• 제목/요약/키워드: Average Load

검색결과 1,453건 처리시간 0.031초

Nail Withdrawal Behavior for Domestic Small Diameter Logs

  • Cha, Jae-Kyung
    • Journal of the Korean Wood Science and Technology
    • /
    • 제30권3호
    • /
    • pp.104-108
    • /
    • 2002
  • Nail withdrawal tests were conducted on clear wood of domestic small diameter logs. Nails were driven into the cross and longitudinal sections of each specimen, then nail withdrawal tests were performed. Nail withdrawal loads are strongly dependent on the direction of nail positions. The average load values for the nail withdrawal both in cross section and longitudinal section are higher in high specific gravity (SG) wood of sawtooth oak (Quercus acutissima Carr.) than those in low SG wood of Korean red pine (Pinus densiflora Sieb. et Zucc.) and pitch pine (Pinus rigida Mill.). The average ratio of the nail withdrawal loads for side-grain and end-grain are higher in the low SG wood than that in the high SG of wood. Both linear and non-linear regression analyses were conducted on nail withdrawal load with SG, good correlations were obtained between nail withdrawal load and SG.

냉방과 난방 부하 감소를 위한 지하피트의 이용 가능성 (The Possibility on Utilization of Underground Pit for Reduction of Cooling and Heating Load)

  • 조성우
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.144-150
    • /
    • 2006
  • The purpose of this study is to predict outlet temperature and humidity through underground pit for the reduction of cooling load and heating load. Commonly, the underground temperature is lower than outdoor in summer but the reverse happens in winter. When the outdoor average air temperature is $25.7^{\circ}C$ during cooling periods, the average outlet air temperature through underground pit is $23.6^{\circ}C$ with 3 m-depth and 60m-length and is $22.2^{\circ}C$ with 3 m-depth and 150 m-length. When the outdoor average air temperature is $4.9^{\circ}C$ during heating periods, the average outlet air temperature through underground pit is $7.7^{\circ}C$ with 3m-depth and 60 m-length and is $10.8^{\circ}C$ with 3 m-depth and 150 m-length. The outlet air temperature is affected by more length than depth of underground pit. The diffusion ratio of outdoor humidity is $-7.7\times10^{-8}kg/s$ in cooling periods and $9.29\times10^{-7}kg/s$ in heating periods.

Influence of Earlywood, Latewood, and Nail Driving Position on Nail Withdrawal Load Behavior

  • Cha, Jae-Kyung
    • Journal of the Korean Wood Science and Technology
    • /
    • 제26권2호
    • /
    • pp.1-5
    • /
    • 1998
  • Nail withdrawal tests were conducted on clear wood of radiata pine. Nails were driven into the earlywood and latewood zones of each specimen, and nail withdrawal tests were then performed. Nail withdrawal loads were strongly dependent on earlywood and latewood and on nail position. The average load values for nail withdrawal in both the tangential and longitudinal directions were higher for latewood than for earlywood. Linear and nonlinear regression analyses of nail withdrawal load with specific gravity showed no discernible differences. Good correlations were obtained between nail withdrawal load and specific gravity.

  • PDF

불규칙 하중을 받는 자전거 브레이크의 피로 해석 (Fatigue Analysis of Bike Brake under Nonuniform Load)

  • 조재웅;한문식
    • 한국자동차공학회논문집
    • /
    • 제20권4호
    • /
    • pp.133-141
    • /
    • 2012
  • This study investigates structural and fatigue analyses of bike brake. Maximum equivalent stress of the model of mountain bike is 4 times as much as the model of general bike at static analysis. In cases of mountain and general bikes, maximum damage frequency at load of 'SAE bracket history' with the severest change of load becomes as much as 16 times than the most stable load of 'Sample history' among the nonuniform fatigue loads. In case of mountain bike, the possibility of maximum damage becomes 3% at the load of 'Sample history' with the average stress of 0 to $-3{\times}10^4$MPa and the amplitude stress of 0 to $10^4$MPa. In case of general bike, the possibility of maximum damage becomes 3% at the load of 'Sample history' with the average stress of 0 to $-0.8{\times}10^4$MPa and the amplitude stress of 0 to $0.2{\times}10^4$MPa. This stress state can be shown as 5 to 6 times more than the damage possibility of 'SAE bracket history' or 'SAE transmission'. The analysis result of this study can be effectively utilized for the safe design of bike brake.

ARIMA 모형에 기초한 수요실적자료 보정기법 개발 (A Correction Technique of Missing Load Data Based on ARIMA Model)

  • 박종배;이찬주;이재용;신중린;이창호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권7호
    • /
    • pp.405-413
    • /
    • 2004
  • Traditionally, electrical power systems had the vertically-integrated industry structures based on the economics of scale. However power systems have been recently reformed to increase the energy efficiency of the power system. According to these trends, Korean power industry has been partially restructured, and the competitive generation market was opened in 2001. In competitive electric markets, correct demand data are one of the most important issue to maintain the flexible electric markets as well as the reliable power systems. However, the measuring load data can have the uncertainty because of mechanical trouble, communication jamming, and other things. To obtain the reliable load data, an efficient evaluation technique to adust the missing load data is needed. This paper analyzes the load pattern of historical real data and then the turned ARIMA (Autoregressive Integrated Moving Average) model, PCHIP(Piecewise Cubic Interporation) and Branch & Bound method are applied to seek the missing parameters. The proposed method is tested under a variety of conditions and tested with historical measured data from the Korea Energy Management Corporation (KEMCO).

