• Title/Summary/Keyword: Available capacity

Search Result 1,150, Processing Time 0.026 seconds

Vegetation and Soil Properties of Corylopsis coreana Population in Korea (히어리(Corylopsis coreana) 개체군의 식생과 토양특성)

  • Jang, Hyung-Tae;Kim, Nam-Choon;Kim, Mu-Yeol;Kwon, Hye-Jin;Song, Ho-Kyung
    • Korean Journal of Environment and Ecology
    • /
    • v.22 no.6
    • /
    • pp.609-615
    • /
    • 2008
  • The study was conducted to analyze vegetation and soil characteristic of Corylopsis coreana population in Baekunsan of Gyeonggi-Do, Jirisan, Baekunsan, Jogaesan of Jeollanam-do, and Geumsan of Gyeongsangnamdo. Field research was from September 2005 to September 2006. According to classification with phytosociological method, the Corylopsis coreana population was classified into Tilia amurensis dominant population, Lindera erythrocarpa dominant population, and Pinus densiflora dominant population. According to CCA ordination, the Tilia amurensis dominant population were located in area of high elevation, and high concentration in total nitrogen, available phosphorous, and cation exchangeable capacity(CEC). The Pinus densiflora dominant population were located in area of low elevation, and low concentration in total nitrogen, available phosphorous, and cation exchangeable capacity. The Lindera erythrocarpa dominant population were located in area of high elevation, and medium concentration in total nitrogen, available phosphorous, and cation exchangeable capacity.

Rational Evaluation of Seismic Response Modification Factor of Steel Moment Frame Based on Available Connection Rotation Capacity (접합부 회전능력에 기초한 철골모멘트골조의 반응수정계수 산정법)

  • Lee, Cheol-Ho;Kim, Geon-Woo;Song, Jin-Gyu
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.2 s.54
    • /
    • pp.11-17
    • /
    • 2007
  • In current seismic design practice, the response modification factor (R-factor) is used as a factor to reduce the elastic base shear demand to the design force level. As is well-known, the R-factor is a committee-consensus factor and, as such, highly qualitative and empirical. The relationship between the R-factor and the connection rotation capacity available in a particular structural system has remained a missing link. In this paper, a rational procedure to evaluate the R-factor is proposed. To this end, the relationship between the available connection rotation capacity and the R-factor is defined and quantified using nonlinear pushover analysis. An RRS steel frame designed according to IBC 2000 was used to illustrate and verify the proposed procedure. Nonlinear time history analysis results indicated that the R-factor definition proposed in this study is generally conservative from design perspective.

Asymptotic performance analysis of closed serial production systems (패쇄직렬 생산시스템의 점근적 성능해석)

  • 임종태
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.519-522
    • /
    • 1990
  • This paper formulates a problem of analysis and design of serial production lines, closed with respect to the number of carriers available in the system for parts transportation between operations. For two machines - two buffers systems, the paper gives an asymptotic solution and shows that optimization of the system with respect to the number of carriers available and the capacity of the feedback buffer may lead to substantial improvements of system's performance.

  • PDF

Numerical studies on axially loaded doubler plate reinforced elliptical hollow section T-joints

  • Sari, Busra;Ozyurt, Emre
    • Steel and Composite Structures
    • /
    • v.43 no.1
    • /
    • pp.107-116
    • /
    • 2022
  • This paper presents results of numerical studies completed on unreinforced and doubler plate reinforced Elliptical Hollow Section (EHS) T-joints subjected to axial compressive loading on the brace member. Non-linear finite element (FE) models were developed using the finite element code, ABAQUS. Available test data in literature was used to validate the FE models. Subsequently, a parametric study was carried out to investigate the effects of various geometrical parameters of main members and reinforcement plates on the ultimate capacity of reinforced EHS T-joints. The parametric study found that the reinforcing plate significantly increases the ultimate capacity of EHS T-joints up to twice the capacity of the corresponding unreinforced joint. The thickness and length of the reinforcing plate have a positive effect on the ultimate capacity of Type 1 joints. This study, however, found that the capacity of Type 1 orientation is not dependent on the brace-to-chord diameter ratio. As for type 2 orientations, the thickness and length of the reinforcement have a minimal effect on the ultimate capacity. A new design method is introduced to predict the capacity of the reinforced EHS T-joints Type 1 and 2 based on the multiple linear regression analyses.

Theoretical and experimental study on shear strength of precast steel reinforced concrete beam

  • Yang, Yong;Xue, Yicong;Yu, Yunlong
    • Steel and Composite Structures
    • /
    • v.32 no.4
    • /
    • pp.443-454
    • /
    • 2019
  • With the aim to put forward the analytical model for calculating the shear capacity of precast steel reinforced concrete (PSRC) beams, a static test on two full-scale PSRC specimens was conducted under four-point loading, and the failure modes and strain developments of the specimens were critically investigated. Based on the test results, a modified truss-arch model was proposed to analyze the shear mechanisms of PSRC and cast-in-place SRC beams. In the proposed model, the overall shear capacity of PSRC and cast-in-place SRC beams can be obtained by combining the shear capacity of encased steel shape with web concrete determined by modified Nakamura and Narita model and the shear capacity of reinforced concrete part determined by compatible truss-arch model which can consider both the contributions of concrete and stirrups to shear capacity in the truss action as well as the contribution of arch action through compatibility of deformation. Finally, the proposed model is compared with other models from JGJ 138 and AISC 360 using the available SRC beam test data consisting of 75 shear-critical PSRC and SRC beams. The results indicate that the proposed model can improve the accuracy of shear capacity predictions for shear-critical PSRC and cast-in-place SRC beams, and relatively conservative results can be obtained by the models from JGJ 138 and AISC 360.

