• 제목/요약/키워드: Axial length

검색결과 909건 처리시간 0.036초

Measurement Reliability of Axial Length of the Human Eye by using Partial Coherence Interferometry

  • Kim, Jae-Hyung;Moon, Tae Hwan;Chae, Ju Byung;Hyung, Sungmin
    • Journal of the Optical Society of Korea
    • /
    • 제18권5호
    • /
    • pp.546-550
    • /
    • 2014
  • To investigate the minimum near-infrared ray intensity required (quantifiable threshold value) for consistent measurements of axial length (AL) using partial coherence interferometry (PCI), we attached two polarizing lenses (PL) to two types of PCI (IOLmaster, ALscan). The near-infrared ray intensity of PCI was modified by rotating the axis of one PL at intervals of 5 degrees. The right eye of each volunteer was measured three times and the AL and signal-to-noise ratio (SNR) was recorded five times for each measurement. Reduction of light intensity was theoretically estimated using Malus' Law. AL was measured consistently with both IOLmaster and ALscan until they reached 55 degrees (1.33 % of intensity) and 60 degrees (0.77%), respectively (P = 0.343, Log-rank test). In contrast, SNR decreased as light intensity decreased. In addition, to analyze media opacities that precluded measurement of AL, we retrospectively reviewed the medical records of patients unmeasurable by PCI (ALscan) from May to November 2013. Thirty-eight of 473 eyes (8.0%) could not be measured using ALscan due to media opacities, such as severe posterior subcapsular cataract (PSC, 11 eyes), hypermature cataract (9 eyes), and vitreous hemorrhage (18 eyes). The mean grades of vitreous haze and PSC were $7.72{\pm}0.96$ and $4.45{\pm}1.04$, respectively. In conclusion, up to 0.77-1.33% of near-infrared rays decreased, and AL could be measured consistently.

The Effect of Periocular Acupressure with a Medical Massager for Myopia Children

  • Cha, Ho-Yeol;Jung, A-Ram;Kang, Byoung-kab;Song, Ji-Hoon;Jung, Jae Ho;Cheon, Jin Hong;Choi, Jun Yong;Kim, Kibong
    • 대한한의학회지
    • /
    • 제37권2호
    • /
    • pp.53-61
    • /
    • 2016
  • Objectives: Considering high prevalence of myopia in Asian countries, social cost paid for myopia may gradually increase in Korea. However, studies for developing myopia treatment are deficient. The study was to evaluate whether the periocular acupressure with a medical massager is effective for suppressing myopia progression. Methods: This study was an investigator-sponsored, prospective, open-labeled, and superiority pre and post single-armed study. 14 myopia children aged 7-12 years wore a medical massager for 15 minutes to stimulate periocular acupoints. For 24 weeks, the participants used the device twice a day. Based on prior studies, the refraction change of naturally proceeded myopia was set as -0.38 D. The axial length change of naturally proceeded myopia was set as 0.228 mm. To assess the safety, we performed vital sign check, physical examination, visual acuity test, slit lamp examination, IOP measurement, and fundus examination. Results: The refraction and axial length of the participants increased. For 24 weeks, the change in refraction was -0.38 D at the right eye and -0.40 D at the left. The change in axial length was 0.21 mm at the right and 0.22 mm at the left. In the safety assessment, any adverse event did not occur. Conclusions: There was no significant difference between the control group and the intervention group. The effect of growth may have more contributed to our result than that of acupressure. Based on our result, a full-scale study will not be conducted.

Testing, simulation and design of back-to-back built-up cold-formed steel unequal angle sections under axial compression

  • Ananthi, G. Beulah Gnana;Roy, Krishanu;Chen, Boshan;Lim, James B.P.
    • Steel and Composite Structures
    • /
    • 제33권4호
    • /
    • pp.595-614
    • /
    • 2019
  • In cold-formed steel (CFS) structures, such as trusses, transmission towers and portal frames, the use of back-to-back built-up CFS unequal angle sections are becoming increasingly popular. In such an arrangement, intermediate welds or screw fasteners are required at discrete points along the length, preventing the angle sections from buckling independently. Limited research is available in the literature on axial strength of back-to-back built-up CFS unequal angle sections. The issue is addressed herein. This paper presents an experimental investigation on both the welded and screw fastened back-to-back built-up CFS unequal angle sections under axial compression. The load-axial shortening and the load verses lateral displacement behaviour along with the deformed shapes at failure are reported. A nonlinear finite element (FE) model was then developed, which includes material non-linearity, geometric imperfections and modelling of intermediate fasteners. The FE model was validated against the experimental test results, which showed good agreement, both in terms of failure loads and deformed shapes at failure. The validated FE model was then used for the purpose of a parametric study to investigate the effect of different thicknesses, lengths and, yield stresses of steel on axial strength of back-to-back built-up CFS unequal angle sections. Five different thicknesses and seven different lengths (stub to slender columns) with two different yield stresses were investigated in the parametric study. Axial strengths obtained from the experimental tests and FE analyses were used to assess the performance of the current design guidelines as per the Direct Strength Method (DSM); obtained comparisons show that the current DSM is conservative by only 7% on average, while predicting the axial strengths of back-to-back built-up CFS unequal angle sections.