Dynamic behaviors of viscous damper on concrete archaized building with lintel-column joint

  • Xue, Jianyang;Dong, Jinshuang;Sui, Yan
    • Earthquakes and Structures
    • /
    • 제13권4호
    • /
    • pp.409-419
    • /
    • 2017
  • In order to analyze the vibration control effect of viscous damper in the concrete archaized buildings with lintel-column joints under seismic action, 3 specimens were tested under dynamic excitation. Two specimens with viscous damper were defined as the controlled component and one specimen without viscous damper was specified as the non-controlled component. The loading process and failure patterns were obtained from the test results. The failure characteristics, skeleton curves and mechanical behavior such as the load-displacement hysteretic loops, load carrying capacity, degradation of strength and rigidity, ductility and energy dissipation of the joints were analyzed. The results indicate that the load-bearing capacity of the controlled component is significantly higher than that of the non-controlled component. The former component has an average increase of 27.4% in yield load and 22.4% in ultimate load, respectively. Meanwhile, the performance of displacement ductility and the ability of energy dissipation for the controlled component are superior to those of the non-controlled component as well. Compared with non-controlled component, equivalent viscous damping coefficients are improved by 27.3%-30.8%, the average increase is 29.0% at ultimate load for controlled component. All these results reflect that the seismic performance of the controlled component is significantly better than that of the non-controlled component. These researches are helpful for practical application of viscous damper in the concrete archaizing buildings with lintel-column joints.

보재의 손상에 따른 비계용 작업발판의 강성 변화에 대한 실험적 연구 (An Experimental Study on the Stiffness Change of Scaffold Working Plate caused by Damage of Cross-beam)

  • 성용원;강민국;원정훈
    • 한국안전학회지
    • /
    • 제36권5호
    • /
    • pp.27-35
    • /
    • 2021
  • This study investigated the change in stiffness and deflection of a scaffold working plate caused by damage to a cross-beam in the plate. Experiments were conducted considering various load and damage conditions of cross-beams. A cross-beam falling off from the working plate was considered damaged. The load-displacement curves of specimens at the center of the uniform load showed that the working plate stiffness decreased by 14.66%-1.89%, depending on the load interval due to the damage of one cross-beam. A reduction in the stiffness of 33.94%-40.76% resulted from the damage of two cross-beams. Moreover, the displacement increased by an average of 25% when one cross-beam was damaged and an average of 65% when two cross-beams were damaged. Therefore, damage to the cross-beam in the working plate can potentially cause accidents and harm workers. As the load increases, the risk of an accident due to the aforementioned damage also increases because the stiffness remarkably decreases with the load increase. Further, the damage to the cross-beam mainly reduces the stiffness but increases the displacement rather than the strength of the working scaffold plate.

맥동 전압 추출을 통한 배전용 정지형 보상기의 직류링크 전압제어 (DC-Link Voltage Control of Distribution Static Compensator using Ripple Voltage Extraction)

  • 김호열;최종우
    • 전력전자학회논문지
    • /
    • 제17권1호
    • /
    • pp.8-13
    • /
    • 2012
  • DSTATCOM is active filter that reduces nonlinear and unbalanced currents. Researches about DSTATCOM are mainly divided two parts, one is the reference value calculation of compensation current depending on the calculation of the load-side average active power and dc-link capacitor average voltage, the other part is actual current control depending on the reference value of compensation current. This paper proposes a calculation of dc-link capacitor average voltage ripple voltage extraction instead of conventional method using LPF. The utility of the proposed algorithm is verified through the theoretical analysis and the experiment under unbalance loads and non-linear load.

DLP방식의 치과용 3D프린팅 임시치아 소재의 기계적 특성 (Mechanical Properties of DLP-type Dental 3D Printing Temporary Tooth Material)

  • 정효경;이승희;정효경
    • 한국산업융합학회 논문집
    • /
    • 제24권3호
    • /
    • pp.373-376
    • /
    • 2021
  • Tested the flexural strength and maximum load of two types of dental 3 D printed temporary tooth materials of the DLP method. The average flexural strength was 206.98 MPa in the test group and 139.77 MPa in the control group. The average flexural strength of the experimental group was 67.21 MPa higher than that of the control group. In the maximum load experiment, an average of 44.16N in the experimental group and 37.31N in the control group were measured. The average value of 6.85N was higher in the experimental group, and the durability of the artificial tooth restoration was improved.

자동검침 고객의 부하패턴을 이용한 일일 대표 부하패턴 생성 (Typical Daily Load Profile Generation using Load Profile of Automatic Meter Reading Customer)

  • 김영일;신진호;이봉재;양일권
    • 전기학회논문지
    • /
    • 제57권9호
    • /
    • pp.1516-1521
    • /
    • 2008
  • Recently, distribution load analysis using AMR (Automatic Meter Reading) data is researched in electric utilities. Load analysis method based on AMR system generates the typical load profile using load data of AMR customers, estimates the load profile of non-AMR customers, and analyzes the peak load and load profile of the distribution circuits and sectors per every 15 minutes/hour/day/week/month. Typical load profile is generated by the algorithm calculating the average amount of power consumption of each groups having similar load patterns. Traditional customer clustering mechanism uses only contract type code as a key. This mechanism has low accuracy because many customers having same contract code have different load patterns. In this research, We propose a customer clustring mechanism using k-means algorithm with contract type code and AMR data.