• Title/Summary/Keyword: Average time to signal

Search Result 522, Processing Time 0.029 seconds

A Camera Based Traffic Signal Generating Algorithm for Safety Entrance of the Vehicle into the Joining Road (차량의 안전한 합류도로 진입을 위한 단일 카메라 기반 교통신호 발생 알고리즘)

  • Jeong Jun-Ik;Rho Do-Hwan
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.4 s.310
    • /
    • pp.66-73
    • /
    • 2006
  • Safety is the most important for all traffic management and control technology. This paper focuses on developing a flexible, reliable and real-time processing algorithm which is able to generate signal for the entering vehicle at the joining road through a camera and image processing technique. The images obtained from the camera located beside and upon the road can be used for traffic surveillance, the vehicle's travel speed measurement, predicted arriving time in joining area between main road and joining road. And the proposed algorithm displays the confluence safety signal with red, blue and yellow color sign. The three methods are used to detect the vehicle which is driving in setted detecting area. The first method is the gray scale normalized correlation algorithm, and the second is the edge magnitude ratio changing algorithm, and the third is the average intensity changing algorithm The real-time prototype confluence safety signal generation algorithm is implemented on stored digital image sequences of real traffic state and a program with good experimental results.

Unusual Waveform Detection Algorithm in Arrhythmia ECG Signal (부정맥 심전도 신호에서 특이 파형 검출)

  • Park, Kil-Houm;Kim, Jin-Sub;Ryu, Chunha;Choi, Byung-Jae;Kim, Jungjoon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.4
    • /
    • pp.292-297
    • /
    • 2013
  • In this paper, unusual waveform detection algorithm based on Refractory Period in arrhythmia ECG signal is proposed. Most of arrhythmia ECG signals consist of unusual waveforms with average 10% rate. Thus tremendous benefit can be obtained in terms of time and cost by providing unusual waveform samples reduced more than 90% to medical staffs who have to monitor and analyze for a long time. The proposed algorithm detects the R-peak using the features of R wave and variable refractory period. For the detected R-peak, unusual waveforms are found using means and standard deviation of electric potential and kurtosis of the R-peaks which are not included in unusual waveform. The proposed algorithm was applied to all records of the MIT-BIH arrhythmia database and showed more than average 90% of compression ratio.

A Spatial Average Method Using 2nd Order Sampling in Ultrasonic Doppler System (초음파 도플러 시스템에서 2차 샘플링을 이용한 공간축상의 평균 방법)

  • 백광렬
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.279-288
    • /
    • 1995
  • Ultrasonic Doppler systems for the purpose of estimating blood flow velocity, blood flow volume, and flow imaging are commonly used due to advantages of non-invasive and real time observation. Specially, the technical developments of color flow mapping (2-D Doppler) systems have made a relatively rapid progress. However, the 2-D Doppler systems have several problems, such as the range ambiguity, low signal to noise ratio, and slow frame rate. The slow frame rate problem is resolved by using the spatial average which is a method to acquire more data samples for mean frequency estimation. In this paper, spatial average method using the 2nd order sampling instead of quadrature sampling is proposed. The experimental results show that the proposed methods have good performance and easy application to the color flow mapping system.

  • PDF

Auto Dispatch Device of Parturition Beginning Signal by Temperature and a Load Sensor at Ubiquitous Circumstance in Pig Industry (양돈산업에 있어서 유비쿼터스 환경에서 온도 및 하중 센서에 의한 자동 분만 알림 시스템 개발)