Study on axial compressive behavior of quadruple C-channel built-up cold-formed steel columns

  • Nie, Shaofeng;Zhou, Tianhua;Liao, Fangfang;Yang, Donghua
    • Structural Engineering and Mechanics
    • /
    • 제70권4호
    • /
    • pp.499-511
    • /
    • 2019
  • In this study, the axial compressive behavior of novel quadruple C-channel built-up cold-formed steel columns with different slenderness ratio was investigated, using the experimental and numerical analysis. The axial compressive capacity and failure modes of the columns were obtained and analyzed. The finite element models considering the geometry, material and contact nonlinearity were developed to simulate and analyze the structural behavior of the columns further. There was a great correlation between the numerical analyses and test results, which indicated that the finite element model was reasonable and accurate. Then influence of, slenderness ratio, flange width-to-thickness ratio and screw spacing on the mechanical behavior of the columns were studied, respectively. The tests and numerical results show that due to small slenderness ratio, the failure modes of the specimens are generally local buckling and distortional buckling. The axial compressive strength and stiffness of the quadruple C-channel built-up cold-formed steel columns decrease with the increase of maximum slenderness ratio. When the screw spacing is ranging from 150mm to 450mm, the axial compressive strength and stiffness of the quadruple C-channel built-up cold-formed steel columns change little. The axial compressive capacity of quadruple C-channel built-up cold-formed steel columns increases with the decrease of flange width-thickness ratio. A modified effective length factor is proposed to quantify the axial compressive capacity of the quadruple C-channel built-up cold-formed steel columns with U-shaped track in the ends.

Behaviour and strength of back-to-back built-up cold-formed steel unequal angle sections with intermediate stiffeners under axial compression

  • Gnana Ananthi, G. Beulah;Roy, Krishanu;Lim, James B.P.
    • Steel and Composite Structures
    • /
    • 제42권1호
    • /
    • pp.1-22
    • /
    • 2022
  • In cold-formed steel (CFS) structures, such as trusses, transmission towers and portal frames, the use of back-to-back built-up CFS unequal angle sections are becoming increasingly popular. In such an arrangement, intermediate welds or screw fasteners are required at discrete points along the length, preventing the angle sections from buckling independently. Limited research is available in the literature on axial strength of back-to-back built-up CFS unequal angle sections. The issue is addressed herein. This paper presents an experimental investigation reported by the authors on back-to-back built-up CFS unequal angle sections with intermediate stiffeners under axial compression. The load-axial shortening behaviour along with the deformed shapes at failure are reported. A nonlinear finite element (FE) model was then developed, which includes material non-linearity, geometric imperfections and modelling of intermediate fasteners. The FE model was validated against the experimental test results, which showed good agreement, both in terms of failure loads and deformed shapes at failure. The validated finite element model was then used for the purpose of a parametric study comprising 96 models to investigate the effect of longer to shorter leg ratios, stiffener provided in the longer leg, thicknesses and lengths on axial strength of back-to-back built-up CFS unequal angle sections. Four different thicknesses and seven different lengths (stub to slender columns) with three overall widths to the overall depth (B/D) ratios were investigated in the parametric study. Axial strengths obtained from the experimental tests and FE analyses were used to assess the performance of the current design guidelines as per the Direct Strength Method (DSM); obtained comparisons show that the current DSM is conservative by only 7% and 5% on average, while predicting the axial strengths of back-to-back built-up CFS unequal angle sections with and without the stiffener, respectively.

