• Title/Summary/Keyword: Average temperature

Search Result 5,142, Processing Time 0.032 seconds

Garlic yields estimation using climate data (기상자료를 이용한 마늘 생산량 추정)

  • Choi, Sungchun;Baek, Jangsun
    • Journal of the Korean Data and Information Science Society
    • /
    • v.27 no.4
    • /
    • pp.969-977
    • /
    • 2016
  • Climate change affects the growth of crops which were planted especially in fields, and it becomes more important to use climate data to predict the yields of the major vagetables. The variation of the crop products caused by climate change is one of the significant factors for the discrepancy of the demand and supply, and leads to the price instability. In this paper, using a panel regression model, we predicted the garlic yields with the weather conditions of different regions. More specifically we used the panel data of the several climate variables for 15 main garlic production areas from 2006 to 2015. Seven variables (average temperature, average maximum temperature, average minimum temperature, average surface temperature, cumulative precipitation, average relative humidity, cumulative duration time of sunshine) for each month were considered, and most significant 7 variables were selected from the total 84 variables by the stepwise regression. The random effects model was chosen by the Hausman test. The average maximum temperature (January), the cumulative precipitation (March, October), the cumulative duration time of sunshine (April, October) were chosen among the variables as the significant climate variables of the model

Monitoring the phenology of Forsythia velutina, an endemic plant of Korea

  • Sung, Jung-Won;Kim, Geun-Ho;Lee, Kyeong-Cheol;Shim, Yun-Jin;Kang, Shin-Gu
    • Journal of People, Plants, and Environment
    • /
    • v.24 no.4
    • /
    • pp.355-363
    • /
    • 2021
  • Background and objective: This study was conducted on Forsythia velutina, a special plant, in Gyeongsangnam-do Arboretum under the Gyeongsangnam-do Forest Environment Research Institute, which is located in the southern part of Korea. Methods: The research aimed to analyze the flowering characteristics of the plant by calculating the optimal temperature and humidity according to the flowering time and flowering period for 8 years from 2010 to 2017 in order to provide basic data for bioclimate studies of endemic plants. Results: It was observed that the Forsythia velutina showed a life cycle from mid-March and to mid-November. Average growth period was 243 (± 6.5) days. In testing the reliability of a single variable according to the meteorological factors, the Cronbach's Alpha was 0.701, which indicates that the findings were relatively reliable. The average date of flowering was March 16 (SD = 5.8) and the average date on which blossoms fall was March 29 (SD = 5.2). A substantial difference in flowering period was observed from year to year 11 to 23 days, with an average of 16 days (± 4.7). The temperature and humidity in February to March, which affect the flowering, were 2.9-5.5℃, and 66.5-73.0%, respectively, and showed differences every year. Conclusion: The correlation between flowering time and meteorological factors was positive, and the highest daily temperature and average daily temperature had the highest significance. When establishing basic data on plant species for the conservation of endemic plants, the changes in life cycle events and weather conditions are identified. It is believed that it will be helpful in establishing a conservation strategy for the plant species in the future.

Analysis of Abnormal Sea Surface Temperature in the Coastal Waters of the Yellow Sea Using Satellite Data for the Winter Season of 2004 (인공위성자료를 이용한 2004년 겨울철 황해 연안 해역 이상 수온 해석)

