• 제목/요약/키워드: Average turbidity

검색결과 141건 처리시간 0.026초

Model Tree기법을 이용한 정수처리공정에서의 응집/침전 효율 예측에 관한 연구 (Establishment of the Refined Model for Prediction of Flocculation/Sedimentation Efficiency Using Model Tree Technique)

  • 박노석;박상영;김성수;정남정;이선주
    • 상하수도학회지
    • /
    • 제20권6호
    • /
    • pp.789-797
    • /
    • 2006
  • This study was conducted to establish the refined model for prediction of flocculation/sedimentation efficiency in factual drinking water treatment plants using model tree technique. In order to carry out machine leaning for determining each linear model, five parameters; time, coagulant dose, raw water turbidity, SCD and conductivity, which were measured and collected from the field (K_DWTP), were selected and used. The existing analytical models developed by previous researchers were used only to examine closely the mechanism of flocculation rather than to apply it for practical purpose. The refined model established using model tree technique in this study could predict the factual sedimentation efficiency accurately (below 9% of average absolute error). Also, in aspect of engineering convenience, without any additional manipulation of parameters, it can be applied to practical works.

Advanced Water Treatment by Tubular Alumina Ceramic Ultrafiltration: Effect of Periodic Water-back-flushing Period

  • Park, Jin-Yong;Lee, Song-Hui
    • Korean Membrane Journal
    • /
    • 제11권1호
    • /
    • pp.15-20
    • /
    • 2009
  • The periodic water-back-flushing using permeate water was performed to minimize membrane fouling and to enhance permeate flux in tubular ceramic ultrafiltration (UF) system for Gongji stream water treatment in Chuncheon city. The filtration time (FT), which was the water-back-flushing period, 2 min with periodic 15 sec water-back-flushing showed the highest value of dimensionless permeate flux ($J/J_o$), and the lowest value of resistance of membrane fouling ($R_f$), and we acquired the highest total permeate volume ($V_T$) of 6.35 L. Consequently FT 2 min at back-flushing time (BT) 15 sec could be the optimal condition in advanced UF water treatment of Gongji stream. Then the average rejection rates of pollutants by our tubular ceramic UF system were 99.4% for Turbidity, 31.8% for $COD_{Mn}$, 22.6% for $NH_3$-N and 65.9% for T-P.

세라믹 한외여과 및 광촉매 혼성공정에 의한 고탁도 원수의 고도정수처리: 2. 광산화와 흡착의 영향 (Advanced Water Treatment of High Turbidity Source by Hybrid Process of Ceramic Ultrafiltration and Photocatalyst: 2. Effect of Photo-oxidation and Adsorption)

  • 고사총;박진용
    • 멤브레인
    • /
    • 제21권2호
    • /
    • pp.201-211
    • /
    • 2011
  • 본 연구에서는 정수처리용 세라믹 한외여과 빛 광촉매의 혼성공정에서 휴믹산 농도 및 광산화, 흡착의 영향을 알아보았다. 휴믹산 농도 각각 2mg/L와 4 mg/L 일 때 UF 단독 공정 및 광촉매를 투입한 공정, UV를 조사한 공정을 막오염에 의한 저항$(R_f)$ 및 투과선속(J), 총여과부피 $(V_{\Upsilon})$ 측면에서 고찰하였다. 휴믹산 농도가 낮아질수록 $R_f$는 급격히 감소하고 J는 증가하여, 휴믹산 농도 2 mg/L에서 $V_{\Upsilon}$는 가장 높았다. 탁도의 평균 처리효율은 휴믹산 농도가 증가할수록 감소하였으나, 4 mg/L에서 휴믹산의 처리효율이 가장 높았다. 이러한 결과는 낮은 휴믹산 농도에서 휴믹산 대부분이 분리막에 의해 제거되고 막을 통과한 일부 휴믹산은 광촉매에 흡착 산화되어, 처리수의 수질이 휴믹산 2 mg/L 와 4 mg/L 에서 거의 같고 원수의 수질은 4 mg/L에서 더 높기 때문이다. 광산화와 흡착의 영향 실험에서 UF + $TiO_2$ + UV 공정의 J가 가장 높게 유지되어, 180분 운전 후 $V_{\Upsilon}$가 가장 높았다. 휴믹산 및 탁도의 처리효율을 비교한 결과, 휴믹산 농도가 2 mg/L 에서 4mg/L로 증가하였을 때 광산화 보다 광촉매 흡착이 더 주요한 역할을 하였다.

