• 제목/요약/키워드: Axial magnetic field

검색결과 168건 처리시간 0.039초

대전력 펄스용 횡자계형 및 종자계형 진공스위치의 에너지 손실 특성 비교 (A Comparison of Energy Loss Characteristics between Radial and Axial Magnetic Field Type Vacuum Switches)

  • 이태호;허창수;이홍식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권3호
    • /
    • pp.130-136
    • /
    • 2003
  • Crowbar system Vacuum switches, widely used In a pulsed power system, could use the magnetic force to prevent the electrode damage. Vacuum switches using the magnetic forces are classified roughly into RMF(Radial Magnetic Field) and AMF(Axial Magnetic Field) type. The RMF type switches restrain a main electrode from aging due to high temperature and high density arc by rotating the arc which is driven by the Lorenz force. The AMF type switches generate axial magnetic field which decreases the electrode damage by diffusing arc. In this paper, we present the energy loss characteristics of both RMF and AMF type switches which are made of CuCr(75:25 wt%) electrodes. The time-dependent dynamic arc resistance of high-current pulsed discharge in a high vacuum chamber(~10$^{-6}$ Torr). which occurs in RMF and AMF type switches, was obtained by solving the circuit equation using the measured values of the arc voltage and current. In addition, we compared energy loss characteristics of both switches. Based on our results, it was found that the arc voltage and the energy loss of an AMF type switch are lower than a RMF type switch.

축자계형 진공인터럽터의 전자계 현상 해석 (Analysis of the Electromagnetic Phenomena in Vacuum Interrupter with Axial Magnetic Field Type)

  • 하성철;서상현
    • 한국전기전자재료학회논문지
    • /
    • 제16권10호
    • /
    • pp.952-957
    • /
    • 2003
  • The purpose of this paper is analyses about in 12kV/50kA vacuum interrupter with an axial magnetic field type electrode system through the studies of electromagnetic phenomena. Vacuum interrupter is important in electric safety part. In this paper, we performed analysis of electric field, magnetic field, current density in AMF electrode using the Maxwell 3D simulation. The current distribution and magnetic field in simple models are analyzed to verify its efficiency and accuracy. In addition the validity of FEM is confirmed by performing the analyses of distribution in current density and magnetic flux density.

축자계형 진공차단기의 진공아크 해석 (The Vacuum Arc Analysis of Vl Applied Axial Magnetic Field)

  • 강진;김민수;최승길;고광철;강형부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2221-2223
    • /
    • 1999
  • Axial magnetic field($B_z$) generated by special electrode construction in vacuum interrupters(Vl) is used to extinguish electric plasma arcs because that restrains this form expending. So VI applied axial magnetic field has more interruption capacity as compared with other VI. Also, the profile of toroidal field($B_{\theta}$) generated by $B_z$, is important to VI design. In this study, it was represented that the behavior of vacuum arc. In addition, The relationship between $B_z$ and $B_{\theta}$ was represented by using Dynamo theory. I hope that this study will be a good data in design of vacuum interrupters.

  • PDF

전기철도 차량에 대한 극저주파 자계영역의 시간영역 측정 및 스펙트럼 분석 (Time-domain measurement and spectral analysis of low frequency magnetic field on board of rolling stock)

  • 장동욱;정상기
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.263-268
    • /
    • 2008
  • The measurement of magnetic field is performed AC magnetic field emission density in driver cab and saloon's compartment of rolling stock. In order to measure magnetic-field emission, a three-axial magnetic-field sensor is used and connected to data process system. The AC magnetic field is checked and analysis through BNC output, DAQ cad and notebook PC. The spectral analysis is performed by short time Fourier transform(STFT) for time-domain emission signal.

  • PDF

축방향 자기장 인가를 통한 플라즈마토치 전극 수명연장 (Extension of Electrode Lifetime for Plasma Torch by Axial Magnetic Field)

  • 조주현;한용기;한현;권오경;최영욱
    • 전기학회논문지
    • /
    • 제56권11호
    • /
    • pp.1978-1981
    • /
    • 2007
  • Axial magnetic field was applied into the hollow anode of plasma torch for the purpose of extension of electrode lifetime. The average arc voltage increased because the arc column became longer, the arc voltage ripple frequency became low. The steady state of arc voltage was removed by applied magnetic filed. The lifetime of electrode was 60 times longer than operation without magnetic field.

Evolution of Coronal Magnetic Fields Consisting of Flux Ropes and Overlying Fields

  • 전홍달;이시백;최광선
    • 천문학회보
    • /
    • 제44권2호
    • /
    • pp.69.1-69.1
    • /
    • 2019
  • A series of numerical MHD simulations are performed to investigate the evolution of coronal magnetic fields consisting of two flux ropes and an overlying field. Depending on the directions of the axial current and the axial field, two co-helicity cases and two counter-helicity cases are addressed. In Case 1, in which both the axial currents and the axial fields are parallel, flux rope merging bears a huge flux rope with a large winding number. This flux rope naturally erupts, but the whole evolutionary process is rather slow. In Case 2, in which the axial currents are parallel while the axial fields are antiparallel, a self-closed structure is formed and it drives eruption. In Case 3, in which the axial currents are antiparallel and the axial fields are parallel, each flux rope erupts independently and the presence of the other flux rope does not affect the eruption of one flux rope. In Case 4, in which both the axial currents and the axial fields are antiparallel, interaction of the flux ropes and the overlying field effects a breakout reconnection creating an apple-like CME configuration. Our study tells what kind of eruption mechanisms are involved for different eruption features observed.

