• Title/Summary/Keyword: Average Total Inspection

Search Result 79, Processing Time 0.023 seconds

Study on Strain Response Converted from Deformation in Tensile Test of Carbon Fiber Reinforced Polymers (CFRP) (탄소섬유보강폴리머의 인장시험시 변형으로부터 환산한 변형률 응답에 대한 연구)

  • Kim, Yun-Gon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.137-144
    • /
    • 2019
  • In coupon test of carbon fiber reinforced polymers (CFRP) as brittle materials, the converted strain derived from total deformation and effective length was introduced and its advantages were described. In general, measured value from strain gauge is used for determining the tensile properties of material, but it is not quite effective in CFRP because brittle material can not redistribute its stress and it only represents local behavior. For this reason, the converted strain response can be utilized effectively as a supplementary indicator, which evaluated the average value of tensile properties in brittle material and confirmed the strain measured by strain gauge. In addition, the converted strain clearly visualized 1) the effect of initial internal strain caused by fabrication errors and setup misalignment when applying gripping force and 2) post-response of partial rupture of CFRP caused by non-uniform strain distribution. non-uniform strain distribution.

Peroneal Perforator Flap (비골 동맥 천공지 피판)

  • Chung, Duke Whan;Hwang, Joon Sung
    • Archives of Reconstructive Microsurgery
    • /
    • v.13 no.1
    • /
    • pp.29-35
    • /
    • 2004
  • Materials and Methods: Total number of peroneal perforator flap is 14 cases, which 10 cases were man, 4 cases were woman. The range of age was 12 years old minimally and until 63 years old. The trauma was most common etiology, which was like traffic accidents, 9 cases. We confirmed tibialis anterior artery patency by doppler flow meter, angiography as preoperative evaluation. Results: 1. The success rate was 91%, that in 14 cases, 13 cases were succeded. 2. To obtain successful result of peroneal flap, one must have the anatomic concept for vascular pattern, 8 cases were between peroneus muscle and soleus muscle branch type but, 3 cases were through soleus muscle branch type, so we treated these cases by using soleus muscle including peroneal perforating branch not to injury perforating artery directly. 3. The pedicle size was between minimally $2{\times}2.5cm$ and maximally $6.5{\times}8.5cm$ so we could treat large recipient site. 4. The pedicle length was between minimally 3.2 cm and maximally 11.5cm, average 7.5 cm. 5. The diameter of perforating artery was estimated by inspection, that was about 0.2-0.5 cm Conclusion: The peroneal perforating artery flap has merits that we can approach in avascular zone and has wide movable range from foot to distal femur and little donor site mobidity and can harvest osteocutaneous flap. The weak point was the irregular anatomy of nutrient artery and not to contain sensory nerve.

  • PDF

Evaluation on the Horizontal Shear Strength of Precast Concrete Slab with the Inverted-Rib-Plus (리브플러스 PC슬래브의 수평전단강도 평가)

  • Park, Keum Sung;Lee, Sang Sup;Choi, Yun Cheul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.6
    • /
    • pp.156-165
    • /
    • 2011
  • This study investigates the horizontal shear behavior of an interface between precast concrete (PC) and topping concrete(RC), and evaluates the horizontal based on the investigations by the experimental. Horizontal shear strength in connected surface is determined by the roughness an interface and the shear reinforcement or not. In this study, the main experimental parameters are the shear reinforcement types in the shape of loop-type and lattice-type, rebar spacing. A total of four specimens were shear strength tested and manufactured. As a result, the horizontal shear strength of reinforced connected surface was found to be controlled by deformation in vertical direction. Comparison of reinforcement shape, the mean initial crack load loop type specimens, the average maximum load and the junction of the average in terms of initial stiffness, respectively 33.7%, 45.9% and 55.2% were large enough. Evaluation results for shear strength equation of existing standard domestic, the loop-type reinforced 2.32 to 4.23 times, lattice-type reinforced 1.65 to 3.06 times appears to be higher. Behavior of interface or strength of structural design criteria was fairly safe side. It does not have any problems in the applied field is considered.

