• Title/Summary/Keyword: Average Volume Method

Search Result 534, Processing Time 0.029 seconds

Malaria Epidemic Prediction Model by Using Twitter Data and Precipitation Volume in Nigeria

  • Nduwayezu, Maurice;Satyabrata, Aicha;Han, Suk Young;Kim, Jung Eon;Kim, Hoon;Park, Junseok;Hwang, Won-Joo
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.5
    • /
    • pp.588-600
    • /
    • 2019
  • Each year Malaria affects over 200 million people worldwide. Particularly, African continent is highly hit by this disease. According to many researches, this continent is ideal for Anopheles mosquitoes which transmit Malaria parasites to thrive. Rainfall volume is one of the major factor favoring the development of these Anopheles in the tropical Sub-Sahara Africa (SSA). However, the surveillance, monitoring and reporting of this epidemic is still poor and bureaucratic only. In our paper, we proposed a method to fast monitor and report Malaria instances by using Social Network Systems (SNS) and precipitation volume in Nigeria. We used Twitter search Application Programming Interface (API) to live-stream Twitter messages mentioning Malaria, preprocessed those Tweets and classified them into Malaria cases in Nigeria by using Support Vector Machine (SVM) classification algorithm and compared those Malaria cases with average precipitation volume. The comparison yielded a correlation of 0.75 between Malaria cases recorded by using Twitter and average precipitations in Nigeria. To ensure the certainty of our classification algorithm, we used an oversampling technique and eliminated the imbalance in our training Tweets.

A Longitudinal Study on Human Milk Volume in Lactating Women During the First 6 Months of Lactation (수유 첫 6개월간 기간별 수유부의 모유분비량에 관한 연구)

  • 설민영
    • Journal of Nutrition and Health
    • /
    • v.26 no.4
    • /
    • pp.405-413
    • /
    • 1993
  • The longitudinal changes on human milk volume of 27 Korean lactating women (primiparae=10, multiparac=17) from 0.5 to 6 months after parturition have been studied by test-weighing method in Cheongju and Anseong area. The human milk volume per day increased to 2 months postpartum, and then decreased during lactation. The mean volume(g/day) at 0.5, 1, 2, 3, 4, 5, and 6 months were 634, 810, 847, 840, 844, 810, and 732g, respectively. The average volume were 791 ($\pm$149) and 786($\pm$131)g for primiparae and multiparae, respectively. The overall mean volume was 788$\pm$135g/day. The distributions of the individual mean volume during the first 6 months of lactation were found 450~549g(3.7%), 550~649g(11.1%), 650~749g(22.2%), 750~849%(37.1%), 850~949g(18.6%), 950~1049g(3.7%), and 1050~1149g(3.7%). The mean volume between primiparae and multiparase was significantly lower than other periods. The peak milk volume during the lactation was observed at 3 months postpartum for primiparae(40%), 2 months postpartum for multiparae(35.3%), and 2 months postpartum for total lactating women(29.6%). The volume of human milk had a significant positive correlation with peak volume and infant milk intake, but no correlation with maternal age, weight before delivery, height, and birth weight.

  • PDF

Evaluation of Masseter Muscle Volume after Contouring of Prominent Mandible Angle by Measurement of CT Scan Image

  • Kim, Yong Oock;Choi, Jong Woo
    • Journal of International Society for Simulation Surgery
    • /
    • v.1 no.2
    • /
    • pp.71-74
    • /
    • 2014
  • Purpose The prominent mandible angle, otherwise known as "square face", has been recognized as an aesthetic problem that needs correction by many in the Asian community. Many surgeons considered that mandible angle ostectomy alone, brings about hypotrophy of the masseter muscle. However, it was only proven indirectly (by clinical experience and histological animal experiments) and not objectively. In this study, we evaluated the volume of masseter muscle to prove the effect, objectively. Materials and method Computed tomography (CT) images were used to measure the masseter muscle volume of normal female group (n=6), and of female patient group n=8, preoperative and early & late postoperative volumes) presenting the symptom of prominent mandible angle. The data was analyzed statistically by two-sample t-test and paired t-test using SAS (version 8.2). Results In normal female group, volume average was $16,142{\pm}2,829.8mm^3$. In patient group, preoperative volume averaged $24,447{\pm}4,544.5mm^3$ (p<0.0001), early postoperative volume measured average of $31,966{\pm}50,421mm^3$ which is a 30% increase from the preoperative volume (p<0.0001). Late postoperative measurement was $20,202{\pm}4,092.3mm^3$, which is a 20% decrease from the preoperative volume (p<0.0006). Conclusion The bone reduction of prominent mandible angle induce the hypotrophic effect of masseter muscle after long term follow up (5 more months). This result mean that the result of mandible angle contouring surgery can be considered as combined effect of bony angle reduction and subsequent masseter muscle hypotrophy.

