• 제목/요약/키워드: Average Illumination

검색결과 201건 처리시간 0.027초

야간 고등학교의 환경위생학적 조사 -조명을 중심으로- (The Study on Envronmental Sanitation for Night High School. -Illuminate-)

  • 김난천;오석흔
    • 한국환경보건학회지
    • /
    • 제5권1호
    • /
    • pp.40-45
    • /
    • 1978
  • We have selected 36 schools of a total of night high schools for boys and girls in seoul and measured intensity of illumination of the classroom, The corridors and the stairs that students study and live, with priority given to an illumination, a primary factor of environmental sanitation of school following is the result. 1. The maximum average intensity of illumination of the classroom is 93.2 Lux, and the minimum average intensity of illumination 39.5 Lux. Mean$\pm$S, is 59.03$\pm$22.8 Lux 2. The maximum average intensity of illumination of the corridor is 39.2 Lux, and the minimum average intensity of illumination 11.1 Lux. 3. The maximum average intensity of illumination of the stair is 11.58 Lux, and the minimum average intensity, of illumination 4.92 Lux, mean$\pm$S.D is 7.88$\pm$10.0Lux. 4. Schools with tile illumination facilities more than 50 Lux are 63.8% and less than 50 Lux are 36.2%. 5. Schools with 9-11 facilities of a source of light per classroom by a fluorescent lamp are the most as 30.50%. 6. As for the corridor, schools with the illumination equipment less than 10 Lux are 27.8%, are more than 10 Lux 72.2% 7. As for the stairs schools with the illumination equipment less than 10 Lux are 77.8%, and more than 10 Lux 10 Lux 22.2%.

  • PDF

도시근린공원의 야간조도분포의 특성 (Characteristics of th Distribution of Night Illumination Level at Urban Neighborhood Parks)

  • 최연철;김진선
    • 한국조경학회지
    • /
    • 제28권4호
    • /
    • pp.66-74
    • /
    • 2000
  • The purpose of this study is to research and analyze the distribution of night illumination level at urban neighborhood parks and to show its characteristics. And this is used basic data ensuring safety and satisfying aesthetic and psychological desires of people who use urban neighborhood parks at night. To research and analyze the distribution of illumination level at urban neighborhood parks at night. To research and analyze the distribution of illumination level at urban neighborhood parks, I selected 8 urban neighborhood parks as the subject of research in this study, set the measuring standard of illumination level, and measured the illumination level by the measuring standard. The results of this study are as follows; 1. Currently, total average illumination level of urban neighborhood parks was lower than the minimum standard of illumination level I KS A 3011-1993. 2. Average illumination level of each place in urban neighborhood parks appeared variously from low level to high level. But this was lower than the minimum standard illumination level in KS A3011-1993 like total average illumination level. 3. The higher was total average illumination level of urban neighborhood parks, the more various was brightness of places. Although users' aesthetic and mental desire or behavioral aspect relate with safety cannot be found by only survey and analyses of illumination level, it is judged that first, illumination level of the standard of the lightness should be analyzed to find user's mental states and behaviors in external space at night. Therefore, it is considered that this study, which analyzed characteristics illumination level as basic data, has a significance. The study continuing for other illuminative environmental factors suitable in the place is required because the brightness of places may not be measured by only illumination level. And the proper illumination level in outdoor places should be showed in considering psychological and behavioral aspects of human as people may have their own sense of brightness.

  • PDF

농촌 청소년 공부방의 조명환경 실태조사 (Actual Conditions on the Illumination Environment of the Study Rooms in the Youth of an Agriculture Village)

  • 김현지;전경선;이인효;안옥희
    • 조명전기설비학회논문지
    • /
    • 제23권4호
    • /
    • pp.1-7
    • /
    • 2009
  • 본 연구에서는 농촌 청소년 공부방을 대상으로 조명환경 실태조사를 실시하였다. 그 결과, 공부방의 평균 공간의 크기는 11.42[$m^2$]이며, 주로 광원은 형광등을 사용하였으며 조명사용방법은 전반조명만 이용하는 경우가 73.8[%]이며, 배광방식은 직접조명 방식을 주로 사용하고 있었다. 또한 스탠드를 소유하고 있는 가구는 45.7[%]이었으며, 국부조명인 스탠드를 사용하는 비율은 전체 조사대상의 20[%]에 지나지 않아 시작업이 효과적이지 못하였다. 내부공간 조도는 평균 131.82[lx]이며, 책상면 조도는 253.64[lx]로 최저허용조도의 42.3[%]에 해당하는 열악한 실정이었으며, 균제도는 평균 35.61[%]로 나타났다. 또한 사용자의 조명환경에 비해 만족도는 3.93점으로 높아 조명에 대한 인식이 매우 부족한 것으로 사료된다.