분사식 행망의 개발에 관한 연구 ( 2 ) - 분사식 개량조개 시험행망의 현장실험 - (Development of Hydraulic Jet Dredge ( 2 ) - Field Experiment of Hydraulic Jet Dredge for Catching Surf Clam -)

  • 고관서
    • 수산해양기술연구
    • /
    • 제27권4호
    • /
    • pp.266-277
    • /
    • 1991
  • 분사류의 해저 굴삭성능을 이용하여 해저의 모래속에 서식하고 있는 개량조개, Mactra chinensis(PHILIPPI)를 어획하기 위해, 전보의 분사노즐의 모래면 굴삭성능에 관한 수조실험 결과를 근거로 분사식 항망 시험어구를 제작하고, 군산 앞바다의 개량조개 어장에서 1990년 10월 5일에서 10월 30일까지 현장실험을 실시한 결과는 다음과 같다. 1) 시험어구의 굴삭깊이는 분사속도 1200cm/s일 때 10~11cm, 1350cm/s일 때 11~13cm, 1500cm/s일 때 13~14cm 이상이었다. 2) 예망장력은 예망속도 6.7cm/s에서 105$\pm$5kg으로 매우 작았다. 3) 단위소해면적당 평균어획량은 0.42kg/m 상(2)으로 재래식 형망에 비해 1.2~1.6배로 많았다. 4) 분사식 항망시험 어구는 조개를 파손시키지 않아 어획물에 파손패가 거의 없었다. 5) 분사류에 의한 어장의 탁도 변화량은 수심, 유속, 저질등에 따라 다소 다르나, 표층에서는 수심 5.2m이상이면 변화량을 볼 수 없고, 해저면상 3m의 저층에서는 어구의 후방 1m에서 9~11ppm으로 최대치를 보였으나, 점차 감소되어 9m 후방 이후에서는 변화량이 거의 없었다.

  • PDF

관형 세라믹 정밀여과와 광촉매 첨가 PES 구의 혼성 수처리: 물 역세척 시 유기물 및 흡착, 광산화의 영향 (Hybrid Water Treatment of Tubular Ceramic MF and Photocatalyst Loaded Polyethersulfone Beads: Effect of Organic Matters, Adsorption and Photo-oxidation at Water Back-flushing)

  • 박성우;박진용
    • 멤브레인
    • /
    • 제23권2호
    • /
    • pp.159-169
    • /
    • 2013
  • 고도정수처리를 위한 관형 세라믹 정밀여과와 이산화티타늄($TiO_2$) 광촉매 첨가 PES (polyethersulfone) 구의 혼성공정에서 주기적 물 역세척 시 유기물질의 영향 및 정밀여과(MF), PES 구 흡착, 광산화의 역할을 막오염에 의한 저항($R_f$) 및 투과선속(J), 총여과부피($V_T$) 측면에서 기존의 질소 역세척 결과와 비교하였다. 휴믹산 농도가 증가함에 따라 급격한 막오염으로 $R_f$는 증가하고 J는 감소하여, $V_T$는 휴믹산 농도 2 mg/L에서 가장 높았다. 탁도 처리효율은 물과 질소 역세척 모두 휴믹산 농도와 상관없이 비슷하였다. 유기물질 처리효율은 물 역세척 경우 최대 휴믹산 10 mg/L에서 최소 71.4%이었으나, 질소 역세척에서는 거의 일정하였다. 물과 질소 역세척 모두 MF 및 PES 구, 자외선의 혼성공정(MF + $TiO_2$ + UV)에서 $R_f$가 최소이고, J와 $V_T$는 최대였다. 탁도 및 유기물질의 처리효율도 물과 질소 역세척에 상관없이 MF + $TiO_2$ +UV에서 최대였고, 공정이 MF로 단순화 될수록 처리효율도 점차 감소하였다. 하지만 물 역세척에서는 광산화 보다 흡착이, 질소 역세척에서는 흡착 보다 광산화가 더 주요한 역할을 하였다.

