• Title/Summary/Keyword: Average Illumination

Search Result 201, Processing Time 0.022 seconds

The Study on Envronmental Sanitation for Night High School. -Illuminate- (야간 고등학교의 환경위생학적 조사 -조명을 중심으로-)

  • 김난천;오석흔
    • Journal of Environmental Health Sciences
    • /
    • v.5 no.1
    • /
    • pp.40-45
    • /
    • 1978
  • We have selected 36 schools of a total of night high schools for boys and girls in seoul and measured intensity of illumination of the classroom, The corridors and the stairs that students study and live, with priority given to an illumination, a primary factor of environmental sanitation of school following is the result. 1. The maximum average intensity of illumination of the classroom is 93.2 Lux, and the minimum average intensity of illumination 39.5 Lux. Mean$\pm$S, is 59.03$\pm$22.8 Lux 2. The maximum average intensity of illumination of the corridor is 39.2 Lux, and the minimum average intensity of illumination 11.1 Lux. 3. The maximum average intensity of illumination of the stair is 11.58 Lux, and the minimum average intensity, of illumination 4.92 Lux, mean$\pm$S.D is 7.88$\pm$10.0Lux. 4. Schools with tile illumination facilities more than 50 Lux are 63.8% and less than 50 Lux are 36.2%. 5. Schools with 9-11 facilities of a source of light per classroom by a fluorescent lamp are the most as 30.50%. 6. As for the corridor, schools with the illumination equipment less than 10 Lux are 27.8%, are more than 10 Lux 72.2% 7. As for the stairs schools with the illumination equipment less than 10 Lux are 77.8%, and more than 10 Lux 10 Lux 22.2%.

  • PDF

Characteristics of th Distribution of Night Illumination Level at Urban Neighborhood Parks (도시근린공원의 야간조도분포의 특성)

  • 최연철;김진선
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.28 no.4
    • /
    • pp.66-74
    • /
    • 2000
  • The purpose of this study is to research and analyze the distribution of night illumination level at urban neighborhood parks and to show its characteristics. And this is used basic data ensuring safety and satisfying aesthetic and psychological desires of people who use urban neighborhood parks at night. To research and analyze the distribution of illumination level at urban neighborhood parks at night. To research and analyze the distribution of illumination level at urban neighborhood parks, I selected 8 urban neighborhood parks as the subject of research in this study, set the measuring standard of illumination level, and measured the illumination level by the measuring standard. The results of this study are as follows; 1. Currently, total average illumination level of urban neighborhood parks was lower than the minimum standard of illumination level I KS A 3011-1993. 2. Average illumination level of each place in urban neighborhood parks appeared variously from low level to high level. But this was lower than the minimum standard illumination level in KS A3011-1993 like total average illumination level. 3. The higher was total average illumination level of urban neighborhood parks, the more various was brightness of places. Although users' aesthetic and mental desire or behavioral aspect relate with safety cannot be found by only survey and analyses of illumination level, it is judged that first, illumination level of the standard of the lightness should be analyzed to find user's mental states and behaviors in external space at night. Therefore, it is considered that this study, which analyzed characteristics illumination level as basic data, has a significance. The study continuing for other illuminative environmental factors suitable in the place is required because the brightness of places may not be measured by only illumination level. And the proper illumination level in outdoor places should be showed in considering psychological and behavioral aspects of human as people may have their own sense of brightness.

  • PDF

Actual Conditions on the Illumination Environment of the Study Rooms in the Youth of an Agriculture Village (농촌 청소년 공부방의 조명환경 실태조사)

  • Kim, Hyun-Ji;Jun, Kyoung-Sun;Lee, In-Hyo;An, Ok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.4
    • /
    • pp.1-7
    • /
    • 2009
  • This study investigated the actual conditions of the illumination environment from agricultural youth study room. The result, average space of the study room was 11.42[$m^2$]. The illuminant uses the fluorescent lamp mainly, Method of using illumination was only general illumination the case which uses 73.8[%]. Method of light distribution was a direct lighting mainly. The house which has a stand illumination was also 45.7[%], The percentage using the stand illumination which was a local illumination was nothing but in 20[%] of the whole subject of investigation, therefore eye work could not effective. The internal illuminance was average 131.82[lx], the desk illuminance was 253.64[lx] which was the minimum permitted limit and poor. Uniformity ratio of illuminance appeared with average 35.61[%]. The satisfaction with 3.93 points to be high for illumination environment, therefore it was thought that the recognition of illumination was very insufficient.

