• Title/Summary/Keyword: Average image difference

Search Result 433, Processing Time 0.027 seconds

A New Binary Thresholding Method using Bit-plane Information (비트평면 정보를 사용한 새로운 2진 임계화 방법)

  • 김하식;조남형;김윤호;이주신
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.6
    • /
    • pp.1169-1174
    • /
    • 2001
  • A new approach for determining global threshold value of binary image is proposed in this paper. In the proposed algorithm, bit-plane information which involve the shapes of original image is used for dividing image into two parts; object and background. Optimal threshold value are selected based on difference values of average between two regions, which is considered in global binary thresholding. Proposed method is no need to set a initial value, and consequently, it is relatively simple as well as robust. Experimental results showed a good performance in preserving edge not only continuous tone images but also document image.

  • PDF

Clinical Application of Image Guided Surgery : Zeiss SMN System (영상유도 뇌수술 장비의 임상적 적용 : Zeiss SMN System)

  • Lee, Chea Heuck;Lee, Ho Yeon;Whang, Choong Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.1
    • /
    • pp.72-77
    • /
    • 2000
  • The authors describe the experience with the interactive image-guided Zeiss SMN system, which has been applied to 20 patients with various intracranial lesions during one year. Preoperative radiologic evaluation was CT scan in 6 cases, MRI in 14 cases. In all except one case, average fiducial registration errors were less than 2mm. There was no statistical difference in registration error between CT and MR image. This system considered to be relatively stable with respect to soft and hardware. Also it was useful for the designing of the scalp incision and bone flap and assessing the extent of resection in tumors, especially in gliomas. Moreover, it was helpful to evaluate complex surgical anatomy in skull base surgery.

  • PDF

A Study on Self-image and Clothing-Purchasing-Behavior of Adolescence (여고생의 자아 이미지와 의복구매 행동에 관한 연구)

  • 김영신;한명숙
    • The Research Journal of the Costume Culture
    • /
    • v.6 no.1
    • /
    • pp.94-109
    • /
    • 1998
  • The objective of this study is to measure self-image of adolescence, analyze empirically clothing-purchasing-behavior of adolescence and clarify correlation of two variables, self-image and clothing-purchasing-behavior. For this purpose, the techniques involve theoretical studies and researches based on historical obtained from previous related studies and surveys, 431 high school female students who reside in Seoul are asked to answer selected survey questions to examine three aspects, clothing-purchasing-behavior, self-image and demographics. The evaluation of surveyed information is analyzed by statistical techniques to improve the accuracy of data. Statistical methods used are as follows; Descriptive(frequency, mean, percentage), Factor Analysis(varimax rotation), Crosstabs(Chi-square), T-test, One-Way ANOVA< Correlation Analysis, Reliability Analysis and Duncan's Multiple Range Test. The mjor results of this study were as follows: Firstly, there is a discrepancy between real self-image and ideal self-image. Furthermore more significant differences is seen from physical aspects than psychological aspects. Consequently, research proves that the difference derived from their ideal situation and real situation leads to psychological unstableness. In addition, making their real self-image is dependent upon several elements such things as family economic level, pocket money, expenditure on clothing. Therefore, it is critical to combine all factors in order to decide how much to spend for children's clothing and pocket money in parents point of view. Secondly, research shows that shows hat there is correlated relationship between average expenditure on clothing and presence of mother's job. Average expenditure on clothing is, generally, influenced by vogue which is tend to be changed seasonally. It, also, shows that there is positive linear regression between expenditure on clothe and sensitivity for vogue. That is to say, dependent variable, expenditure on clothing, is varied as independent variable, sensitivity for vogue, changes. Female high school students are likely to give much value on brand. Moreover people who are spending more money on clothes have higher tendencies in prompt purchases than who are not. Thirdly, the analysis of clothing-purchasing-behavior and self-image shows that the difference between real self-image and ideal self-image draws the main reason of dissatisfaction after purchase of clothes. As a consequence, their unfilled needs lead them to keep making another purchase to satisfy themselves. Therefore, it is strongly recommended that parents' advices and directions on their children's money spending on clothes are imperative to establish well-behaved purchasing patterns.

  • PDF

The study of utility about magnetic resonance elastography for measurements of liver stiffness : the comparisons of ADC value & T2 weighted image (간 경화도 측정을 위한 3.0T 자기공명 탄성계수 영상의 유용성에 대한 고찰 : 확산계수 영상 및 T2 강조 영상과의 비교)