An Evaluation of ACI 349 Code for Shear Design of CIP Anchor (직매형 앵커기초의 전단설계를 위한 ACI 349 Code의 평가)

  • Jang Jung-Bum;Hwang Kyeong-Min;Suh Yong-Pyo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.464-470
    • /
    • 2005
  • The numerical analysis is carried out to identify the influence of design factors to shear capacity of cast-in-place (CIP) anchor in ACI 349 Code that is available for the design of fastening system at Nuclear Power Plant (NPP) in this study. The MASA program is used to develop the numerical analysis model and the developed numerical analysis model is verified on a basis of the various test data of CIP anchor. Both $l/d_o$ and $c_1/l$ we considered as design factors. As a result, the variation of $l/d_o$ has no influence on the shear capacity of CIP anchor but $c_1/l$ has a large influence on the shear capacity of CIP anchor, Therefore, it is proved that ACI 349 Code may give a non-conservative results compared with real shear capacity of CIP anchor according to $c_1/l$.

  • PDF

Explicit Formulae for Characteristics of Finite-Capacity M/D/1 Queues

  • Seo, Dong-Won
    • ETRI Journal
    • /
    • v.36 no.4
    • /
    • pp.609-616
    • /
    • 2014
  • Even though many computational methods (recursive formulae) for blocking probabilities in finite-capacity M/D/1 queues have already been produced, these are forms of transforms or are limited to single-node queues. Using a distinctly different approach from the usual queueing theory, this study introduces explicit (transform-free) formulae for a blocking probability, a stationary probability, and mean sojourn time under either production or communication blocking policy. Additionally, the smallest buffer capacity subject to a given blocking probability can be determined numerically from these formulae. With proper selection of the overall offered load ${\rho}$, the approach described herein can be applicable to more general queues from a computational point of view if the explicit expressions of random vector $D_n$ are available.

Pullout capacity of vertical plate anchors in cohesion-less soil

  • Kame, G.S.;Dewaikar, D.M.;Choudhury, Deepankar
    • Geomechanics and Engineering
    • /
    • v.4 no.2
    • /
    • pp.105-120
    • /
    • 2012
  • In this paper, the ultimate pullout capacity of a vertical plate strip anchors in cohesion-less soil is analyzed with the consideration of active and passive state of equilibrium in the soil. K$\ddot{o}$tter's equation is used to compute the active and passive thrusts (along with their point of application) which are subsequently used in the analysis in which, all the equation of equilibrium are properly interpreted. A comparison of the results with the experimental results vis-$\grave{a}$-vis available theoretical/empirical solutions shows that, the proposed analysis provides a better estimate of the pullout capacity.

A bimodal Weibull distribution - capacity factor for different heights at sulur

  • Seshaiah, C.V.;Indhumathy, D.
    • Wind and Structures
    • /
    • v.28 no.1
    • /
    • pp.63-70
    • /
    • 2019
  • Due to developing environmental concern use of renewable energy source is very essential. The great demand for the energy supply coupled with inadequate energy sources creates an emergency to find a new solution for the energy shortage. The appropriate wind energy distribution is the fundamental requirement for the assessment of wind energy potential available at the particular site essential for the design of wind farms. Hence the proper specification of the wind speed distribution plays a vital role. In this paper the Bimodal Weibull distribution is used to estimate the Capacity factor at the proposed site. The shape and scale parameters estimated using Maximum likelihood method is used as the initial value for extrapolation. Application of this model will give an accurate result overwhelming the concept of overestimation or underestimation of Capacity factor.

Available Soil Water for Textural Class of Korean Soils (우리나라 토양(土壤)의 토성별(土性別) 유효수분(有效水分))

  • Jung, Sug-Jae;Moon, Joon;Kim, Tai-Soon;Hyeon, Geun-Soo;Park, Chang-Seo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.23 no.3
    • /
    • pp.167-172
    • /
    • 1990
  • Some of soil properties already known were selected for the determination of their effect on soil moisture characteristics. Total number of 2,808 representative samples from all over Korea with the exception of Jeju Island were investigated. 1. Available water contents were 4.7 for S, 7.7 for LS, 13.2 for SL, 17.7 for L, 19.2 for SiL, 15.9 for CL, 14.5 for SCL, 18.7 for SiCL, 17.3 for SiC, and 14.9% for C, respectively. 2. Simple regression analysis showed that field capacity and available water content were most strongly associated with sand content in coarse-textured soils, and with organic matter content in fine-textured soils, whereas permanent wilting point was closely associated with clay content. 3. Available water was strongly associated with silt content and also significantly with field capacity, but either not at all or negatively with permanent wilting point. 4. Prediction equations for available water and field capacity were drown out from known soil properties, which can be used for each textural class.

  • PDF