• Title/Summary/Keyword: Average wind velocity

Search Result 93, Processing Time 0.025 seconds

Variations of the Wind-generated Wave Characteristics around the Kyung-gi Bay, Korea (경기만 근해에서 풍파의 특성 변화)

  • Kang, Ki-Ryong;Hyun, Yu-Kyung;Lee, Sang-Ryong
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.12 no.4
    • /
    • pp.251-261
    • /
    • 2007
  • The wind-wave interaction around the Kyung-gi Bay, Korea, was studied using the observed data from ocean buoy at DeuckJeuck-Do from Jan. to Dec., 2005, and from waverider data at KeuckYeulBee-Do on Mar. 19-26 and May 23-28, 2005. Wind-driven surface waves and wave-driven wind speed decrease were estimated from the ocean buoy data, and the characteristics of wave spectrum response were also investigated from the waverider data for the wave developing and calm stages of sea surface, including the time series of spectrum pattern change, frequency trend of the maximum energy level and spectrum slope for the equilibrium state range. The wind speed difference between before and after considering the wave effect was about $2ms^{-1}$ (wind stress ${\sim}0.1Nm^{-2}$) for the wind speed range $5-10ms^{-1}$ and about $3ms^{-1}$ (wind stress ${\sim}0.4Nm^{-2}$) for the wind speed range $10-15ms^{-1}$. Correlation coefficient between wind and wave height was increased from 0.71 to 0.75 after the wave effect considered on the observed wind speed. When surface waves were generated by wind, the initial waves were short waves about 4-5 sec in period and become in gradual longer period waves about 9-10 sec. For the developed wave, the frequency of maximum energy was showed a constant value taking 6-7 hours to reach at the state. The spectrum slope for the equilibrium state range varied with an amplitude in the initial stage of wave developing, however it finally became a constant value 4.11. Linear correlation between the frictional velocity and wave spectrum for each frequency showed a trend of higher correlation coefficient at the frequency of the maximum energy level. In average, the correlation coefficients were 0.80 and 0.82 for the frequencies 0.30 Hz and 0.35 Hz, respectively.

Synoptic Meteorological Classification of the Days on Which Asthma Deaths Occurred Due to High PM10 Concentrations in Seoul (서울지역 미세먼지 고농도에 따른 천식사망자 사례일의 종관기상학적 분류)

  • Choi, Yun-Jeong;Park, Jong-Kil;Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.26 no.2
    • /
    • pp.159-172
    • /
    • 2017
  • Asthma deaths in Seoul peaked on the third, fifth, and second days after the PM concentration exceeded the daily average concentration standard. We classified the synoptic meteorological conditions, based on the days involving such cases, into three categories. Type 1 included the meteorological condition likely to cause high air pollution concentrations in the leeward region, the dominant wind direction of which is the northwest. Type 2 included the meteorological condition likely to cause high air pollution concentrations due to the weak wind velocity under stable atmospheric conditions. Type 3 was when the passage low atmospheric pressure and the expansion of high atmospheric pressure occurred at the rear, indicating a meteorological condition likely to cause high air pollution, in certain regions. Type 1 occurred 11 times, with high concentrations of over $100{\mu}g/m^3$ being observed in the southeastern part of Seoul. Type 2 occurred 24 times, often accompanied by a PM concentration of $100{\sim}400{\mu}g/m^3$. Type 3 occurred 11 times, and was accompanied by several days of yellow dust that accounted for the highest concentrations.

Analysis on Residential Micro Climate of the Urban Heat Island and Oxygen Concentration in Winter (겨울철 열섬 및 산소농도의 측정을 통한 주거지별 국지기후의 특성분석)

  • Hwang Jee Wook;Kim So Chong
    • Journal of Environmental Science International
    • /
    • v.13 no.12
    • /
    • pp.1023-1032
    • /
    • 2004
  • Rapid progress in urbanization has resulted in a change of the micro climate, especially in the urban area. In order to investigate the phenomenon of the heat island in the residential micro climate, a field survey was carried out by 4 sets of the residential type in Jeonju under typical winter synoptic condition. As analytic methode, it is used the comparison on the relation of the Land-to-Coverage Rate to Heat Island and Oxygen Concentration. And as a key question it is asked how stable characteristics of the micro climate will result from the survey of the Heat Island and the Oxygen Concentration, used as indicator. To ensure the trustworthy result of research, it is calculated the critical influence of the wind velocity and the Land-to-Covearage Rate. As a result of comparative analysis, it could be confirmed that the local temperatures in all sets of the residential type were higher than the average temperature in Jeonju. But the housing type A 'exclusive use for housing zone' has relativly the most stable and best living condition. On the contrary the residential type B and D has the worst toward the oxygen concentration in the time zone 9-12 a.m., which didn't reach the minimum of the oxygen concentration $20.5{\%}.$ It means that the higer the development and population density is, the worse is the situation of the Quality of Life in the residential types in accordance with the heat island and oxygon con­centration.