Correlation-based Feature Selection 기법과 Random Forest 알고리즘을 이용한 한강유역 지류의 TDI 예측 연구 (A Study on Predicting TDI(Trophic Diatom Index) in tributaries of Han river basin using Correlation-based Feature Selection technique and Random Forest algorithm)

  • 김민규;윤춘경;이한필;황순진;이상우
    • 한국물환경학회지
    • /
    • 제35권5호
    • /
    • pp.432-438
    • /
    • 2019
  • The purpose of this study is to predict Trophic Diatom Index (TDI) in tributaries of the Han River watershed using the random forest algorithm. The one year (2017) and supplied aquatic ecology health data were used. The data includes water quality(BOD, T-N, $NH_3-N$, T-P, $PO_4-P$, water temperature, DO, pH, conductivity, turbidity), hydraulic factors(water width, average water depth, average velocity of water), and TDI score. Seven factors including water temperature, BOD, T-N, $NH_3-N$, T-P, $PO_4-P$, and average water depth are selected by the Correlation Feature Selection. A TDI prediction model was generated by random forest using the seven factors. To evaluate this model, 2017 data set was used first. As a result of the evaluation, $R^2$, % Difference, NSE(Nash-Sutcliffe Efficiency), RMSE(Root Mean Square Error) and accuracy rate show that this model is compatible with predicting TDI. To be more concrete, $R^2$ is 0.93, % Difference is -0.37, NSE is 0.89, RMSE is 8.22 and accuracy rate is 70.4%. Also, additional evaluation using data set more than 17 times the measured point was performed. The results were similar when the 2017 data set were used. The Wilcoxon Signed Ranks Test shows there was no statistically significant difference between actual and predicted data for the 2017 data set. These results can specify the elements which probably affect aquatic ecology health. Also, these will provide direction relative to water quality management for a watershed that must be continuously preserved.

강원도 횡성지역의 지하수 수질 모니터링 및 인체 위해성 평가 (Water Quality Monitoring and Risk Assessment for Groundwater at Hoengseong, Gangwon-do Province)

  • 강승혜;김기태
    • 한국환경보건학회지
    • /
    • 제47권4호
    • /
    • pp.356-365
    • /
    • 2021
  • Background: Concerns have been raised regarding the criteria of groundwater, in particular in Gwangwon-do Province where many residents drink groundwater due to the poor supply of tap water and a high nonconformity rate with water quality criteria nationwide. Objectives: Water quality monitoring and risk assessment were conducted for groundwater in Hoengseong, Gangwon-do Province. Methods: A total of 46 items required for meeting drinking water criteria were analyzed from 258 samples collected from March 2017 through August 2018 (152 sites in 2017 and 106 sites in 2018). Risk assessment was conducted for two non-carcinogens (F- and NO3-N), and one carcinogen (i.e., arsenic) based on their high nonconformity to water quality criteria. Results: Water quality analysis revealed that the total proportion of nonconformities was determined to be 27.9%. The nonconformity rate for each content item is as follows: total colony counts (1.6%), total coliform (6.2%), Escherichia coli (1.2%), F- (8.1%), arsenic (4.7%), NO3-N (8.1%), pH (1.2%), manganese (0.4%), and turbidity (5.8%). Risk assessment indicated that fluoride induced a hazard quotient greater than 1 with the 95% UCL (Upper Confidence Limit) concentration of the total 258 sites and average, median, and 95% UCL concentrations of nonconformity sites. For NO3-N, there was no human health risk. For arsenic, the excess cancer risk exceeded the acceptable cancer risk of 1×10-6 with the average and 95% UCL concentrations of total 258 sites and average, median, and 95% UCL concentrations of nonconformity sites. Conclusions: This study suggests that it is necessary to expand water quality monitoring of groundwater and conduct a more detailed risk assessment in order to establish a health care plan for the residents of Hoengseong, Gangwon-do Province.

필터의 개발을 통한 해수 육상수조식 양식장의 환경개선에 관한 연구 III. 스크린필터 및 자외선 등의 운행에 따른 사육수의 정화효과 (The Development of Filter for Environmental Improvement in Land Based Seawater Fish Farm III. Purification Efficiency of Rearing Seawater by Screen Filter and Ultraviolet)

