• 제목/요약/키워드: Axial Flux

검색결과 317건 처리시간 0.035초

반경방향-축방향 일체형 4극 전자기 베어링의 설계 (II) - 바이어스 자속 공유형 - (Design of Combined Radial and Axial 4-pole Electromagnetic Bearing (II) - with Coupled Bias Flux -)

  • 김하용;김승종
    • 대한기계학회논문집A
    • /
    • 제29권12권
    • /
    • pp.1567-1573
    • /
    • 2005
  • This paper introduces a new active magnetic bearing(AMB) that can provide both radial and axial control functions in one bearing unit without axial disk. It has a structure of double four-pole AMB or a four-pole AMB where each core is split into two axially. The cores have two kinds of coil winding; they independently generate fluxes on the planes perpendicular or parallel to the shaft. For the radial control action, it works just like a conventional four-pole AMB. Meanwhile, for the axial control, it uses the Lorentz force generated by the interaction of the bias flux for radial control and the axial control flux. In this paper, the proposed structure, principle, and design process based on magnetic flux analysis are introduced, and its feasibility is experimentally verified by using a simple PD control algorithm with a feedforward loop to compensate the coupled flux effect.

Study on dryout heat flux of axial stratified debris bed under top-flooding

  • Wenbin Zou;Lili Tong;Xuewu Cao
    • Nuclear Engineering and Technology
    • /
    • 제56권2호
    • /
    • pp.636-643
    • /
    • 2024
  • The coolability of the debris bed with a simulant of solidified corium is experimentally studied, focusing on the effects of the structure of the axial stratified debris bed on the dryout heat flux (DHF). DHF was obtained for the four structures with different particle sizes for the axial stratified debris bed under top flooding. The experimental results show that the dryout position of the axial stratified debris bed is formed at the stratified interface indicated by the temperature rise, and the DHF of the axial stratified bed is much lower than that of the homogeneous bed packed with the upper small particles. To predict the dryout heat flux of the stratified debris beds, by considering the properties of the mixed area, a one-dimensional dryout heat flux model of the porous medium is derived from a water and vapor momentum equation for porous medium, two-phase permeability modifications, interfacial drag, and the correlation between capillary pressure and liquid saturation and verified with the experimental data. The modified model can give reasonable results under different structures.

축 자속 영구자석 발전기의 체적에 따른 성능 비교 (Performance Comparison of Axial Flux Permanent Magnet Generator according to Volume)

  • 장석명;구민모;박유섭;최장영;이용복;윤기갑
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1071-1072
    • /
    • 2011
  • The axial flux machine has higher power density than conventional radial flux machine, so it is widely applied to various industrial area, for instance, low speed wind power generator. For the conventional radial flux machine, 2D finite element method (FEM) is generally applied, but axial flux machine has to employ 3D FEM with long analysis time due to its own structural characteristic. This paper deals with the performance comparison of axial flux machine according to volume.

  • PDF

횡자속형 2중 공극 영구자석 동기발전기의 마그네트 형상설계 (Design of Magnet Shape for Axial-Flux Type Permanent-Magnet Synchronous Generator with Dual Air-Gap)

  • 최경호;김경식;진명철;황돈하;배성우;김동희;노채균
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.828-831
    • /
    • 2003
  • This paper presents a novel design technique and characteristic analysis of Magnet for dual air-gap axial-flux type permanent-magnet synchronous generator. The process of magnet design is applied to the motor design and steady state analysis considering output voltage waveforms and magnetic flux waveforms. Design and construction of an axial-flux permanent-magnet generator with power output at 60 [Hz], 300[r/min] is introduced. Finite-element (FE) method is applied to analyze magnet shape characteristics. The results of FE analysis show generator is feasible for use with dual air-gap axial-flux permanent- magnet synchronous generator.

  • PDF

축방향 누설자속 측정에 의한 유도전동기의 회전자 결함검출에 관한 연구 (A Study of Rotor Fault Detection for the Induction Motor Using Axial Leakage Magnetic Flux)

  • 신대철;김영환
    • 조명전기설비학회논문지
    • /
    • 제20권1호
    • /
    • pp.132-137
    • /
    • 2006
  • 유도전동기에 대한 결함 검출의 도구로서 축방향 누설자속 측정 방법을 사용할 수 있는가를 평가하고 전동기고장 검출에 관한 진단 알고리즘을 개발하기 위한 회전자에 관한 2번째 논문이다. 결함 검출을 위해 운전 중인 전동기의 끝단에 설치된 자속코일 센서로 누설자속 신호를 수집하며 전동기의 각종 결함을 검출하기 위해 시간과 주파수 영역에서 신호를 분석하였다. 센서 신호 형상이 전동기 각각의 결함에 대해 시간과 주파수 영역에서 해석하였다. 전동기의 회전자 관련 격함인 회전자봉 파손, 단락환 파손 및 회전자 편심이 축방향에서 측정된 고해상도의 스펙트럼으로부터 검출할 수 있는 방법을 확인하였다. 누설자속 스펙트럼으로부터 특정 주파수와 회전자봉 통과주파수의 측파대를 분석함으로서 회전자 결함을 검출하는 방법을 알았다. 또 유도전동기에 대하여 축방향 누설자속 측정을 위한 최적의 자속코일센서 및 측정시스템을 검증하고 회전자 결함을 검출하기 위한 방법을 개발하였다.

