• 제목/요약/키워드: Average current

검색결과 3,257건 처리시간 0.036초

Average Current Controlled X-Y Channel Driving White LED Backlight System for 46" LCD TV

  • Cho, Dae-Youn;Oh, Won-Sik;Cho, Kyu-Min;Moon, Gun-Woo;Yang, Byung-Choon;Jang, Tae-Seok
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.271-273
    • /
    • 2008
  • A novel white-LED (light emitting diode) backlight system for 46"LCD TVs which involves the average current controlled X-Y channel driving method is proposed, which is composed of 1 converter and row and column channel switches. In the conventional X-Y channel driving driven with a constant voltage source, the driving current of LED increases because the threshold voltage of LED decreases when LED temperature goes up. To maintain the luminance of backlight constant, the average current controlled X-Y channel driving will be employed. Finally the results are confirmed by experimental results.

  • PDF

능동 클램프 방식을 이용한 AC/DC ZVT 승압형 컨버터의 평균전류모드 제어에 관한 연구 (A Study on the Average Current-Mode Control AC/DC ZVT-Boost Converter with Active-Clamp Method)

  • 배진용;김용;김필수;임남혁;윤석호;장성원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1005-1008
    • /
    • 2001
  • This paper presents average current-mode control AC/DC ZVT(Zero Voltage Transition) Boost Converter. This boost converter perceives feed forward signal of input and feedback signal of output for average current-mode control proposed converter employs active-clamp method for ZVT. This converter gives the good PFC(Power Factor Correction), low line current hormonic distortions and tight output voltage regulations. This converter also has a high efficiency by active-clamp method. The principle of operation, feature, and design considerations are illustrated and verified through the experiment with a 150W, 120kHz prototype converter.

  • PDF

PLC의 PID 제어에 의한 자동차용 타이어 하중제어에 관한 연구 (Development for Tire Load Control System using PLC PID function)

  • 이기성;정태원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 D
    • /
    • pp.2352-2354
    • /
    • 2003
  • An apparatus and method for imposing a desired average radial force on tire by calculating the current average force between the tire and load wheel based on the average radial force and radial distance between the tire load wheel over the last previous complete revolution of the tire, the spring constant of the tire and the current radial distance between the tire and the load wheel.

  • PDF

LDPE에서 부시형 전기트리의 성장에 수반되는 부분방전 펄스의 특성 (Properties of PD Pulses accompanying with propagation of Bush-type tree in LDPE)

  • 박영국;강성화;정수현;박철현;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.293-296
    • /
    • 1998
  • Surface electrical conduction in insulator is most important factor to assess the insulation performances of outdoor insulating materials. In this paper, contamination performance of the widely used materials for outdoor insulator - porcelain, EPDM, Silicone rubber - were discussed by measuring properties of average leakage current and scintillation discharge pulses under artificial contamination conditions. The artificial contaminations used were deionized distilled water fog, 0.5wt% NaCl salt fog of light pollution and 2wt% NaCl salt fog of medium pollution. The average leakage current was appeared linearly with applied voltage at dry and clean surface condition. The magnitude of leakage current was almost same at different kinds of samples. In case of deionized distilled water fog, the characteristics of leakage current and applied voltage was most different to that in case of dry and clean condition. In case of salt fog pollution condition, The leakage current was increased above critical voltage. The scintillation discharges were also activated at the level. the leakage current and scintillation discharges were increased with increasing pollution degree. The resistance to pollution properties of silicone rubber appeared excellent among them.

  • PDF

개선된 평균 전류 제어 방식 역률 개선 회로의 제어에 관한 연구 (A Study on the control of Power Factor Correction Circuit by Advanced Average Current Control)

  • 김태규;김태우;최현의;김민찬;안호균;윤태성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.999_1000
    • /
    • 2009
  • The purpose of this paper is a study on the control of Power Factor Correction circuit by advanced average current control. The international standard organizations have made an effort to resolve these problems caused by the harmonics and announced the international standards for limiting the harmonic currents of the electrical devices and products. For improving power factor and reducing harmonics, many studies are progressed rapidly. In this study, we explain a method of an advanced average current control. And then, the performances of the PFC circuit applying a advanced average current control method are simulated and verified by Matlab/Simulink.