  • Moon, Jeong-Eon;Yang, Chan-Su
    • Korean Journal of Remote Sensing
    • /
    • v.25 no.1
    • /
    • pp.1-10
    • /
    • 2009
  • We studied on the relationship between oceanic variation in the offshore and abnormal sea surface temperature rise in the coastal area of the Yellow Sea using a variety of satellite and in-situ data during winter 2004. In results of the satellite data, the average value of sea surface temperature in the Yellow Sea for 2003 was $10^{\circ}C$, and the average value of sea surface temperature for 2004 was $13^{\circ}C$. It was higher than those of the last year about $3^{\circ}C$. In results of the in-situ data, the average value of surface layer temperature in the Yellow Sea for 2003 was $9.85^{\circ}C$, and the average value of surface layer temperature for 2004 was $12.17^{\circ}C$. In the same satellite data, it was higher than those of the last year about $3^{\circ}C$. In results of the T-S diagram, we divided definitely into water mass of the Yellow Sea and the East China Sea in 2003. But we didn't divide definitely into water mass of the Yellow Sea and the East China Sea in 2004. The average values of air temperature and wind speed for 2003 were $5.23^{\circ}C$ and 4.81 m/s, respectively. And, the average values of air temperature and wind speed for 2004 were $5.61^{\circ}C$ and 4.52 m/s, respectively. So, These were similar. But the wind directions for 2003 were superior northwestern wind, and the wind directions for 2004 were various northern wind. The wind directions were different from each other. Therefore, the abnormal sea surface temperature rise in the coastal area of the Yellow Sea during winter 2004 were better related to oceanic variation in the offshore than influences of atmosphere. In the future, We will do in-depth study for these.

Underground Heat Transfer Characteristics of the Underground Heating System for Soil Sterilization in Greenhouse (온실 내 토양소독을 위한 지중난방시스템의 지중 열전달 특성)

  • Park, Kyung-Kyoo;Ha, Yu-Shin;Hong, Dong-Hyuck;Jang, Seung-Ho;Kim, Jin-Hyun
    • Journal of Biosystems Engineering
    • /
    • v.35 no.2
    • /
    • pp.108-115
    • /
    • 2010
  • This study was conducted to estimate the optimum temperature and required time for soil sterilization when heated water was circulated through underground heating pipes in the greenhouse which solar heat was influenced to the temperature of soil during the summer day. Two different types of heating pipes were used for the experiment. One was a polyethylene pipe(XL) and the other was a corrugated ring shaped stainless steel pipe(STS). The results of the studies were summarized as follows; By measuring the thermal characteristics of the XL and STS, it was examined that the average temperature differences of the inlet and outlet were $8.5^{\circ}C$ and $13.3^{\circ}C$, the average flowrates were 15.3 L/min and 5.6 L/min, and the average radiation powers were 9.1 kW and 4.1 kW, respectively. As results of the regression analysis of underground temperatures, when average soil temperature was$35^{\circ}C$, an average water temperature was $80^{\circ}C$, and XL was used, it was estimated that the possible heat transfer distance, the required time for heat transfer and heat flux to reach the underground temperature of $60^{\circ}C$ were 300 mm, 230 hours, and $7.57kW/m^2$, respectively.

Hot and average fuel sub-channel thermal hydraulic study in a generation III+ IPWR based on neutronic simulation

  • Gholamalishahi, Ramin;Vanaie, Hamidreza;Heidari, Ebrahim;Gheisari, Rouhollah
    • Nuclear Engineering and Technology
    • /
    • v.53 no.6
    • /
    • pp.1769-1785
    • /
    • 2021
  • The Integral Pressurized Water Reactors (IPWRs) as the innovative advanced and generation-III + reactors are under study and developments in a lot of countries. This paper is aimed at the thermal hydraulic study of the hot and average fuel sub-channel in a Generation III + IPWR by loose external coupling to the neutronic simulation. The power produced in fuel pins is calculated by the neutronic simulation via MCNPX2.6 then fuel and coolant temperature changes along fuel sub-channels evaluated by computational fluid dynamic thermal hydraulic calculation through an iterative coupling. The relative power densities along the fuel pin in hot and average fuel sub-channel are calculated in sixteen equal divisions. The highest centerline temperature of the hottest and the average fuel pin are calculated as 633 K (359.85 ℃) and 596 K (322.85 ℃), respectively. The coolant enters the sub-channel with a temperature of 557.15 K (284 ℃) and leaves the hot sub-channel and the average sub-channel with a temperature of 596 K (322.85 ℃) and 579 K (305.85 ℃), respectively. It is shown that the spacer grids result in the enhancement of turbulence kinetic energy, convection heat transfer coefficient along the fuel sub-channels so that there is an increase in heat transfer coefficient about 40%. The local fuel pin temperature reduction in the place and downstream the space grids due to heat transfer coefficient enhancement is depicted via a graph through six iterations of neutronic and thermal hydraulic coupling calculations. Working in a low fuel temperature and keeping a significant gap below the melting point of fuel, make the IPWR as a safe type of generation -III + nuclear reactor.