A STUDY ON THE ILLUMINATION OF DENTAL CLINIC (치과 진료실의 조명에 관한 실태 조사연구)

  • Choi Jong-In;Kim Yu-Lee;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.374-382
    • /
    • 2006
  • Purpose: This study was designed to investigate the present conditions of illumination techniques in dental clinics in order to contribute improvement of operating environment. This study also aimed exploring qualitative and quantitative luminous intensity required for color temperature in dental clinic illumination, which was a critical part of esthetic dentistry. Materials and methods: A total of forty-eight local dental clinics were selected for sampling a) luminous intensity, and b) color temperature. The author measured the luminous intensity and the color temperature with lux meter and color meter respectively between 12pm and 2pm. The dental unit chair placed in the general operation positions were kept the distance 60 cm then all dental units were measured three times and averaged. The author measured the luminous intensity and color temperature with both common dental operating light and then without operating light in different office environments. The study was conducted under three conditions: 1 artificial illumination in clear day light 2. artificial illumination in cloudy day light, and 3. artificial illumination alone. Results : The results obtained were as follows. 1. The average luminous intensity in dental clinic lighting was 425 lux which was not sufficient to produce the optimal shade of the patient's teeth. Furthermore, the average luminous intensity even in full operating lighting was 9532 lux which fell short of the required level of 10,000 lux. 2. The average color temperature of all dental clinics surveyed was 5169 K which met the optimal range. However, only 33.3% fell in the correct region between 5,000-5,500 K as 25% were over 5,500 K and 41.6% were below 5,000 K. As a result, 66.7% were under insufficient color temperature conditions. 3. The dental unit chair placed next to a window, hence exposure to natural lighting, had significantly higher luminous intensity and color temperature compared to the dental unit chair which didn't have a window or natural lighting. 4. The data analysis revealed that only 6.3% of the dental clinic were met the standard of the average luminous intensity and color temperature.

The design and the analysis of a LED illumination lens using the overlapped model (중첩모델을 이용한 조명용 LED 렌즈설계 및 분석)

  • You, Ilhyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.1
    • /
    • pp.157-164
    • /
    • 2017
  • In this research, the overlapped illumination model was used for designing a freeform LED lens with a uniform illuminance distribution on its illuminating plane, and their performances and tolerances were compared. And, the illuminations on a illumination plane was measures for change with average illuminance and illuminance uniformity. As a result of the tolerance analysis about z-axis direction change, thickness change in lens and tilt change of light emission and characteristic change in LED source, overlapped model and divergent illumination model are similar to the performance about Z-axis direction change of light emission in LED source. but the uniformity illumination value in this overlapped model is more remarkably value than it in divergent illumination model about thickness change in LED lens. Also, even though the lens based on a divergent illumination model showed good performance compare to the lens based on an overlapped illumination model, the latter was less the deviation to variation of LED beam radiation ability.

A Study on the Status of Illumination Environment in Workplaces (업무공간의 조명 환경 실태 조사 연구)

  • Choi Han-Hee;Ha Mi-Kyoung
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.6
    • /
    • pp.167-174
    • /
    • 2004
  • The purpose of this study is to examinethe present illumination conditions in office environment and to suggest an efficient illumination plan in office planning process. Illumination conditions in work environment were surveyed in 6 offices to investigate whether the present illumination conditions were appropriate to the work type. The results of this study are as follows: Most of the general Illuminance level in the area of work were all at an adequate level, except one. The average Illuminance level in the all meeting rooms were met for the standard. Illuminance in the all reception area were extremely over the standard, The illuminations of this area were rather designed according to the image of the company than the standard. As for the illumination method in the area of general work, four offices used a general lighting by a direct lighting type, while two offices used a general lighting and a task lighting at the same time. This survey suggested that first, each company should consider illumination plan in the building planning process, second, illumination plan considering the type of places is needed, and third, illumination environment may be differentiated according to the work type. In conclusion, efficient illumination environment should be considered in office building planning process, especially In terms of illumination materials and methods.