  • PDF

태양전지를 이용한 원격조종 중경제초기 개발 (Development of a Remote Controlled Weeder Driven by Solar Battery Power)

  • 김태수;장익주
    • Journal of Biosystems Engineering
    • /
    • 제32권2호
    • /
    • pp.91-96
    • /
    • 2007
  • In this study, a prototype remote controlled weeder using solar module was developed and the evaluations of weeding, side walking and weeding performance were conducted to see if actual application was feasible in the paddy field. When traveling, the loss electric current was 8 to 15 A depending on operating and soil conditions. The average traveling speed was 0.25 m/s and the average slippage was 18%. When it side walked row by row, electric current consumption was 7 A on the average. When wheel rotors line went initially up and last down, electric current consumption was 12 to 15 A due to soil resistance. Electric current consumption when shifting wheel rotors line was less than 5 A due to no resistance. Field efficiency was 105 min/10a based on the test field. Operation was able to be done for 4.16 hours continually by 52 AH battery based on 300 W average maximum power consumption and 4.6 hours under sunny day considering solar module.

DSP를 이용한 부스트 컨버터의 전류 제어기 설계 및 구현 (Design and Implementation of a Current Controller for Boost Converters Using a DSP)

  • 이광운
    • 전력전자학회논문지
    • /
    • 제17권3호
    • /
    • pp.259-265
    • /
    • 2012
  • This paper introduces a method for design and implementation of a current controller for boost converter operating in continuous conduction mode (CCM) using a digital signal processor (DSP). A Proportional-Integral (PI) type current controller outputs an average voltage command for inductor, used in the input side of the boost converter, and the duty-ratio of PWM (pulse width modulation) signal for switching device is directly calculated from the average voltage command. The gains of the PI current controller are selected such that the current response characteristics are the same as those of a first-order low-pass filter. The proposed current control scheme is implemented using a DSP based on fixed-point math operations and an experimental study has been performed to validate the proposed method.

주축 및 Z축 모터전류를 이용한 드릴파손 예측에 관한 연구 (Study on Prediction of Drill Breakage using Spindle and Z-axis Motor Currents)

  • 김화영;안중환
    • 한국정밀공학회지
    • /
    • 제16권7호
    • /
    • pp.101-108
    • /
    • 1999
  • A reliable and practical monitoring of drill breakage is a crucial technique in automatic machining system. In this study, a real-time monitoring system was developed to predict drill breakage using both spindle and z-axis motor current. Drill breakage is monitored by detecting the level of residual motor current which is obtained through the moving average filter algorithm. The residual exhibits a feature of sharp decrease just before drill breakage. Therefore, drill breakage can be predicted by detecting this characteristic of residual component. Z-axis motor current is better to predict the drill breakage than spindle motor current, because the former is faster in response than the latter when drill breakage is occurred. The evaluation experiments have shown that the developed monitoring system works very well.

  • PDF

A simplified method to determine the chloride migration coefficient of concrete by the electric current in steady state

  • Lin, K.T.;Yang, C.C.
    • Computers and Concrete
    • /
    • 제13권1호
    • /
    • pp.117-133
    • /
    • 2014
  • This study presents a rapid method for determining the steady state migration coefficient of concrete by measuring the electric current. This study determines the steady state chloride migration coefficient using the accelerated chloride migration test (ACMT). There are two stages to obtain the chloride migration coefficient. The first stage, the steady-state condition was obtained from the initial electric current at the beginning of ACMT. The second stage, the average electrical current in the steady state condition was used to determine the steady state chloride migration coefficient. The chloride migration coefficient can be determined from the average steady state current to avoid sampling and analyzing chlorides during the ACMT.

GMAW 공정에서 아크 안정성의 실시간 측정 (Real-time estimation of arc stability in GMAW process)

  • 원윤재;부광석;조형석
    • Journal of Welding and Joining
    • /
    • 제8권1호
    • /
    • pp.31-42
    • /
    • 1990
  • Arc must be stable during welding first of all other factors for obtaining sound weldment, especially in the automation of welding process. Arc stability is somewhat sophisticated phenomenon which is not clearly defined yet. In consumable electrode welding, the voltage and current variation due to metal transfer enables to assess arc stability. Recently, statistical analyses of the voltage and current waveform factors are performed to assess the degress of arc stability which is assessed and controlled by operator's own experience by now. But, considering the increasing need and the trend of automation of welding process, it is necessary to monitor arc stability in real-time. In this sutdy, the modified stability index composed of two voltage and current wvaeform factors (arc time and short circuit time) reduced from four factors (arc time, short circuit time, average arc current and average short circuit current) in Mita's index by the welding electrical circuit modeling is proposed and verified by experiments to be well estimating arc stability in the static sense. Also, the recursive calculation form estimating present arc stability in the dynamic sense is developed for real-time estimation. The results of applying the recursive index during welding show good estimation of arc stability in real-time. Therefore, the results of this study offers the mean for real-time control arc stability.

  • PDF