Finite element solutions of natural convection in porous media under the freezing process (동결과정을 포함한 다공층에서 자연대류에 대한 유한요소 해석)

  • Lee, Moon-Hee;Choi, Chong-Wook;Seo, Suk-Jin;Park, Chan-Guk
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.51-56
    • /
    • 2000
  • The Finite Element Solutions Is reported on solid-liquid phase change in porous media with natural convection including freezing. The model is based on volume averaged transport equations, while phase change is assumed to occur over a small temperature range. The FEM (Finite Element Method) algorithm used in this study is 3-step time-splitting method which requires much less execution time and computer storage the velocity-pressure integrated method and the penalty method. And the explicit Lax-Wendroff scheme is applied to nonlinear convective term in the energy equation. For natural convection including melting and solidification the numerical results show reasonable agreement with FDM (Finite Difference Method) results.

  • PDF

MR-based Partial Volume Correction for $^{18}$F-PET Data Using Hoffman Brain Phantom

  • Kim, D. H.;Kim, H. J.;H. K. Jeong;H. K. Son;W. S. Kang;H. Jung;S. I. Hong;M. Yun;Lee, J. D.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.322-323
    • /
    • 2002
  • Partial volume averaging effect of PET data influences on the accuracy of quantitative measurements of regional brain metabolism because spatial resolution of PET is limited. The purpose of this study was to evaluate the accuracy of partial volume correction carried out on $^{18}$ F-PET images using Hoffman brain phantom. $^{18}$ F-PET Hoffman phantom images were co-registered to MR slices of the same phantom. All the MR slices of the phantom were then segmented to be binary images. Each of these binary images was convolved in 2 dimensions with the spatial resolution of the PET. The original PET images were then divided by the smoothed binary images in slice-by-slice, voxel-by-voxel basis resulting in larger PET image volume in size. This enlarged partial volume corrected PET image volume was multiplied by original binary image volume to exclude extracortical region. The evaluation of partial volume corrected PET image volume was performed by region of interests (ROI) analysis applying ROIs, which were drawn on cortical regions of the original MR image slices, to corrected and original PET image volume. From the ROI analysis, range of regional mean values increases of partial volume corrected PET images was 4 to 14%, and average increase for all the ROIs was about 10% in this phantom study. Hoffman brain phantom study was useful for the objective evaluation of the partial volume correction method. This MR-based correction method would be applicable to patients in the. quantitative analysis of FDG-PET studies.

  • PDF

A Method for Fuzzy-Data Processing of Cooked-rice Portion Size Estimation (식품 눈대중량 퍼지데이타의 처리방안에 관한 연구)

  • 김명희
    • Journal of Nutrition and Health
    • /
    • v.27 no.8
    • /
    • pp.856-863
    • /
    • 1994
  • To develop a optimized method for educing the errors associated with the estimation of portion size of foods, fuzzy-dta processing of portion size was performed. Cooked-rice was chosen as a food item. The experiment was conducted in two parts. First, to study the conceptions of respondents to bowl size(large, medium, small), 11 bowls of different size and shape were used and measured the actual weights of cooked-rice. Second, to study the conceptions of respondents to volume(1, 1/2, 1/3, 1/4), 16 different volumes of cooked-rice in bowls of same size and shape were used. Respondents for this study were 31 graduate students. After collecting the data of respondents to size and volume, fuzzy sets of size and volume were produced. The critical values were calculated by defuzzification(mean of maximum method, center of area method). The differences of the weights of cooked-rice in various bowl size and volume between the critical values and the calculated values by average portion size using in conventional methods were compared. The results hows large inter-subject variation in conception to bowl size, especially in large size. However, conception of respondents to volume is relatively accurate. Conception to bowl size seems to be influenced by bowl shape. Considering that the new fuzzy set was calculated by cartesian product(bowl size and volume), bowl shape should be considered in estimation of bowl size to make more accurate fuzzy set for cooked-rice portion size. The limitations of this study were discussed. If more accurate data for size and volume of many other food items are collected by the increased number of respondents, reducing the errors associated with the estimation of portion size of foods and rapid processing will be possible by constructing computer processing systems.