A Study on the Illumination Environment in Show Window (쇼윈도 조명환경에 관한)

  • 김현지;안옥거
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1993.10a
    • /
    • pp.32-37
    • /
    • 1993
  • This study investigates the relationship between size, illumination ,and display of show window. The average width, heigh, and depth of show windows in Taegu area were 341.3, 233.4, and 125.8cm, respectively. As light source, halogen lamp was most frequently used, followed by fluorescent lamp and incandescence lamp. In the actual illumination, however, a combined use of more than 2 light sources was common. Further, a local illumination method, e.g., spot light, was generally adopted. The thought of employers and employees in fashion shops about display and illumination was examined aw well. On the whole, the necessity and importance of display were well recognized but the fact that the illumination should be hamonized with other factors such as color and arrangement of goods was underestimated.

  • PDF

Illumination Estimation Based on Nonnegative Matrix Factorization with Dominant Chromaticity Analysis (주색도 분석을 적용한 비음수 행렬 분해 기반의 광원 추정)

  • Lee, Ji-Heon;Kim, Dae-Chul;Ha, Yeong-Ho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.8
    • /
    • pp.89-96
    • /
    • 2015
  • Human visual system has chromatic adaptation to determine the color of an object regardless of illumination, whereas digital camera records illumination and reflectance together, giving the color appearance of the scene varied under different illumination. NMFsc(nonnegative matrix factorization with sparseness constraint) was recently introduced to estimate original object color by using sparseness constraint. In NMFsc, low sparseness constraint is used to estimate illumination and high sparseness constraint is used to estimate reflectance. However, NMFsc has an illumination estimation error for images with large uniform area, which is considered as dominant chromaticity. To overcome the defects of NMFsc, illumination estimation via nonnegative matrix factorization with dominant chromaticity image is proposed. First, image is converted to chromaticity color space and analyzed by chromaticity histogram. Chromaticity histogram segments the original image into similar chromaticity images. A segmented region with the lowest standard deviation is determined as dominant chromaticity region. Next, dominant chromaticity is removed in the original image. Then, illumination estimation using nonnegative matrix factorization is performed on the image without dominant chromaticity. To evaluate the proposed method, experimental results are analyzed by average angular error in the real world dataset and it has shown that the proposed method with 5.5 average angular error achieve better illuminant estimation over the previous method with 5.7 average angular error.

A Study on the development of climatic data for the daylighting design (자연채광 설계용 기상자료의 개발에 관한 연구)

  • Yang, In-Ho;Kim, Kwang-Woo;Kim, Mun-Han
    • Solar Energy
    • /
    • v.11 no.1
    • /
    • pp.3-15
    • /
    • 1991
  • In this study global radiation and global illumination are directly measured and diffuse radiation and diffuse illumination measured utilizing semi-circular shadow ring. By analyzing measured radiation data, clear and overcast sky are classified according to the sky classification method used in Mantes, France. Measured illumination data are analyzed and 1) Clear sky illumination on a horizontal surface as a function of solar altitude. 2) Overcast sky illumination on a horizontal surface as a function of solar altitude, 3) Monthly variation of illumination. 4) Cumulative percentage of illumination, 5) Daylight intensity as a function of hours in a typical day, 6) Average number hours per day of illumination above 10 and 20klx are presented as a climatic data for daylighting design for Seoul, Korea.

  • PDF

Calculation of Illuminance Using Fuzzy Reasoning and Zonal Cavity Method (퍼지 추론과 구역 공간법을 이용한 조도 계산법)

  • 최홍규;강태은;원진희;조용상
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.240-246
    • /
    • 1999
  • This parer proposes fuzzy reasoning algorithm for improvement in Zonal Cavity Method that is difficult to calculate average illumination without lighting scope and reflection factor so on. This parer use fuzzy reasoning algorithm for maintainment of the best illumination in spite of some variation those are influenced of room illumination and cut down the difficult to be calculated used Zonal Cavity Method.

  • PDF