• 제목/요약/키워드: Average Pressure

검색결과 2,015건 처리시간 0.03초

Plate and Shell 열교환기내의 R-22 응축압력강하 특성에 관한 실험적 연구 (An Experimental Study on Pressure drop Characteristics in Plate and Shell Heat Exchanger)

  • 이기백;서무교;박재홍;김영수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권6호
    • /
    • pp.1220-1227
    • /
    • 2001
  • The condensation pressure drop fur refrigerant R-22 flowing in the plate and shell heat exchanger were investigated experimentally in this study. Two vertical counterflow channels were formed in the exchanger by three plates of commercial geometry with a corrugated trapezoid shape of a chevron angel of $45^{\circ}$. The condensing R-22 flowing down in one channel exchanges heat with the cold water flowing up in the other channel. The effects of the mean vapor quality, mass flux, average imposed heat flux and system pressure of R-22 on the pressure drop were explored in detail. The quality change of R-22 between the inlet and outlet of the refrigerant channel ranges from 0.03 to 0.05. The present data showed that pressure drop increases with the vapor quality. At a higher mass flux, pressure drop is higher for the entire range of the vapor quality. Also, a rise in the average imposed heat flux causes an slight increase in the Pressure drop. Finally, at a higher system pressure the pressure drop is found to be slightly lower. Correlation is also provided for the measured pressure drops in terms of the friction factor.

  • PDF

습식 부항 시술시 사혈량에 따른 부항 탈락 위험도 탐색 (Change in Risk of Dropout Due to Bleeding during Bloodletting-Cupping Therapy)

  • 김대혁;배은경;박정환;김소영;이상훈
    • Korean Journal of Acupuncture
    • /
    • 제35권1호
    • /
    • pp.41-45
    • /
    • 2018
  • Objectives : To investigate minimum pressure by verifying changes in pressure due to bleeding amount during bloodletting-cupping therapy. Methods : (1) We compared adhesion performance of four different cupping cups of same size: two disposable cupping cups(A, B) and two reusable cupping cups(A, B) each were vacuumed three times and kept in place for 10 minutes. (2) We vacuumed two different sized disposable cupping cups(A), size.1(InnerDiameter 48.8 mm) and size.3(InnerDiameter 39.1 mm), twice each(-200 mmHg) on silicon plate. We injected water and air at regular intervals in cupping cups by using a syringe, and then measured change of pressure in cupping cups and pressure at the time of dropout. Results : (1) Pressure reduction was $4.75{\pm}2.78%$ on average in the order of 'Disposable[A]>reusable[B]>Disposable[B]>reusable[A]', so that pressure retention performance of disposable cups can't be regarded as inferior to that of reusable cups. (2) Pressure of disposable cupping B(size.1) decreased by an average of -40.08 mmHg per 5 ml of water. At -24.8 mmHg, when 22 ml of water has been injected, cup has come off. Pressure of disposable cupping B(size. 3) decreased by an average of -99.4 mmHg per 5 ml of water. At -48.6 mmHg, when 13 ml of water was injected, cupping came off. Conclusions : Considering reduction rate of pressure due to water injection, in case of bleeding more than 15 ml, size.3 cup always comes off, therefore it needs to be re-operated at least once. Meanwhile, size.1 cup does not always come off in the same condition, depending on the initial pressure and therefore, re-operation may be considered.

경운토양의 물리적 특성변화를 고려한 Green And Ampt 매개변수의 추정 (Green and Ampt Parameter Estimation Considering Temporal Variation of Physical Properties on Tilled Soil)

  • 정하우;김성준
    • 한국농공학회지
    • /
    • 제33권2호
    • /
    • pp.120-129
    • /
    • 1991
  • This study refers to temporal variation of physical properties of tilled soil under natural rainfalls. Field measurements of porosity, average hydraulic conductivity and average capillary pressure head on a tilled soil were conducted by soil sampler and air-entry permeameter respectively at regular intervals after tillage. Temporal variation of these physical properties were analysed by cumulative rainfall energy since tillage. Field experiment was conducted on a sandy loam soil at Suwon durging April~July in 1989. The followings are a summary of this study results ; 1. Average porosity just after tillage was 0.548cm$^3$/cm$^3$. As cumulative rainfall energy were increased in 0.1070, 0.1755, 0.3849 J/cm$^2$, average porosity were decreased in 0.506, 0.4]95, 0.468m$^3$/cm$^3$ respectively. 2. Average hydraulic conductivity just after tillage was 45.42cm/hr. As cumulative rainfall energy were increased in 0.1755, 0.2466, 0.2978, 0.3849J/cm$^2$ average hydraulic conductivity were decreased in 15.34, 13.47, 9.58, 8.65cm/hr respectively. 3. As average porosity were decreased in 0.548, 0.506, 0.495, 0.468cm$^3$/cm$^3$ average capillary pressure head were increased in 6.1, 6.7, 6.9, 7.4cm respectively. 4. It was found that temporal variation of porosity, average hydraulic conductivity on a tilled soil might be expressed as a function of cumulative rainfall energy and average capillary pressure head might be expressed as a function of porosity. 5. The results of this study may be helpful to predict infiltration into a tilled soil more accurately by considering Temporal variation of physical properties of soil.

