• 제목/요약/키워드: Averaging model

검색결과 301건 처리시간 0.028초

시비율 비대칭 하프 브릿지 컨버터의 소신호 해석 및 전압 제어 루우프 설계 (Small-Signal Modeling and Control Design of Asymmetrical Half Bridge DC/DC Converter)

  • 방상현;임원석;강용한;최병조
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.538-541
    • /
    • 2002
  • Dynamic analysis and compensation design for an asymmetrical half bridge do-dc converter are presented. A small-signal model is developed using the averaging method. Based on the proposed small-signal average model, the open loop transfer functions of the power stage were obtained and used for the compensation design. All theoretical predictions are validated by experiments on a prototype converter.

  • PDF

전류제어 능동 클램프 포워드-플라이백 컨버터의 동특성 해석 및 제어회로 설계 (Dynamic Analysis and Control Design of Current-Mode Controlled Active-Clamp Forward-Flyback Converter)

  • 임원석;강용한;최병조
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.374-377
    • /
    • 2002
  • This paper presents dynamic analyses and control design of the current-mode controlled active-clamp forward-flyback converter. The circuit averaging technique is used to extract the small-signal circuit model for the power stage From the small-signal circuit model of the power stage, the open-loop transfer functions are derived and used for the compensation design. The analysis results are verified using an experimental converter that delivers a 3.3V/10A output from a $40\~60V$ input source.

  • PDF

A Cross Regulation Analysis for Single-Inductor Dual-Output CCM Buck Converters

  • Wang, Yao;Xu, Jianping;Zhou, Guohua
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1802-1812
    • /
    • 2016
  • Cross regulation is a key technical issue of single-inductor multiple-output (SIMO) DC-DC converters. This paper investigates the cross regulation in single-inductor dual-output (SIDO) Buck converters with continuous conduction mode (CCM) operation. The expressions of the DC voltage gain, control to the output transfer function, cross regulation transfer function, cross coupled transfer function and impedance transfer function of the converter are presented by the time averaging equivalent circuit approach. A small signal model of a SIDO CCM Buck converter is built to analyze this cross regulation. The laws of cross regulation with respect to various load conditions are investigated. Simulation and experiment results verify the theoretical analysis. This study will be helpful for converter design to reduce the cross regulation. In addition, a control strategy to reduce cross regulation is performed.

난류확산연소에서의 Conditional Moment Closure Modeling (Conditional Moment Closure Modeling in Turbulent Nonpremixed Combustion)

  • 허강열
    • 한국연소학회지
    • /
    • 제5권2호
    • /
    • pp.9-17
    • /
    • 2000
  • A brief introduction is given on the conditional moment closure model for turbulent nonpremixed combustion. It is based on the transport equations derived through a rigorous mathematical procedure for the conditionally averaged quantities and appropriate modeling forms for conditional scalar dissipation rate, conditional mean velocity and reaction rate. Examples are given for prediction of NO and OR in bluffbody flames, soot distribution in jet flames and autoignition of a methane/ethane jet to predict the ignition delay with respect to initial temperature, pressure and fuel composition. Conditional averaging may also be a powerful modeling concept in other approaches involved in turbulent combustion problems in various different regimes.

  • PDF

불연속 전류모드에서의 다상 교호 강압컨버터의 정상상태 해석 및 모델링 (Modeling and Steady-state Analysis of the Multi-Phase Interleaved Buck converter in Discontinuous Inductor Current Mode)

  • 장성동;장은승;정세교;신휘범;이현우
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.506-510
    • /
    • 2004
  • A multi-phase interleaved buck converter is used to reduce current ripples and filter size of a power supply. This paper addresses the modelling and steady-state analysis of the multi-phase interleaved buck converter operated in discontinuous inductor current mode. The model is derived using an averaging technique in steady state. The do voltage ratio and the range of the discontinuous inductor current mode(DICM) and the continuous output current mode(COCM) are derived from the averaged state-space model. In addition, the efficiency is investigated according to the number of phase.

  • PDF

실린더형 패드와 평판 시험편간 프레팅 피로의 접촉폭 크기효과에 관한 평가 (Estimation on a Contact Size Effect in Fretting Fatigue Between Cylindrical Pad and Flat Specimen)

  • 김진광;조상봉
    • 한국정밀공학회지
    • /
    • 제25권6호
    • /
    • pp.116-125
    • /
    • 2008
  • In general, fretting is a contact damage process due to micro-slip associated with small amplitude oscillatory movement between two surfaces in contact. Previous studies in fretting fatigue have observed a contact size effect related to contact width. The volume-averaging method of theoretically predicted contact stress fields was required to emulate experimental trends and to predict the observed contact size effects. This contact size effect is captured by the mean values of stresses and strains at the element integration points of FE model and two critical plane models (SWT, FS) in the present paper. It is shown that crack nucleation and fretting fatigue life can be predicted by the FE-based critical plane models.