사각 채널에 설치된 테이프가 열전달과 마찰계수에 미치는 효과 (Effects of Tape on Heat Transfer and Friction Factor in a Square Channel)

  • 안수환;강호근;배성택;아리바시아크리시나 부트라
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2402-2407
    • /
    • 2007
  • Heat transfer distributions and friction factors in square channels (3.5 ${\times}$ 3.5 cm) with twisted tape inserts and with twisted tape inserts plus interrupted ribs are respectively investigated. Tests are performed for Reynolds numbers ranging from 8,900 to 29,000. The rib height-to-channel hydraulic diameter, e/Dh, is kept at 0.057 and test section length-to-hydraulic diameter, L/Dh is 30. The twisted tape is 0.1 mm thick carbon steel sheet with diameter of 3.3cm, length of 90cm, and 2.5 turns. The square ribs are arranged to follow the trace of the twisted tape and along the flow direction defined as axial interrupted ribs. Each wall of the square channel is composed of isolated aluminum sections. The following conclusions from the experimental study were drawn as: 1) In the 4 heating wall channel with twisted tape inserts, Nusselt number based on bottom wall temperature is enhanced by 1.2 - 1.6 times if adding the axial interrupted ribs on the bottom wall only. 2) The twisted tape with interrupted ribs under the two-sided heating condition produces the highest heat transfer performance. 3) Friction factor data obtained for the square channel with twisted tape inserts plus axial interrupted ribs are less than those in the past publications for circular tubes with axial interrupted ribs and twisted tape inserts.

  • PDF

Ultrastructures of Germ Cells and the Accessory Cells During Spermatogenesis in Male Gomphina veneriformis (Bivalvia: Veneridae) on the East Sea of Korea

  • Chung, Ee-Yung;Chung, Chang-Ho;Kim, Jin-Hee;Park, Sung-Woo;Park, Kwan-Ha
    • 한국패류학회지
    • /
    • 제26권1호
    • /
    • pp.51-62
    • /
    • 2010
  • The ultrastructures of germ cells and the accessory cells during spermatogenesis and mature sperm ultrastructure in male Gomphina veneriformis, which was collected on the coastal waters of Yangyang, East Sea of Korea, were investigated by transmission electron microscope observations. The morphology of the spermatozoon has a primitive type and is similar to those of other bivalves in that it contains a short midpiece with four mitochondria surrounding the centrioles. Accessory cells are observed to be connected to adjacent germ cells, they contain a large quantity of glycogen particles and lipid droplets in the cytoplasm. Therefore, it is assumed that they are involved in the supplying of the nutrients for germ cell development, while any phenomena associated with phagocytosis of undischarged, residual sperms by lysosomes in the cytoplasm of the accessory cells after spawning was not observed in this study. The morphologies of the sperm nucleus type and the acrosome shape of this species have a cylindrical and modified long cone shape, respectively. In particular, the axial filaments in the lumen of the acrosome, and subacrosomal granular materials are observed in the subacrosomal space between the anterior nuclear fossa and the beginning part of axial filaments in the acrosome. The spermatozoon is approximately $50-55{\mu}m$ in length including a long sperm nucleus (about $7.80{\mu}m$ in length), an acrosome (about $1.13{\mu}m$ in length) and tail flagellum ($40-45{\mu}m$). The axoneme of the sperm tail flagellum consists of nine pairs of microtubules at the periphery and a pair at the center. The axoneme of the sperm tail shows a 9+2 structure. Some charateristics of sperm morphology of this species in the family Veneridae are (1) acrosomal morphology, (2) the number of mitochondria in the midpiece of the sperm,. The axial filament appears in the acrosome as one of characteristics seen in several species of the family Veneridae in the subclass heterodonta, unlikely the subclass pteriomorphia containing axial rod instead of the axial filament. As some characteristics of the acrosome structures, the peripheral parts of two basal rings show electron opaque part (region), while the apex part of the acrosome shows electron lucent part (region). These charateristics belong to the family Veneridae in the subclass heterodonta, unlikely a characteristic of the subclass pteriomorphia showing all part of the acrosome being composed of electron opaque part (region). Therefore, it is easy to distinguish the families or the subclasses by the acrosome structures. The number of mitochondria in the midpiece of the sperm of this species are four, as one of common characteristics appeared in most species in the family Veneridae.

