Height-thickness ratio on axial behavior of composite wall with truss connector  

Qin, Ying (Key Laboratory of Concrete and Prestressed Concrete Structures of Ministry of Education, and National Prestress Engineering Research Center, School of Civil Engineering, Southeast University)
Shu, Gan-Ping (Key Laboratory of Concrete and Prestressed Concrete Structures of Ministry of Education, and National Prestress Engineering Research Center, School of Civil Engineering, Southeast University)
Zhou, Xiong-Liang (Zhejiang Southeast Space Frame Group Company Limited)
Han, Jian-Hong (Key Laboratory of Concrete and Prestressed Concrete Structures of Ministry of Education, and National Prestress Engineering Research Center, School of Civil Engineering, Southeast University)
He, Yun-Fei (Zhejiang Southeast Space Frame Group Company Limited)
Publication Information
Steel and Composite Structures / v.30, no.4, 2019 , pp. 315-325 More about this Journal
Abstract
Double skin composite walls offer structural and economic merits over conventional reinforced concrete counterparts in terms of higher capacity, greater stiffness, and better ductility. This paper investigated the axial behavior of double skin composite walls with steel truss connectors. Full-scaled tests were conducted on three specimens with different height-to-thickness ratios. Test results were evaluated in terms of failure mode, load-axial displacement response, buckling loading, axial stiffness, ductility, strength index, load-lateral deflection, and strain distribution. The test data were compared with AISC 360 and Eurocode 4 and it was found that both codes provided conservative predictions on the safe side.
Keywords
axial behavior; composite wall; truss connector; height-to-thickness ratio; structural performance;
Citations & Related Records
Times Cited By KSCI : 12  (Citation Analysis)
연도 인용수 순위
1 AISC 360-16 (2016), Specification for structural steel buildings; American Institute of Steel Construction, Chicago, IL, USA.
2 Akiyama, H. and Sekimoto, H. (1991), "A compression and shear loading tests of concrete filled steel bearing wall", Transaction of 11th Structural Mechanics in Reactor Technology (SMiRT-11), Tokyo, Japan, August.
3 Choi, B.J. and Han, H.S. (2009), "An experiment on compressive profile of the unstiffened steel plate-concrete structures under compression loading", Steel Compos. Struct., Int. J., 9(6), 519-534.   DOI
4 Choi, B.J., Kang, C.K. and Park, H.Y. (2014), "Strength and behavior of steel plate-concrete wall structures using ordinary and eco-oriented cement concrete under axial compression", Thin Wall. Struct., 84, 313-324.   DOI
5 EN 1994-1-1:2004 (2004), Eurocode 4: Design of composite steeel and concrete structures-Part 1-1: General rules and rules for buildings; British Standards Institution, London, UK.
6 Eom, T.S., Park, H.G., Lee, C.H., Kim, J.H. and Chang, I.H. (2009), "Behavior of double skin composite wall subjected to in-plane cyclic loading", J. Struct. Eng., 135(10), 1239-1249.   DOI
7 GB50010-2010 (2010), Code for design of concrete structures; China Architecture & Building Press, Beijing, China.
8 GB50017-2017 (2017), Standard for classification of steel structures; China Architecture & Building Press, Beijing, China.
9 Gheidi, A., Mirtaheri, M., Zandi, A.P. and Alanjari, P. (2011), "Effect of filler material on local and global behaviour of buckling-restrained braces", Struct. Des. Tall Spec. Build., 20(6), 700-710.   DOI
10 Hilo, S.J., Badaruzzaman, W.H.W., Osman, S.A. and Al-Zand, A.W. (2016), "Structural behavior of composite wall systems strengthened with embedded cold-formed steel tube", Thin Wall. Struct., 98, 607-616.   DOI
11 Huang, Z.Y. and Liew, J.Y. (2016), "Compressive resistance of steel-concrete-steel sandwich composite walls with J-hook connectors", J. Constr. Steel Res., 124, 142-162.   DOI
12 Huang, S.T., Huang, Y.S., He, A., Tang, X.L., Chen, Q.J., Liu, X.P. and Cai, J. (2018), "Experimental study on seismic behaviour of an innovative composite shear wall", J. Constr. Steel Res., 148, 165-179.   DOI
13 JGJ/T 380-2015 (2015), Technical specification for steel plate shear walls; China Architecture & Building Press, Beijing, China.
14 Ji, X.D., Cheng, X.W., Jia, X.F. and Varma, A.H. (2017), "Cyclic in-plane shear behavior of double-skin composite walls in highrise buildings", J. Struct. Eng., 143(6), 04017025.
15 Kanchi, M. (1996), "Experimental study on a concrete filled steel structure Part 2 Compressive tests (1). Summary of Technical Papers of Annual Meeting", Architectural Institute of Japan, 1996, 1071-1072.
16 Korkmaz, H.H. and Ecemis, A.S. (2017), "Seismic upgrading of reinforced concrete frames with steel plate shear walls", Earthq. Struct., Int. J., 13(5), 473-484.