A Study on the Characteristics of Cylinder Wake Placed in Thermally Stratified Flow (IV) -On the Cylinder Wake with Various Heating Rates- (열성층유동장에 놓인 원주후류의 특성에 대한 연구 (4) -가열량의 변화에 따른 원주후류에 대하여-)

  • 김경천;정양범
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.5
    • /
    • pp.1340-1350
    • /
    • 1995
  • The effects of thermal stratification on the flow past a heated circular cylinder with various heating rates were examined in a wind tunnel. Turbulent intensities, r.m.s.values of temperature and turbulent convective heat flux distributions in the cylinder wakes with and without thermal stratification were measured by using a hot-wire and cold-wire combination probe. The phase averaging method was also used to estimate coherent contributions to the turbulent flow field in the near wake. The results show that the scalar mixing process is very different according to the mean temperature fields especially in the upper part of the wake. The coherent structure of the temperature field makes a large contribution to the time mean value like velocity components. However, the coherency of the temperature fluctuation is very different with the change of mean temperature fields, though the velocity coherent motions are quite similar in all experimental conditions.

Potential Source of PM10, PM2.5, and OC and EC in Seoul During Spring 2016 (2016년 봄철 서울의 PM10, PM2.5 및 OC와 EC 배출원 기여도 추정)

  • Ham, Jeeyoung;Lee, Hae Jung;Cha, Joo Wan;Ryoo, Sang-Boom
    • Atmosphere
    • /
    • v.27 no.1
    • /
    • pp.41-54
    • /
    • 2017
  • Organic carbon (OC) and elemental carbon (EC) in $PM_{2.5}$ were measured using Sunset OC/EC Field Analyzer at Seoul Hwangsa Monitoring Center from March to April, 2016. The mean concentrations of OC and EC during the entire period were $4.4{\pm}2.0{\mu}gC\;m^{-3}$ and $1.4{\pm}0.6{\mu}gC\;m^{-3}$, respectively. OC/EC ratio was $3.4{\pm}1.0$. The average concentrations of $PM_{10}$ and $PM_{2.5}$ were $57.4{\pm}25.9$ and $39.7{\pm}19.8{\mu}g\;m^{-3}$, respectively, which were detected by an optical particle counter. The OC and EC peaks were observed in the morning, which were impacted by vehicle emission, however, their diurnal variations were not noticeable. This is determined to be contributed by the long-range transported OC or secondary formation via photochemical reaction by volatile organic compounds at afternoon. A conditional probability function (CPF) model was used to identify the local source of pollution. High concentrations of $PM_{10}$ and $PM_{2.5}$ were observed from the westerly wind, regardless of wind speed. When wind velocity was high, a mixing plume of dust and pollution during long-range transport from China in spring was observed. In contrast, pollution in low wind velocity was from local source, regardless of direction. To know the effect of long-range transport on pollution, a concentration weighted trajectory (CWT) model was analyzed based on a potential source contribution function (PSCF) model in which 75 percentiles high concentration was picked out for CWT analysis. $PM_{10}$, $PM_{2.5}$, OC, and EC were dominantly contributed from China in spring, and EC results were similar in both PSCF and CWT. In conclusion, Seoul air quality in spring was mainly affected by a mixture of local pollution and anthropogenic pollutants originated in China than the Asian dust.

A Study of Air Pollutants Dry Deposition (대기오염물질의 건성침적에 관한 연구)

  • Lee, Chi-Young;Kang, Dong-Ku
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.64-68
    • /
    • 2003
  • Measurement of dried deposition for air pollutant was investigated in Gwang-ju Health college area for a year. The average value of air pollutants was investigated three times a month. Measured heavy metals and concentration of mass are not corelated. Heavy metals were thrown up air as state of large particles and they were moved by wind. Deposition of heavy metals and deposition velocities were high in the order of Fe > n > Cu > Pb > Cr and Pb > Fe > Cr > Zn > Cu, respectively. The pattems of deposition velocity of heavy metals for a year were much the same as each other except that Pb is faster than others.

