• 제목/요약/키워드: Axial loading test

검색결과 391건 처리시간 0.032초

Effects of Low Grade Axial Loading on Discogenic Low Back Pain: A Case Report

  • Chang, Duncan;Boby, Arantxa;Madonna, James
    • 국제물리치료학회지
    • /
    • 제9권4호
    • /
    • pp.1683-1686
    • /
    • 2018
  • Low back pain (LBP) is the most common reason for seeking physical therapy (PT) care. Recent studies suggest that axial loading can have a positive impact on the intervertebral disc by improving its tensile strength. Further, whole body vibration (WBV) appears to improve spinal muscle relaxation. Therefore, this case study describes the use of axial loading using a mini-trampoline in a female with chronic LBP. This case report is a single subject design. This patient is a 29-year-old female with a six-month history of low back pain following a motor vehicle accident. MRI found herniated discs at L4 and L5, clinical tests were positive for pain in the L4 and L5 dermatome and myotome the slump test was positive for neural tension, and LBP was constant at 4-6/10 over the past four months. She received axial loading exercises using a mini-trampoline and performed six sessions that were, scheduled twice a week for three weeks. Her Oswestry Disability Index (ODI) score improved from 40% at the time of her first visit to 22% at her final visit. Pain measure on the Numeric Pain Rating Scale (NPRS) after the first treatment was 7/10, and her pain after the final treatment was 0/10. These changes in the pain scores are clinically significant and exceed the minimal clinically important difference (MCID). This patient had a significant improvement in her pain using the NPRS and the ODI. This case study suggests that axial loading may be an effective treatment for some individuals with discogenic chronic low back pain.

Complete collapse test of reinforced concrete columns

  • Abdullah, Abdullah;Takiguchi, Katsuki
    • Structural Engineering and Mechanics
    • /
    • 제12권2호
    • /
    • pp.157-168
    • /
    • 2001
  • In this paper, experimental investigation into the behavior of reinforced concrete (RC) columns tested under large lateral displacement with four different types of loading arrangements is presented. Each loading arrangement has a different system for controlling the consistency of the loading condition. One of the loading arrangements used three units of link mechanism to control the parallelism of the top and bottom stub of column during testing, and the remaining employed eight hydraulic jacks for the same purpose. The loading systems condition used in this investigation were similar to the actual case in a moment-resisting frame where the tested column was displaced in a double curvature. Ten model column specimens, divided into four series were prepared. Two columns were tested monotonically until collapse, and unless failure took place at an earlier stage of loading, the remaining eight columns were tested under cyclic loading. Test results indicated that the proposed system to keep the top and bottom stubs parallel during testing performed well.

Height-thickness ratio on axial behavior of composite wall with truss connector

  • Qin, Ying;Shu, Gan-Ping;Zhou, Xiong-Liang;Han, Jian-Hong;He, Yun-Fei
    • Steel and Composite Structures
    • /
    • 제30권4호
    • /
    • pp.315-325
    • /
    • 2019
  • Double skin composite walls offer structural and economic merits over conventional reinforced concrete counterparts in terms of higher capacity, greater stiffness, and better ductility. This paper investigated the axial behavior of double skin composite walls with steel truss connectors. Full-scaled tests were conducted on three specimens with different height-to-thickness ratios. Test results were evaluated in terms of failure mode, load-axial displacement response, buckling loading, axial stiffness, ductility, strength index, load-lateral deflection, and strain distribution. The test data were compared with AISC 360 and Eurocode 4 and it was found that both codes provided conservative predictions on the safe side.

가변진폭하중하에서 다축-다점 하중 Counting method를 이용한 피로수명평가 (Fatigue Life Estimation Using the Multi-Axial Multi-Point Load Counting Method under Variable Amplitude Loading)

  • Lee, W.S.;Lee, H.W.
    • 한국정밀공학회지
    • /
    • 제14권6호
    • /
    • pp.22-27
    • /
    • 1997
  • In general, the load which acts on the structure is almost independent of time in many locations. In this case. It is difficult to estimate the life with the service load history, because the structure is on the multi- axial and multi-point loading states. In this study, the service load of the excavator which is widely used in industry field was calculated using measured cylinder pressures and displacements. The fatigue life was estimated using the multi-axial and multi-point load counting method. Service load history of 4 pin joint which act independently each other is yielded by mult-axial and multi-point load counting method. The stress spectrum is yielded by superposition of the results of FEM stress analysis applied unit load. Palm- gren-Miner's cumulative Damage is 0.000804 for Von Mises equivalent stress sequence by one side fillet weld S-N curve. This result agress with Bench test results. As a result of this study, the fatigue life esti- mation using the multi-axial and multi-axial and multi-point load counting method is useful.