AFPM 전동기의 오버행 효과에 관한 연구 (Overhang Effect on the Axial Flux Permanent Magnet Motor)

  • 우동균
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.769-772
    • /
    • 2016
  • In this paper, the overhang structure was applied to the axial flux permanent magnet (AFPM) motor. This paper describes the overhang effect in the AFPM motor. Moreover, the overhang effect was analyzed according to the different overhang length and an optimal overhang structure was proposed. Finally, the proposed structure was applied to design, analysis and experiment of prototype motors. Through the comparison between 3D finite element analysis results and experimental ones, the validity of proposed structure is clarified.

50Wh급 배터리 충전을 위한 휴대용 자가발전시스템 연구 (A Study of a Manual Generator System for 50Wh Battery Charge)

  • 이지영;구대현;한충규
    • 전기학회논문지
    • /
    • 제61권2호
    • /
    • pp.223-230
    • /
    • 2012
  • This paper deals with an design of axial flux electric machine which is a key element for a compact size in a portable and manual generator system. It is expected that the generator system with an axial flux electric machine is more light and has higher efficiency than other types of generator systems. And it is used the soft magnetic composite core instead of silicon steel core in the axial flux electric machine for more compact size. The weight and efficiency of the generator system are the main keys to select the value of design variables. In this paper, the overall design process to meet the design goals, and the design results are presented with experiment results.

Design and Performance Analysis of Coreless Axial-Flux Permanent-Magnet Generator for Small Wind Turbines

  • Chung, Dae-Won;You, Yong-Min
    • Journal of Magnetics
    • /
    • 제19권3호
    • /
    • pp.273-281
    • /
    • 2014
  • This paper presents an innovative design for a low-speed, direct-drive, axial-flux permanent-magnet (AFPM) generator with a coreless stator and rotor that is intended for application to small wind turbine power generation systems. The performance of the generator is evaluated and optimized by means of comprehensive 3D electromagnetic finite element analysis. The main focus of this study is to improve the power output and efficiency of wind power generation by investigating the electromagnetic and structural features of a coreless AFPM generator. The design is validated by comparing the performance achieved with a prototype. The results of our comparison demonstrate that the proposed generator has a number of advantages such as a simpler structure, higher efficiency over a wide range of operating speeds, higher energy yield, lighter weight and better power utilization than conventional machines. It would be possible to manufacture low-cost, axial-flux permanent-magnet generators by further developing the proposed design.

2중 공극형 횡자속 영구자석 동기발전기 설계 및 특성분석 (Design and Characteristics Analysis of Dual Air-Gap Axial-Flux type Permanent-Magnet Synchronous Generator)

  • 배성우;황돈하;강도현;김용주;최경호;김동희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1063-1066
    • /
    • 2003
  • This paper presents the design and characteristics analysis of axial-flux permanent-magnet (PM) synchronous generator of two air-gap. Dual axial-flux type PM synchronous generator commonly appears in applications where the generator axial dimension is more limited than the radial dimension. The strengths of dual axial-flux generator include ; (1) by employing two air-gaps, the rotor-stator attractive forces are balanced and no net axial or thrust load appeals on the generator hearings ; (2) heat produced by the stator windings appears on the outside of the generator, making it relatively easy to remove, and so on. In this paper, the simple magnetic equivalent circuit approach is used for initial design iteration, and the finite-element method is applied to analyze the detailed characteristics. The test results of driving characteristics are presented as well. The results are very similar to predicted performance of design.

  • PDF

축방향 누설자속 측정에 의한 유도전동기의 고정자 결함검출에 관한 연구 (A Study of Stator Fault Detection for the Induction Motor Using Axial Magnetic Leakage Flux)

  • 신대철;김영환
    • 조명전기설비학회논문지
    • /
    • 제19권8호
    • /
    • pp.131-137
    • /
    • 2005
  • 본 논문은 유도 전동기에 대한 상태 모니터링 시스템의 도구로서 축방향 누설자속 측정 방법을 사용할 수 있는가를 평가하고 전동기에 대한 진단 알고리즘을 개발하는 것이다. 결함검출을 위해 전동기를 정지시키지 않고 전동기의 코일단에 설치된 자속코일로 누설자속 신호를 수집하여 전동기의 각종 결함을 검출하기 위해 시간과 주파수영역으로 신호를 분석한다. 전동기 각각의 결함에 대해 시간과 주파수 영역에서 특정 신호 현상이 검출되었다. 전원전압 불평형과 고정자 권선의 선간 단락은 축방향에서 측정된 고해상도의 누설자속 스펙트럼으로부터 특정 측대파와 회전자봉 통과주파수의 측대파를 분석함으로서 결함을 검출할 수 있다. 주파수 영역에서의 스펙트럼이 모니터링 목적으로 더욱 유용하다는 결론을 얻었다. 본 논문에서는 유도 전동기의 축방향 누설자속 측정이 진단 방법으로서 적합한 도구임을 증명하고 결함을 검출하기 위한 알고리즘을 개발하였다.