Study on Tensile Properties of Carbon Fiber Reinforced Polymers (CFRP) Laminate with Strain Distribution (변형률 분포를 가진 탄소섬유복합체의 인장특성에 대한 연구)

  • Kim, Yun-Gon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.25-33
    • /
    • 2020
  • To investigate the relationship between strain distribution and tensile properties of brittle material, five types of tensile coupon of carbon fiber reinforced polymer (CFRP) modified the tab portion in order to have a strain distribution including S0, SD1, SD2, SV1, SV2 were tested. The ultimate stress and strain of SD2 and SV2 which was intended to have larger strain distribution were smaller than those of SD1 and SV1, that was more clearly shown in the test results of the symmetric coupons (SV series) than the asymmetric coupons (SD series). In addition, the ultimate stress and strain of most coupons with strain distribution in this study were decreased when compared to the control group with uniform strain. These results were analyzed in various ways through 1) the average of the strain values directly measured by the strain gages, 2) the converted strain calculated by dividing the total deformation by the effective length, and 3) the ultimate effective strain derived from both the elastic modulus and the ultimate load. The values measured by strain gage indicates response of the local region precisely, but it does not represent the response from whole section. However, the converted strain and effective strain can supplement disadvantage of gage because they represent the average response of whole section. In particular, the effective strain can provide rupture strain conservatively, which can be utilized in practice, when the value obtained by strain gage was not effective due to gage damage or abnormal gage readings near ultimate load. This value provides a value that can be used even when partial rupture has occurred and is reasonably useful for specimens with strain distribution.

The Assessment of Exposure Dose of Radiation Workers for Decommissioning Waste in the Radioactive Waste Inspection Building of Low and Intermediate-Level Radioactive Waste Disposal Facility (경주 중·저준위방사성폐기물 처분시설의 방폐물검사건물에서 해체 방사성폐기물 대상 방사선작업종사자의 피폭선량 평가 및 작업조건 도출)

  • Kim, Rin-Ah;Dho, Ho-Seog;Kim, Tae-Man;Cho, Chun-Hyung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2_spc
    • /
    • pp.317-325
    • /
    • 2020
  • The Korea Radioactive Waste Agency plans to expand the storage capacity of radioactive waste by constructing a radioactive waste inspecting building to solve the problem of the lack of inspection space and drum-handling space in the radioactive waste receipt and storage building for the first-stage disposal facility. In this study, the exposure doses of radiation workers that handle new disposal containers for decommissioning waste in the storage areas of the radioactive waste inspecting building were calculated using the Monte Carlo N-particle transport code. The annual collective dose was calculated as a total of 84.8 man-mSv for 304 new disposal containers and an estimated annual 306 working hours for the radiation work. When the 304 new disposal containers (small/medium type) were stored in the storage areas, it was found that 25 radiation workers should be involved in acceptance/disposal inspection, and the estimated exposure dose per worker was calculated as an average annual value of 3.39 mSv. When the radiation workers handle the small containers in high-radiation dose areas, the small containers should be shielded further by increasing the concrete liner thickness to improve the work efficiency and radiation safety of the radiation workers. The results of this study will be useful in establishing the optimal radiation working conditions for radiation workers using the source term and characteristics of decommissioning waste based on actual measurements.

Research For Reducing Patient Dose that Low Extremity CT Angiography Using Automatic Current Selection (하지동맥조영 전산화단층촬영에서 자동선량 조절장치를 이용한 환자선량 감소 연구)

  • An, Hyeong-Theck;Kim, Jae-Yeol;Yeo, Woon-Sik;Park, Yong-Sung;Lee, Gui-Won;Lee, Jong-Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.45-53
    • /
    • 2013
  • Purpose : Fixed way of mAs previously Low Extremity Computed Tomography Angiography(LECTA) examination were used. Automatic Current Selection(ACS) to use for the purpose of reducing the dose when Low Extremity Computed Tomography Angiography examining patients. Materials and methods : Were analyzed from July 2011 to July 2012 MDCT examination of Dose Length Product(DLP) LECTA 116 Case. It was defined as previous inspection methods(Old protocol). CT workstation is set to 100 mAs and 150 mAs protocol based on the patient's weight 70kg examined by LECTA. We defined as 'New protocol' that applies to ACS. The data collection period are 76 cases from October 2012 to January 2013 Results : 1. Average Total DLP of 'Old protocol' is 3602.943 $mGy^*cm$. 2. Average Total DLP of 'New protocol' is 1762.977 $mGy^*cm$. 3. Due to the 'New Protocol' use of Total DLP was reduced by approximately 51 %. Phase-specific dose reduction is as follows. Pre(33.62 %), Artery(64.63 %), Delay(49.0 %) 4. Using One way ANOVA Analysis of fluctuations obtained DLP is as follows. 'Old protocol', 'New protocol' a value of P < 0.001, P = 0.882 values were obtained. Conclusions : Dose reduction of 51 % is a useful study that proves. The results obtained using the ACS, the effects of a dose reduction of 51 % was obtained. Therefore, it has been proven to be a useful way. Statistics using SPSS version came out of the 'Old protocol' P-value P < 0.0001. This result means that the DLP a large difference values. On the other hand, The results of the 'New protocol' was P = 0.882. These results means to that small and regularly was fluctuations of the dose. The use of ACS, you can get a reduction of the dose and will able to get the effect of reducing the dose errors.