  • PDF

Experimental research on dynamic response of red sandstone soil under impact loads

  • Wang, Tong;Song, Zhanping;Yang, Jianyong;Wang, Junbao;Zhang, Xuegang
    • Geomechanics and Engineering
    • /
    • 제17권4호
    • /
    • pp.393-403
    • /
    • 2019
  • The cycling impact test of red sandstone soil under different axial pressure and different impact loads are conducted to reveal the mechanical properties and energy consumption mechanism of red sandstone soil with static-dynamic coupling loading. The results show that: Under the action of different axial pressure and different impact loads, the peak stress of the specimen increases, and then tends to be stable with the times of impact. With the increase of impact times, the specific energy absorption value of the red sandstone soil specimen is increased first and then gentle development trend. When the impact loads are certain, the larger the axial pressure is, the smaller the peak value of energy absorption, which indicates that the energy utilization rate is not high under the condition of large axial pressure. Through the analysis of energy utilization, it is found that the smaller the impact load, the higher the energy utilization rate. The greater the axial pressure, the lower the energy utilization rate. when the axial pressure is large, the impact loads corresponding to the maximum values of reflectivity, transmissivity and absorptivity are the same. The relationship between reflectivity and transmissivity is negatively correlated.

Unique local deformations of the superelastic SMA rods during stress-relaxation tests

  • Ashiqur Rahman, Muhammad;Rahman Khan, Mujibur
    • Structural Engineering and Mechanics
    • /
    • 제22권5호
    • /
    • pp.563-574
    • /
    • 2006
  • This paper studies mechanical behavior of the superelastic shape memory alloy (SMA) rods in terms of local deformations and time via tensile loading-unloading cycles for both ends fixed end constraints. Besides the unique stress induced martensitic transformation (SIMT), SMA's time dependent behavior when it is in mixed-phase condition upon loading and unloading, also need careful attention with a view of investigating the local deformation of the structural elements made of the same material. With this perspective, the so-called stress-relaxation tests have been performed to demonstrate and investigate the local strains-total strains relationships with time, particularly, during the forward SIMT. Some remarkable phenomena have been observed pertaining to SIMT, which are absent in traditional materials and those unique phenomena have been explained qualitatively. For example, at the stopped loading conditions the two ends (fixed end and moving end of the tensile testing machine) were in fixed positions. So that there was no axial overall deformation of the specimen but some notable increase in the axial local deformation was shown by the extensometer placed at the middle of the SMA specimen. It should be noted that this peculiar behavior termed as 'inertia driven SIMT' occurs only when the loading was stopped at mixed phase condition. Besides this relaxation test for the SMA specimens, the same is performed for the mild steel (MS) specimens under similar test conditions. The MS specimens, however, show no unusual increase of local strains during the stress relaxation tests.

Axial compression mechanical properties of steel reinforced recycled concrete column exposure to temperatures up to 800℃

  • Chen, Zongping;Liang, Yuhan;Mo, Linlin;Ban, Maogen
    • Steel and Composite Structures
    • /
    • 제41권5호
    • /
    • pp.731-746
    • /
    • 2021
  • The purpose of this paper is to investigate the axial bearing capacity and residual properties of steel reinforced recycled aggregate concrete (SRC) column after elevated temperature. A total of 48 SRC columns were designed for the static loading test after elevated temperature. The variables include replacement ratios, designed temperature, target duration, thicknesses of cover concrete, steel ratios and stirrup spacing. From this test, the mass loss ratio and stress load-deformation curve were obtained, and the influence of various parameters on residual bearing capacity were analyzed. ABAQUS was used to calculate the temperature field of specimens, and then got temperature damage distribution on the cross-section concrete. It was shown that increasing of the elevated temperatures leaded to the change of concrete color from smoky-gray to grayish brown and results in reducing the bearing capacity of SRC columns. The axial damage and mechanism of SRC columns were similar to those of reinforced natural aggregate concrete columns at the same temperatures. Finally, the calculation method of axial compressive residual bearing capacity of SRC columns recycled concrete columns after high temperature was reported based on the test results and finite element analysis.