터널 단면적 변화를 고려한 각부보강 영향성 평가 (A Case Study on the effects of Elephant Foot Method considering the rate of Changes in Tunnel Cross Section)

  • 이길용;오현문;조계환;오정호;김종주;김용성
    • 한국지반신소재학회논문집
    • /
    • 제17권1호
    • /
    • pp.111-118
    • /
    • 2018
  • 단층 등 취약지반 조건에서의 터널굴착 시 터널천단 및 측벽변위의 억제를 목적으로 하는 각부보강공이 일반적으로 적용되고 있으며, 터널 단면증가 변화율에 따른 각부보강공 설치각도 및 길이를 고려한 지보안전성 확인을 위한 주요 인자로서 내공변위 천단침하 각부침하 각부축력 등의 여러 응력변위 특성 변수들이 있다. 이러한 굴착중 안전성확인을 위한 변수들에 대한 검토 결과, 우각부 침하영향성이 단면증가율 보다 더 큰 변위경향을 보이는 가장 중요한 중점관리 지배요소로 분석되었으며, 터널단면 증가 변화율에 대한 각 보강공 길이별 축력의 변화관점에서는 큰 연관성을 보여주지 못하는 터널단면 증가율 대비 작은 증가율을 나타냈다. 또한, 각부 보강공 축력의 발생경향은 터널 단면증가율보다 보강공 마찰지지 개념 메커니즘에 따른 거동 영향성을 보여주는 것으로 분석되었다. 본 연구결과, 일정한 길이의 각부 보강공이 선정될 경우 지반불량 구간에서의 터널 단면이 다소 대단면화하여도 무리하게 각부보강공의 길이를 연장시키지 않는 것이 시공성 및 경제성을 고려한 보다 더 합리적인 방법으로 판단된다.

아크릴 및 스테인리스강 시험편의 P-, S-파 속도 산출에 미친 영향 요인 고찰 (A study on the Factors Affected on the P- and S-wave Velocity Measurement of the Acrylic and Stainless Steel Core)

  • 이상규;이태종
    • 지구물리와물리탐사
    • /
    • 제14권4호
    • /
    • pp.305-315
    • /
    • 2011
  • 암석시료에 대한 음파 속도측정의 정확성을 검증하고 정밀한 측정을 위한 기초적인 실험의 일환으로 아크릴과 스테인리스강 재질의 시료에 대하여 길이와 축하중을 달리하여 각각에 대해 3회씩 측정한 총 864 경우에 대하여, 시험편을 통과한 초동 주시를 측정하고 분석하였다. 축하중이 가해진 상태에서의 S-파 측정은 P-파에 비해 측정에 어려움이 있었으며 이에 따라 반복측정, 길이, 축하중에 의한 편차도 S-파가 훨씬 크게 나타났다. 또한, 재질에 따라서는 스테인레스강 시편보다는 아크릴 시편의 초동주시 편차가 약 2배 정도 양호하게 나타났으며 이는 아크릴 시험편의 경우가 트랜스 듀서와 시험편 간의 접촉 coupling이 안정적이며 또한 동일한 시간 분해능이나 유사한 전기적 잡음에 비하여 초동 주시가 길기 때문으로 판단된다. 실험결과, 아크릴 시험편과 스테인리스강 시험편의 탄성파 속도를 측정할 때는 60 ~ 90 mm 정도의 길이를 갖는 시험편을 20 kg (27.7 $N/cm^2$) ~ 30 kg (41.6 $N/cm^2$) 내외의 축하중 하에서 측정하는 것이 가장 좋으며, 스테인리스강 시험편의 S-파 속도는 길이 50 mm 이하의 시험편을 사용하여 측정해야 한다. 이러한 실험 결과는 암석 코어의 속도 측정시 시스템 지연의 측정 및 보정에 활용될 수 있을 것이다.

압축과 휨의 조합하중을 받는 냉간성형강 기둥의 내력성능 (Load Carrying Capacities of Cold Formed Steel Structural Columns subject to Combined Axial Load and Bending Moment)

  • 신태송
    • 한국강구조학회 논문집
    • /
    • 제17권1호통권74호
    • /
    • pp.83-92
    • /
    • 2005
  • 본 논문은 압축과 모멘트 조합하중을 받는 냉간성형강 기둥의 내력성능을 평가하는데 목적이 있다. 단면은 춤이 90, 150 mm이고 웨브에 엠보싱이 있는 립 ㄷ형강이다. 부재길이와 단부모멘트비를 변수로 하였고, 편심압축력을 가력하여 총 24개 실물실험을 수행하였다. 미국 AISI와 유럽 EC3 기준의 특징을 체계적으로 분석하였고, 실험결과와 기준 산정결과를 비교하였다. 두 기준 모두 합리적임을 알 수 있었다.