborated. Results confirm that an optimum axial spacing between turbine components can be obtained for the improved performance of CRT.

Enumeration of axial rotation

  • Yoon, Yong-San
    • Advances in biomechanics and applications
    • /
    • v.1 no.2
    • /
    • pp.85-93
    • /
    • 2014
  • In this paper, two procedures of enumerating the axial rotation are proposed using the unit sphere of the spherical rotation coordinate system specifying 3D rotation. If the trajectory of the movement is known, the integration of the axial component of the angular velocity plus the geometric effect equal to the enclosed area subtended by the geodesic path on the surface of the unit sphere. If the postures of the initial and final positions are known, the axial rotation is determined by the angular difference from the parallel transport along the geodesic path. The path dependency of the axial rotation of the three dimensional rigid body motion is due to the geometric effect corresponding to the closed loop discontinuity. Firstly, the closed loop discontinuity is examined for the infinitesimal region. The general closed loop discontinuity can be evaluated by the summation of those discontinuities of the infinitesimal regions forming the whole loop. This general loop discontinuity is equal to the surface area enclosed by the closed loop on the surface of the unit sphere. Using this quantification of the closed loop discontinuity of the axial rotation, the geometric effect is determined in enumerating the axial rotation. As an example, the axial rotation of the arm by the Codman's movement is evaluated, which other methods of enumerating the axial rotations failed.

Development of a Dual Axial Gyroscope with Piezoelectric Ceramics (압전세라믹을 이용한 2축형 회전센서 개발)

  • Ryoo, Hye-Ok;Lee, Young-Jin;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.6
    • /
    • pp.61-67
    • /
    • 1997
  • Piezoelectric gyroscopes are the devices to measure angular rotational velocity of a system with respect to an inertial frame of reference means of the Coriolis principle. Most of current piezoelectric gyroscopes detect rotational velocity about a single axis of rotation. This paper describes development of a new dual axial gyroscope made out of the piezoelectric ceramic, PZT, which can overcome the limitation of the current single axial type. The validity of the new structure is checked through finite element analysis. Based on the design, an experimental sample of the sensor is fabricated and its performance is discussed in comparison with the theoretical expectation. The resutls show that the present gyroscope is capable of measuring the rotational velocity over two orthogonal axes simultaneously with good enough sensitivity and distinction between the two axial components of the rotation.

  • PDF

Numerical and experimental study on the pressure dorp of axial-flow cyclone in the air handling unit (공기조화기 장착용 축상유입식 싸이클론의 압력손실에 대한 수치해석 및 실험적 연구)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Youngmin;Kim, Se-Young;Kim, Myeoung-Joon;Kim, Hojoong;Kim, Taesung
    • Particle and aerosol research
    • /
    • v.5 no.2
    • /
    • pp.37-43
    • /
    • 2009
  • Particulate matter (PM) is one of the major indoor air pollutants especially in the subway station in Korea. In order to remove PM in the subway station, several kinds of PM removal system such as roll-filter, auto-washable air filter, demister, and electrostatic precipitator are used in the air handling unit (AHU) of subway stations. However, those systems are prone to operation and maintenance problems since the filter-regeneration unit consisting of electrical or water jet parts might malfunction due to the high load of particulates unless the filter medium is periodically replaced. In this study, the use of axial-flow cyclone was proposed for particulate filter unit in the AHU for its low operation and maintenance cost. Novel shape of axial-flow cyclone was designed by using computational fluid dynamics (CFD). The shape of vortex vane was optimized in terms of pressure drop and tangential velocity. In addition, CFD analysis was validated experimentally through the pressure drop measurement of mock-up model. We found that pressure drop and tangential velocity of fluid through the axia-flow cyclone was significantly affected by the rotating degree of vortex vane and the numerical prediction of pressure drop agreed well with experimental measurement.

  • PDF

Axial Solid Holdup in a Circulating Fluidized Bed Plasma Reactor under Reduced Pressure (감압 순환유동층 플라즈마 반응기의 축방향 고체체류량)

  • Park, Sounghee
    • Korean Chemical Engineering Research
    • /
    • v.54 no.4
    • /
    • pp.527-532
    • /
    • 2016
  • The effects of gas velocity and solid circulation rate on the axial solid holdup distribution have been determined in a 10 mm-I.D. ${\times}$ 800 mm-high circulating fluidized bed plasma reactor under reduced pressure (1torr). Polystyrene polymer powder and nitrogen gas are used as solid and gas materials respectively. The change of solid circulation rate by a large gas flow rate of the riser (40~80 sccm) is also possible by a relatively small gas flow rate of the solid recirculation part (6.6~9.9 sccm). The solid circulation rate in the reactor under reduced pressure increases with increasing aeration velocity in the solid recirculation part. The axial solid holdup in the riser decreases from the dense at the bottom to the dilute phase at the top section of the riser. Solid holdups at the axial positions in the riser increase linearly with increasing solid circulating velocity. From these results, we could determine the position of plasma load for good plasma ignition, maintain and plasma reaction.