필드모델에서 연료소모에 기초한 화학적 화염높이 산정 (Estimation of Chemical Flame Height based on Fuel Consumption in a Fire Field Model)

  • 김성찬
    • 한국화재소방학회논문지
    • /
    • 제30권2호
    • /
    • pp.92-97
    • /
    • 2016
  • 본 연구는 필드모델에서 소모된 연료에 기초하여 화학적 화염높이를 산정하기 위한 방법을 검토하고자 한다. 높이 방향으로 HRRPUL의 누적값과 연료농도에 따른 계산 알고리즘을 FDS 해석결과에 적용하였으며 평균화학적 화염높이는 알고리즘을 적용한 순간화염높이의 시간평균을 통해 산정하였다. 연료농도에 기초한 평균화염높이는 HRRPUL의 누적값에 의해 계산된 화염높이와 10% 이내의 상향예측범위에서 일치된 결과를 보였다. 이러한 연구는 전산화재해석모델에서 정량적인 화염높이를 산정하고 보다 상세한 화재거동특성을 이해하는데 기여하고자 한다.

배터리 에너지 저장 장치를 위한 2단 DC-DC-AC 컨버터의 모델링 방법 (Modeling and Control of a Two-Stage DC-DC-AC Converter for Battery Energy Storage System)

  • 현동엽;정석언;현동석
    • 전력전자학회논문지
    • /
    • 제19권5호
    • /
    • pp.422-430
    • /
    • 2014
  • This study proposes a small-signal model and control design for a two-stage DC-DC-AC converter to investigate its dynamic characteristics in relation to battery energy storage system. When the circuit analysis of the two-stage DC-DC-AC converter is attempted simultaneously, the mathematical procedure of deriving the dynamic equation is complex and difficult. The main idea of modeling the two-stage DC-DC-AC converter states that this topology is separated into a bidirectional DC-DC converter and a single-phase inverter with an equivalent current source corresponding to that of the inverter or converter. The dynamic equations for the separated converter and inverter are then derived using the state-space averaging technique. The procedures of building the small-signal model of the two-stage DC-DC-AC converter are described in detail. Based on the derived small-signal model, the individual controllers are designed through a frequency-domain analysis. The simulation and experimental results verify the validity of the proposed modeling approach and controller design.

벽면 충돌 난류 확산화염의 특성 (The Characteristics of Turbulent Diffusion Flame Impinging on the Wall)

  • 박용열;김호영
    • 대한기계학회논문집B
    • /
    • 제23권2호
    • /
    • pp.175-184
    • /
    • 1999
  • A theoretical study on the turbulent round jet diffusion flame impinging on the wall was carried out to predict the characteristics and structure of Impinging jet flame and heat transfer to the wall. Finite chemistry via Arrhenius equation and eddy dissipation model was adopted as a combustion model, and the Favre averaging and $k-{\varepsilon}$ model were Introduced In the theoretical modeling. The SIMPLE algorithm was applied to the calculation. All the transport properties were considered as the variable depending on the temperature and composition. For the parametric study, the distance from nozzle to impinging wall and Reynolds number at nozzle exit were chosen 88 the major parameters. As the results of the present study, the characteristics of flow fields, the distributions of main variables and each chemical species and the flame shapes were obtained. The heat transfer rate from the flame to the wall and the effective heating area were calculated to investigate the Influences of the major parameters on the heat transfer characteristics.

저항물체 배후의 이차원 후류에 관한 대격자 수치모형 (A Numerical Model of Large Scale Grid for Two-Dimensional Wake behind Bodies)

  • 박일흠;이종섭;이문옥
    • 한국해안해양공학회지
    • /
    • 제10권2호
    • /
    • pp.83-92
    • /
    • 1998
  • 대격자망 수치모형에서 저항물체에 의한 유수저항을 평가하기 위하여, 항력으로부터 유도된 drag stress를 수심적분된 Reynolds 방정식에 도입하였다. 그리고, 해석해가 존재하는 조건에 대한 다양한 수치실험을 통하여 본 모형의 적용성 및 문제점을 검토하였다. 단일물체의 경우, 수치해는 해석해에 대하여 유속의 크기에 있어서$\pm$10% 정도의 오차범위를 나타내는 좋은 일치를 보였으며 후류폭의 크기도 전 경우에 있어서 해석해와 잘 일치 하였다. 또한, 열을 이룬 물체에 대한 항력계수와 와동점성계수가 정확하게 결정된다면, 본 모형은 열을 이룬 물체 배후에서 평균류의 흐름분포를 평가하는 데 효율적으로 이용될 수 있을 것이다.

  • PDF