  • 강주찬;박수일;김성근
    • 한국수산과학회지
    • /
    • 제32권4호
    • /
    • pp.501-506
    • /
    • 1999
  • 육상수조식 양식장의 사육환경을 개선하기 위하여 청소를 하지 않은 상태에서 5개월 동안 유입수에 필터 (망목, 60$\mu$m) 및 자외선등 (조사량, 0.5 $mWS/cm^2$)을 설치$\cdot$운행하면서 수온, 염분, DO, 영양염류 ($NO_3-N,\;NO_2-N,\;NH_4-\;PO_4-P$), 부유물질, 탁도, 세균수 및 비브리오균수의 변화를 검토하였다. 본 시스템의 설치 운행에 따라 5개월 후의 사육수의 수온, 염분, pH, DO, 세균수 및 비비리오균수의 정화효과는 관찰되지 않았다. 그러나, 사육수의 부유물질 및 탁도는 필터를 설치하지 않은 실험구에서 실험종료시 각각 39.7$\~$41.2mg/$\ell$, 23$\~$24 FAU까지 상승하였으나, 필터를 설치한 실험구 에서 각각 21.6$\~$22.3mg/$\ell$, 16$\~$17 FAU가 증가하여 5개월 후 필터의 설치$\cdot$운행에 의해 각각 $43.8\~45.6\%$ (평균, $44,7\%$), $29.2\~33.2\%$ (평균, $31,3\%$)가 제거되었다. $NO_3-N,\;NO_2-N,\;NH_4-N$$PO_4-P$는 필터를 설치하지 않은 실험구에서 5개월 후 각각 7.95$\~$8.01, 2.98$\~$3.01, 3.87$\~$3.92, 2.35$\~$2,42$\mu$g-at/$\ell$까지 증가하였으나, 필터를 설치한 실험구에서는 각각 6.21$\~$6.30, 2.23$\~$2.30, 3.18$\~$3.23, 1.87$\~$1,96 $\mu$g-at/$\iota$까지 증가하여 필터의 설치에 의해 각각 $21.3\~21.9\%$ (평균,$21.6\%$), $24.1\~25.2\%$ (평균, $24.7\%$), $17.6\~17.8\%$ (평균, $17.7\%$) 및 $19.0\~20.4\%$ (평균, $19.7\%$)의 제거 효과를 보았다.

  • PDF

Membrane bioreactor(MBR)과 Reverse osmosis(RO) 공정을 이용한 하수처리 (Sewage Treatment using Membrane Bioreactor(MBR) and Reverse Osmosis(RO) Process)

  • 오승욱;정종태;이진우;김종오
    • 한국지반환경공학회 논문집
    • /
    • 제8권6호
    • /
    • pp.21-28
    • /
    • 2007
  • 본 연구는 합성하수 처리에 있어 MBR-RO 공정 적용시 유기물 및 질소, 인 제거에 대하여 수리학적체류시간이 제거효율에 미치는 영향을 실험적으로 검토하였다. MBR 공정에서 탁도는 운전기간(105일)동안 2 NTU 이하로 평균 99% 이상의 제거효율을 보였다 또한 수리학적체류시간 6, 12, 18 그리고 24 hour에 대한 $COD_{Cr}$, T-N, $NH_4{^+}-N$ 그리고 T-P의 평균 제거효율을 살펴보면, $COD_{Cr}$의 평균 제거율은 각각 72.4, 84, 88.6 그리고 92.5%, $NH_4{^+}-N$의 제거효율은 각각 60.2, 85.5, 91.3 그리고 92.2%였다. T-N과 T-P의 제거효율은 수리학적 체류시간을 6시간에서 24시간으로 증가시킴에 따라 각각 53.7과 56.8%에서 82.5와 86.4%로 증가했다. RO 공정에서 색도와 $COD_{Cr}$의 제거효율은 각각 99.9%와 96.8%였다. 또한 RO 유출수에서 T-N, $NH_4{^+}-N$, $NO_3{^-}-N$ 그리고 T-P는 평균 90% 이상 제거되었다.

  • PDF

Water Treatment of High Turbid Source by Tubular Ceramic Microfiltration with Periodic Water-back-flushing System

  • Lee, Hyuk-Chan;Park, Jin-Yong
    • Korean Membrane Journal
    • /
    • 제9권1호
    • /
    • pp.12-17
    • /
    • 2007
  • We performed periodic water-back-flushing using permeate water to minimize membrane fouling to enhance permeate flux in tubular ceramic microfiltration system for water treatment of high turbid source. The filtration time (FT) = 2 min with periodic 6 sec water-back-flushing showed the highest value of dimensionless permeate flux ($J/J_o$), and the lowest value of resistance of membrane fouling ($R_f$), and we acquired the highest total permeate volume $(V_T)\;=\;6.805L$. Also in the result of BT effect at fixed FT = 10 min and BT (back-flushing time) = 20 sec showed the lowest value of $R_f$ and the highest value of $J/J_o$, and we could obtain the highest $V_T\;=\;6.660\;L$. Consequently, FT = 2 min and BT = 6 sec could be the optimal condition in water treatment of high turbid source above 10 NTU. However, FT = 10 min and BT = 20 sec was superior to reduce operating costs because of lower back-flushing frequency. Then the average quality of water treated by our tubular ceramic MF system was turbidity of 0.07 NTU, $COD_{Mn}$ of 1.86 mg/L and $NH_3-N$ of 0.007 mg/L.