  • PDF

Assessing Irrigation Water Supply from Agricultural Reservoir Using Automatic Water Level Data of Irrigation Canal (관개용수로의 자동수위측정 자료를 활용한 농업용 저수지 공급량 산정 및 분석)

  • Bang, Jehong;Choi, Jin-Yong;Yoon, Pureun;Oh, Chang-Jo;Maeng, Seung-Jin;Bae, Seung-Jong;Jang, Min-Won;Jang, Taeil;Park, Myeong Soo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.1
    • /
    • pp.27-35
    • /
    • 2021
  • KRC (Korea Rural Community Corporation) is in charge of about 3,400 agricultural reservoirs out of 17,240 agricultural reservoirs, and automatic water level gauges in reservoirs and canals were installed to collect reservoir and canal water level data from 2010. In this study, 10-minute water level data of 173 reservoir irrigation canals from 2016 to 2018 are collected, and discharge during irrigation season was calculated using rating curves. For estimation of water supply, irrigation water requirement was calculated with HOMWRS (Hydrological Operation Model for Water Resources System), and the summation of reservoir water storage decrease was calculated with daily reservoir storage data from RAWRIS (Rural Agricultural Water Resource Information System). From the results, the total yearly amount of irrigation water supply showed less than 10% difference than the irrigation water requirement. The regional analysis revealed that reservoirs in Jeollanam-do and Chungcheongnam-do supply greater irrigation water than average. On the contrary, reservoirs in Gyeongsangnam-do and Chungcheongbuk-do supply less than others. This study was conducted with a limited number of reservoirs compared to total agricultural reservoirs. Nevertheless, it can indicate irrigation water supply from agricultural reservoirs to provide information about agricultural water use for irrigation.

Improvement of Certification Criteria based on Analysis of On-site Investigation of Good Agricultural Practices(GAP) for Ginseng (인삼 GAP 인증기준의 현장실천평가결과 분석에 따른 인증기준 개선방안)

  • Yoon, Deok-Hoon;Nam, Ki-Woong;Oh, Soh-Young;Kim, Ga-Bin
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.1
    • /
    • pp.40-51
    • /
    • 2019
  • Ginseng has a unique production system that is different from those used for other crops. It is subject to the Ginseng Industry Act., requires a long-term cultivation period of 4-6 years, involves complicated cultivation characteristics whereby ginseng is not produced in a single location, and many ginseng farmers engage in mixed-farming. Therefore, to bring the production of Ginseng in line with GAP standards, it is necessary to better understand the on-site practices of Ginseng farmers according to established control points, and to provide a proper action plan for improving efficiency. Among ginseng farmers in Korea who applied for GAP certification, 77.6% obtained it, which is lower than the 94.1% of farmers who obtained certification for other products. 13.7% of the applicants were judged to be unsuitable during document review due to their use of unregistered pesticides and soil heavy metals. Another 8.7% of applicants failed to obtain certification due to inadequate management results. This is a considerably higher rate of failure than the 5.3% incompatibility of document inspection and 0.6% incompatibility of on-site inspection, which suggests that it is relatively more difficult to obtain GAP certification for ginseng farming than for other crops. Ginseng farmers were given an average of 2.65 points out of 10 essential control points and a total 72 control points, which was slightly lower than the 2.81 points obtained for other crops. In particular, ginseng farmers were given an average of 1.96 points in the evaluation of compliance with the safe use standards for pesticides, which was much lower than the average of 2.95 points for other crops. Therefore, it is necessary to train ginseng farmers to comply with the safe use of pesticides. In the other essential control points, the ginseng farmers were rated at an average of 2.33 points, lower than the 2.58 points given for other crops. Several other areas of compliance in which the ginseng farmers also rated low in comparison to other crops were found. These inclued record keeping over 1 year, record of pesticide use, pesticide storages, posts harvest storage management, hand washing before and after work, hygiene related to work clothing, training of workers safety and hygiene, and written plan of hazard management. Also, among the total 72 control points, there are 12 control points (10 required, 2 recommended) that do not apply to ginseng. Therefore, it is considered inappropriate to conduct an effective evaluation of the ginseng production process based on the existing certification standards. In conclusion, differentiated certification standards are needed to expand GAP certification for ginseng farmers, and it is also necessary to develop programs that can be implemented in a more systematic and field-oriented manner to provide the farmers with proper GAP management education.