  • PDF

통계적 기법을 이용한 배·급수 관망 내 감압 밸브 성능 평가에 관한 사례 연구 (Evaluation of Pressure Reducing Valves performance using Statistical Approach in Water Distribution System : Case Study)

  • 박노석;최두용;이영주;윤석민
    • 상하수도학회지
    • /
    • 제29권4호
    • /
    • pp.519-531
    • /
    • 2015
  • It has been widely accepted that the pressure management of water distribution systems using pressure reducing valves(PRVs) would be an effective method for controlling leakages. A pressure reducing valve (PRV) regulates outlet pressure regardless of fluctuating flow and varying inlet pressure, thereby reducing leakage and mitigating the stress on the water distribution system. However, the operation of a PRV is vulnerable to its mechanical condition and hydraulic operability. In this research, the effect of PRVs installed in water distribution system are evaluated in terms of hydraulic pressure reduction and mechanical performance by analyzing measured pressure data with statistical approach. A statistical approach using the moving average filter and frequency analysis based on fourier transform is presented to detect abnormally operated PRVs that have been densely installed in water distribution system. The result shows that the proposed approach can be a good performance evaluation method by simply measuring pressures for the PRVs.

가스응축장치 캐리어가스 공급속도 및 압력변화를 통한 비스무스 나노분말 입도제어 (Size Control of Bismuth Nanoparticles by Changes in Carrier-Gas Flow Rate and Chamber Pressure of Gas Condensation Apparatus)

  • 이경자;김창규;이민구;이창규
    • 한국분말재료학회지
    • /
    • 제17권5호
    • /
    • pp.379-384
    • /
    • 2010
  • In the present work, bismuth nanopowders with various particle size distributions were synthesized by controlling argon (Ar) gas flow rate and chamber pressure of a gas condensation (GC) apparatus. From the analyses of transmission electron microscopy (TEM) images and nitrogen gas adsorption results, it was found that as Ar gas flow rate increased, the specific surface area of bismuth increased and the average particles size decreased. On the other hand, as the chamber pressure increased, the specific surface area of bismuth decreased and the average particles size increased. The optimum gas flow rate and chamber pressure for the maximized electrochemical active surface area were determined to be 8 L/min and 50 torr, respectively. The bismuth nanopowders synthesized at the above condition exhibit 13.47 $m^2g^{-1}$ of specific surface area and 45.6 nm of average particles diameter.

거리에 따른 수직 충돌 제트의 표면 평균압 측정 (Measurement of the Average Surface Pressure by a Vertical Impinging Jet for the Different Distances)

  • 정우원;이계한;장안식;박경열;전경진
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.181-182
    • /
    • 2006
  • When a water jet is injected on the body surface, the pressure and shear stress on the surface are important physical parameters in determining the body surface wash out and physical stimulus. We used the force plate in order to measure the surface average pressure for different nozzle types and distances between a nozzle and a plate. We used the nozzles with a hole dimeter of 1.8, 2.9, 3.2mm, and the shower heads with 10 holes (hole diameter, 1mm) and 20 holes (hole diameter, 1mm). The distances between a nozzle and a plate was 10, 20, 30, 40cm. The results showed that the surface forces were not affected by the distances between a nozzle and a plate. Further numerical studies will be performed to predict wall shear stress based on the measured pressure data.

  • PDF

Dynamic failure features and brittleness evaluation of coal under different confining pressure

  • Liu, Xiaohui;Zheng, Yu;Hao, Qijun;Zhao, Rui;Xue, Yang;Zhang, Zhaopeng
    • Geomechanics and Engineering
    • /
    • 제30권5호
    • /
    • pp.401-411
    • /
    • 2022
  • To obtain the dynamic mechanical properties, fracture modes, energy and brittleness characteristics of Furong Baijiao coal rock, the dynamic impact compression tests under 0, 4, 8 and 12 MPa confining pressure were carried out using the split Hopkinson pressure bar. The results show that failure mode of coal rock in uniaxial state is axial splitting failure, while it is mainly compression-shear failure with tensile failure in triaxial state. With strain rate and confining pressure increasing, compressive strength and peak strain increase, average fragmentation increases and fractal dimension decreases. Based on energy dissipation theory, the dissipated energy density of coal rock increases gradually with growing confining pressure, but it has little correlation with strain rate. Considering progressive destruction process of coal rock, damage variable was defined as the ratio of dissipated energy density to total absorbed energy density. The maximum damage rate was obtained by deriving damage variable to reflect its maximum failure severity, then a brittleness index BD was established based on the maximum damage rate. BD value declined gradually as confining pressure and strain rate increase, indicating the decrease of brittleness and destruction degree. When confining pressure rises to 12 MPa, brittleness index and average fragmentation gradually stabilize, which shows confining pressure growing cannot cause continuous damage. Finally, integrating dynamic deformation and destruction process of coal rock and according to its final failure characteristics under different confining pressures, BD value is used to classify the brittleness into four grades.