  • Kim, Sang-Woo;Kang, Chung-Hwan;Kim, Sung-Ho;Kim, Kyung-Soo;Kim, Soon-Bae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.1
    • /
    • pp.21-29
    • /
    • 2012
  • The purpose of this study is to evaluate the mutual relations by measuring SNR from T2 weighted image and ADC values on the basis of the stiffness values from liver tissues. This study was conducted that total 37 people(23 of males and 11 of females) were taken the liver MRI examination and average age was $54.5{\pm}12.7$ years old. The equipment was MAGNETOM Skyra 3.0T (SIEMENS, Erlangen, Germany) and 32 channel body-array coil. The examination were conducted with HASTE T2 weighted image by axial plane, Spin-echo EPI (echo planner image) DWI (b-value = 800) and Magnetic resonance elastography. The ROIs (region of interest: 200-300 $mm^2$) were established on the basis of the first axial stiffness image corresponded 95% confidence interval from axial stiffness image and then were measured values. After drawing the grid lines, signals were measured SNR from T2 weighted image and ADC values on the same locations that were analysed other 3 planes respectively. The results were showed correlation (0.057) that were increased to SNR from T2 weighted image by increasing stiffness value that no significant difference statistically p = 0.003. Other results were showed correlations (-0.301) that were decreased to ADC values by increasing stiffness values that no significant difference statistically p = 0.088. In the 3.0T equipment, the results may be error in much the same fashion as the 1.5T from ADC values by evaluation of fibrosis stage. However, Magnetic resonance elastography would be useful method that is used to diagnose exactly liver fibrosis stages in the 3.0T.

  • PDF

Steganographic Method on Spatial Domain Using Modular Characteristic (모듈러 특성을 이용한 공간영역 기반의 심층암호)

  • Park Young-Ran;Shin Sang-Uk
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.16 no.2
    • /
    • pp.113-119
    • /
    • 2006
  • Image steganography is a secret communication method used to transmit secret messages that have been embedded into an image. To accommodate a secret message in a digital image, the original cover image is modified by the embedding algorithm. As a result, a stego image is obtained. The sender hides the secret message in a cover image that has no meaning, and then transmits the stego image to the receiver. In this paper, we propose a steganographic method based on spatial domain to embed a secret message using a difference value of two consecutive pixels and a secret quantization range. Especially, we use the modular operation for increasing of insertion information. Through experiments, we have shown that the proposed method has much mon payload capacity, average 60 percent, than some existing methods by using modular operation.

A Study on Applicable External Color Design of High-storied Apartment House Considering Street Components (주변가로 구성요소를 고려한 고층집합주택의 적용 가능한 외관색채에 관한 연구)

  • Lee Cheong-Woong;Park Sung-Jin;Kim Mu-Oh;Park Hang-Ja
    • Journal of the Korean housing association
    • /
    • v.17 no.3
    • /
    • pp.123-131
    • /
    • 2006
  • This study examined types and color conditions of street views through relationship of high-storied apartment house to street components which has great visual influence on urban street view and requires harmony with street environment as background factor and conducted positive experiment with high-storied apartment houses located at housing site development districts in Gwangju Metropolitan City since 1990s in order to set applicable color ranges in designing external colors of high-storied apartment houses which became background of street view by types. Consequently, in image changes of four factors of main colors in classified street types, P, RP, R and YR colors showed high average values in naturalness, harmony and unity and GY, G, BG and B colors showed dichotomy with low average value, but image of personality showed generally low average value. RP, R and YR colors showed higher adaptability and GY, G and BG colors showed lower adaptability. It was confirmed that according to adaptability of main colors used in high-storied apartment houses by street types, there was difference of appropriate color range in street components and external colors of high-storied apartment houses by street types.

A Study on the Network Quotient of Employees in Deluxe Hotel according to Demographic Characteristics (특급호텔 종사원의 인구통계적 특성에 따른 인맥지수에 대한 탐색적 고찰)

  • Jung, Hyo Sun;Yoon, Hye Hyun
    • Journal of the Korean Society of Food Culture
    • /
    • v.30 no.4
    • /
    • pp.439-446
    • /
    • 2015
  • This study considered network quotient (NQ) of deluxe hotel employees and schematized characteristic attributes of being selected by employees with image through correspondence analysis in terms of cognition degree. Self-administrated questionnaires were completed by employees (292 samples) and data were analysed by frequency, t-test, one-way ANOVA, reliability and correspondence analysis. First, the hotel employees indicated the high average value in "participating in special education or seminar for improving ability ($3.85{\pm}0.76$). Second, as a result of analyzing difference according to gender, the average value in men was higher than in women. It was indicated that the higher age and career lead to a rise even in the average value of relationship index. Third, in consequence of carrying out correspondence analysis in order to prepare image map according to cognition level on relationship index in hotel employees, the measurement item that is placed in the closest distance to the response as saying of not so very was the response as saying of "having a lunch (dinner) engagement twice or three times a week." On the other hand, the response as saying of "tending to have many acquaintances compared to coworkers" was schematized in the close distance to the response as saying of very so.