치과 진료실의 조명에 관한 실태 조사연구 (A STUDY ON THE ILLUMINATION OF DENTAL CLINIC)

  • 최종인;김유리;동진근
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.374-382
    • /
    • 2006
  • Purpose: This study was designed to investigate the present conditions of illumination techniques in dental clinics in order to contribute improvement of operating environment. This study also aimed exploring qualitative and quantitative luminous intensity required for color temperature in dental clinic illumination, which was a critical part of esthetic dentistry. Materials and methods: A total of forty-eight local dental clinics were selected for sampling a) luminous intensity, and b) color temperature. The author measured the luminous intensity and the color temperature with lux meter and color meter respectively between 12pm and 2pm. The dental unit chair placed in the general operation positions were kept the distance 60 cm then all dental units were measured three times and averaged. The author measured the luminous intensity and color temperature with both common dental operating light and then without operating light in different office environments. The study was conducted under three conditions: 1 artificial illumination in clear day light 2. artificial illumination in cloudy day light, and 3. artificial illumination alone. Results : The results obtained were as follows. 1. The average luminous intensity in dental clinic lighting was 425 lux which was not sufficient to produce the optimal shade of the patient's teeth. Furthermore, the average luminous intensity even in full operating lighting was 9532 lux which fell short of the required level of 10,000 lux. 2. The average color temperature of all dental clinics surveyed was 5169 K which met the optimal range. However, only 33.3% fell in the correct region between 5,000-5,500 K as 25% were over 5,500 K and 41.6% were below 5,000 K. As a result, 66.7% were under insufficient color temperature conditions. 3. The dental unit chair placed next to a window, hence exposure to natural lighting, had significantly higher luminous intensity and color temperature compared to the dental unit chair which didn't have a window or natural lighting. 4. The data analysis revealed that only 6.3% of the dental clinic were met the standard of the average luminous intensity and color temperature.

중첩모델을 이용한 조명용 LED 렌즈설계 및 분석 (The design and the analysis of a LED illumination lens using the overlapped model)

  • 유일현
    • 한국정보통신학회논문지
    • /
    • 제21권1호
    • /
    • pp.157-164
    • /
    • 2017
  • 본 연구는 균일한 조명을 얻기 위해 중첩 조명 모델(overlapped illumination model)을 사용하여 자유 형상 렌즈(freeform lens)를 제작하였으며, 제작한 LED 렌즈들의 특성을 비교 분석하였다. 제작한 렌즈는 LED 광원의 위치변화, 두께 및 기울임을 이용해 성능을 평가하였다. 아울러 조명영역은 평균 조도 (average illuminance)와 조도 균일도 (illuminance uniformity) 변화 값으로 측정하였다. 광도 분포의 Z축 방향변화에 대해서는 중첩 모델과 발산 모델이 대체로 비슷한 공차 특성을 보였으나, 렌즈두께 변화에 대해서는 중첩모델이 발산모델에 비해 조도 균일도 공차 특성은 현저히 개선됨을 확인하였다. 또한, 발산 조명 모델로 설계된 렌즈가 전반적으로 좋은 성능을 나타냈으나, LED 방출에 대한 성능은 중첩 모델에서 그 편차의 폭이 상대적으로 적게 나타났다.

업무공간의 조명 환경 실태 조사 연구 (A Study on the Status of Illumination Environment in Workplaces)

  • 최한희;하미경
    • 한국실내디자인학회논문집
    • /
    • 제13권6호
    • /
    • pp.167-174
    • /
    • 2004
  • The purpose of this study is to examinethe present illumination conditions in office environment and to suggest an efficient illumination plan in office planning process. Illumination conditions in work environment were surveyed in 6 offices to investigate whether the present illumination conditions were appropriate to the work type. The results of this study are as follows: Most of the general Illuminance level in the area of work were all at an adequate level, except one. The average Illuminance level in the all meeting rooms were met for the standard. Illuminance in the all reception area were extremely over the standard, The illuminations of this area were rather designed according to the image of the company than the standard. As for the illumination method in the area of general work, four offices used a general lighting by a direct lighting type, while two offices used a general lighting and a task lighting at the same time. This survey suggested that first, each company should consider illumination plan in the building planning process, second, illumination plan considering the type of places is needed, and third, illumination environment may be differentiated according to the work type. In conclusion, efficient illumination environment should be considered in office building planning process, especially In terms of illumination materials and methods.