  • PDF

이중고정자 횡축 12/10 SRM의 설계 및 특성 해석 (Design and Characteristic Analysis of Double Stator Axial Field 12/10 SRM)

  • 손동호;안진우
    • 전기학회논문지
    • /
    • 제67권6호
    • /
    • pp.730-737
    • /
    • 2018
  • This paper aims to design of a double stator axial field 12/10 SRM. Conventional and single stator axial field SRMs were reviewed to apply for automotive cooling fan. The axial field SRM has the advantage of shorter flux path, higher torque per volume and lower iron loss. However, there is axial eccentricity in single stator axial field SRM due to one side excitation. Therefore, a double stator type is designed in this paper to reduce the axial eccentricity. And the trapezoidal pole shape of the stator increases the flow of magnetic flux from stator to rotor and the torque region. The torque and efficiency are compared and tested with experiments.

설계변수에 따른 진공인터럽터용 종자계방식 전극의 아크특성에 관한 연구 (A Study on the Arc Characteristics of Axial Magnetic Field Type Electrode for Vacuum interrupter by Desing Parameters)

  • 김성일;박흥태;안희일;서정민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.672-674
    • /
    • 2001
  • Axial magnetic field(AMF) type electrode can increase the interrupting capability of vacuum interrupters. But, this interrupting capability vary with design parameters such as shape of electrode, slits of contact, material of contact and so on. In this paper, shown arc characteristics of unipolar axial magnetic field type electrode for vacuum interrupter by design parameters such as shape of contact slits and diameter of contact. And, confirmed vacuum arc configuration by individual design parameter using high speed camera.

  • PDF

형광등 Positive column에 대한 자장인가 효과 (Magnetic field effect on the positive column of fluorescent lamp)

  • 지철근;김창종
    • 전기의세계
    • /
    • 제31권3호
    • /
    • pp.197-203
    • /
    • 1982
  • The effects on the characteristics of 20-W fluorescent lamp were studied when applying magnetic field to its positive column. First, when the direction of the magnetic field is axial, i.e., along the lamp, if the magnitude of the field is stronger than the critical field, lamp voltage is increased, lamp current decreased, luminous flux increased, starting voltage decreased, as increasing the applied magnetic field. At the magnetic flux density is 130 gauss, luminous flux is increased to about 6 percents and starting voltage is increased to about 45 percents. Second, when the direction of the magnetic field is transverse to the lamp axis, as increasing the applied magnetic field, lamp voltage is increased, lamp current decreased, luminous flux increased and starting voltage is nearly constant, but the rates of increase or decrease of this case is different from those of the first. At the magnetic flux density is 300 gauss, luminous flux is increased about 45 percents. In both cases, electric power dissipated by lamps is the same as that of the lamp which magnetic field is not applied to.

  • PDF

8인치 실리콘성장을 위한 커스프 MCZ계에서 축방향 산소분포에 대한 연구 (A numerical study on the optimum operation condition for axial oxygen concentration in 8 inch silicon growth by cusp MCZ)

  • 이승철;윤종규
    • 한국결정성장학회지
    • /
    • 제7권3호
    • /
    • pp.406-417
    • /
    • 1997
  • 초크랄스키법들 의한 8인치 실리콘 단결정 성장계에 대칭과 비대칭 커스프 자장을 인가하여 결정을 성장시켰을 때 축방향으로 일정한 산소농도분포를 가질 수 있는 적절한 인가 자장의 크기와 비대칭도에 대한 수치해석적 연구를 수행하였다. 결정이 성장할 때 커스프 자장의 형태가 유지되는 방법으로 도가니의 위치를 변화시키는 방법과 인가코일의 위치를 변화시키는 방법을 비교하였다. 대칭 커스프 자장이 인가된 경우, 축방향으로 일정한 산소농도를 얻을 수 있는 자장의 강도변화는 결정이 성장함에 따라 아래로 볼록한 형태를 띠었다. 축밟향으로 일정한 산소농도분포를 갖기 위해 도가니의 위치를 변화시키는 방법과 코일의 위치를 변화시키는 방법을 비교한 결과 비슷한 산소농도의 표준편차값을 가짐을 알 수 있었다. 비대칭 자장이 인가된 경우, 축방향으로 일정한 산소농도 분포를 얻기 위해서는 비대칭도는 결정이 성장함에 따라 점차 증가하는 양상을 보였다.

  • PDF