A Study on the Tracking of Count-Based Volumetric Changes in Nuclear Medicine Imaging (핵의학 영상에서 계수기반 체적변화 추적에 관한 고찰)

  • Ji-Hyeon Kim;Jooyoung Lee;Hoon-Hee Park
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.57-69
    • /
    • 2024
  • Purpose: Quantitative analysis through count measurement in nuclear medicine planar images is limited by analysis techniques that are useful for obtaining various clinical information or by organ overlap or artifacts in actual clinical practice. On the other hand, the use of SPECT tomography images is quantitative analysis using volume rather than planar, which is not only free from problems such as projection overlap, but also has excellent quantitative accuracy. In the use of developing SPECT quantitative analysis technology, this study aims to compare the accuracy of quantitative analysis between ROI of the conventional planar images and VOI of the SPECT tomographic images in evaluating the count change happened by the volume change of the source. Materials and Methods: A 99mTcO4- source(200.17 MBq) was filled with sterilized water in the syringe to create a phantom with an inner diameter volume of 60 cc, and a planar image and a SPECT image were obtained by reducing the volume by 15 cc (25%) respectively. ROI and VOI(threshold: 1~45%, 5% interval) were set for each image obtained to estimate true count and measure the total count, and compared with the preseted volumetric change rate(%). Results: When volume changes of 25%, 50%, and 75% occurred in the initial volume of 60 cc(100%) of the phantom, the average count changes of the measured planar image were 26.8%, 53.2%, 77.5%, and the average count changes of the SPECT image were 24.4%, 50.9%, and 76.8%. In this case, the VOI size(cm3) set showed an average change rate of 25.4%, 51.1%, and 76.6%. The highest threshold value for the accuracy of radioactive concentration by VOI size (average error -1.03%) was 35%, and the VOI size of the same threshold had an error of -17.1% on average compared to the actual volume. Conclusion: On average, the count-based volumetric change rate in nuclear medicine images was able to track changes more accurately using VOI than ROI, but there was no significant difference with relatively similar value. However, the accuracy of radioactive concentration according to individual VOI sizes did not match, but it is considered that a relatively accurate quantitative analysis can be expected when the size of VOI is set smaller than the actual volume.

Radiographic examination protocol and patient dose in lateral cephalometric radiography in Korea (국내 의료기관에서 측방두부규격방사선촬영시 임상에서의 촬영조건 및 환자 선량)

  • Choi, Jin-Woo
    • Imaging Science in Dentistry
    • /
    • v.40 no.4
    • /
    • pp.165-169
    • /
    • 2010
  • Purpose : To survey the radiographic examination protocol for lateral cephalometric radiographic examinations and to measure their patient doses in Korea and to compare the dose according to the size of hospital, the type of image receptor system, and the installation duration. Materials and Methods : The radiographic examination protocols (kVp, mA, and exposure time) for lateral cephalometric radiography were surveyed with 61 cephalometric radiographic equipments and their patient dose-area product (DAP) measured with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for 51 cephalometric radiographic equipments. The radiographic examination protocols and patient doses were compared according to the size of hospital (university dental hospital, dental hospital, and dental clinic), the type of image receptor system (film-based, DR and CR type) and the installation duration, respectively. SPSS 12.0.1 for Windows (SPSS Inc., Chicago, USA) was used for independent t-test and ANOVA test. Results : The average protocols were 77.0 kVp, 12.7 mA, 6.2 second for cephalometric radiography. The average patient dose (DAP) was $128.0mGy\;cm^2$ and 3rd quartile dose (DAP) $161.1mGy\;cm^2$ for cephalometric radiography for adult male. There was no statistically significant difference at average patient DAP according to the size of hospital, the type of image receptor system, and the installation duration, repectively. Conclusion : The average patient dose was $128.0mGy\;cm^2$ and the third quartile patient dose $161.1mGy\;cm^2$ for lateral cephalometric radiography for adult male in Korea.

THE COMPARATIVE EVALUATION OF FILM-SCREEN COMBINATIONS (증감지와 필름에 따른 방사선상 변화에 대한 연구)

  • Choi Gyeong Ja;Choi Syng Kyu
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.18 no.1
    • /
    • pp.213-225
    • /
    • 1988
  • This study was to compare the quality of image by different screen and film combinations. Using the sensitometer measured the speed and average gradient of blue sensitive films and orthochromatic films. The films was combined with rare earth screen LR, LM, LF and conventional screen OM, OH, XOR, OKa and exposed the step wedge to impulse 2, 3, 4, 6, 10, 15, 24,3 8, 60 and measured the density. The following results were obtained: 1. The density of film and film-screen combinations showed significant difference, then in film-screen combinations was significantly different by the screens than films. 2. The speed of blue sensitive films was little different, the TMG of orthochromatic films produced high speed, and the AX film was high average gradient. 3. The relative speed of film-screen combinations showed significant difference, and was high in the OKa of the conventional screens and in the LR of the rare earth screens, especially that of LR screen in the combination with blue sensitive films was high. 4. The average gradient of film-screen combinations showed no significant difference, and was high in the OKa screen and LR/OG combination, and that of OKa/AX combination was highest. 5. The latitude of film-screen combinations showed significant difference by screens, and was high in the LM screen in combination with blue sensitive films and in the OM screen in combination with orthochromatic films. 6. The subject contrast of film-screen combinations showed significant difference by screen, and was high in the LR screen in combination with blue sensitive AX film and orthochromatic TMG film.

  • PDF