  • Lee, Jang-Hee;Baek, Soon-Hwa;Yon, Seung-Ho
    • Reproductive and Developmental Biology
    • /
    • v.33 no.3
    • /
    • pp.139-146
    • /
    • 2009
  • This study tried to develop the system (device) that automatically notify a manager of condition just before and after farrowing to extend ubiquitous-based technology and to increase efficiency of delivery care and productivity by reducing human labor and time on standby when farrowing management is done in the difficult and hard working environment of farrowing such as night or holidays in field sand especially in pig industry. In this test, selected 10 gilts were executed timed artificial insemination and were set up each temperature sensor and load sensor to them 3 days before the estimated farrowing day and were observed the farrowing situation. This study was embodied the NESPOT-based (KT Corporation) monitoring system, the system to transmit data in real time by utilization of wireless LAN and the sensor module to apply the ubiquitous environment to them. And this study was observed the situation to automatically notify situations of 10 gilts that first bore just before and after farrowing. The result obtained the farrowing situations of them in real time by setup of the NESPOT-based monitoring system to check farrowing situation directly is as follow. The average time of the automatic notice about situation just before farrowing by the temperature sensor was 27.5 minutes before the beginning of farrowing (the expulsion time of a piglet). 6 of 8 pregnant gilts that first bore automatically were notified situations just before farrowing and the temperature sensors inserted into 2 ones before farrowing were omitted. (The automatic notice rate 75%) The average time of the automatic notice of situation just after farrowing by the load sensor was taken 46.5 minutes after the beginning of farrowing (the expulsion time of a first piglet). The average gestation period of 8 ones that first bore and were tested by the automatic notice of farrowing situation was 115.6 days. This result found that the automatic farrowing notice system by the temperature sensor is more efficient than the load sensor as the automatic farrowing alarm device and sanitary treatment and improvement of the omission rate were required.

Value of Echo-Planar Imaging and MRI Dynamic Study in Differentiation Liver Diseases (간 질환 감별에 있이 MR영상의 역동적 검사와 EPI의 유용성)

  • Park, Byung-Rae
    • Journal of radiological science and technology
    • /
    • v.20 no.2
    • /
    • pp.73-78
    • /
    • 1997
  • The goal of this paper is that we know the usefulness of echo-planar imaging(EPI) for discriminate between hepatocellular carcinoma(HCC) and hemangioma. We get a time signal intensity curve for liver diseases from the dynamic contrast enhancement images and compared and analyze both the contrast ratio(CR) and the contrast to noise ratio(CNR) using echo planar imaging. The obtained results are follows : 1. Hepatocellular carcinoma was shown the best contrast after about 20 seconds when Is the earlist time in the main artery, and then reduced. The center where is disease was shown the characteristic that the best contrast is appeared after about 35-45 seconds and then slowly reduced. Liver parenchyma was shown the best contrast and reduced after 60 seconds. 2. The peripheral nodular of hemangioma was shown the better contrast soon. On the other hend, the contrast of center where is disease started to increase after 60 seconds and was equal to that of liver parenchyma. Increasing of the contrast continued after. 3. Turbo SE technic was used, the average of CR for hepatocellular carcinoma was $36.7{\pm}1.2$ and the average of CNR was $2.4{\pm}3.2$, while the average of CNR for hemangioma was $54.9{\pm}1.0$ and the average of CNR was $9.7{\pm}1.3$. 4. EPI technic was used, the average of CR for hepatocellular carcinoma was $47.8{\pm}1.2$ and the average of CNR was $3.4{\pm}2.1$, while the average of CNR for hemangioma was $75.7{\pm}2.2$ and the average of CNR was $9.5{\pm}1.1$. According to above we can find that hemangioma is more bright than hepatocellular carcinoma and the difference of brightness between hepatocellular carcinoma and hemangioma is useful sequence.

  • PDF

Evaluation of Clinical Application Model of Optimized Parameter through Analysis of Stability of Radiation Output and Image Quality when Exposure Time Change of Digital Radiography (DR) (디지털 방사선 시스템(DR)의 조사시간 변화 시 방사선 출력과 영상 화질의 안정성 분석을 통한 최적화된 파라미터의 임상 적용 모델 평가)

  • Hwang, Jun-Ho;Choi, Ji-An;Kim, Hyun-Soo;Lee, Kyung-Bae
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.139-148
    • /
    • 2020
  • The purpose of this study is to propose a method to optimize the performance of Digital Radiography (DR) by analyzing the effect of exposure time change on the stability of radiation output and image quality. The experimental method was used to change the exposure time to 50 msec, 100 msec, 200 msec, and 400 msec so that the Percentage Average Error (PAE), Time-to-Radiation Dose Curve, Signal to Noise Ratio (SNR), Contrast to Noise Ratio (CNR) and theses analysis were performed to evaluate the normal operation of parameters, radiation output and image quality. As a result, all the parameters used in the experiment showed the Percentage Average Error in the normal range, and the shorter the exposure time, the stability of radiation output and image quality decrease. In conclusion, it was found that the performance of Digital Radiography can be optimized when stable radiation output and image quality are applied by applying 100 msec ~ 200 msec exposure time.