일 중소도시 중학생의 비만과 총콜레스테롤, 혈당, 혈압간의 관계 (The Relation between Obesity among Middle School Students and Total Cholesterol, Blood Glucose and Blood Pressure)

  • 김은영
    • 한국보건간호학회지
    • /
    • 제19권1호
    • /
    • pp.5-17
    • /
    • 2005
  • This research was conducted to determine the actual condition of obesity and obese students' total cholesterol. blood glucose and blood pressure, and to analyze the relationship between the obesity rate and total cholesterol. blood glucose and blood pressure among the students at 7 middle schools in A city in Kyoung ki-do. The results were as follows: 1. Among 12,148 student participants in this investigation. students of normal weight range were $91.5\%$ and obese students were $8.5\%$, breaking down to mildly obese of $4.3\%$ $(boys,\;5.4\%;\;girls,\;3.0\%)$. moderately obese of $3.4\% (boys,\;4.6\%;\;girls,\;2.1\%)$ and severely obese of $0.7\%(boys,\;0.9\%;\;girls,\;0.5\%)$, The gender difference was statistically significant $(x^2=111.5830. p=.0001). 2. To analyze the 1.027 obese students. the average of total cholesterol was 166.9mg/dl, 171.0mg/dl and 182.1mg/dl in the mild, moderate and severe obesity groups, respectively. The results became more significant with increasing obesity rate (F=10.06, p=.0001). The average of systolic blood pressure (SBP) was 121.9mmHg, 123.2mm, and 127.5mm, respectively. The results became more significant with increasing obesity rate (F=6.29, p=.0019). The average of diastolic blood pressure (DBP) was 74.4mmHg. 76.0mmHg. and 78.4mmHg, respectively. The results became more significant with increasing obesity rate (F=8.15. p=.0003). The average of blood glucose was 83.3mg/dl, 84.5mg/dl, and 82.3mg/dl, respectively. There was no significant difference with obesity rate. 3. There were significant correlations between obesity rate and cholesterol(r=.11288, p=.0003), between obesity rate and DBP(r=.14209, p=.000l). and between obesity rate and SBP(r=.14081. p=.0001). However, there was no significant correlation between obesity rate and blood glucose (r=.00655, p=.8339).

  • PDF

Analysis of the Plantar Pressure on the Flat and Slope Walking by Insole Type

  • Kim, Bu Gan;Lee, Joong Sook;Yang, Jeong Ok;Lee, Bom Jin
    • 한국운동역학회지
    • /
    • 제28권3호
    • /
    • pp.165-173
    • /
    • 2018
  • Objective: The purpose of this study is to provide biomechanical basis data for the analysis of the maximum vertical ground reaction force, the maximum plantar pressure, the average plantar pressure, and the contact area according to the type of the insole through the insole insertion type foot pressure gauge. Method: In the treadmill, the slope was set at 10%, the first type A was worn at a walking speed of 3.5 km / h, and then walking was carried out using B, C, and D types. Data from 20 boots with consistent walking were extracted and plantar pressure data were collected and analyzed. Results: Functional insole was more effective than conventional insole for maximum vertical ground reaction force, maximum plantar pressure, average plantar pressure, and contact area at 10% of treadmill ramps. Conclusion: In this study, D-type insole supports the cushion in the middle part and supports the heel cup with hardness in the hind part, so that it is the most effective insole by lowering the plantar pressure and dispersing it more widely.

판각형 열교환기 내의 R-22 증발 압력강하 특성에 관한 실험적 연구

  • 서무교;박재홍;김영수
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.930-938
    • /
    • 2001
  • In this study, evaporation pressure drop experiments were conducted with two types of plate and shell heat exchangers (P&SHE) using R-22. An experimental refrigerant loop has been established to measure the evaporation pressure drop of R-22 in a vertical P&SHE. The flow channels were formed by adding three plates having a corrugated channel of a chevron angle of $45^{\circ}$. The R-22 flows down in one channel exchanging heat with the hot water flowing up in the other channel. The effect of the refrigerant mass flux, average heat flux, system pressure and vapor quality were explored in detail. During the experiment, the quality change between the inlet and outlet of the refrigerant channel ranges from 0.03 to 0.15. The present data showed that two types of P&SHE have similar trends. The pressure drop increases with the vapor quality for both types of P&SHE. At a higher mass flux, the pressure drop is higher for the entire range of the vapor quality. Also, the increase in the average heat flux increases the pressure drop. Finally, at a higher system pressure, the pressure drop is found to be slightly lower.

  • PDF