The correlation between average temperature & precipitation and Pattern Identification of the patients with stroke (중풍환자의 변증(辨證)과 기온 및 강수여부와의 상관성에 관한 연구)

  • Ma, Mi-Jin;Kim, Bo-Ram;Kim, Mi-Kyung;Choi, Dong-Jun;Han, Chang-Ho;Jung, Seung-Hyun;Shin, Gil-Jo;Lee, Won-Chul
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.9 no.1
    • /
    • pp.8-13
    • /
    • 2008
  • Objectives : This study was to investigated the correlation between average temperature & precipitation and pattern identification of the patients with stroke. Methods : 115 stroke patients within 30days of onset were registered during the study period. Pattern identification of stroke was classified into Fire and heat, Turbid phlegm and others. We took the mean of average temperature according to pattern identification and analyzed pattern identification into two groups according to climatological normal of average temperature in Seoul. We also analyzed pattern identification into two groups according to existence of precipitation. Results : Heat and fire, and other type of pattern identification had high frequency when average temperature was higher than 12.2℃. And there was no correlation between precipitation and pattern identification of stroke.

  • PDF

Secular Variations of Surface Water Temperature in Youngil Bay (영일만 해역 표면수온의 누년변화)

  • 양삼승
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.21 no.1
    • /
    • pp.62-66
    • /
    • 1985
  • The periodic variations of the surface water temperature and the relationships between the surface water and air temperature are found in Youngil bay as follows: It is considered that the average surface water temperature is the lowest in February and the highest in August in the Youngil bay (Pohang bay and Janggi cape) from January, 1962 to December, 1981. It is only in October and November that the average surface water temperature was higher in pohang bay than in the Janggi cape from January, 1962 to December, 1981. Since the periodic secular variation in the vincity of Youngil bay and the variation of the Tsushima Current seem to have similar tendencies, we may conclude that the changes of the surface water temperature in Youngil bay are primarily influenced by the Taushima Current. The average temperature of surface water is 14.5$^{\circ}C$ in Pohang bay and 15.$0^{\circ}C$ in Janggi cape in the secular variation.

  • PDF

Measurement of the Moderator Temperature Coefficient of Reactivity for Pressurized Water Reactors

  • Yu, Sung-Sik;Kim, Se-Chang;Na, Young-Whan;Kim, H. S.;J. Y. Doo;Kim, D. K.;S. W. Long
    • Nuclear Engineering and Technology
    • /
    • v.29 no.6
    • /
    • pp.488-499
    • /
    • 1997
  • The measurements of the moderator temperature coefficient (MTC) are performed to demonstrate that the calculational model produces results that are consistent with the measurements. Since negative MTC is also a technical specification value that may limit the cycle length, it is important to measure it as accurately as possible. In this report, preferred choice of test method depending on the time in cycle, best power indication and temperature definition in MTC calculation were determined based on the MTC test results taken during initial startup testing and at 2/3 cycle burnup in the Yonggwang nuclear power plant. The results show that the ratio and rodded methods provided good agreement with the predictions during initial startup testing. However, near end-of-cycle the depletion method gives better results, and so is suggested to be used in the MTC measurements at 2/3 cycle burnup. The use of primary Delta T power as a power indicator in the MTC calculations is highly advisable since it responds with good consistent results very quickly to changes unlike secondary calorimetric power. For the appropriate temperature definitions used in the MTC calculations, it is considered that the arithmetic average temperature measured simply by inlet and outlet thermocouples is preferred. Although volumetric average temperature provides better results, the improvement is not sufficient to compensate for the simplicity of calculations by arithmetic average temperature.