플라즈마 디스플레이 패널(Plasma Display Panel) 텔레비전에서의 냉각 소음 저감

  • 김규영;최민구;이덕주
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.719-724
    • /
    • 2003
  • The present experimental study deals with noise reduction and improvements in cooling performance in a plasma display panel(PDP) television (TV). To reduce the noise, the effects of installation parameters are studied. The experimental parameters under investigation are the distance between the fan and the rear case of a PDP TV, position of the strut on the fan, and the fan RPM. The variance of RPM is the most significant facto., and a 250 RPM decrease from 910 RPM causes about 4㏈(A) reduction in the system noise. To increase performance, flow characteristics are investigated by using a visualization technique and measuring the volume flow rate. The visualized results show that a radial direction flow due to large system resistance is significant, and an axial velocity oscillation is observed from the measurement of the volume flow rate. To prevent both a radial direction flow and an axial velocity oscillation, sponges are inserted in the space between f3n and the rear case. Inserted sponges improve the volume flow rate of cooling fans up to 32% since they convert a radial direction flow to an axial direction flow. Also an axial velocity oscillation with large amplitude and low RPM disappears. Increasing volume flow rate causes the PDP TV to improve its cooling performance. Additionally the same volume flow rate can be obtained with a decreased fan speed due to the inserted sponge. Noise reductions of 4.2 ㏈(A) at the rear and 1.1 ㏈(A) at the front of the TV are obtained by the decreased RPM. An increase of 10% of the volume flow rate is also achieved by inserting sponges.

  • PDF

Experimental Study on the Unsteady Flow under Various Operating Conditions of a Counter Rotating Axial Flow Fan (엇회전식 축류팬의 작동조건 변화에 따른 비정상 유동에 관한 실험적 연구)

  • Kang, Hyun-Koo;Cho, Lee-Sang;Cho, Jin-Soo
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1389-1394
    • /
    • 2004
  • Experiments were done for the unsteady flow in a counter rotating axial flow fan near peak efficiency and stall point. Flow fields in a counter rotating axial flow fan were measured at cross-sectional planes of the upstream and downstream of each rotor. Cross sectional passage flow patterns were investigated through the acquired data by the $45^{\circ}$ inclined hot-wire. Comparison of flow characteristics between two different operating conditions such as tip vortex, secondary flow and turbulence intensity were performed through the analyses of axial, radial and tangential velocity distributions. As a result, tip vortex and secondary flows are enforced and measured obviously at stall point.

  • PDF

Free vibration analysis of axially moving laminated beams with axial tension based on 1D refined theories using Carrera unified formulation

  • Daraei, Behnam;Shojaee, Saeed;Hamzehei-Javaran, Saleh
    • Steel and Composite Structures
    • /
    • v.37 no.1
    • /
    • pp.37-49
    • /
    • 2020
  • In this paper, free vibration finite element analysis of axially moving laminated composite beams subjected to axial tension is studied. It is assumed that the beam has a constant axial velocity and is subject to uniform axial tension. The analysis is based on higher-order theories that have been presented by Carrera Unified Formulation (CUF). In the CUF technique, the three dimensional (3D) displacement fields are expressed as the approximation of the arbitrary order of the displacement unknowns over the cross-section. This higher-order expansion is considered in equivalent single layer (ESL) model. The governing equations of motion are obtained via Hamilton's principle. Finally, several numerical examples are presented and the effect of the ply-angle, travelling speed and axial tension on the natural frequencies and beam stability are demonstrated.

A Study on the Performance Test of Axial-flow Cyclone Separator (축상유입식 사이클론 집진기 성능시험에 관한 연구)

  • Chin, Do-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.1
    • /
    • pp.101-106
    • /
    • 2020
  • Along with dust collection efficiency, pressure loss is a very important cyclone operation factor. A severe rise in pressure loss causes the problem of cost. To solve the problem, the method connecting axial-vane type cyclones in parallel is suggested recently. The axial vane type cyclone dust collector applied in this study is a small portable type. Multiple cyclones are installed in a round type. The basic performance test on the axial vane type cyclone dust collector was conducted. As a result, the cut size reduced along with a rise in the wind velocity of the cyclone dust collector inlet. According to the test on dust collection efficiency, the effect of dust collection began to appear in the range of 3㎛ and dust collection efficiency was greatly improved at 5 ㎛. The noise of the cyclone dust collector well met the fan sound power level of KSB 6361.