Experimental study on seismic performance of steel reinforced concrete T-shaped columns

  • Liu, Zuqiang;Zhou, Chaofeng;Xue, Jianyang;Leon, Roberto T.
    • Steel and Composite Structures
    • /
    • 제36권3호
    • /
    • pp.339-353
    • /
    • 2020
  • This study investigates the seismic performance of steel reinforced concrete (SRC) T-shaped columns under low cyclic loading tests. Based on test results of ten half-scale column specimens, failure patterns, hysteretic behavior, skeleton curves, ultimate strength, ductility, stiffness degradation and energy dissipation capacity were analyzed. The main variables included loading angles, axial compression ratios and steel ratios. The test results show that the average values of the ductility factor and the equivalent viscous damping coefficient with respect to the failure of the columns were 5.23 and 0.373, respectively, reflecting good seismic performance. The ductility decreased and the initial stiffness increased as the axial compression ratio of the columns increased. The strength increased with increasing steel ratio, as expected. The columns displaced along the web had higher strength and initial stiffness, while the columns displaced along the flange had better ductility and energy dissipation capacity. Based on the test and analysis results, a formula is proposed to calculate the effective stiffness of SRC T-shaped columns.

내부연결 원추형 임플란트의 육각구조의 유무에 따른 연결부 안정성: 실험적 연구 (Joint stability of internal conical connection abutments with or without hexagon indexes: an in vitro study)

  • 이상운;차민상;이지혜;조리라;박찬진
    • 구강회복응용과학지
    • /
    • 제36권2호
    • /
    • pp.95-103
    • /
    • 2020
  • 목적: 본 연구의 목적은 내부연결 원추형 임플란트의 육각구조 유무가 임플란트 지대주 장축변위와 임플란트 지대주 나사의 풀림토크에 미치는 영향을 평가하고자 하였다. 연구 재료 및 방법: 내부연결 원추형 임플란트를 육각구조를 가진 지대주 그룹(HEX)과 육각구조를 갖지 않는 지대주 그룹(CON)으로 나누고 각 그룹 당 10쌍의 시편을 체결하였다. 지대주 나사를 30 Ncm 조임회전력을 가하여 체결한 뒤 장축변위 및 풀림토크값을 측정하고 250 N 수직적 반복하중을 100,000회 가한 뒤 장축변위 및 풀림토크값을 측정하였다. 각 단계마다 디지털 마이크로미터를 이용하여 임플란트 직경과 수직적 높이를 측정하였고 전자 토크게이지를 이용하여 풀림토크값을 측정하였다. 각 군간의 값의 유의차를 확인하기 위하여 독립 표본 T 검정을 이용하여 통계분석하였다(α = 0.05). 결과: HEX 군은 조임회전력을 가한 뒤 유의하게 높은 장축변위를 나타내였다(P < 0.05). HEX 군과 CON 군은 수직적 반복하중 후 장축변위에 유의한 차이를 보이지 않았다(P = 0.052). HEX 군과 CON 군은 수직적 반복하중 전, 후 풀림토크값 모두 유의한 차이를 보이지 않았다(P = 0.057 and P = 0.138). 모든 그룹에서 반복하중 후 풀림토크값 상실율이 증가하였다(P < 0.05). 결론: 내부연결 원추형 임플란트에서 육각구조를 가진 경우 장축 변위가 더 컸으며, 그 외의 연결부 안정성은 유사하였다. 모든 그룹에서 반복하중 후 풀림토크값 상실율이 증가하였다.

Ti-6Al-4V 재의 UNSM 처리에 의한 피로특성변화 - 회전굽힘 피로시험과 축하중 인장압축 피로시험 비교 - (Variation of Fatigue Properties in Nanoskinned Ti-6Al-4V - Rotating Bending and Axial Loading Tension-Compression Cycle -)

  • 서민수;편영식;서창민
    • 대한기계학회논문집A
    • /
    • 제36권4호
    • /
    • pp.443-449
    • /
    • 2012
  • Ti-6Al-4V 재에 다양한 표면처리방법을 통하여 나노스킨화된 피로시험편을 제작하고 회전굽힘피로 시험과 축하중 인장압축피로시험을 수행하였다. 특히 S-N 곡선에서 초음파나노표면개질(UNSM)법은 국내특허기술로 다른 처리법들보다 우수한 결과를 보였고, UNSM 처리된 직경 5 mm 재는 6 mm 티타늄재를 대치 가능할 성능을 얻었다. UNSM 처리된 $10^6$ 사이클 이상의 장수명영역에서 피로강도가 크게 향상되는 시험결과를 얻었다. 균열발생 패턴의 분석을 통하여 Ti-6Al-4V 재는 응력의 작용형태에 따라 표면균열발생형(surface originating crack type)과 내부균열발생형(interior originating crack type)인 어안균열(fish eye crack)이 발생하는 메커니즘을 분석하였다.