  • PDF

A Verification Study on the Temperature reduction Effect of Water Mist Injection

  • Kim, Jeong-Ho;Lee, Myung-Hun;Yoon, Yong-Han
    • KIEAE Journal
    • /
    • v.15 no.3
    • /
    • pp.5-14
    • /
    • 2015
  • Purpose: Recently, according to climate changes, human health is exposed to danger over the world and they influence all fields of human society. Due to these climate changes, humans can be exposed to more frequent and extreme scorching heat and cold wave than the present. As precautions against these urban higher temperature and dryness, diverse methods are being sought. Among them, as measures to form cold islands, the evaporative cooling effect realistic to social and economic conditions was examined. Method: This study was conducted to analyze effects of temperature reduction and cooling according to injection quantity of minute water particles by using a blast sprayer as one of alternatives of alleviation of urban climate changes in outside space in summer. For this, through temperature difference in accordance with the injection quantity per hour of a day, a time zone representing the value of the highest temperature change was analyzed. Also, by analyzing temperature difference according to the injection quantity per daytime insolation, relation of amounts of insolation and evaporation was investigated. Temperature difference in accordance with distances at the highest temperature with the highest value in temperature changes was analyzed. Result: At the study result, about temperature, as injection quantity increase, temperature reduction was significant statistically at the highest temperature with the most insolation. A factor with the highest influence was judged to be the increase of the injection quantity. According to the injection quantity, it was predicted that $3.1^{\circ}C$ temperature reduction of a daily average in case of 0.16L/min, $3.5^{\circ}C$ temperature reduction of a daily average in case of 0.32L/min, and $4.4^{\circ}C$ temperature reduction of a daily average in case of 0.48L/min.

Evaluation on Early-maturing Korean Japonica Cultivars for High-temperature Tolerance during Grain Filling Stage (국내 육성 조생종 벼 품종들에 대한 등숙기 고온내성 평가)

  • Cho, Seong-Woo;Jeung, Ji-Ung;Kang, Kyung-Ho;Kim, Hyun-Soon;Kim, Bo-Kyeong
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.60 no.2
    • /
    • pp.146-152
    • /
    • 2015
  • Early-maturing Korean Japonica cultivars and Jungmo1024 were used as plant materials to evaluate hightemperature tolerance during grain filling stage. National Institute of Crop Science (NICS) in Korea developed Jungmo1024, a mutant line from Namil (wild type) treated by using sodium azide (SA) as mutagen. To evaluate high-temperature tolerance, all cultivars were exposed to high-temperature (day $31.5{\pm}2.5^{\circ}C$/ night $27.5{\pm}1.3^{\circ}C$) and ordinary temperature (day $27.5{\pm}1.8^{\circ}C$/ night $24.7{\pm}1.6^{\circ}C$) during grain filling stage. In these conditions, we performed compared evaluation of grain shape such as length and width and grain quality by using a 1625 Cervitec grain inspector. High-temperature during grain filling stage caused decrease of grain shape. In grain shape such as length and width, the decrease rate of width (average 6.3%) was higher than the decrease rate of length (average 1.3%). Hence, high-temperature affected width of grain than length of grain. In addition, high-temperature showed a decided difference in rate of head rice between ordinary temperature (average 76.3%) and high-temperature (average 13.3%).As a result, Taebong, Ungwang, Manan, and Jungmo1024 seemed relatively a decent high-temperature tolerance than other cultivars. Especially, Jungmo1024 seemed remarkable rate of head rice (average $34.4{\pm}6.2%$) than other cultivars under high-temperature. It is considered that a genetic trait of Jungmo1024 can be useful to improve breeding for high-temperature tolerance.