17 Liao, J.J. and Ma, G.W. (2018), "Energy absorption of the ring stiffened tubes and the application in blast wall design", Struct. Eng. Mech., Int. J., 66(6), 713-727.
18 Luo, Y.F., Guo, X.N., Li, J., Xiong, Z., Meng, L., Dong, N.C. and Zhang, J. (2015), "Experimental research on seismic behaviour of the concrete-filled double-steel-plate composite wall", Adv. Struct. Eng., 18(11), 1845-1858.   DOI
19 Mirtaheri, M. and Zoghi, M.A. (2016), "Design guides to resist progressive collapse for steel structures", Steel Compos. Struct., Int. J., 20(2), 357-378.   DOI
20 Mirtaheri, M., Sehat, S. and Nazeryan, M. (2018), "Improving the behavior of buckling restrained braces through obtaining optimum steel core length", Struct. Eng. Mech., Int. J., 65(4), 401-408.
21 Nguyen, N.H. and Whittaker, A.S. (2017), "Numerical modelling of steel-plate concrete composite shear walls", Eng. Struct., 150, 1-11.   DOI
22 Qin, Y., Chen, Z.H., Bai, J.J. and Li, Z.L. (2016), "Test of extended thick-walled through-diaphragm connection to thickwalled CFT column", Steel Compos. Struct., Int. J., 20(1), 1-20.   DOI
23 Nie, J.G., Ma, X.W., Tao, M.X., Fan, J.S. and Bu, F.M. (2014), "Effective stiffness of composite shear wall with double plates and filled concrete", J. Constr. Steel Res., 99, 140-148.   DOI
24 Qin, Y., Chen, Z.H. and Rong, B. (2015a), "Component-based mechanical models for concrete-filled RHS connections with diaphragms under bending moment", Adv. Struct. Eng., 18(8), 1241-1255.   DOI
25 Qin, Y., Chen, Z.H. and Rong, B. (2015b), "Modeling of CFRT through-diaphragm connections with H-beams subjected to axial load", J. Contr. Steel Res., 114, 146-156.   DOI
26 Qin, Y., Lu, J.Y. and Cao, S. (2017a), "Theoretical study on local buckling of steel plate in concrete filled tube column under axial compression", ISIJ Int., 57(9), 1645-1651.   DOI
27 Qin, Y., Shu, G.P., Fan, S.G., Lu, J.Y., Cao, S. and Han, J.H. (2017b), "Strength of double skin steel-concrete composite walls", Int. J. Steel Struct., 17(2), 535-541.   DOI
28 Qin, Y., Du, E.F., Li, Y.W. and Zhang, J.C. (2018c), "Local buckling of steel plates in composite structures under combined bending and compression", ISIJ Int., 58(11), 2133-2141.   DOI
29 Qin, Y., Zhang, J.C., Shi, P., Chen, Y.F., Xu, Y.H. and Shi, Z.Z. (2018a), "Behavior of improved through-diaphragm connection to square tubular column under tensile loading", Struct. Eng. Mech., Int. J., 68(4), 475-483.
30 Qin, Y., Shu, G.P., Du, E.F. and Lu, R.H. (2018b), "Buckling analysis of elastically-restrained steel plates under eccentric compression", Steel Compos. Struct., Int. J., 29(3), 379-389.
31 Xiong, Q.Q., Chen, Z.H., Zhang, W., Du, Y.S., Zhou, T. and Kang, J.F. (2017), "Compressive behaviour and design of L-shaped columns fabricated using concrete-filled steel tubes", Eng. Struct., 152, 758-770.   DOI
32 Sakr, M.A., El-Khoriby, S.R., Khalifa, T.M. and Nagib, M.T. (2017), "Modeling of RC shear walls strengthened by FRP composites", Struct. Eng. Mech., Int. J., 61(3), 407-417.   DOI
33 Shekastehband, B., Mohammadbagheri, S. and Taromi, A. (2018), "Seismic behavior of stiffened concrete-filled double-skin tubular columns", Steel Compos. Struct., Int. J., 27(5), 577-598.
34 Usami, S., Akiyama, H., Narikawa, M., Hara, K., Takeuchi, M. and Sasaki, N. (1995), "Study on a concrete filled steel structure for nuclear plants (part 2). Compressive loading tests on wall members", Transaction of 13th Structural Mechanics in Reactor Technology (SMiRT-13), Porto Alegre, Brazil, August.
35 Yan, J.B., Wang, Z., Wang, T. and Wang, X.T. (2018), "Shear and tensile behaviors of headed stud connectors in double skin composite shear wall", Steel Compos. Struct., Int. J., 26(6), 759-769.
36 Zoghi, M.A. and Mirtaheri, M. (2016), "Progressive collapse analysis of steel building considering effects of infill panels", Struct. Eng. Mech., Int. J., 59(1), 59-82.   DOI