A Review on Floating Photovoltaic Technology (FPVT)

  • Yousuf, Hasnain;Khokhar, Muhammad Quddamah;Zahid, Muhammad Aleem;Kim, Jaeun;Kim, Youngkuk;Cho, Eun-Chel;Cho, Young Hyun;Yi, Junsin
    • Current Photovoltaic Research
    • /
    • v.8 no.3
    • /
    • pp.67-78
    • /
    • 2020
  • A novel energy production system which has fascinated a wide consideration because of its several benefits that are called floating photovoltaic technology (FPVT). The FPVT system that helps to minimize the evaporation of water as well as an increase in energy production. For the research purposes, both electrical and mechanical structure requires studying of these systems for the development of FPVT power plants. From different points of views, numerous researches have been directed on FPVT systems that have evaluated these systems. The present research article give a logical investigation and up to date review that shows the different features and components of FPVT systems as an energy production system is offered. This articles reviewing the FPVT that gets the attention of the scientists who have the investigational stage and involuntary inspection of FPVT systems in addition to influence of implementing these systems on the water surface. Also, a comprehensive comparison has been constructed that shows the cons and pros of various types of solar systems that could be installed in various locations. In this review, it has been found that solar energy on the roof of a dwelling house generally has a power of 5 to 20 kW, while the inhabitants of commercial buildings generally have a power of 100 kW or more. The average power capacity of a floating solar panel is 11% more of the average capacity of a solar panel installed on the ground. Studies show that 40% of the water in open reservoirs is lost through evaporation. By covering only 30% of the water surface, evaporation can be reduced by 49%. The global solar panel market exceeds 100 GW and the capacity of 104 GW will bring the annual growth rate to 6%. In 2018, the world's total photovoltaic capacity reached 512 GW, an increase of 27% compared to the total capacity and about 55% of the renewable resources newly created that come from photovoltaic systems. It has been also predicted by this review that in 2025 the Solar technology including the FPVT system will increase by 7.38% that is 485.4 GW more of today installed power worldwide.

Artificial Insemination with Low-Dose Semen does not affect Swine Reproductive Performances

  • Chung, Ki-Hwa;Lee, Il-Joo;Sa, Soo-Jin;Kim, In-Cheul;Jung, Byeong-Yeal;Son, Jung-Ho
    • Reproductive and Developmental Biology
    • /
    • v.37 no.4
    • /
    • pp.263-267
    • /
    • 2013
  • Pig producers have been shown keen interest of the number of spermatozoa in a semen dose since pig artificial insemination introduce. However, determining the minimal number of spermatozoa need per AI without detrimental effect on overall reproductive performances is not an easy question to answer. To increase the efficiency of semen utilization in pig AI, optimum number of spermatozoa per dose needed to determine. The objective of this study was to determine the reproductive performance and factors that affect on-farm application of low-dose semen insemination in sows. Data were collected from Darby Genetics AI studs from 4th of June to 7th of July, 2012 (n=401). The numbers of parturition were 84, 234 and 83 in sows inseminated with doses of $1.5{\times}10^9$, $2.0{\times}10^9$ and $2.5{\times}10^9$ spermatozoa in 100ml extender, respectively. There were no significant differences on reproductive performances such as gestation period, total born, total born alive, stillbirth and mummy in sows inseminated with different semen doses. The average number of born alive was 10.5, 11.0 and 10.4 from sows inseminated with $1.5{\times}10^9$, $2.0{\times}10^9$ and $2.5{\times}10^9$ sperms, respectively. Also, number of spermatozoa per dose did not affect litter size (p>0.10). There were no significant differences of maternal genetic line difference on gestation period, total number born, number born alive, born dead and mummy. The estimated correlation coefficients of the different semen doses with total number born, number born alive, born dead and mummy were r=-0.00, -0.01, 0.02 and 0.02, respectively. Taken together, the result of this study suggested that when semen was appropriately inseminated after induced ovulation, insemination with low-dose ($1.5{\sim}2.0{\times}10^9$) semen dose not adversely affect sow's fertility.