Symbol interferometry and companding transform for PAPR reduction of OTFS signal

  • Aare Gopal;Desireddy Krishna Reddy;Srinivasarao Chintagunta
    • ETRI Journal
    • /
    • v.46 no.4
    • /
    • pp.595-603
    • /
    • 2024
  • This paper presents methods for reducing the peak-to-average power ratio (PAPR) of the orthogonal time frequency space (OTFS) signal. These methods mainly consist of two operations: symbol interferometry (SI) and either 𝜇-law or A-law companding. SI spreads the data of one OTFS symbol onto all symbols and is implemented using a simple inverse fast Fourier transform operation on each OTFS symbol. During the second operation, the PAPR of the OTFS signal is significantly reduced. For our performance analysis, the complementary cumulative distribution function, probability density function, and bit error rate are illustrated through simulations performed in MATLAB. The performance is also analyzed using a solid-state power amplifier at the transmitter and compared with OTFS, 𝜇-law-based OTFS, and SI OTFS systems. The results indicate that the proposed OTFS system achieves a low PAPR.

Performance Analysis and Evaluation of Deployment in Small Cell Networks

  • Zheng, Kan;Li, Yue;Zhang, Yingkai;Jiang, Zheng;Long, Hang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.3
    • /
    • pp.886-900
    • /
    • 2015
  • Small cells are deployed in Heterogeneous Networks (HetNet) to improve overall performance. These access points can provide high-rate mobile services at hotspots to users. In a Small Cell Network (SCN), the good deployment of small cells can guarantee the performance of users on the basis of average and cell edge spectrum efficiency. In this paper, the performance of small cell deployment is analyzed by using system-level simulations. The positions of small cells can be adjusted according to the deployment radius and angle. Moreover, different Inter-Cell Interference Coordination (ICIC) techniques are also studied, which can be implemented either in time domain or in frequency domain. The network performances are evaluated under different ICIC techniques when the locations of Small evolved Nodes (SeNBs) vary. Simulation results show that the average throughput and cell edge throughput can be greatly improved when small cells are properly deployed with the certain deployment radius and angle. Meanwhile, how to optimally configure the parameters to achieve the potential of the deployment is discussed when applying different ICIC techniques.

Principal Component Analysis of GPS Height Time Series from 14 Permanent GPS Stations Operated by National Geographic Information Institute (주성분분석을 통한 국토지리정보원 14개 GPS 상시관측소 수직좌표 시계열 분석)

  • Kim, Kyeong-Hui;Park, Kwan-Dong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.3
    • /
    • pp.361-367
    • /
    • 2010
  • We produced continuous vertical time series of 14 permanent GPS stations operated by National Geographic Information Institute by processing about five years of data. Then we computed the height velocities by using a linear regression fitting of those time series, and did principal component analysis to understand the overall characteristics of the series. The prominent signal obtained as the first mode of PCA results showed an average of 4.2 mm/yr vertical velocity. The values of the first mode eigenvectors were consistent at all sites. Thus, we concluded that all the 14 stations are uplifting nearly at the same velocity for the test period. Then changes of precision before and after removing the first mode signal from the 14 height time series were analyzed. As a result, the precision improved 34.8% on average.

Low Complexity Discrete Hartley Transform Precoded OFDM System over Frequency-Selective Fading Channel

  • Ouyang, Xing;Jin, Jiyu;Jin, Guiyue;Li, Peng
    • ETRI Journal
    • /
    • v.37 no.1
    • /
    • pp.32-42
    • /
    • 2015
  • Orthogonal frequency-division multiplexing (OFDM) suffers from spectral nulls of frequency-selective fading channels. Linear precoded (LP-) OFDM is an effective method that guarantees symbol detectability by spreading the frequency-domain symbols over the whole spectrum. This paper proposes a computationally efficient and low-cost implementation for discrete Hartley transform (DHT) precoded OFDM systems. Compared to conventional DHT-OFDM systems, at the transmitter, both the DHT and the inverse discrete Fourier transform are replaced by a one-level butterfly structure that involves only one addition per symbol to generate the time-domain DHT-OFDM signal. At the receiver, only the DHT is required to recover the distorted signal with a single-tap equalizer in contrast to both the DHT and the DFT in the conventional DHT-OFDM. Theoretical analysis of DHT-OFDM with linear equalizers is presented and confirmed by numerical simulation. It is shown that the proposed DHT-OFDM system achieves similar performance when compared to other LP-OFDMs but exhibits a lower implementation complexity and peak-to-average power ratio.