Measutements of the ground-level ozone in a rural area of Chongwon, Korea (충북 청원군에서 관측된 지표면 부근의 오존)

  • 윤마병;정용승
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.1
    • /
    • pp.85-93
    • /
    • 1995
  • Measurements of ground level ozone concentrations were made in a rural area of Chongwon (Choongbook Province) from June 1993 to July 1994. High values frequently exceeding 100 ppb (ambient air qualyty standard of Korea) were recorded. High ozone concentrations in the boundary layer were primarily correlated with the several meteorological parameters in warm seasons: pressure, radiation, temperature, precipitation and wind velocity. The annual average concentration of ozone at Chongwon was 17ppb, and this value was relatively higher than those for other cities in Korea. O$\_$3/ concentrations were observed to increase when the ridge of a surface anticyclone was passing over the region, and maximum values(.geq.100 ppb) were observed on the rear sides of high pressure centers and in the warm sectors of cyclones(well head of cold fronts). The ozone concentrations had a negative correlation with the concentration of primary pollutants(e.g., total hydrocarbons).

  • PDF

Numerical Study of Convective Heat Transfer in an Inclined Porous Media (경사진 다공성물체내에서의 자연대류에 관한 수치해석)

  • Mok I. K.;Seo J. Y.;Kim C. B.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.15 no.4
    • /
    • pp.388-395
    • /
    • 1986
  • Numerical solutions of two-dimensional, steady, and natural are investigated in a confined rectangular cavity with porous media. The saturated fluid is bounded by two isothermal vertical walls at different temperatures and two adiabatic horizontal walls. Governing equations are numerically solved by finite difference method with the up wind scheme. Distributions of streamline and temperature we. predicted for aspect ratios ranging from 0.1 to 1.0, Rayleigh numbers 50 to $10^4$, and tilt angles $0^{\circ}\;to\;60^{\circ}$. Representative plots of temperature and velocity field according to tilt angle are presented. The effects of aspect ratio, Rayleigh number, and tilt angle on local and average Nusselt numbers are obtained. The optimum conditions for maximum Nusselt number are also presented with tilt angles.

  • PDF

Status of PM10 as an air pollutant and prediction using meteorological indexes in Shiraz, Iran

  • Masoudi, Masoud;Poor, Neda Rajai;Ordibeheshti, Fatemeh
    • Advances in environmental research
    • /
    • v.7 no.2
    • /
    • pp.109-120
    • /
    • 2018
  • In the present study research air quality analyses for $PM_{10}$, were conducted in Shiraz, a city in the south of Iran. The measurements were taken from 2011 through 2012 in two different locations to prepare average data in the city. The averages concentrations were calculated for every 24 hours, each month and each season. Results showed that the highest concentration of $PM_{10}$ occurs generally in the night while the least concentration was found at the afternoon. Monthly concentrations of $PM_{10}$ showed highest value in August, while least value was found in January. The seasonal concentrations showed the least amounts in autumn while the highest amounts in summer. Relations between the air pollutant and some meteorological parameters were calculated statistically using the daily average data. The wind data (velocity, direction), relative humidity, temperature, sunshine periods, evaporation, dew point and rainfall were considered as independent variables. The relationships between concentration of pollutant and meteorological parameters were expressed by multiple linear regression equations for both annual and seasonal conditions SPSS software. RMSE test showed that among different prediction models, stepwise model is the best option.

A Study on the Control of the Temperature and Relative Humidity in Greenhouse by Adjusting the Amount of Natural Ventilation and Fog Spray Quantity (자연환기량과 포그분무량 조절에 의한 온실 온습도의 동시제어 기법 연구)

  • Kim, Youngbok;Sung, Hyunsoo;Hwang, Seungjae;Kim, Hyeontae;Ryu, Chanseok
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.5
    • /
    • pp.31-50
    • /
    • 2016
  • To develope a greenhouse fog cooling system to control the temperature and relative humidity simultaneously to the target value, a theoretical analysis and experiments were done. The control process includes the measuring of environmental variables, setting and coding of the water and heat balance equations to maintain the target temperature and relative humidity in greenhouse, calculating of the open level of the greenhouse roof window that governs the natural ventilation and spray water quantity, and operating of the motor to open/close the roof window and pump to spray for water. The study results were shown to be very good because the average air temperature in the greenhouse was kept to be about $28.2^{\circ}C$ with the standard deviation of about $0.37^{\circ}C$ compared to the target temperature of $28^{\circ}C$ and the average relative humidity was about 75.2% compared to the target relative humidity was 75% during the experiments. The average outside relative humidity was about 41.0% and the average outside temperature was $27.2^{\circ}C$ with the standard deviation of about $0.54^{\circ}C$. The average solar intensity in the greenhouse was 712.9 W. The wind velocity of outside greenhouse was 0.558 m/s with the standard deviation of 0.46 m/s.