쇼윈도 조명환경에 관한 (A Study on the Illumination Environment in Show Window)

  • 김현지;안옥거
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1993년도 추계학술발표회논문집
    • /
    • pp.32-37
    • /
    • 1993
  • This study investigates the relationship between size, illumination ,and display of show window. The average width, heigh, and depth of show windows in Taegu area were 341.3, 233.4, and 125.8cm, respectively. As light source, halogen lamp was most frequently used, followed by fluorescent lamp and incandescence lamp. In the actual illumination, however, a combined use of more than 2 light sources was common. Further, a local illumination method, e.g., spot light, was generally adopted. The thought of employers and employees in fashion shops about display and illumination was examined aw well. On the whole, the necessity and importance of display were well recognized but the fact that the illumination should be hamonized with other factors such as color and arrangement of goods was underestimated.

  • PDF

주색도 분석을 적용한 비음수 행렬 분해 기반의 광원 추정 (Illumination Estimation Based on Nonnegative Matrix Factorization with Dominant Chromaticity Analysis)

  • 이지헌;김대철;하영호
    • 전자공학회논문지
    • /
    • 제52권8호
    • /
    • pp.89-96
    • /
    • 2015
  • 인간의 시각은 색순응을 통해서 사물의 색을 광원의 색에 영향 없이 인지 할 수 있다. 반면에, 카메라는 입력 값을 그대로 기록하기 때문에, 광원에 따라 물체의 색이 다르게 나타난다. 최근에 희박성 제약조건의 비음수 행렬 분해(nonnegative matrix factorization with sparseness constraint; NMFsc)를 이용한 광원추정 방법이 제안되었다. 이 방법은 낮은 희박성 제약조건을 사용해서 광원을 추정하고, 높은 희박성 제약조건을 사용해서 반사율을 추정한다. 하지만, 희박성 제약조건의 비음수 행렬분해를 이용한 광원 추정 방법은, 영상의 전역적인 정보를 사용하므로, 영상에서 동일한 색이 넓은 영역에 존재하는 경우, 추정된 광원이 큰 오차를 가진다. 이러한 단점을 보완하기 위해, 영상에서 주색도 분석과 희박성 제약조건의 비음수 행렬 분해를 이용한 광원 추정 방법을 제안하였다. 먼저 주색도를 분석하기 위해 영상을 색도 좌표계로 옮기고 색도 히스토그램을 이용하여 유사한 색도를 가지는 영역들로 영상을 분할한다. 다음으로 영상의 주색도는 분할된 영상들 중 색도의 표준편차가 가장 적은 영상의 색도로 선택한다. 마지막으로 주색도 분석 결과와 희박성 제약조건의 비음수 행렬 분해를 이용해 입력 영상에서 주색도 성분을 제거하고 최종적인 광원을 추정한다. 실제 촬영 영상에 대한 평균 각오차를 사용하여 기존의 방법과의 성능을 비교하였고, 그 결과 제안하는 방법의 평균 각 오차는 5.5를 나타내어 영상의 주 색도를 포함하여 광원을 추정한 기존 방법의 평균 각 오차 5.7 보다 우수한 성능을 나타내었다.

자연채광 설계용 기상자료의 개발에 관한 연구 (A Study on the development of climatic data for the daylighting design)

  • 양인호;김광우;김문한
    • 태양에너지
    • /
    • 제11권1호
    • /
    • pp.3-15
    • /
    • 1991
  • 본 연구에서는 자연채광 설계용 천공의 조건을 (1) clear sky (2) partly cloudy sky (3) cloudy sky로 나누어서 서울지역의 수평면에 대해서 전천공조도와 함께 반원형의 띠를 이용하여 확산조도를 측정한다. 천공 상태의 분류는 프랑스의 낭뜨 측정에서의 방법을 이용하였다. 본 연구에서 제시된 자연채광 설계용 기상자료는 (1) 태양고도에 따른 수평면 조도 (2) 조도의 월변화 (3) 조도의 누적표현율 (4) 하루중의 주광 강도의 변화 (5) 특정 조도 이상을 기록한 시간수이다.

  • PDF

퍼지 추론과 구역 공간법을 이용한 조도 계산법 (Calculation of Illuminance Using Fuzzy Reasoning and Zonal Cavity Method)

  • 최홍규;강태은;원진희;조용상
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.240-246
    • /
    • 1999
  • This parer proposes fuzzy reasoning algorithm for improvement in Zonal Cavity Method that is difficult to calculate average illumination without lighting scope and reflection factor so on. This parer use fuzzy reasoning algorithm for maintainment of the best illumination in spite of some variation those are influenced of room illumination and cut down the difficult to be calculated used Zonal Cavity Method.

  • PDF