  • PDF

A Spatial Average Method Using 2nd Order Sampling in Ultrasonic Doppler System (초음파 도플러 시스템에서 2차 샘플링을 이용한 공간축상의 평균 방법)

  • 백광렬
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.279-288
    • /
    • 1995
  • Ultrasonic Doppler systems for the purpose of estimating blood flow velocity, blood flow volume, and flow imaging are commonly used due to advantages of non-invasive and real time observation. Specially, the technical developments of color flow mapping (2-D Doppler) systems have made a relatively rapid progress. However, the 2-D Doppler systems have several problems, such as the range ambiguity, low signal to noise ratio, and slow frame rate. The slow frame rate problem is resolved by using the spatial average which is a method to acquire more data samples for mean frequency estimation. In this paper, spatial average method using the 2nd order sampling instead of quadrature sampling is proposed. The experimental results show that the proposed methods have good performance and easy application to the color flow mapping system.

  • PDF

Significance Evaluation of Lung Volume and Pulmonary Dysfunction (폐용적과 폐기능 환기장애에 대한 유의성 평가)

  • Ji-Yul Kim;Soo-Young Ye
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.767-773
    • /
    • 2023
  • To In this study, we sought to evaluate related factors affecting lung volume and their significance in pulmonary function and ventilation disorders. As experimental subjects, 206 normal adult men and women who underwent a low-dose chest CT scan and a spirometry test were selected at the same time. The experimental method was to measure lung volume using lung CT images obtained through a low-dose chest CT scan using deep learning-based AVIEW. Measurements were made using the LCS automatic diagnosis program. In addition, the results of measuring lung function were obtained using a spirometer, and gender and BMI were selected as related factors that affect lung volume, and significance was evaluated through an independent sample T-test with lung volume. As a result of the experiment, it was confirmed that in evaluating lung volume according to gender, all lung volumes of men were larger than all lung volumes of women. he result of an independent samples T-test using the respective average values for gender and lung volume showed that all lung volumes were larger in men than in women, which was significant (p<0.001). And in the evaluation of lung volume according to BMI index, it was confirmed that all lung volumes of adults with a BMI index of 24 or higher were larger than all lung volumes of adults with a BMI index of less than 24. However, the independent samples T-test using the respective average values for BMI index and lung volume did not show a significant result that all lung volumes were larger in BMI index 24 or higher than in BMI index less than 24 (p<0.055). In the evaluation of lung volume according to the presence or absence of pulmonary ventilation impairment, it was confirmed that all lung volumes of adults with normal pulmonary function ventilation were larger than all lung volumes of adults with pulmonary ventilation impairment. And as a result of the independent sample T-test using the respective average values for the presence or absence of pulmonary ventilation disorder and lung volume, the result was significant that all lung volumes were larger in adults with normal pulmonary function ventilation than in adults with pulmonary function ventilation disorder (p <0.001). Lung volume and spirometry test results are the most important indicators in evaluating lung health, and using these two indicators together to evaluate lung function is the most accurate evaluation method. Therefore, it is expected that this study will be used as basic data by presenting the average lung volume for adults with normal ventilation and adults with impaired lung function and ventilation in similar future studies on lung volume and vital capacity testing.

The Estimation of Volume Conversion Factor of Rock Fill using Field Density Test (현장밀도시험을 이용한 암성토 체적환산계수 산정에 관한 연구)

  • Park, Jong-Beom;Ma, Myong-Soo
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.1
    • /
    • pp.9-17
    • /
    • 2017
  • In this study, the field density test was conducted as a volume conversion factor for the design of the excavation soil of the blasting rock. As a result of the field density test, the average volume conversion factor of rock was 1.001, which was smaller than the volume conversion factor of weathered rock 1.1. In the case of rock filled soil, the causes of the increase and decrease of the volume of the soil are provided by various phenomena. However, the specific techniques such as investigation and test methods are insufficient. Therefore, it was confirmed that the method of field density test is very useful method.

Sleep Apnea Detection using Estimated Stroke Volume (추정된 일회심박출량을 이용한 수면 무호흡 검출)

  • Lee, Junghun;Lee, Jeon;Lee, Hyo-Ki;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.97-103
    • /
    • 2013
  • This paper proposes a new algorithm for sleep apnea detection based on stroke volume. It is very important to detect sleep apnea since it is a common and serious sleep-disordered breathing (SDB). In the previous studies, methods for sleep apnea detection using heart rate variability, airflow and blood oxygen saturation, tracheal sound have been proposed, but a method using stroke volume has not been studied. The proposed algorithm consists of detection of characteristic points in continuous blood pressure signal, estimation of stroke volume and detection of sleep apnea. To evaluate the performance of algorithm, the MIT-BIH Polysomnographic Database provided by Phsio- Net was used. As a result, the sensitivity of 85.99%, the specificity of 72.69%, and the accuracy of 84.34%, on the average were obtained. The proposed method showed comparable or higher performance compared with previous methods.